Attch 24 M801.pdf

PDF 126 KB Posted

Attached to
DLA Building 54 Navy Artifact Restoration Federal contract opportunity
Solicitation number
W9123622B2041
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document package includes a mechanical control system design drawing and related federal contract solicitation. The solicitation seeks proposals for HVAC system design services for a Navy artifact restoration room in Building 54 at the DLA facility in Richmond, Virginia. The Army Corps of Engineers Norfolk District will award a firm-fixed price contract for the HVAC system design work depicted on the attached drawing. Proposals were due by December 7, 2022 under solicitation number W91236-22-B-2041. The control system drawing provides details on the existing BAS network and sequences of operation, along with requirements for integrating new equipment into the Jace controller system.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Building 54 Navy Artifact Restoration, newest first.
File Type Posted
B.01.02_22B2041 Abstract of Offers.pdf PDF
Attch 27 01 45 04.00 50.pdf PDF
W9123622B2041 Amendment 0011.pdf PDF
Amendment 10 Final.pdf PDF
Amendment 9 Final.pdf PDF
W9123622D2041 Amendment 0008.pdf PDF
W9123622B2041 Amendment 0006.pdf PDF
Attch 26 EL101.pdf PDF
Attch 23 M602.pdf PDF
Attch 17 FA101.pdf PDF
Attch 10 AD111.pdf PDF
Attch 5 01 50 02 00 50.pdf PDF
Attch 1 Project Table of Contents 00 00 00.pdf PDF
Attch 21 MP101.pdf PDF
Attch 18 MD101.pdf PDF
Attch 13 A111.pdf PDF
Attch 8 AD101.pdf PDF
Attch 7 08 33 23.pdf PDF
Attch 22 M601.pdf PDF
Attch 19 MH101.pdf PDF
Attch 16 A601.pdf PDF
Attch 15 A301.pdf PDF
Attch 14 A112.pdf PDF
Attch 11 AD112.pdf PDF
Attch 9 AD102.pdf PDF
Attch 6 03 30 53.pdf PDF
22B2041 Amendment 0006.pdf PDF
Attch 25 M805.pdf PDF
Attch 20 MH111.pdf PDF
Attch 12 AD122.pdf PDF
Attch 4 01 45 35.pdf PDF
Attch 3 01 45 35 SI Schedule - 1-28-2022.pdf PDF
Attch 2 01 45 35 Statement of Special Inspections - 1 28 2022.pdf PDF
W9123622B2041 Amendment 0005.pdf PDF
22B2041 B54 HVAC Amendment 4.pdf PDF
19 Jan Site visit.pdf PDF
Amendment 0003 Final.pdf PDF
Amendment 0002 Final.pdf PDF
Amendment 0001 Final.pdf PDF
Site Visit 5 January.pdf PDF
A.01.13_0455737 NAO663A B54-HVAC-ARTIFACT-IFB-DRAWINGS.pdf PDF
A.01.13_0455737 NAO663A B54-ARTIFACT-SPECS.pdf PDF
W9123622B2041 IFB.pdf PDF
Show all 43

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AHU-1

SF VFD

BC

ROOF

BCACC-1

VFD

VFD

TYPICAL

PUMP VFD

BCEXHAUST

FANS

SYSTEM CONTROL NETWORK.

RS-485 TYPE NETWORK

TWISTED PAIR WIRE (TYP)

NOTES:

BC

CRAC UNIT MANUFACTURERS

CONTROLLERS

ROOF

FIRST FLOOR

BUILDING LEVEL NETWORK

MINIMUM SPEED 10/100 MBPS

CAT-6 ETHERNET CABLE

(TYP)

BACNET

BMS ETHERNET

SWITCH/HUB

UPS

REPORT

PRINTER

(LASER PRINTER)

ALARM

PRINTER

(DOT-MATRIX)

OPERATOR WORKSTATION

W/ REPORT AND ALARM

PRINTERS

NOTE 2

CRAC-3CRAC-2CRAC-1

NOTE 14

NOTE 1

1. ALL BAS EQUIPMENT, CONTROLLERS AND NETWORK EQUIPMENT SHALL BE FED FROM 120 VOLT STANDBY POWER BY DIV. 26.

2. 24 VOLT WIRING TO CONTROLLERS BY CONTROLS CONTRACTOR.

3. ONLY A REPRESENTATIVE SAMPLE OF CONTROLLERS ARE SHOWN. COMPLETE SYSTEM ARCHITECTURE TO BE PROVIDED BY CONTROLS CONTRACTOR.

4. NETWORK WIRING IS DIAGRAMMATIC, ACTUAL ROUTING DIAGRAM PROVIDED BY DIVISION 23.

5. ALL EQUIPMENT AND WIRING BY CONTROLS CONTRACTOR, UNLESS NOTED OTHERWISE.

6. NETWORK CONFIGURATION SHALL CONFORM WITH ALL PERFORMANCE REQUIREMENTS IN SECTION 23 09 00.

7. PROVIDE LOCKABLE ENCLOSURES FOR ALL BCs AND NETWORK EQUIPMENT.

8. LOCATE ADJACENT TO BASE BUILDING BAS ETHERNET SWITCH.

9. CONFIRM LOCATION WITH CLIENT PRIOR TO INSTALLATION.

10. EACH PANEL TO HAVE AN ETHERNET CONNECTION ON THE OUTSIDE OF THE PANEL FOR A LAPTOP CONNECTION BY FACILITY PERSONNEL.

11. ALL COMMUNICATION CABLE OUTSIDE OR BETWEEN BUILDINGS SHALL BE FIBER OPTIC.

12. REFER TO DRAWING M-800 FOR SYMBOLS AND ABBREVIATIONS.

13. 120 VOLT POWER PROVIDED AS SHOWN ON DRAWING BY DIVISION 26, ALL WIRING FROM JUNCTION BOXES TO POINT OF USE BY DIVISION 23 09 13.

14. THE BUILDING 54 BAS SYSTEM WAS UPGRADED IN 2016 TO HONEYWELL TRIDIUM JACE CONTROLLERS. ALL NEW EQUIPMENT FROM THIS PROJECT SHALL BE CONNECTED TO THE EXISTING JACE CONTROLLERS, EXPANDING UPON THEM IF NECCESSARY. IF IT BECOMES NECESSARY TO REPLACE A JACE CONTROLLER, AN 8000 VERSION 4 CONTROLLER SHALL BE USED.

15. THE BAS HEAD END EQUIPMENT AND OPERATOR WORKSTATION(S) ARE EXISTING AND THE SYSTEM GRAPHICS WILL NEED UPDATED TO REFLECT NEW EQUIPMENT INSTALLED UNDER THIS PROJECT.

GENERATOR MONITORING

SYSTEM

SYSTEM ARCHITECTURE CONTROL DIAGRAM

SCALE: NTS

FIRST FLOOR

DOWN DUCT

STATIC

PRESSURE

SENSOR

VAV1-2 CONVERSATION LAB

PRESSURIZATION

SENSOR

VAV1-1

UNITARY EQUIPMENT CONTROLS NOTE:

(UNITS) EQUIPMENT SHALL BE FACTORY PROVIDED WITH MANUFACTURERS'

UNIT MOUNTED CONTROLLERS. THE (UNITS) UNIT MANUFACTURER SHALL BE

RESPONSIBLE FOR EXECUTING THE SEQUENCE OF OPERATIONS INDICATED ON

THE DRAWINGS. COMMUNICATION TO A 3RD PARTY CONTROLLER IS NOT

ACCEPTABLE.

IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO

ENSURE THE ENTIRE SYSTEM (MECHANICAL EQUIPMENT AND AUTOMATIC

TEMPERATURE CONTROLS) MEETS THE ENTIRE SEQUENCE OF OPERATIONS, IS

FULLY INTEGRATED, BE FREE OF DEFECTS, AND FUNCTION AS SPECIFIED.

SHOULD AN ALTERNATE MANUFACTURER BE SELECTED OTHER THAN THE BASIS

OF DESIGN, THAT MANUFACTURER'S UNIT MOUNTED CONTROLLER SHALL FULLY

MEET THE SPECIFIED CONTROL SEQUENCE. (NO EXCEPTIONS)

A I

N I

G

RI

VFOHTLAE

W

N O

M M

O C

P R

O F

E

SS I ONAL ENG

I N E

E R

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S N

O R

F O

L K

D

IS

T R

IC

T

F

R O

N T

S T

N

O R

F O

L K

V

A

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

SEAL

BRANDON E. WOOD

Lic. No. 35155

10/15/21

N A

O F

IL

E

N O

A

M-801

C O

N T

R O

L S

B U

IL

D

IN

G

J

E F

F E

R S

O N

D A

V

IS

H W

Y R

IC

H

M O

N D

V

A

W S

P B

E N

D

IX

R D

S T

E

V

IR

G

IN

IA

B

E A

C H

V

A

J S

M

IT

H

C B

R A

N N

IN

G

K O

L T

B W

O O

D

O C

T

W G

L G

W

6-

-D

-0

1-

B U

IL

D

IN

G

D

E S

IG

N

F O

R H

V A

C S

Y S

T E

M S

I N

N A

V Y

A R

T

IF

A C

T R

O O

M

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

/3 /2

File details come from the government source that posted it. Updated .