About this file
This document package includes construction drawings and specifications for renovations to Building 54 at the DLA facility in Richmond, Virginia. Key details include specifications for replacing existing overhead doors, repairing and painting door frames, installing new door hardware, and completing interior finish work. Renovations will update multiple room finishes, doors, frames and hardware across various areas of the building, including storage, mechanical, receiving and laboratory spaces. The related federal contract opportunity is solicitation number W91236-22-B-2041 from the Department of the Army Corps of Engineers Engineering District Norfolk for restoration services at the Navy Artifact building. The pre-bid posting date was December 7, 2021.
View the file
Other files for this federal contract opportunity
Show all 43
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AS SCHEDULED
AS
S
C H
ED
U
LE
D
A OH
OVERHEAD DOOR
EXISTING DOOR
FRAME
EXISTING DOOR
PERIMETER
GASKETING
WEATHERSTRIP
EXISTING MASONRY
WALL. INTERIOR
FINISHES VARIES.
REF FINISH
SCHEDULE
METL STUD
AND GYPSUM
BOARD
PARTITION
EXISTING DOORPERIMETER
GASKETING
WEATHERSTRIP
EXISTING DOOR FRAME
EXISTING
DOOR
PERIMETER
GASKETING
WEATHERSTRIP
EXISTING MASONRY
WALL. INTERIOR
FINISHES VARIES.
REF FINISH
SCHEDULE
EXISTING DOOR
FRAME
EXISTING
DOOR
PERIMETER
GASKETING
WEATHERSTRIP
PERIMETER
GASKETING
WEATHERSTRIP
EXISTING DOOR
FRAME
EXISTING DOOR
EXISTING MASONRY
PARTITION. REF
FINISH SCHEDULE
EXISTING DOOR
FRAME
EXISTING
DOOR
PERIMETER
GASKETING
WEATHERSTRIP
EXISTING MASONRY
PARTITION. REF
FINISH SCHEDULE
DOOR SCHEDULE
DOOR
NUMBER TYPE
DOOR FRAME
EXISTING HARDWARE
ON DOOR
NEW HARDWARE ON
DOOR & FRAME COMMENTS
SIZE DETAILS
WIDTH HEIGHT
THICKNES
S HEAD JAMB
THRESHO
LD
110B A 6'-0" 7'-0" 1 3/4" H1 E1 REF
A8/301
RE-USE EXISTING HW-1 RE-USE EXISTING DOOR UNIT
111B A 3'-0" 7'-0" 1 3/4" H1 E1 REF
A1/A301
RE-USE EXISTING HW-2 RE-USE EXISTING DOOR UNIT - REPAINT - TO
MATCH EXISTING
111C A 3'-0" 7'-0" 1 3/4" H1 E1 REF
A1/A301
RE-USE EXISTING HW-2 RE-USE EXISTING DOOR UNIT - REPAINT - TO
MATCH EXISTING
111D A 3'-0" 7'-0" 1 3/4" H1 E1 REF
A1/A301
RE-USE EXISTING HW-2 RE-USE EXISTING DOOR UNIT - REPAINT - TO
MATCH EXISTING
122A A 6'-0" 7'-0" 1 3/4" H5 E5 REF
A8/301
RE-USE EXISTING HW-1 INSTALL EXISTING CARD READER, RE-USE EXISTING
DOOR UNIT
124A A 5'-0" 7'-0" 1 3/4" H5 E5 --- RE-USE EXISTING HW-1 RE-USE EXISTING DOOR UNIT 125A OH 12'-5" 11'-4" REF SPEC. H5 E5 EXISTING REF SPECIFICATION - DOOR MOTORIZED, INSULATED - FACTORY
FINISH-TO MATCH EXISTING. REPAINT EXISTING
FRAME - TO MATCH EXISTING
125B OH 12'-5" 11'-4" REF SPEC. H5 E5 EXISTING REF SPECIFICATION - DOOR MOTORIZED, INSULATED - FACTORY
FINISH-TO MATCH EXISTING. REPAINT EXISTING
FRAME - TO MATCH EXISTING
126A A 6'-0" 7'-0" 1 3/4" H5 E5 REF
A8/301
RE-USE EXISTING HW-1 RE-USE EXISTING DOOR UNIT
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
N O
R
FO
LK
D
IS
TR
IC
T
FR
O
N T
ST
, N
O R
FO
LK
, V A, D
R
AW
N B
Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
SEALGRAPHIC SCALES
N
AO
F
IL
E N
O
3A
A-601
D O
O R
S C
H
ED
U
LE
A N
D D
ET
AI
LS
BU
IL
D
IN
G
4, JE
FF
ER
SO
N D
AV
IS
H W
Y, R
IC
H
M O
N D
VA
, 2
W
SP
BE
N
D
IX
R D
S
TE
VI
R
G
IN
IA
B
EA
C
H , V
A, K.
O
LT
R . D
U C
H
ES
N E
K.
O
LT
M . D
E
PA
D U
A
O C
TO
B
ER
5, W
G
LG
W
6-
-D
-0
1-
BU
IL
D
IN
G
D
ES
IG
N F
O R
H
VA
C S
YS
TE
M S
IN
N
AV
Y
AR
TI
FA
C
T R
O O
M
SCALE: 1/4" = 1'-0"
DOOR TYPE
SCALE: 1 1/2" = 1'-0"H1 EXTERIOR DOOR HEAD
SCALE: 1 1/2" = 1'-0"H9 INTERIOR DOOR HEAD
SCALE: 1 1/2" = 1'-0"E1 EXTERIOR DOOR JAMB
SCALE: 1 1/2" = 1'-0"E9 INTERIOR DOOR JAMB
SCALE: 1 1/2" = 1'-0"H5 INTERIOR DOOR JAMB
SCALE: 1 1/2" = 1'-0"E5 INTERIOR DOOR JAMB
0 4" 8" 1'-4"
SCALE: 1 1/2" = 1'-0"
ROOM FINISH SCHEDULE
NO. ROOM NAME FLOOR BASE
WALL FINISH CEILING
REMARKSNORTH EAST SOUTH WEST FINISH
110 DELTA ROOM -- -- PNT1 PNT1 PNT1 PNT1 ACT
111 HIGH DENSITY
COMPACT
STORAGE
-- VTB PNT1 PNT1 PNT1 PNT1 ACT VTB NORTH AND SOUTH
WALLS
121 NHHC STORAGE -- -- -- -- -- -- --
122 CORRIDOR -- -- -- -- -- -- --
123 MECHANICAL
ROOM
124 PRACTICE -- -- -- -- -- -- --
125 RECEIVING -- -- -- -- -- -- --
126 STORAGE -- -- PNT1 PNT1 PNT1 PNT1 ACT
128 JANITOR -- -- PNT2 PNT2 PNT2 PNT2 ACT
129 LAUNDRY -- -- PNT2 PNT2 PNT2 PNT2 ACT
130 ELECTRICAL
ROOM
131 CONSERVATION
LAB
-- -- PNT1 PNT1 PNT1 PNT1 ACT
132 CONSERVATION
LAB
-- -- PNT1 PNT1 PNT1 PNT1 ACT
133 WOMEN'S -- -- PNT2 PNT2 PNT2 PNT2 ACT
134 MEN'S -- -- PNT2 PNT2 PNT2 PNT2 ACT
FINISH LEGEND
VTB
VINYL TILE BASE, GREY, AS SELECTED FROM
MANUFACTURER'S FULL RANGE
ACT 2X2 ACOUSTICAL CEILING TILE, FLAT WHITE
PNT1 OFF WHITE AS SELECTED FROM MANUFACTURER'S
FULL RANGE TO MATCH EXISTING
PNT2 OFF WHITE HIGH-HUMIDITY PAINT AS SELECTED FROM
MANUFACTURER'S FULL RANGE TO MATCH EXISTING
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
AM
EN
D
M
EN
T 0 1
-B
ID
D
ER
IN
Q
U
IR
IE
S
1/
/2
File details come from the government source that posted it. Updated .