Attch 17 FA101.pdf
PDF 190 KB Posted
- Attached to
- DLA Building 54 Navy Artifact Restoration Federal contract opportunity
- Solicitation number
- W9123622B2041
About this file
This floor plan drawing and related federal contract opportunity are for fire alarm system upgrades at Building 54 on the campus of the U.S. Army Corps of Engineers in Norfolk, Virginia. The solicitation was posted on December 7, 2022 as number W91236-22-B-2041 and seeks bids to provide addressable duct smoke detectors, remove existing detectors, and coordinate locations with the mechanical contractor. The floor plan depicts Area A of the first floor of Building 54 and includes a room schedule, graphic scale, revision information, and the location of the existing fire alarm control panel. Bids were due by January 31, 2022 in response to Amendment 001, which provided bidder inquiries. The work appears focused on upgrading the fire alarm system for the U.S. Army Corps of Engineers facility in Norfolk to support restoration of Navy artifacts.
View the file
Other files for this federal contract opportunity
Show all 43
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
123 124 125
24 25
J
K
22 23
M A
T C
H L
IN
E
F /F
A
D
RT
PROVIDE ADDRESSABLE DUCT SMOKE
DETECTOR WITH REMOTE TEST/RESET
SWITCH. COORDINATE LOCATION WITH
MECHANICAL CONTRACTOR PRIOR TO
INSTALLATION.
THERE ARE FOUR (4) EXISTING DUCT
DETECTORS IN THIS ROOM (NOT SHOWN)
WHICH ARE TO BE REMOVED.
KEYNOTES#
A I
N I
G
RI
VFOHTLAE
W
N O
M M
O C
P R
O F
E
SS I ONAL ENG
I N E
E R
8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S N
O R
F O
L K
D
IS
T R
IC
T
F
R O
N T
S T
N
O R
F O
L K
V
A
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
SEALGRAPHIC SCALES
PLAN
NORTH
KEYPLAN
MARTIN H. FORD
Lic. No. 048072
10/15/21
ARTIFACTS
A B
N A
O F
IL
E
N O
A
FA101
F L O
O R
P L A
N
A R
E A
A
F
IR
E A
L A
R M
B U
IL
D
IN
G
J
E F
F E
R S
O N
D A
V
IS
H W
Y R
IC
H
M O
N D
V
A
W S
P B
E N
D
IX
R D
S T
E
V
IR
G
IN
IA
B
E A
C H
V
A
D B
O G
G S
C R
O D
R
IG
U E
Z
K O
L T
M F
O R
D
O C
T
W G
L G
W
6-
-D
-0
1-
B U
IL
D
IN
G
D
E S
IG
N
F O
R H
V A
C S
Y S
T E
M S
I N
N A
V Y
A R
T
IF
A C
T R
O O
M
SCALE: 1/8" = 1'-0"
FLOOR PLAN – AREA A - FIRE ALARM
F1
1ST FLOOR ROOM
SCHEDULE - AREA A
122 CORRIDOR
123 MECHANICAL ROOM
124 PRACTICE
125 RECEIVING
126 STORAGE
130 ELECTRICAL ROOM
LOCATION OF EXISTING FIRE ALARM CONTROL PANEL
A
M E
N D
M E
N T
B
ID
D E
R I N
Q U
IR
IE
S
/3 /2
File details come from the government source that posted it. Updated .