This document contains reflected ceiling plans and demolition notes for Building 54 at the Jefferson Davis Highway facility in Richmond, Virginia. The plans show the layout of various rooms in Area B of the building, including storage areas, labs, mechanical and electrical rooms, and restrooms. Note 1 indicates that ceiling-mounted items will be removed and reinstalled in coordination with mechanical, electrical, and fire protection work. Note 2 specifies that exit signs will remain. Demolition Note 1 provides instructions for removing and disposing of existing acoustical ceiling panels while retaining the ceiling grid system.
View the file
Other files for this federal contract opportunity
Show all 43
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
26 27 28 29 30
J
K
10'-0"
8'-2"
M
AT
C H
LI
N
E
E1 /A
D
134110
131129128
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
N O
R
FO
LK
D
IS
TR
IC
T
FR
O
N T
ST
, N
O R
FO
LK
, V A, D
R
AW
N B
Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
SEALGRAPHIC SCALES
KEYPLAN
ARTIFACTS
A B
N
AO
F
IL
E N
O
3A
AD112
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
D
EM
O
LI
TI
O N
AR
EA
B
BU
IL
D
IN
G
4, JE
FF
ER
SO
N D
AV
IS
H W
Y, R
IC
H
M O
N D
VA
, 2
W
SP
BE
N
D
IX
R D
S
TE
VI
R
G
IN
IA
B
EA
C
H , V
A, K.
O
LT
R . D
U C
H
ES
N E
K.
O
LT
M . D
E
PA
D U
A
O C
TO
B
ER
5, W
G
LG
W
6-
-D
-0
1-
BU
IL
D
IN
G
D
ES
IG
N F
O R
H
VA
C S
YS
TE
M S
IN
N
AV
Y
AR
TI
FA
C
T R
O O
M
SCALE: 1/8" = 1'-0"E1 REFLECTED CEILING PLAN - DEMOLITION - AREA B
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
PLAN
NORTH
ROOM SQUARE FEET
NO. ROOM NAME AREA
110 DELTA ROOM 569 SF
111 HIGH DENSITY COMPACT STORAGE 5708 SF
122 CORRIDOR 488 SF
123 MECHANICAL ROOM 2683 SF
124 PRACTICE 470 SF
125 RECEIVING 812 SF
126 STORAGE 643 SF
128 JANITOR 75 SF
129 LAUNDRY 73 SF
130 ELECTRICAL ROOM 267 SF
131 CONSERVATION LAB 1075 SF
132 CONSERVATION LAB 295 SF
133 WOMEN'S 134 SF
134 MEN'S 129 SF
# DEMOLITION KEYNOTES
1 REMOVE AND DISPOSE OF ACOUSTICAL CEILING
PANELS COMPLETELY. RETAIN CEILING GRID
SYSTEM. AT THE CONTRACTORS DISCRETION, THE
CEILING GRID CAN BE REMOVED. STORAGE OF THE
GRID UNTIL REINSTALLATION SHALL BE AT THE
CONTRACTORS RISK. THE GRID SHALL BE STORED
WITHIN THE CONTRACTORS DESIGNATED
LAYDOWN AREA AND NOT LEFT EXPOSED TO THE
ELEMENTS.
2 EXIT SIGN TO REMAIN. REF ELEC FOR DEVICE
CHANGES
SHEET NOTES
1. COORDINATE THE REMOVAL AND REINSTALLATION OF
CEILING MOUNTED ITEMS WITH MEP & FP WORK.
AM
EN
D
M
EN
T 0 1
-B
ID
D
ER
IN
Q
U
IR
IE
S
1/
/2
File details come from the government source that posted it. Updated .