About this file

This document contains reflected ceiling plans and demolition notes for Building 54 at the Jefferson Davis Highway facility in Richmond, Virginia. The plans show the layout of various rooms in Area B of the building, including storage areas, labs, mechanical and electrical rooms, and restrooms. Note 1 indicates that ceiling-mounted items will be removed and reinstalled in coordination with mechanical, electrical, and fire protection work. Note 2 specifies that exit signs will remain. Demolition Note 1 provides instructions for removing and disposing of existing acoustical ceiling panels while retaining the ceiling grid system.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Building 54 Navy Artifact Restoration, newest first.
File Type Posted
B.01.02_22B2041 Abstract of Offers.pdf PDF
Attch 27 01 45 04.00 50.pdf PDF
W9123622B2041 Amendment 0011.pdf PDF
Amendment 10 Final.pdf PDF
Amendment 9 Final.pdf PDF
W9123622D2041 Amendment 0008.pdf PDF
W9123622B2041 Amendment 0006.pdf PDF
22B2041 Amendment 0006.pdf PDF
Attch 25 M805.pdf PDF
Attch 20 MH111.pdf PDF
Attch 12 AD122.pdf PDF
Attch 4 01 45 35.pdf PDF
Attch 3 01 45 35 SI Schedule - 1-28-2022.pdf PDF
Attch 2 01 45 35 Statement of Special Inspections - 1 28 2022.pdf PDF
Attch 24 M801.pdf PDF
Attch 26 EL101.pdf PDF
Attch 23 M602.pdf PDF
Attch 17 FA101.pdf PDF
Attch 10 AD111.pdf PDF
Attch 5 01 50 02 00 50.pdf PDF
Attch 1 Project Table of Contents 00 00 00.pdf PDF
Attch 22 M601.pdf PDF
Attch 19 MH101.pdf PDF
Attch 16 A601.pdf PDF
Attch 15 A301.pdf PDF
Attch 14 A112.pdf PDF
Attch 9 AD102.pdf PDF
Attch 6 03 30 53.pdf PDF
Attch 21 MP101.pdf PDF
Attch 18 MD101.pdf PDF
Attch 13 A111.pdf PDF
Attch 8 AD101.pdf PDF
Attch 7 08 33 23.pdf PDF
W9123622B2041 Amendment 0005.pdf PDF
22B2041 B54 HVAC Amendment 4.pdf PDF
19 Jan Site visit.pdf PDF
Amendment 0003 Final.pdf PDF
Amendment 0002 Final.pdf PDF
Site Visit 5 January.pdf PDF
Amendment 0001 Final.pdf PDF
A.01.13_0455737 NAO663A B54-HVAC-ARTIFACT-IFB-DRAWINGS.pdf PDF
A.01.13_0455737 NAO663A B54-ARTIFACT-SPECS.pdf PDF
W9123622B2041 IFB.pdf PDF
Show all 43

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

26 27 28 29 30

J

K

10'-0"

8'-2"

M

AT

C H

LI

N

E

E1 /A

D

134110

131129128

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

, N

O R

FO

LK

, V A, D

R

AW

N B

Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

A C

T N

O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

SEALGRAPHIC SCALES

KEYPLAN

ARTIFACTS

A B

N

AO

F

IL

E N

O

3A

AD112

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

D

EM

O

LI

TI

O N

AR

EA

B

BU

IL

D

IN

G

4, JE

FF

ER

SO

N D

AV

IS

H W

Y, R

IC

H

M O

N D

VA

, 2

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

A, K.

O

LT

R . D

U C

H

ES

N E

K.

O

LT

M . D

E

PA

D U

A

O C

TO

B

ER

5, W

G

LG

W

6-

-D

-0

1-

BU

IL

D

IN

G

D

ES

IG

N F

O R

H

VA

C S

YS

TE

M S

IN

N

AV

Y

AR

TI

FA

C

T R

O O

M

SCALE: 1/8" = 1'-0"E1 REFLECTED CEILING PLAN - DEMOLITION - AREA B

0 4' 8' 16'

SCALE: 1/8" = 1'-0"

PLAN

NORTH

ROOM SQUARE FEET

NO. ROOM NAME AREA

110 DELTA ROOM 569 SF

111 HIGH DENSITY COMPACT STORAGE 5708 SF

122 CORRIDOR 488 SF

123 MECHANICAL ROOM 2683 SF

124 PRACTICE 470 SF

125 RECEIVING 812 SF

126 STORAGE 643 SF

128 JANITOR 75 SF

129 LAUNDRY 73 SF

130 ELECTRICAL ROOM 267 SF

131 CONSERVATION LAB 1075 SF

132 CONSERVATION LAB 295 SF

133 WOMEN'S 134 SF

134 MEN'S 129 SF

# DEMOLITION KEYNOTES

1 REMOVE AND DISPOSE OF ACOUSTICAL CEILING

PANELS COMPLETELY. RETAIN CEILING GRID

SYSTEM. AT THE CONTRACTORS DISCRETION, THE

CEILING GRID CAN BE REMOVED. STORAGE OF THE

GRID UNTIL REINSTALLATION SHALL BE AT THE

CONTRACTORS RISK. THE GRID SHALL BE STORED

WITHIN THE CONTRACTORS DESIGNATED

LAYDOWN AREA AND NOT LEFT EXPOSED TO THE

ELEMENTS.

2 EXIT SIGN TO REMAIN. REF ELEC FOR DEVICE

CHANGES

SHEET NOTES

1. COORDINATE THE REMOVAL AND REINSTALLATION OF

CEILING MOUNTED ITEMS WITH MEP & FP WORK.

AM