Attch 18 MD101.pdf
PDF 225 KB Posted
- Attached to
- DLA Building 54 Navy Artifact Restoration Federal contract opportunity
- Solicitation number
- W9123622B2041
About this file
This floor plan document is for the demolition of Building 54 at the DLA facility in Richmond, Virginia in preparation for HVAC system upgrades. The project involves removing an existing 40-ton air handling unit, condensing unit, return air fan, and associated ductwork and equipment. Refrigerant from demolished mechanical systems must be recovered and recycled according to EPA standards. Demolition will also remove four existing duct detectors from the room. The related federal contract opportunity is solicitation number W91236-22-B-2041 posted on December 7th seeking bids for restoration and HVAC work at the Navy Artifact facility in Building 54. The solicitation was issued by the Department of the Army Corps of Engineers Norfolk District for the DLA site.
View the file
Other files for this federal contract opportunity
Show all 43
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M M
M
24 25
J
K
22 23
36"x36"
16"x32"16"x32"
16"x12"
16"x32"
"x
, ETRBLR-1
, ETRBLR-2
, ETRP-2
, ETRP-1
CU-1
AHU-1
2 (TYP)
2 (TYP)
2-1/2" G RISER UP
FROM BELOW
GRADE, ETR
G
18"x18" UP TO
V-16, ETR
14"x14" UP TO
EF-42, ETR
28"x28" UP TO
EF-29, ETR
28"x28" UP TO
EF-30, ETR
, ETRUH-78
, ETRUH-80
, ETRUH-79
14"x14" UP TO
EF-28, ETR
20"x20" UP TO
SF-15, ETR
M A
T C
H L
IN
E
F /M
D
CAP 50"x50"
RELIEF UP TO V-15
HWR
HWS
HWS
HWR
HWR
HWS
REMOVE
EXISTING
CONCRETE PAD
FLOOR
DRAIN, ETR
1 1/2", ETR
DCW
REMOVE EXISTING 40 TON AIR HANDLING
UNIT, CONDENSING UNIT, RETURN AIR
FAN, DUCTWORK, INSULATION, AND
ASSOCIATED APPURTENANCES COMPLETE.
PATCH AND INFILL ROOF AND WALL
OPENING AS NEEDED.
REMOVE EXISTING DUCTWORK,
INSULATION, SUPPORTS, AND GRD’S
COMPLETE.
DISCONNECT HOT WATER PIPING AND
PREPARE FOR NEW COIL CONNECTION IN
NEW WORK.
DISCONNECT DUCTWORK FROM ROOF
VENT AND LOUVER AND PREPARE FOR
NEW DUCT CONNECTION IN NEW WORK.
THERE ARE FOUR (4) EXISTING DUCT
DETECTORS IN THIS ROOM (NOT SHOWN)
WHICH ARE TO BE REMOVED.
DEMOLITION KEYNOTES#
REFRIGERANT RECOVERY NOTE:
REFRIGERANT FROM EXISTING MECHANICAL SYSTEMS SHALL BE
RECOVERED AND RECYCLED FOR RECLAIM. EQUIPMENT CAPABLE
OF PULLING A VACUUM OF LESS THAN 1000 MICRONS OF MERCURY
SHALL BE USED TO RECOVER REFRIGERANT. MECHANICAL
SYSTEMS SHALL NOT BE OPENED TO ATMOSPHERE UNTIL ALL
REFRIGERANT IS FULLY RECOVERED. THE CONTRACTOR SHALL
PROVIDE CONTAINERS FOR THE STORAGE OF THE REFRIGERANT.
REFRIGERANT SHALL BECOME THE PROPERTY OF THE
CONTRACTOR.
A I
N I
G
RI
VFOHTLAE
W
N O
M M
O C
P R
O F
E
SS I ONAL ENG
I N E
E R
8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S N
O R
F O
L K
D
IS
T R
IC
T
F
R O
N T
S T
N
O R
F O
L K
V
A
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
SEALGRAPHIC SCALES
PLAN
NORTH
KEYPLAN
BRANDON E. WOOD
Lic. No. 35155
10/15/21
ARTIFACTS
A B
N A
O F
IL
E
N O
A
MD101
F L O
O R
P L A
N
A R
E A
A
D E
M O
L
IT
IO
N
B U
IL
D
IN
G
J
E F
F E
R S
O N
D A
V
IS
H W
Y R
IC
H
M O
N D
V
A
W S
P B
E N
D
IX
R D
S T
E
V
IR
G
IN
IA
B
E A
C H
V
A
J S
M
IT
H
C B
R A
N N
IN
G
K O
L T
B W
O O
D
O C
T
W G
L G
W
6-
-D
-0
1-
B U
IL
D
IN
G
D
E S
IG
N
F O
R H
V A
C S
Y S
T E
M S
I N
N A
V Y
A R
T
IF
A C
T R
O O
M
SCALE: 1/8" = 1'-0"
FLOOR PLAN – AREA A – DEMOLITION
F1
A
M E
N D
M E
N T
B
ID
D E
R I N
Q U
IR
IE
S
/3 /2
File details come from the government source that posted it. Updated .