Vol.1B_Revised_Sheet IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A.pdf
PDF 422 KB Posted
- Attached to
- Air Force Targeting Center, Langley AFB - Solicitation Federal contract opportunity
- Solicitation number
- W9123621R2005
About this file
This solicitation is for the construction of a new Targeting Center facility at Langley Air Force Base in Virginia. The scope of work includes constructing a permanent facility to accommodate the mission of analyzing intelligence, conducting surveillance and reconnaissance for the United States Air Force. The facility will be designed according to Department of Defense, Air Force and Langley standards and utilize local materials where cost-effective. It will also include emergency generators, site improvements, parking and supporting facilities. The facility must meet DoD minimum antiterrorism standards and incorporate sustainable building requirements. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Norfolk. Responses are due by the date specified in the solicitation documentation.
View the file
Other files for this federal contract opportunity
Show all 50
Air Force Targeting Center, Langley AFB - Solicitation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
D
6 7 8 9 10
G
C
E
F
VESTIBULE
100A
CPT-3
SSB-1
PT-1
WCT-1, GYP/PT-1
MAIN
LOBBY
PFT-1
SSB-1
PT-1/PT-4/DPF-1
WCT-1/PT-5
TOILET
100B
PFT-1
PT-1/CWT-1
GYP/PT-1
WING
SO
101A
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
SECURITY
OFFICE
RAF/CPT-2
RB-3
PT-1
ACT-1
WING
CCF
102G
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
WING
DO
102F
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
WING
CC
102D
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
WING
CV
102E
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
WING
CCC
102C
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
WING
DS
102B
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
WING
CONF.
ROOM
RAF/CPT-2
RB-3
AWP-1. PT-1
GYP/ PT-1, ACT-2
ISRW
COMMAND
GROUP
RAF/CPT-2
RB-3
PT-1
ACT-1
WING
CE
107N
RAF/CPT-1
RB-1
PT-1/PT-4/PT-2
ACT-1
WING
FM
107D
RAF/CPT-1
RB-1
PT-1/PT-2
ACT-1
WING
HC
107F
RAF/CPT-1
RB-1
PT-1/PT-4/PT-2
ACT-1
WING
HO
107G
RAF/CPT-1
RB-1
PT-1/PT-4/PT-2
ACT-1
WING
IG
107J
RAF/CPT-1
RB-1
PT-1/PT-2
ACT-1
WING
JA
107K
RAF/CPT-1
RB-1
PT-1/PT-4/PT-2
ACT-1
WING
LG
107M
RAF/CPT-1
RB-1
PT-1/PT-4/PT-2
ACT-1
WING
SE
107C
RAF/CPT-1
RB-1
PT-1/PT-2
ACT-1
WING
SC
107B
RAF/CPT-1
RB-1
PT-1/PT-2
ACT-1
WING
MS
107P
RAF/CPT-1
RB-1
PT-1/PT-4/PT-2
ACT-1
WING
XP
107H
RAF/CPT-1
RB-1
PT-1/PT-4/PT-2
ACT-1
ELECT
RAF-1
RB-2
PT-1
EXP
ISRW
OPS
GROUP
RAF/CPT-1
RB-1
PT-1/FP-1
PT-E/ ACB-1
ELEV.
#1 E101
PFT-1
SSB-1
PLAM-2
STAIR
#1 S101
CS-1
RB-2
PT-1
GYP/PT-1
WOMEN'S
TOILET
PFT-1
PT-1/CWT-1
GYP/ PT-1
D.3
B.5
SSO
INDOC
101B
RAF/CPT-2
RB-3
PT-1
ACT-1
A W
P -1
TEAM
RM
107E
RAF/CPT-1
RB-1
AWP-1/PT-1
ACT-1
M A
T C
H L
IN
E
S
E A
/IN
C
FP-1FP-1
DG-1
WDP-1 WDP-2 PT-4
B C
L -1
M A
T C
H L
E : A
/IN
B
DPF-1
W C
-1
WC-1
WC-1
W C
-1
WC-1
WC-1
A W
P -1
PT-4
FP-1FP-1
AWP-1
BCL-1
W C
-1
STORAGE
100C
CS-1
RB-2
PT-1
EXP./PT-1
WC-1
WING
TD
102A
RAF/CPT-2
RB-3
PT-1/WC-1
ACT-1
COPY
102J
RAF/RT-1
RB-3
PT-1
ACT-1
P T
-2
PT-2
PT-2
PT-2
AWP-1
P T
-2
P T
-2
P T
-2
P T
-2
P T
-2
P T
-2
P T
-2
DPF-2
STAIR
#5 S105
CS-1
RB-2
PT-1
GYP/PT-1
AWP-1
PT-4 PT-4 PT-4 PT-4 PT-4 PT-4
PT-4
PT-4
MAIN
CORRIDOR
PFT-1
SSB-1
VARIES
GYP/PT-1,
ACT-2/PT-5
RR-1
F7
A-535A
F7
A-535A
C7
A-535A
P T
-4
A5
A-522
MATCHLINE
SEE: A1/IN101C
M A
T C
H L
E : A
/IN
B
GENERAL FINISH NOTES
1. ALL WALLS PAINTED PT-1 U.N.O.
2. FLOORING MATERIAL TRANSITIONS SHALL OCCUR MID-
THRESHOLD AT DOORWAYS WHERE APPLICABLE.
3. PROVIDE TRANSITION STRIPS AND THRESHOLDS AS
REQUIRED.
4. MINIMIZE SEAMS PERPENDICULAR TO DOORWAYS AND
CASED OPENINGS.
5. SEE SHEET A-535A FOR FLOORING DETAILS,TRANSITIONS
AND TERMINATION DETAILS.
6. BEGIN FLOOR TILE INSTALLATION FROM CENTER OF ROOM
OUT TO PERIMETER.
7. PAINT MECHANICAL DIFFUSER/AIR GRILLE TO MATCH ADJ.
PARTITIONS.
8. STRUCTURAL STEEL PAINT TO MATCH ADJ. CEILING
9. PAINT PT-4 ACCENT WALLS AND ADJ. DOOR FRAMES U.N.O.
10. REFER TO SLAB EDGE PLANS A-111 AND A-112 FOR EXTENT
OF RAISED ACCESS FLOOR. WHERE RAISED ACCESS FLOOR
AND SLAB MEET CONTINUE FLOOR FINISHES AS INDICATED
ON FINISH PLANS.
FINISH KEY
RAF/CPT-1
RAF/CPT-2
PFT-1
RAF/RT-1
FLOOR MATERIAL TRANSITION
CEILING
WALL
BASE
FLOOR
ROOM FINISH TAG
ROOM NAME
ROOM NUMBER
FLOOR FINISH
BASE FINISH
WALL FINISH
CEILING FINISH
CS-1
CPT-3
XX
EXTENT OF WALL FINISH
CPT-2
RAF-1
FINISH CODE LEGEND
ACB ACOUSTIC CEILING BAFFLE
ACT ACOUSTIC CEILING TILE
AWP ACOUSTIC WALL PANEL
CPT CARPET TILE
CWT CERAMIC WALL TILE
CS CONCRETE SEALED
DG DECORATIVE GLASS
EM ENTRANCE MAT
GYP GYPSUM BOARD
FP FELT PANEL
HR HANDRAIL
MP METAL PANEL
MT METAL TRIM
PFT PORCELAIN FLOOR TILE
PL PLASTIC LAMINATE
PM PRESERVED MOSS
PT PAINT
PTB PORCELAIN TILE BASE
RAF RAISED ACCESS FLOOR WITH CONCRETE PAN
RB RUBBER BASE
RT RESILIENT TILE
SH ROLLER SHADE
SSB STAINLESS STEEL BASE
WCT WOOD CEILING TILE
WD HARDWOOD
WDP WOOD PANEL
WP WALL PROTECTION
KEY PLAN
C
A
86531
F
G
M A
T C
H L
IN
E
0 4'-0" 8'-0" 16'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
PROJECT
NORTH
TRUE
NORTH
J E
S S
IC
A
A N
D E
R S
O N
L A
N G
L E
Y A
F B
V
IR
G
IN
IA
L A
N G
L E
Y A
IR
F
O R
C E
T A
R G
E T
IN
G
F A
C
IL
IT
Y
H D
R
IN
C
W
A S
H
IN
G T
O N
B
L V
D S
U
IT
E
A R
L
IN
G T
O N
V
A
MAIN BLDG.
IN101A
IN
T
E R
IO
R
F
IN
IS
H
P L A
N
F
IR
S T
F L O
O R
A
R E
A A
E R
IN
C
O O
P E
R
C O
N L A
N N
O R
T H
C U
T T
E R
IN
C
O O
P E
R
/2 /2
W
-2
-R -2
READY TO ADVERTISE (RTA)
1/8" = 1'-0" A1
FIRST FLOOR FINISH PLAN - A
A m e n d m e n t
/1
/2
| Sheets |
| IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A |
File details come from the government source that posted it. Updated .