Vol.1B_Revised_Sheet A-607 - INTERIOR STOREFRONTS - LEVEL 2.pdf
PDF 217 KB Posted
- Attached to
- Air Force Targeting Center, Langley AFB - Solicitation Federal contract opportunity
- Solicitation number
- W9123621R2005
About this file
This document package includes construction drawings and specifications for an interior storefront renovation project at the Air Force Targeting Center Facility at Langley Air Force Base in Virginia. The project involves installing new interior storefront systems on Level 2, including glazed aluminum framing and doors. Fifteen different storefront locations are scheduled and detailed on the drawings. Acoustic and security requirements are specified, with Sound Transmission Class ratings of 40-45 and glazing types GL-5 and GL-6. The solicitation was issued by the U.S. Army Corps of Engineers Norfolk District for the Air Force. Offerors are required to design and construct the project in accordance with Department of Defense, Air Force, and Langley standards and criteria.
View the file
Other files for this federal contract opportunity
Show all 50
Air Force Targeting Center, Langley AFB - Solicitation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S210
4 EQ PANELS
9'-6 1/4"
26'-5 1/8"2'-0"16'-3 7/8"
AS SCHED
DOOR
CENTER MULLION ON
PARTITION BEHIND
7 EQ1 PANELS
AS SCHED
DOOREQ1EQ1
S209 S208
D O
O R
A S
S C
H E
D
4 EQ PANELS2'-7"
16'-6 3/4"
S211 S212
3 EQ PANELS2 EQ PANELS
AS SCHED
DOOR
CENTER MULLION ON
PARTITION BEHIND
3 EQ PANELS
8'-8 1/2"7'-6 5/8"9'-0 1/8"
T Y
P
T Y
P
DF-2
11'-11 1/4"
EQDOOR AS SCHEDEQ
D O
O R
A S
S C
H E
D
5'-0"
AS SCHED
DOOR
D O
O R
A S
S C
H E
D
6'-7"
AS SCHED
DOOR
D O
O R
A S
S C
H E
D
6'-7 3/4"
AS SCHED
DOOR
D O
O R
A S
S C
H E
D
4'-11 3/4"
D O
O R
A S
S C
H E
D
AS SCHED
DOOR
10'-4 7/8"
EQDOOR AS SCHEDEQ
D O
O R
A S
S C
H E
D
10'-0"
AS SCHED
DOOR 2 EQ PANELS
5 EQ PANELS
16'-6 3/4"
3 EQ PANELS
9'-0 7/8"
C5
A-545
AS SCHED
DOOR 3 EQ PANELS
13'-9 3/8"
D O
O R
A S
S C
H E
D C5
A-545
DF-1
11'-7 1/2"
AS SCHED
DOOR 3 EQ. PANELS
0 2'-0" 4'-0" 8'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
J E
S S
IC
A
A N
D E
R S
O N
L A
N G
L E
Y A
F B
V
IR
G
IN
IA
L A
N G
L E
Y A
IR
F
O R
C E
T A
R G
E T
IN
G
F A
C
IL
IT
Y
H D
R
IN
C
W
A S
H
IN
G T
O N
B
L V
D S
U
IT
E
A R
L
IN
G T
O N
V
A
MAIN BLDG.
A-607
I N T
E R
IO
R
S T
O R
E F
R O
N T
S
L E
V E
L
E R
IN
C
O O
P E
R
J O
N A
T H
A N
O S
W A
L D
E R
IN
C
O O
P E
R
/2 /2
W
-2
-R -2
READY TO ADVERTISE (RTA)
1/4" = 1'-0" C4
S208 / S209 / S210
1/4" = 1'-0" E1
S211 / S212
1/4" = 1'-0" A1
S201 1/4" = 1'-0"
A3 S202
1/4" = 1'-0" A4
S203 1/4" = 1'-0"
A5 S204
1/4" = 1'-0" A7
S205 1/4" = 1'-0"
A8 S206
1/4" = 1'-0" E4
S213 1/4" = 1'-0"
E6 S214
1/4" = 1'-0" C3
S207B 1/4" = 1'-0"
C1 S207A
INTERIOR STOREFRONT SCHEDULE - LEVEL 2
MARK STC GLAZING FILM TYPE
S201 40 GL-5 DF-2
S202 40 GL-5 DF-2
S203 40 GL-5 DF-2
S204 40 GL-5 DF-2
S205 40 GL-5 DF-2
S206 40 GL-5 DF-2
S207A 40 GL-5 DF-1
S207B 40 GL-5 DF-1
S208 45 GL-6 DF-1
S209 45 GL-6 DF-1
S210 40 GL-5 DF-1
S211 40 GL-5 DF-2
S212 40 GL-5 DF-2
S213 40 GL-5 DF-2
S214 40 GL-5 DF-2
S215 40 GL-5 DF-2
1/4" = 1'-0" E8
S215
A m e n d m e n t
/1
/2
| Sheets |
| A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM |
| A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD |
| A-601 - DOOR SCHEDULE - LEVEL 1 |
| A-602 - DOOR SCHEDULE - LEVEL 2 |
| A-607 - INTERIOR STOREFRONTS - LEVEL 2 |
| I-001 - INTERIOR NOTES AND FINISH LEGEND |
| IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A |
| IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C |
File details come from the government source that posted it. Updated .