Vol.1B_Revised_Sheet A-602 - DOOR SCHEDULE - LEVEL 2.pdf

PDF 230 KB Posted

Attached to
Air Force Targeting Center, Langley AFB - Solicitation Federal contract opportunity
Solicitation number
W9123621R2005
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document package includes a door schedule and specifications for the Air Force Targeting Center Facility project at Langley Air Force Base. The door schedule provides details on over 50 doors and frames on Level 2, including dimensions, materials, fire ratings, sound transmission class ratings, and notes. Frame details and hardware sets are referenced on other drawings. The project will construct a new facility for the 25th Air Force to support intelligence, surveillance, and reconnaissance operations. The solicitation specifies construction of a permanent facility in accordance with military standards, including emergency power and site improvements. Local materials and standard construction methods will be used where cost-effective.

View the file

Other files for this federal contract opportunity

Other files attached to Air Force Targeting Center, Langley AFB - Solicitation, newest first.
File Type Posted
W9123621R2005 Amendment 0008.pdf PDF
Vol.1A_Revised_Sheet CD-101 DEMOLITION PLAN.pdf PDF
Specs_V1_Revised_Appendix_B_ESS.pdf PDF
Vol.1A_Revised_Sheet CD-102 DEMOLITION PLAN.pdf PDF
Specs_V1_Revised_01 33 00.00 50.pdf PDF
W9123621R2005 0007.pdf PDF
Vol.1B_Revised_Sheet A-313 - EXTERIOR WALL SECTIONS.pdf PDF
Specs_V2_Revised_10 22 19.pdf PDF
Specs_V1_Revised_02 60 00.pdf PDF
Specs_V2_Revised_08 71 00.pdf PDF
Vol.1B_Revised_Sheet I-001 INTERIOR NOTES AN FINISH LEGEND .pdf PDF
Vol.1B_Revised_Sheet A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM.pdf PDF
Specs_V3_Revised_22 00 00.pdf PDF
W9123621R2005 0006.pdf PDF
Vol.1B_Revised_Sheet IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A.pdf PDF
Vol.1B_Revised_Sheet A-607 - INTERIOR STOREFRONTS - LEVEL 2.pdf PDF
Vol.1B_Revised_Sheet A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD.pdf PDF
Vol.1A_Revised_Sheet X-002 TRAFFIC DETAILS.pdf PDF
Vol.1A_Revised_Sheet CG-113 EROSION & SEDIMENT CONTORL DETAIL SHEET.pdf PDF
Vol.1A_Revised_Sheet CG-112 EROSION & SEDIMENT CONTORL DETAIL SHEET.pdf PDF
Vol.1B_Revised_Sheet IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C.pdf PDF
Vol.1A_Revised_Sheet CG-111 EROSION & SEDIMENT CONTORL DETAIL SHEET.pdf PDF
Langley Furniture Qty.pdf PDF
W9123621R2005 0005.pdf PDF
FINAL_LAFB_TCF_Norfolk_District_USACE_Geotechnical_Report.pdf PDF
W9123621R2005 0004.pdf PDF
2020RTA_AFTC_Vol.1A.pdf PDF
20201124_RTA_Specs_V2_Div_07-14_Consolidated.pdf PDF
20201124_RTA_Specs_V1_Div_00-06_Consolidated.pdf PDF
Site Visit Roster_AF Targeting Center 21R2005.pdf PDF
W9123621R20050002.pdf PDF
A.02.01 Amendment 0001 Solicitation 21R2005_released.pdf PDF
A.02.01 Solicitation W9123621R2005_released 11.03.2020.pdf PDF
B.02.09 Att. 1 Proposal Data Sheet.pdf PDF
B.02.09 Att. 4 Telephone Interview Questionnaire (For Government Use Only).pdf PDF
B.02.09 Att. 8 CLIN Schedule.pdf PDF
20191115_IFC_Specs_V3_Div_21-25.pdf PDF
B.02.09 Att. 3 Past Performance Questionaire.pdf PDF
B.02.09 Att. 5 Letter of Commitment Sample.pdf PDF
B.02.09 Att. 6 Small Business Subcontracting Record.pdf PDF
20191115_AFTC_IFC_Vol.1B.pdf PDF
20191115_AFTC_IFC_Vol.2.pdf PDF
20190411_Furniture_specification_package_Amendment_2 (1).pdf PDF
B.02.09 Att. 2 Company Specialized Experience.pdf PDF
B.02.09 Att. 7 Small Business Participation Plan.pdf PDF
20191115_AFTC_IFC_Vol.1A (Full Scale).pdf PDF
20191115_IFC_Specs_V2_Div_07-14.pdf PDF
20191115_IFC_Specs_V4_Div_26-33_Appendix.pdf PDF
20191115_IFC_Specs_V1_Div_00-06.pdf PDF
JBLE-Langley AF TCF - NTCRA ESS Construction Support (20181115) DRAFT.pdf PDF
Show all 50

Air Force Targeting Center, Langley AFB - Solicitation has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR SCHEDULE LEGEND

AL ALUMINUM

ANOD ANODIZED

GL-# GLAZING, RE: SPEC

GP-# DECORATIVE GLAZING, RE: FINISH LEGEND

HM HOLLOW METAL

STL STEEL

STN STAINED WOOD

PT PAINT

WD WOOD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S

O F

E N

G

IN

E E

R S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

UNCLASSIFIED\\FOR OFFICIAL USE ONLY

UNCLASSIFIED\\FOR OFFICIAL USE ONLY

J E

S S

IC

A

A N

D E

R S

O N

L A

N G

L E

Y A

F B

V

IR

G

IN

IA

L A

N G

L E

Y A

IR

F

O R

C E

T A

R G

E T

IN

G

F A

C

IL

IT

Y

H D

R

IN

C

W

A S

H

IN

G T

O N

B

L V

D S

U

IT

E

A R

L

IN

G T

O N

V

A

MAIN BLDG.

A-602

D O

O R

S C

H E

D U

L E

L

E V

E L

J E

F F

R E

Y G

E T

T Y

E R

IC

H

O F

M A

N N

A P

R

IL

D R

A K

E

/2 /2

W

-2

-R -2

READY TO ADVERTISE (RTA)

DOOR AND FRAME SCHEDULE - LEVEL 2

IDENTIFICATION DIMENSIONS PANEL FRAME

FIRE

RATING

(MIN)

STC

RATING

HARDWARE

SET NOTES

ROOM

NO. ROOM NAME DOOR NO.

WIDTH

H

PANEL

COUNT TYPE MATERIAL FINISH TYPE MATERIAL FINISH

FRAME DETAIL

W1 W2

TOTAL

WIDTH HEAD JAMB SILL

201 CA-III CONF 201.1 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 17 NOTE 2, 8

202 CA-III 202.1 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 17 NOTE 2, 8

202 CA-III 202.2 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 16

202B ELEV. RM 202B 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 0 0 46

203 15 IS OPS GROUP 203.1 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 38 NOTE 6

203 15 IS OPS GROUP 203.2 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 49 NOTE 6

203C CA-III 203C 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 17 NOTE 2, 8

203D CA OFFICE 203D 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15 NOTE 8

203E CA OFFICE 203E 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15 NOTE 8

204 ELECT 204 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 20 NOTES 2, 3

205 15 IS COMMAND GROUP 205 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-7 N/A 1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 41

205A IS CCF 205A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

205B IS CCS 205B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

205C IS CC 205C 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

206 17 IS GROUP COMMAND 206 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-7 N/A 1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 41

206A IS CC 206A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

206B IS CCS 206B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

206C IS CCF 206C 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

207 ART OFFICE 207 3' - 0" 3' - 0" 6' - 0" 9' - 10" 2 DG/DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 40 40

207A ART OFFICE 207A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 40 15

207B ART OFFICE 207B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 40 15

208 WOMEN'S TOILET 208 3' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 0 0 24

209 MEN'S TOILET 209 3' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 0 0 24

210 J.C. 210 3' - 0" 10' - 0" 1 F WD GL 2 AL ANOD C5/A-604 A5/A-604 - 0 0 46 NOTE 2

211 SHARED TEAM 211 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 40 23 NOTE 6

212 SHARED TEAM 212 3' - 0" 8' - 0" 1 DG GL-5 N/A 1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 40 23

213 COPY AREA 213 4' - 0" 8' - 0" 1 N/A N/A N/A 3 HM PT C7/A-604 A7/A-604 - 0 0 43

214 CONF. RM 214.1 3' - 0" 10' - 0" 1 F STL STN 1 STL PT C5/A-604 A5/A-604 - 0 50 21 NOTE 8

214 CONF. RM 214.2 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 21 NOTE 8

215 17 OPS GROUP 215.1 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 49 NOTE 6

215 17 OPS GROUP 215.2 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 49 NOTE 6

215A TEAM RM 215A 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F/F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 40 50

215B IS SR CIV 215B 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

215C IS DO 215C 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

215D IS SR CIV 215D 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

215E IS DO 215E 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

216 ELECT 216 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 20 NOTES 2, 3

217 TRAINING RM 217.1 3' - 0" 9' - 10" 1 DG GL-8 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 45 23 NOTE 6

217 TRAINING RM 217.2 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 35 23

218 TEAM RM 218 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 23 NOTE 2, 8

219 CONF. RM 219 3' - 0" 9' - 10" 1 DG GL-8 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 45 42 NOTE 6

220 SERVER RM 220 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 13

221 42 IS COMMAND GROUP 221 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-5 N/A 1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 41

221A IS CC 221A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

221B IS CCS 221B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

221C IS CCF 221C 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

222 ELECT 222 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 20 NOTES 2, 3

223 36 IS/42 IS OPS GROUP 223.1 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 49 NOTE 6

223 36 IS/42 IS OPS GROUP 223.2 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 38

223A TEAM RM 223A 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F/F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 50

223B IS SR CIV 223B 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

223C IS DO 223C 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

224 36 IS COMMAND GROUP 224 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-7 N/A 1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 41

224A IS CC 224A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

224B IS CCS 224B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

224C IS CCF 224C 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

224D ELEV. RM 224D 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 0 0 46

225 VTC ROOM 225 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 48 NOTE 2, 8

229 STORAGE 229 3' - 0" 7' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 46 NOTE 1, 2

230 NURSING MOTHERS 230 3' - 0" 7' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 47 NOTE 1, 2

232 MEN'S SHOWERS 232 3' - 0" 7' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 24 NOTE 1

233 WOMEN'S SHOWERS 233 3' - 0" 7' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 24 NOTE 1

S101 STAIR #1 S201 4' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 45 0 45

S202 STAIR #2 S202 3' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 45 0 45

S203 STAIR #3 S203 4' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 45 0 45

S205 STAIR #5 S205 4' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 45 0 45

8. WOOD VENEER ON METAL DOOR

7. BLAST-RESISTANT DOOR - RE: BLAST REPORT

6. DOOR IS PART OF DEMOUNTABLE PARTITION SYSTEM

5. DOOR POSITION SWITCH

4. NOT USED

3. 180 DEGREE SWING

2. CARD READER

1. 3/8" UNDERCUT

DOOR SCHEDULE SHEET NOTES

5. ALL EXTERIOR DOORS SHALL ACHIEVE A MINIMUM OITC OF

35 UNLESS NOTED OTHERWISE.

4. INDICATED DOORS AND FRAMES TO BE PT-1 TYP.

3. REFER TO A-604 FOR TYPICAL DOOR AND FRAME DETAILS.

2. REFER TO A-603 FOR INTERIOR DOOR AND FRAME TYPES.

1. REFER TO PROJECT SPECIFICATIONS FOR COMPLETE LIST

OF HARDWARE IN EACH GROUP.

DOOR SCHEDULE GENERAL NOTES

A m e n d m e n t

/1

/2

Sheets
A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM
A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD
A-601 - DOOR SCHEDULE - LEVEL 1
A-602 - DOOR SCHEDULE - LEVEL 2
A-607 - INTERIOR STOREFRONTS - LEVEL 2
I-001 - INTERIOR NOTES AND FINISH LEGEND
IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A
IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C

File details come from the government source that posted it. Updated .