Vol.1B_Revised_Sheet A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM.pdf

PDF 419 KB Posted

Attached to
Air Force Targeting Center, Langley AFB - Solicitation
Solicitation number
W9123621R2005
Issued by

About this file

This document package includes construction plans and specifications for shower and nursing room renovations at the Air Force Targeting Center facility at Langley Air Force Base in Virginia, as well as the related federal contract solicitation. The construction plans detail layouts, dimensions, and finishes for the men's and women's showers, nursing room, and surrounding areas. Renovations include new plumbing fixtures, flooring, walls, and ceilings. The solicitation was issued by the U.S. Army Corps of Engineers for design and construction services. The selected contractor will upgrade the shower and nursing facilities to support operations at the Air Force Targeting Center and meet all applicable military, Air Force, and antiterrorism standards. The solicitation closes on November 24, 2020 and includes requirements for emergency power, site work, and parking to fully implement the renovations.

View the file

Other files

File Type Posted
W9123621R2005 Amendment 0008.pdf PDF
Specs_V1_Revised_Appendix_B_ESS.pdf PDF
Specs_V2_Revised_08 71 00.pdf PDF
Vol.1A_Revised_Sheet CD-102 DEMOLITION PLAN.pdf PDF
Specs_V1_Revised_01 33 00.00 50.pdf PDF
Vol.1A_Revised_Sheet CD-101 DEMOLITION PLAN.pdf PDF
W9123621R2005 0007.pdf PDF
Specs_V1_Revsied_00 00 00_TOC.pdf PDF
Specs_V2_Revised_10 22 19.pdf PDF
Vol.1B_Revised_Sheet A-313 - EXTERIOR WALL SECTIONS.pdf PDF
Specs_V1_Revised_02 60 00.pdf PDF
W9123621R2005 0006.pdf PDF
Vol.1A_Revised_Sheet CG-113 EROSION & SEDIMENT CONTORL DETAIL SHEET.pdf PDF
Vol.1A_Revised_Sheet CG-112 EROSION & SEDIMENT CONTORL DETAIL SHEET.pdf PDF
Vol.1B_Revised_Sheet IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A.pdf PDF
Specs_V1_Revised_00 00 00_TOC.pdf PDF
Vol.1B_Revised_Sheet A-602 - DOOR SCHEDULE - LEVEL 2.pdf PDF
Vol.1B_Revised_Sheet A-601 - DOOR SCHEDULE - LEVEL 1.pdf PDF
Vol.1B_Revised_Sheet A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD.pdf PDF
Vol.1B_Revised_Sheet I-001 INTERIOR NOTES AN FINISH LEGEND .pdf PDF
Vol.1A_Revised_Sheet X-002 TRAFFIC DETAILS.pdf PDF
Specs_V3_Revised_22 00 00.pdf PDF
Vol.1B_Revised_Sheet A-607 - INTERIOR STOREFRONTS - LEVEL 2.pdf PDF
Specs_V2_Revised_08 81 00.pdf PDF
Langley Furniture Qty.pdf PDF
Vol.1B_Revised_Sheet IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C.pdf PDF
Vol.1A_Revised_Sheet CG-111 EROSION & SEDIMENT CONTORL DETAIL SHEET.pdf PDF
W9123621R2005 0005.pdf PDF
FINAL_LAFB_TCF_Norfolk_District_USACE_Geotechnical_Report.pdf PDF
W9123621R2005 0004.pdf PDF
W9123621R20050003.pdf PDF
20201124_RTA_Specs_V4_Div_26-33_Appendix_Consolidated.pdf PDF
2020RTA_AFTC_Vol.1B.pdf PDF
2020RTA_AFTC_Vol.1A.pdf PDF
20201124_RTA_Specs_V2_Div_07-14_Consolidated.pdf PDF
20201124_RTA_Specs_V1_Div_00-06_Consolidated.pdf PDF
2020RTA_AFTC_Vol.2.pdf PDF
20201124_RTA_Specs_V3_Div_21-25_Consolidated.pdf PDF
W9123621R20050002.pdf PDF
Site Visit Roster_AF Targeting Center 21R2005.pdf PDF
A.02.01 Amendment 0001 Solicitation 21R2005_released.pdf PDF
A.02.01 Solicitation W9123621R2005_released 11.03.2020.pdf PDF
B.02.09 Att. 3 Past Performance Questionaire.pdf PDF
20191115_IFC_Specs_V2_Div_07-14.pdf PDF
20191115_IFC_Specs_V1_Div_00-06.pdf PDF
20191115_IFC_Specs_V4_Div_26-33_Appendix.pdf PDF
B.02.09 Att. 7 Small Business Participation Plan.pdf PDF
20191115_AFTC_IFC_Vol.2.pdf PDF
20191115_AFTC_IFC_Vol.1A (Full Scale).pdf PDF
B.02.09 Att. 2 Company Specialized Experience.pdf PDF
Show 40 more

Latest 50 of 59 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

OC3

OC3

'-0

A-530

F1

CWT-1

V.I.F. 3'-3"

3'-3" V.I.F.

V.I.F. 3'-3"

CWT-1

'-0

'-0

08D

3'-3"

CWT-1

E8

A-413

TA8B

TA7

08D

V.I.F. 3'-3" 3'-3" 3'-3" 3'-3" 3'-3" 3'-3"

CWT-1

V.I.F.

'-1

'-3

E8

A-413

TA8B

'-0

TA7

CWT-1

3'-3" 3'-3" 3'-3" V.I.F.3'-3" 3'-3" V.I.F.

'-1

'-3

'-1

'-0

'-4

TA9V

7'-7 7/8"

REF

2'-0"

155 - SINK

3'-6"

101M

2'-0"FULL WIDTH

END PANEL

FILLER PANEL

(TYP)

EQF-1

PLAM-1

4" BACKSPLASH

TA7

CC

BB

A7

A-311

STORAGE

229229

CORRIDOR

231231

MEN'S

SHOWERS

232232

WOMEN'S

SHOWERS

233233

NURSING

MOTHERS

230230

229 230

A-411

D8

A-411A

A1

A

A6

A-411 C

'-8

/2

'-6

'-9

'-4

'-4

'-7

/2

SH2SH2

SH2

SH1 SH1

E8

A-413

B3

S

U

UCS6

U3

A3S3

A

S3

U3

A

U

B

U C

S

S3

S

S3

S3

S

B3

S3

S

S

S3

S

B

A

U C

S

C L E

A R

'-0

C L E

A R

'-0

/2

'-0

/2

'-6

'-9

'-5

'-3

'-1

'-1

'-0

/2

'-8

'-2

L1

A-411

A1

A6

A3

A-522

U3

5'-7"5'-0" 5'-7"

S1 S2

S4

TA13T

TA7

TA8B

TA7

TA8B

U C

S

TA17ATA17A

5'-1"

C L '-2

3'-7" 10'-8 1/2" 6'-8 1/2" 5'-1" 3'-3 1/2"

'-4

10 1/2" 7'-1 1/2"

S2

TA13T

A

1'-3 1/2"

U6

U3 S3 S6

UCS6

S6

1'-10 1/2"

C

B

B.5

A9

A-532

EQ EQ

E Q

E Q

3'-5" 3'-5"

2'-9"

4'-4" 6'-0" 5'-3 1/2"

'-2

'-9

'-3

/2

'-6

1'-7"

EQ EQ

E Q

E Q

F1

A-530

F1

A-530

NURSING

MOTHERS

230230

WOMEN'S

SHOWERS

GYP/ PT-1

MEN'S

SHOWERS

GYP/ PT-1

CORRIDOR

231231

STORAGE

229229

8' - 0"

8' - 0"

2'-4 1/2" 2'-7 1/2"

'-8

/2

'-4

3'-10 1/2"

1'-6"

'-2

/2

'-6

'-7

/2

'-6

'-8

/2

'-4

1'-9"

0 2'-0" 4'-0" 8'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S

O F

E N

G

IN

E E

R S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

UNCLASSIFIED\\FOR OFFICIAL USE ONLY

UNCLASSIFIED\\FOR OFFICIAL USE ONLY

J E

S S

IC

A

A N

D E

R S

O N

L A

N G

L E

Y A

F B

V

IR

G

IN

IA

L A

N G

L E

Y A

IR

F

O R

C E

T A

R G

E T

IN

G

F A

C

IL

IT

Y

H D

R

IN

C

W

A S

H

IN

G T

O N

B

L V

D S

U

IT

E

A R

L

IN

G T

O N

V

A

MAIN BLDG.

A-411

E N

L A

R G

E D

P L A

N S

A N

D E

L E

V A

T

IO

N S

S

H O

W E

R S

A N

D N

U R

S

IN

G R

O O

M

E R

IN

C

O O

P E

R

E R

IC

H

O F

M A

N N

A P

R

IL

D R

A K

E

/2 /2

W

-2

-R -2

READY TO ADVERTISE (RTA)

1/4" = 1'-0" A1

SHOWER EAST ELEVATION

1/4" = 1'-0"

A3

SHOWER SOUTH ELEVATION

1/4" = 1'-0" A6

SHOWER WEST ELEVATION

1/4" = 1'-0"

A8

MEN'S SHOWER NORTH ELEVATION

1/4" = 1'-0" C8

WOMEN'S SHOWERS SOUTH ELEVATION

1/4" = 1'-0" D8

230-NURSING MOTHERS-ELEV-WEST

KEYNOTES - TOILET ACCESSORIES

TA7 PAPER TOWEL DISPENSER, SURFACE MOUNTED

TA8B WASTE RECEPTACLE, SEMI-RECESSED

TA9V SOAP DISPENSER, SURFACE MOUNTED VERTICAL W/

SENSOR

TA13T MIRROR, 24"X60"

TA17A SHOWER SEAT, SWING DOWN LEGS 900#

1/4" = 1'-0" C1

ENLARGED TOILETS AND SHOWERS 230 & 231

1/4" = 1'-0"

C5

02-A-CEILING PLAN - AREA C - SHOWER

A m e n d m e n t

/1

/2

Sheets
A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM
A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD
A-601 - DOOR SCHEDULE - LEVEL 1
A-602 - DOOR SCHEDULE - LEVEL 2
A-607 - INTERIOR STOREFRONTS - LEVEL 2
I-001 - INTERIOR NOTES AND FINISH LEGEND
IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A
IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C

File details come from the government source that posted it. Updated .