Vol.1B_Revised_Sheet A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD.pdf
PDF 295 KB Posted
- Solicitation number
- W9123621R2005
About this file
This solicitation is for design and construction services for an Air Force Targeting Center Facility at Langley Air Force Base in Virginia. The scope of work includes constructing a new facility to accommodate the mission of housing the 25th Air Force's targeting operations utilizing conventional design and construction methods. The facility must meet DoD, Air Force, and Langley standards and be designed as a permanent structure in compliance with UFC facility criteria including minimum antiterrorism standards. Associated requirements involve emergency generators, site improvements, special foundations, parking, and supporting facilities. Responses were due by November 24, 2020, with the Army Corps of Engineers District Norfolk listed as the contracting agency overseeing the project.
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARTITION AS SCHEDULED
MOUNTING EXTRUSION
ACOUSTIC FABRIC
PANEL, TYP.
PARTITION AS
SCHEDULED
MOUNTING
EXTRUSION
ACOUSTIC FABRIC
PANEL, TYP.
MOUNTING EXTRUSION,
PAINTED, PT-4.
CEILING AS
SCHEDULED
ACOUSTIC FABRIC
PANEL, TYP.
PLASMA SCREEN-
GFGI
PLASMA SCREEN
MOUNTING PLATE
PROVIDE ADEQUATE
VENTILATION SPACE
PER MANUFACTURERS
RECOMMENDATION.
PAINTED GYP. BD.
WALL FINISH. RE:
FINISH PLANS.
R E
: E
LE
V S
R E
: E
LE
V S
PAINTED GYP. BD.
WALL FINISH. RE:
FINISH PLANS.
ACOUSTIC FABRIC
PANEL, TYP.
MOUNTING EXTRUSION,
PAINTED, PT-4.
1/4" REVEAL
PARTITION AS
SCHEDULED
MOUNTING
EXTRUSION,
PAINTED.
ACOUSTIC FABRIC
PANEL, TYP.
TYP.
A-521
B7
3/4" 3/4"
1 1/2"
WOOD PANEL FACE
Z-CLIPS AS REQUIRED
BLOCKING AS REQUIRED
PARTITION AS SCHEDULED
1/ 2"
M
IN
WOOD PANEL FACE
BLOCKING AS
REQUIRED
Z-CLIPS FIELD
INSTALLED
PARTITION AS
SCHEDULED
MATCHING
VENEER
EDGE BAND
*REQUIRED SPACE TO
INSTALL AND ENGAGE
PANEL ONTO Z-CLIPS
PARTITION AS
SCHEDULED.
MOUNTING
EXTRUSION,
PAINTED.
ACOUSTIC FABRIC
PANEL, TYP.
1"
BLOCKING BEHIND BASE
AS SCHEDULED.
FLOOR FINISH AS
SCHEDULED.
BASE AS SCHEDULED
WOOD PANEL FACE
BLOCKING AS
REQUIRED
Z-CLIPS FIELD
INSTALLED
PARTITION AS
SCHEDULED
MATCHING
VENEER
EDGE BAND
*TYPICAL DIMENSION
APPLIES AT ALL HORIZONTAL
AND VERTICAL REVEALS.
3/ 8"
T Y
P
3/ 8"
T Y
P
*TYPICAL DIMENSION
APPLIES AT ALL CORNERS.
ALIGN
MATCHING
VENEER
EDGE BAND
Z-CLIPS FIELD
INSTALLED
BLOCKING AS
REQUIRED
PARTITION AS
SCHEDULED
WOOD PANEL FACE
OUTSIDE EDGE
TRIM PAINTED, PT-4
*TYPICAL DIMENSION
APPLIES AT ALL SOFFIT
CONDITIONS.
ALIGN
Z-CLIPS FIELD
INSTALLED
BLOCKING AS
REQUIRED
PARTITION AS
SCHEDULED
WOOD PANEL
FACE
CEILING AS
SCHEDULED 3/8" TYP.
OUTSIDE EGDE TRIM
PAINTED, PT-4
5/ 8"
R E
V E
A L
WOOD PANEL FACE
BLOCKING AS
REQUIRED
Z-CLIPS FIELD
INSTALLED
PARTITION AS
SCHEDULED
MATCHING
VENEER
EDGE BAND
*5/8" HORIZONTAL REVEAL
ONLY OCCURS ON SECOND
FLOOR.
REVEAL
PAINTED TO
MATCH FINISH.
WOOD PANEL FACE
BLOCKING AS
REQUIRED
Z-CLIPS FIELD
INSTALLED
PARTITION AS
SCHEDULED
MATCHING
VENEER
EDGE BAND
1/
2" FLOOR FINISH AS
SCHEDULED
MOUNTING EXTRUSION,
PAINTED.
CEILING AS
SCHEDULED
ACOUSTIC FABRIC
PANEL, TYP.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
J E
S S
IC
A
A N
D E
R S
O N
L A
N G
L E
Y A
F B
V
IR
G
IN
IA
L A
N G
L E
Y A
IR
F
O R
C E
T A
R G
E T
IN
G
F A
C
IL
IT
Y
H D
R
IN
C
W
A S
H
IN
G T
O N
B
L V
D S
U
IT
E
A R
L
IN
G T
O N
V
A
MAIN BLDG.
A-521
D E
T A
IL
S
I N
T E
R
IO
R
A C
O U
S T
IC
W O
O D
E R
IN
C
O O
P E
R
E R
IC
H
O F
M A
N N
A P
R
IL
D R
A K
E
/2 /2
W
-2
-R -2
READY TO ADVERTISE (RTA)
6" = 1'-0" A1
ACOUSTICAL PANEL EDGE @ INSIDE CORNER- TYP.
6" = 1'-0"
A4
ACOUSTICAL PANEL HORIZONTAL MIDSEAM FABRIC SECTION- TYP.
6" = 1'-0" D1
ACOUSTICAL PANEL EDGE @ MONITOR LOCATIONS
6" = 1'-0" B4
ACOUSTICAL PANEL VERTICAL MIDSEAM FABRIC SECTION- TYP.
3" = 1'-0" A9
WOOD PANEL Z-CLIP MOUNTING DETAIL
3" = 1'-0" B7
WOOD PANEL Z-CLIP MOUNTING DETAIL-TOP
6" = 1'-0"
B1
ACOUSTICAL PANEL EDGE @ BASE OF WALL
3" = 1'-0" E7
WOOD PANEL Z-CLIP MOUNTING DETAIL-REVEAL
3" = 1'-0" F7
WOOD PANEL Z-CLIP MOUNTING DETAIL-CORNER
3" = 1'-0"
F9
WOOD PANEL Z-CLIP MOUNTING DETAIL-SOFFIT
3" = 1'-0" C7
WOOD PANEL Z-CLIP MOUNTING DETAIL-TOP REVEAL
3" = 1'-0" A7
WOOD PANEL Z-CLIP MOUNTING DETAIL-BASE
6" = 1'-0" C4
ACOUSTICAL PANEL EDGE @ TOP OF WALL
A m e n d m e n t
/1
/2
| Sheets |
| A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM |
| A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD |
| A-601 - DOOR SCHEDULE - LEVEL 1 |
| A-602 - DOOR SCHEDULE - LEVEL 2 |
| A-607 - INTERIOR STOREFRONTS - LEVEL 2 |
| I-001 - INTERIOR NOTES AND FINISH LEGEND |
| IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A |
| IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C |
File details come from the government source that posted it. Updated .