Specs_V2_Revised_08 71 00.pdf
PDF 94 KB Posted
- Attached to
- Air Force Targeting Center, Langley AFB - Solicitation Federal contract opportunity
- Solicitation number
- W9123621R2005
About this file
This solicitation requests proposals for the construction of an Air Force Targeting Center facility at Langley Air Force Base. The scope of work includes building a new facility to accommodate the mission of housing a single reach-back targeting threat and analysis capability for the United States Air Force. The facility will be designed according to DoD and Air Force standards and include emergency generators, site improvements, parking, and supporting facilities. Proposals are due by the date specified in the solicitation, and the contract will be awarded thereafter. The project aims to provide a suitable building to support the standing up of a new Intelligence, Surveillance, and Reconnaissance Wing for command and control of Air Force target and threat analysis functions.
View the file
Other files for this federal contract opportunity
Show all 50
Air Force Targeting Center, Langley AFB - Solicitation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Air Force Targeting Center - Amendment 007 AFTARGETINGCTR Joint Base Langley-Eustis, Hampton, VA December 23, 2020
SECTION 08 71 00
DOOR HARDWARE (Revised Amendment 007) 02/16
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E283 (2004; R 2012) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.1 (2016) Butts and Hinges
ANSI/BHMA A156.10 (2011) Power Operated Pedestrian Doors
ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000
ANSI/BHMA A156.14 (2013) Sliding and Folding Door Hardware
ANSI/BHMA A156.15 (2015) Release Devices Closer Holder, Electromagnetic and Electromechanical
ANSI/BHMA A156.16 (2013) Auxiliary Hardware
ANSI/BHMA A156.17 (2014) Self Closing Hinges & Pivots
ANSI/BHMA A156.18 (2016) Materials and Finishes
ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power Operated Doors
ANSI/BHMA A156.2 (2017) Bored and Preassembled Locks and Latches
ANSI/BHMA A156.21 (2014) Thresholds
ANSI/BHMA A156.22 (2012) Door Gasketing and Edge Seal Systems
ANSI/BHMA A156.23 (2010) Electromagnetic Locks
ANSI/BHMA A156.24 (2012) Delayed Egress Locking Systems
ANSI/BHMA A156.25 (2013) Electrified Locking Devices
ANSI/BHMA A156.26 (2012) Continuous Hinges
SECTION 08 71 00 Page 1
UNCLASSIFIED\\FOUO
ANSI/BHMA A156.29 (2012) Exit Locks, Exit Alarms, Alarms for Exit Devices
ANSI/BHMA A156.3 (2014) Exit Devices
ANSI/BHMA A156.30 (2014) High Security Cylinders
ANSI/BHMA A156.36 (2010) Auxiliary Locks
ANSI/BHMA A156.4 (2013) Door Controls - Closers
ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks
ANSI/BHMA A156.6 (2015) Architectural Door Trim
ANSI/BHMA A156.7 (2016) Template Hinge Dimensions
ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2015; ERTA 2016) Life Safety Code
NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies
NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;
TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;
TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;
TIA 17-11; TIA 17-12; TIA 17-13; TIA
17-14; TIA 17-15; TIA 17-16; TIA 17-17)
National Electrical Code
NFPA 72 (2016; Errata 1 2018) National Fire Alarm and Signaling Code
NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL Bld Mat Dir (updated continuously online) Building Materials Directory
SECTION 08 71 00 Page 2
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00.00 50
SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Manufacturer's Detail Drawings; G , AE
Verification of Existing Conditions; G , AE
Hardware Schedule; G , AE
Keying System; G , AE
SD-03 Product Data
Hardware Items; G , AE
SD-08 Manufacturer's Instructions
Installation
SD-10 Operation and Maintenance Data
Hardware Schedule Items, Data Package 1; G , AE
SD-11 Closeout Submittals
Key Bitting
1.3 SHOP DRAWINGS
Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base shop drawings on verified field measurements and include verification of existing conditions.
1.4 PRODUCT DATA
Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.
1.5 HARDWARE SCHEDULE
Prepare and submit hardware schedule in the following form:
SECTION 08 71 00 Page 3
Hardware Item
Quantity Size Reference Publi-cation Type No.
Finish Mfr Name and Catalog No.
Key Control Symbols
UL
Mark (If fire-rated and listed)
BHMA
Finish Desig-nation
In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:
a. Complete listing of all keys (e.g. AA1 and AA2).
b. Complete listing of all key cuts (AA1-123456, AA2-123458).
c. Tabulation showing which key fits which door.
d. Copy of floor plan showing doors and door numbers.
e. Listing of 20 percent more key cuts than are presently required in each master system.
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, pivots, and closers of one lock, hinge, pivot, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.7.2 Key Shop Drawings Coordination Meeting
Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.
1.8 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.
1.9 SUSTAINABLE DESIGN REQUIREMENTS
1.9.1 Final Sustainability eNotebook Submittal
Refer to Section 01 33 29 SUSTAINABILITY REPORTING for federal sustainability product and documentation requirements.
SECTION 08 71 00 Page 4
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.
2.3 HARDWARE ITEMS
Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SAFETY AND SECURITY. Coordinate door hardware with scheduled door Sound Transmission Class (STC) and/or Outdoor-Indoor Transmission Class (OITC) ratings.
2.3.1 Hinges
Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.
2.3.2 Continuous Hinges
Where continuous hinges are required, provide in accordance with
ANSI/BHMA A156.26 .
2.3.3 Pivots
Provide in accordance with ANSI/BHMA A156.17 .
2.3.4 Locks and Latches
2.3.4.1 Mortise Locks and Latches
Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.
2.3.4.2 Bored Locks and Latches
Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.
SECTION 08 71 00 Page 5
2.3.4.3 Auxiliary Locks
Provide in accordance with ANSI/BHMA A156.36 , Grade 1.
2.3.5 Exit Devices
Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons not less than 7 by 2-1/4 inch.
2.3.6 Exit Locks With Alarm
Provide in accordance with ANSI/BHMA A156.3 and ANSI/BHMA A156.29 , Type E0431 (with full width horizontal actuating bar) for single doors; Type E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified. Provide door alarms integrated with the fire alarm system in accordance with NFPA 72 .
2.3.7 Cylinders and Cores
Provide cylinders for new locks, including locks provided under other sections of this specification. Provide fully compatible cylinders of Grade 1 products from products of one manufacturer with interchangeable cores that are removable by a special control key. Stamp all cores with a key control symbol in a concealed place on the core. Factory set the cores with seven pin tumblers using the A2 system and WB keyway. Submit a core code sheet with the cores. Provide master keyed cores in one system for this project. Provide construction interchangeable cores.
2.3.7.1 High Security Cylinders
Provide in accordance with ANSI/BHMA A156.30 , security level A for all high security cylinder components.
2.3.8 Push Button Mechanisms
Provide in accordance with ANSI/BHMA A156.5 , Grade 1.
2.3.9 Electrified Hardware
Comply with the requirements of NFPA 70 for wiring of electrified hardware.
2.3.9.1 Electric Strikes and Frame Mounted Actuators
2.3.9.1.1 Solenoid
Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.
SECTION 08 71 00 Page 6
2.3.9.1.2 Signal Switches
Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.
Signal switches must report a forced entry to the system.
2.3.9.1.3 Coordination
Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.
2.3.9.1.4 Mounting Method
Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.
2.3.9.2 Electrified Mortise Locks
Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that remain secure during power failure.
Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC STRIKES AND FRAME MOUNTED ACTUATORS.
2.3.9.2.1 Power Transfer Hinges
Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.
2.3.9.3 Card Readers and Keypad Access Control Hardware
Provide in accordance with ANSI/BHMA A156.5 and ANSI/BHMA A156.25 , Grade 1 components. Provide devices that are tamper alarmed, tamper and vandal resistant, solid state, and do not contain electronics which could compromise the access control subsystem should the subsystem be attacked.
Provide surface, semi-flush, pedestal, or weatherproof mountable devices as specified for each individual location. Provide proximity type card readers capable of reading magnetic stripe, high coercivity magnetic stripe, Keypad, Smart Card type access control cards. Provide keypads that contain an integral 12-digit tactile keyboard with digits arranged in numerical order. Provide keypads that are a standalone device or integrated into the card reader as indicated. Coordinate access control hardware with corresponding devices and systems specified in Division 28
ELECTRONIC SAFETY AND SECURITY.
2.3.9.4 Power Operated Pedestrian Door Hardware
Provide in accordance with ANSI/BHMA A156.10 , Grade 1.
2.3.9.5 Release Devices
In accordance with ANSI/BHMA A156.15 , Grade 1.
SECTION 08 71 00 Page 7
2.3.9.5.1 Closer Holders
Provide door mounted closer holder devices connected by integral releasing to smoke detecting devices.
2.3.9.5.2 Release Devices
Provide wall mounted Electromagnetic release devices connected to smoke detecting devices. Provide manual release pushbutton in the immediate vicinity of door. Coordinate location with A/E.
2.3.9.6 Power Assist and Low Energy Power Operated Doors
Provide in accordance with ANSI/BHMA A156.19 , Grade 1.
2.3.9.7 Electromagnetic Locks
Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local controller.
2.3.9.7.1 Armature
Provide electromagnetic locks with internal circuitry to eliminate residual magnetism and inductive kickback. Provide atuating armature that operates on 12 or 24 Volts dc and cannot dissipate more than 12 Watts.
Holding current must be less than 500 milliamperes. Actuating armature must take less than 300 milliseconds to change the status of the lock from fully secure to fully open or fully open to fully secure.
2.3.9.7.2 Mounting Method
Provide electromagnetic lock suitable for use with single and double door with mortise or rim type hardware and compatible with right or left hand mounting.
2.3.9.8 Delayed Egress Locking System
Provide in accordance with ANSI/BHMA A156.24 , Grade 1.
2.3.10 Keying System
Provide a grand master keying system. Provide construction interchangeable cores.
Provide sub-master keying system for the building, and keyed to the existing removable core master and grand master keying systems. The Contracting Officer will provide keying information. Key equipment spaces and mechanical rooms separately from the building systems, and key alike to the existing master and grand master systems for these doors.
Provide cylinders of Grade 1 products from one manufacturer. Notify the
SECTION 08 71 00 Page 8
Contracting Officer 90 days prior to the required delivery of the cylinders. Provide temporary cores and keys for the Contractor's use during construction, and for testing of locksets. Refer to Section 01 11 00 Special Conditions for additional information related to Keying.
2.3.11 Lock Trim
Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.
2.3.11.1 Knobs and Roses
Provide in accordance with ANSI/BHMA A156.2 and ANSI/BHMA A156.13 for knobs, roses, and escutcheons. For unreinforced knobs, roses, and escutcheons, provide a 0.050 inch thickness. For reinforced knobs, roses, and escutcheons, provide an outer shell thickness of 0.035 inch and a combined total thickness of 0.070 inch, except at knob shanks. Provide knob shanks 0.060 inch thick.
2.3.11.2 Lever Handles
Provide lever handles. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
2.3.11.3 Texture
Provide knurled or abrasive coated knobs or lever handles for doors which are accessible to blind persons and which lead to dangerous areas.
2.3.12 Keys
Furnish one file key, one duplicate key, and one working key for each key change and for each master and grand master keying system. Furnish one additional working key for each lock of each keyed-alike group. Provide construction master keys control keys for removable cores. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.
2.3.13 Door Bolts
Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.
2.3.14 Closers
Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, pivots, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.
SECTION 08 71 00 Page 9
2.3.14.1 Identification Marking
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.
2.3.15 Overhead Holders
Provide in accordance with ANSI/BHMA A156.8 .
2.3.16 Door Protection Plates
Provide in accordance with ANSI/BHMA A156.6 .
2.3.16.1 Sizes of Kick Plates
2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 8 inch kick plates for flush doors as indicated.
2.3.17 Door Stops and Silencers
Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.
Provide three silencers for each single door, two for each pair.
2.3.18 Thresholds
Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise. Provide thresholds as required for ATFP and STC performance.
2.3.19 Weatherstripping Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.
Provide a set to include head and jamb seals and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed 0.5 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:
2.3.19.1 Extruded Aluminum Retainers
Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.
2.3.19.2 Interlocking Type
Zinc or bronze not less than 0.018 inch thick.
2.3.19.3 Spring Tension Type
Spring bronze or stainless steel not less than 0.008 inch thick.
2.3.20 Soundproofing Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide adjustable
SECTION 08 71 00 Page 10 doorstops at heads,jambs and automatic door bottoms in accordance with the hardware set, of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed cell sponge gasket. Provide door bottoms with adjustable operating rod and silicone rubber or closed cell sponge neoprene gasket. Provide doorstops that are mitered at corners. Provide type and function designation where specified in paragraph HARDWARE SETS.
2.3.21 Rain Drips
Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, clear anodized factory painted finish. Provide the manufacturer's full range of color choices to the Contracting Officer for color selection Provide rain drips with a 4 inch overlap on each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection. Set drips in sealant and fasten with stainless steel screws.
2.3.21.1 Door Rain Drips
Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.
2.3.21.2 Overhead Rain Drips
Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.
2.3.22 Auxiliary Hardware (Other than locks)
Provide in accordance with ANSI/BHMA A156.16 , Grade 1.
2.3.23 Sliding and Folding Door Hardware
Provide in accordance with ANSI/BHMA A156.14 , Grade 1. Finishes to match other hardware specified herein.
2.3.24 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.
2.4 FASTENERS
Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.
2.5 FINISHES
Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel
SECTION 08 71 00 Page 11 with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish. Match exposed parts of concealed closers to lock and door trim.
Match hardware finish for aluminum doors to the doors.
2.6 KEY CABINET AND CONTROL SYSTEM
Provide in accordance with ANSI/BHMA A156.5 . Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.
PART 3 EXECUTION
3.1 INSTALLATION
Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.
Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.
3.1.1 Weatherstripping Installation
Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.
3.1.1.1 Stop Applied Weatherstripping
Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.
3.1.1.2 Interlocking Type Weatherstripping
Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.
3.1.1.3 Spring Tension Type Weatherstripping
Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.
3.1.2 Soundproofing Installation
Provide as specified for stop applied weatherstripping.
3.1.3 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws.
3.2 FIRE DOORS AND EXIT DOORS
Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door
SECTION 08 71 00 Page 12 assemblies.
3.3 HARDWARE LOCATIONS
Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.
a. Kick Plates: Push side of single-acting doors. Both sides of double-acting doors.
b. Mop Plates: Bottom flush with bottom of door.
3.4 KEY CABINET AND CONTROL SYSTEM
Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.5 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.
3.6 DOOR HARDWARE SETS
The door hardware sets represent the design intent and direction of the owner and architect. They are a guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.
The supplier is responsible for handing and sizing all products and providing the correct option for the appropriate door type and material where more than one is presented in the hardware sets. Quantities listed are for each pair of doors, or for each single door.
Manufacturer's Abbreviations:
MK - McKinney MR - Markar PE - Pemko SU - Securitron RO - Rockwood SA - Sargent KA - Kaba Ilco GS - ASSA ABLOY Glass Solutions SG - Sargent & Greenleaf Inc BE - Best Access Systems
SECTION 08 71 00 Page 13
RF - Rixson NO - Norton
Set: 1 Doors: X100A
2 Continuous Hinge CFMSLF-HD1 x PT PE 2 Electric Power Transfer EL-CEPT SU 1 cvr Exit Device 43 55 56 AD8610 US32D SA 1 cvr Exit Device 43 53 55 56 72 AD8610 106 x 862 US32D SA 1 Core 1C-7 626 BE 2 Pull RM7902-12 US32D RO 2 Overhead Stop 1-SERIES 630 RF 2 Auto Operator 6300 SERIES x 120V 689 NO 1 Switch Post 500 NO 1 Door Switch 501 NO 1 Door Switch 503 NO 1 Threshold 252x3AFG PE 1 Weatherseal BY ALUMINUM DOOR SUPPLIER 2 Sweep 345CV PE 2 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 2 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-24 YA 2 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: During OPEN hours (programmed through access control system) latches of exit devices are electronically held retracted, exterior door switch is enabled and opening functions as manual push/pull or assisted entry/egress by pressing either door switch to activate automatic operators. During CLOSED hours (programmed through access control system) latches of exit devices are electronically secured and exterior door switch is disabled. Entry by key in cylinder at RHR leaf.
Manual egress at all times by pressing rail of either exit device and exiting. Pressing rail of either exit device shunts door contacts for authorized egress.
Door contacts monitor the position of the doors and report this status to the security system.
Set: 2 Doors: 100A.2
2 Continuous Hinge CFMSLF-HD1 x PT PE 2 Electric Power Transfer EL-CEPT SU 1 cvr Exit Device 43 55 56 AD8610 US32D SA 1 cvr Exit Device 43 53 55 56 72 AD8610 106 x 862 US32D SA 1 Core 1C-7 626 BE 2 Pull RM7902-12 US32D RO 2 Overhead Stop 1-SERIES 630 RF 2 Auto Operator 6300 SERIES x 120V 689 NO 2 Door Switch 503 NO 1 Weatherseal BY ALUMINUM DOOR SUPPLIER 2 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 2 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-24 YA 2 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
SECTION 08 71 00 Page 14
Operational Description: During OPEN hours (programmed through access control system) latches of exit devices are electronically held retracted, vestibule door switch is enabled and opening functions as manual push/pull or assisted entry/egress by pressing either door switch to activate automatic operators. During CLOSED hours (programmed through access control system) latches of exit devices are electronically secured and exterior door switch is disabled. Entry by key in cylinder at RHR leaf.
Manual egress at all times by pressing rail of either exit device and exiting. Pressing rail of either exit device shunts door contacts for authorized egress.
Door contacts monitor the position of the doors and report this status to the security system.
Set: 3 Doors: X114, XS101, XS102, XS103, XS105
1 Continuous Hinge FM300 630 MR 1 Security Dev (EXIT ONLY) LKM7002 (FF-L-2890) 630 KA 1 Closer UNI7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Threshold 252x3AFG PE 1 Gasketing 312CR PE 1 Sweep 345CV PE 1 Door Contact BY SECURITY CONTRACTOR
Door contact monitors the position of the door and reports this status to the security system.
Set: 4 Doors: NOT USED
Set: 5 Doors: X124.2
6 Hinge BY STC ASSEMBLY SUPPLIER US26D 1 Keyed Rem Mullion L980 PC SA 2 Security Dev (EXIT ONLY) LKM7002 (FF-L-2890) 630 KA 1 Rim Cylinder 72 41 US32D SA 1 Core 1C-7 626 BE 2 Closer UNI7500 689 NO 2 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Threshold BY STC ASSEMBLY SUPPLIER 1 Gasketing BY STC ASSEMBLY SUPPLIER 2 Sweep BY STC ASSEMBLY SUPPLIER 1 Split Astragal BY STC ASSEMBLY SUPPLIER 2 Door Contact BY SECURITY CONTRACTOR
Door contacts monitor the position of the doors and report this status to the security system.
SECTION 08 71 00 Page 15
Set: 6 Doors: NOT USED
Set: 7 Doors: X126, X127.1, X128
2 Continuous Hinge FM300 630 MR 1 Keyed Rem Mullion L980 PC SA 1 Exit Device 43 8810 US32D SA 1 Exit Device 43 72 8804 ETP US32D SA 1 Mortise Cylinder 72 34 US32D SA 2 Core 1C-7 626 BE 2 Closer UNI7500 689 NO 2 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Threshold 252x3AFG PE 2 Sweep 345CV PE 1 Weatherseal 2891APK PE 1 Split Astragal 305CN PE 2 Door Contact BY SECURITY CONTRACTOR
Door contacts monitor the position of the doors and report this status to the security system.
Set: 8 Doors: X129.2
1 Hardware BY OVERHEAD DOOR SUPPLIER
Set: 9 Doors: NOT USED
Set: 10 Doors: NOT USED
Set: 11 Doors: X129.3
1 Continuous Hinge FM300 630 MR 1 Keypad Lock DL2700 US26D KA 1 Core 1C-7 626 BE 1 Closer UNIJ7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Threshold 252x3AFG PE 1 Sweep 345CV PE 1 Weatherseal 2891APK PE 1 Door Contact BY SECURITY CONTRACTOR
Operational Description: Door is normally closed and locked. Entering a valid code into keypad on lockset will momentarily unlock lever, allowing
SECTION 08 71 00 Page 16 entry. Entry also by key in cylinder. Manual egress at all times by operating inside lever and exiting.
Door contact monitors the posiition of the door and report this status to the security system.
Set: 12 Doors: 100B
3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Privacy w/ Indicator 49 8266 LNP US26D SA 1 Closer CPS7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO
Set: 13 Doors: 119.2, 220
3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Electric Power Transfer EL-CEPT SU 1 Access Control Mort Lock 72 M1-82271-12V-BIPS LNP US26D SA 1 Core 1C-7 626 BE 1 Closer PR7500 689 NO 1 Wall Stop 409 US32D RO 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-12 SU 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed and locked. Presenting a valid card to card reader on lockset will momentarily unlock outside lever, allowing entry. Entry also by key in cylinder. Egress at all times by operating inside lever and exiting. Operating inside lever will shunt door contact for authorized egress (REX). Door contact monitors the position of the door and reports this status to the security system.
Set: 14 Doors: 101
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Electric Power Transfer EL-CEPT SU 1 Access Control Mort Lock 72 M1-82271-12V-BIPS LNP US26D SA 1 Core 1C-7 626 BE 1 Closer R7500 689 NO 1 Wall Stop 409 US32D RO 1 Acoustic Seal Set PEMKOSTCSET-1A BL PE 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-12 SU 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed and locked. Presenting a valid card to card reader on lockset will momentarily unlock outside
SECTION 08 71 00 Page 17 lever, allowing entry. Entry also by key in cylinder. Egress at all times by operating inside lever and exiting. Operating inside lever will shunt door contact for authorized egress (REX). Door contact monitors the position of the door and reports this status to the security system.
Set: 15 Doors: 101A, 101B, 102A, 102B, 102C, 102E, 102F, 102G, 107B, 107C, 107D, 107F, 107G, 107H, 107J, 107K, 107M, 107N, 107P, 111A, 111B, 111C, 111D, 111E, 111G, 111H, 120B, 120C, 122A, 122B, 122C, 203D, 203E, 205A, 205B, 205C, 206A, 206B, 206C, 207A, 207B, 215B, 215C, 215D, 215E, 221A, 221B, 221C, 223B, 223C, 224A, 224B, 224C
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 72 8237 LNP US26D SA 1 Core 1C-7 626 BE 1 Wall Stop 409 US32D RO
Set: 16 Doors: 202.2
1 Surface Bolt 580-12 US26D RO 1 Passage Set 8215 LNP US26D SA 1 Closer 7500 689 NO
HINGES, SEALS, DOOR BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.
Set: 17 Doors: 102D, 111F, 201.1, 202.1, 203C
1 Electric Power Transfer EL-SEPT SU 1 Access Control Mort Lock 72 M1-82271-12V-BIPS LNP US26D SA 1 Core 1C-7 626 BE 1 Closer 7500 689 NO 1 Wall Stop 409 US32D RO 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-12 SU 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed and locked. Presenting a valid card to card reader on lockset will momentarily unlock outside lever, allowing entry. Entry also by key in cylinder. Egress at all times by operating inside lever and exiting. Operating inside lever will shunt door contact for authorized egress (REX). Door contact monitors the position of the door and reports this status to the security system.
HINGES, SEALS, DOOR BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.
Set: 18 Doors: NOT USED
SECTION 08 71 00 Page 18
Set: 19 Doors: 102J, 114.2, 122.2
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Office Lock 72 8205 LNP US26D SA 1 Core 1C-7 626 BE 1 Closer PR7500 689 NO 1 Wall Stop 409 US32D RO
Set: 20 Doors: 103, 113, 121, 204, 216, 222
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Electric Power Transfer EL-CEPT SU 1 Access Control Exit Dev 12 43 72 MI-8876-12V-BIPS ETP US32D SA 1 Core 1C-7 626 BE 1 Closer CPS7500 689 NO 1 Gasketing S88BL PE 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-12 SU 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed and lever of exit device trim is electronically locked. Presenting a valid card to card reader on exit device trim will momentarily unlock outside lever, allowing entry.
Entry also by key in cylinder. Egress at all times by pressing rail of exit device and exiting. Pressing rail of exit device will shunt door contact for authorized egress (REX).
Door contact monitors the position of the door and reports this status to the security system.
Set: 21 Doors: 104.1, 104.2, 214.1, 214.2
1 Electric Power Transfer EL-SEPT SU 1 Electrified Mortise Lock 72 NAC-82271-24v LNP US26D SA 1 Core 1C-7 626 BE 1 Closer 7500 689 NO 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply EPS-05 SU 1 Card Reader/Key Pad BY SECURITY CONTRACTOR 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed and locked. Presenting a valid card/code to card reader/key pad will momentarily unlock outside lever of lockset, allowing entry. Entry also by key in cylinder. Manual egress by operating inside lever and exiting. Operating inside lever will shunt door contact for authorized egress.
Door contact monitors the position of the door and report this status to
SECTION 08 71 00 Page 19 the security system.
HINGES, SEALS, DOOR BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.
Set: 22 Doors: 107.1, 107.2, 114.1, 115, 120
1 Exit Device PDU8000-3 SFIC US32D GS 1 Core 1C-7 626 BE 1 Concealed Closer OHC-609-90HO GS
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
Set: 22 Doors: 107.1, 107.2, 114.1, 115, 120
1 Exit Device PDU8000-3 SFIC or by US32D GS Demountable Manuf.
1 Core 1C-7 626 BE 1 Concealed Closer OHC-609-90HO or by GS Demountable Manuf.
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
Set: 23 Doors: 107E, 120D, 211, 217.1, 217.2, 218
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Set 8215 LNP US26D SA 1 Wall Stop 409 US32D RO
Set: 24 Doors: 108, 109, 208, 209, 232, 233
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Push Plate 70C-RKW (4 x 16) US32D RO 1 Pull RM301 US32D RO 1 Closer R7500 689 NO 1 Wall Stop 409 US32D RO
Set: 25 Doors: NOT USED
Set: 26 Doors: 114.3, 114.4
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Set 8215 LNP US26D SA 1 Closer CPS7500 689 NO
SECTION 08 71 00 Page 20
Set: 27 Doors: NOT USED
Set: 28 Doors: 119.1
8 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 2 Electric Power Transfer EL-CEPT SU 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Access Control Mort Lock 72 M1-82271-12V-BIPS LNP US26D SA 1 Core 1C-7 626 BE 1 Overhead Stop 1-SERIES 630 RF 1 Closer CPS7500 689 NO 2 Kick Plate K1050 - 10" x 1" LDW x BEV x CSK US32D RO 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-12 SU 2 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Doors are normally closed and locked. Presenting a valid card to card reader on lockset at RH/RHR leaf will momentarily unlock outside lever, allowing entry. Entry also by key in cylinder at RH/RHR leaf. Egress at all times by operating inside lever and exiting.
Operating inside lever will shunt door contacts for authorized egress (REX). Door contacts monitor the position of the doors and report this status to the security system.
Set: 29 Doors: NOT USED
Set: 30 Doors: 123.1
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Set 8215 LNP US26D SA 1 Door Stop & Holder 490 US26D RO
Set: 31 Doors: 124.1, 124.2, 124.3
1 Exit Device 43 72 8813 ETP US32D SA 1 Core 1C-7 626 BE 1 Closer 7500 689 NO 1 Door Stop & Holder 490 US26D RO
HINGES, SEALS, DOOR BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.
SECTION 08 71 00 Page 21
Set: 32 Doors: 129.1
1 Continuous Hinge FM300 630 MR 1 Continuous Hinge FM300 CTP 630 MR 1 Electric Power Transfer CEPT-10 SU 2 Flush Bolt 555 US26D RO 2 Magnetic Lock M680EBD 628 SU 1 Security Device LKM7006 (FF-L-2890) 630 KA 1 Combination Lock CDX-10 KA 1 Mortise Cylinder 72 34 US32D SA 1 Core 1C-7 626 BE 1 Closer R7500 689 NO 2 Kick Plate K1050 - 10" x 1" LDW x BEV x CSK US32D RO 1 Threshold BY STC ASSEMBLY SUPPLIER 1 Gasketing BY STC ASSEMBLY SUPPLIER 2 Sweep BY STC ASSEMBLY SUPPLIER 1 Split Astragal BY STC ASSEMBLY SUPPLIER 1 Power Supply BPS-24 YA 2 Card Reader BY SECURITY CONTRACTOR 2 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed, locked and secured by magnetic lock. Presenting a valid card to card reader will momentarily unlock outside lever of lockset, release magnetic lock and shunt door contact allowing entry. Presenting a valid card to the inside card reader will momentarily release magnetic lock and shunt door contact allowing egress by operating inside lever and exiting. Upon activation of fire alarm system or signal from fire command center, power to the magnetic lock is interrupted allowing free egress by operating inside lever and exiting. Entry by key in cylinder.
Door contact monitors the position of the door and report this status to the security system.
Set: 33 Doors: 130.1
1 Continuous Hinge FM300 CTP 630 MR 1 Electric Power Transfer CEPT-10 SU 1 Security Device LKM7006 (FF-L-2890) 630 KA 1 Mortise Cylinder 72 34 US32D SA 1 Core 1C-7 626 BE 1 Closer CPS7500 689 NO 1 Threshold BY STC ASSEMBLY SUPPLIER 1 Gasketing BY STC ASSEMBLY SUPPLIER 1 Sweep BY STC ASSEMBLY SUPPLIER 1 Power Supply BPS-24 YA 1 Card Reader/Key Pad BY SECURITY CONTRACTOR 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed and locked. Presenting a valid card/code to card reader/key pad will momentarily unlock outside lever of lockset and shunt door contact allowing entry. Entry also by key in cylinder. Manual egress at all times by operating inside lever and
SECTION 08 71 00 Page 22 exiting. Operating inside lever will shunt door contact for authorized egress.
Door contact monitors the position of the door and report this status to the security system.
Set: 34 Doors: 130.2
1 Continuous Hinge FM300 630 MR 1 Magnetic Lock M680EBD 628 SU 1 Security Dev (EXIT ONLY) LKM7002 (FF-L-2890) 630 KA 1 Closer CPS7500 689 NO 1 Power Supply BPS-24 YA 1 Card Reader BY SECURITY CONTRACTOR 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed, latched and secured with magnetic lock; EXIT ONLY. Presenting a valid card to the card reader will momentarily release magnetic lock and shunt door contact for authorized egress. Upon activation of fire alarm system, power to the magnetic lock is interrupted allowing free and immediate egress by operating exit device and exiting.
Set: 35 Doors: 132
3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Exit Device 12 43 72 8804 ETP US32D SA 1 Core 1C-7 626 BE 1 Closer CPS7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Gasketing S88BL PE
Set: 36 Doors: S101.1
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Electric Power Transfer EL-CEPT SU 1 Exit Device 12 43 55 72 8876-12v ETP US32D SA 1 Core 1C-7 626 BE 1 Closer R7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Wall Stop 409 US32D RO 1 Gasketing S88BL PE 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-24 YA 1 Card Reader/Key Pad BY SECURITY CONTRACTOR 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Door is normally closed and locked. Presenting a
SECTION 08 71 00 Page 23 valid card/code to the card reader/key pad will momentarily unlock lever of exit device trim, allowing entry. Entry also by key in cylinder. Manual egress at all times by pressing rail of exit device and exiting. Pressing rail of exit device will shunt door contact for authorized egress. Door contact monitors the position of the door and reports this stauts to the security system.
Set: 37 Doors: NOT USED
Set: 38 Doors: 203.1, 223.2
2 Exit Device PDU8000-3 SFIC US32D GS 2 Core 1C-7 626 BE 2 Concealed Closer OHC-609-90HO GS 2 Door Stop 442 US26D RO
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
Set: 38 Doors: 203.1, 223.2
2 Exit Device PDU8000-3 SFIC or by US32D GS Demountable Manuf.
2 Core 1C-7 626 BE 2 Concealed Closer OHC-609-90HO or by GS Demountable Manuf.
2 Door Stop 442 US26D RO
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
Set: 39 Doors: NOT USED
Set: 40 Doors: 207
2 Push Bar RM412 x T13HD US32D RO 2 Pull RM3301-DR HT x T13HD US32D RO 2 Concealed Closer OHC-609-90NHO GS 2 Door Stop 442 US26D RO
Operational Description: Door is normally closed and secured with magnetic lock. Presenting a valid card to the card reader will momentarily release magnetic lock allowing entry. Entering read range of motion sensor or pressing push button will momentarily release magnetic lock and shunt door contact for authorized egress. Upon activation of fire alarms system or signal from fire command center, power to the magnetic lock is interrupted allowing free and immediate egress.
Door contact monitors the position of the door and reports this status to the security system.
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
SECTION 08 71 00 Page 24
Set: 41 Doors: 102, 111.1, 122.1, 205, 206, 221, 224
2 Magnetic Lock M680EBD 628 SU 2 Push Bar RM412 x T13HD US32D RO 2 Pull RM3301-DR HT x T13HD US32D RO 2 Concealed Closer OHC-609-90NHO GS 2 Door Stop 442 US26D RO 1 Power Supply EPS-05 SU 1 Card Reader BY SECURITY CONTRACTOR 1 Motion Sensor XMS SU 1 Push Button EEB2 SU 2 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Notes: Operational Description: Doors are normally closed and secured with magnetic locks. Presenting a valid card to the card reader will momentarily release magnetic locks allowing entry. Entering read range of motion sensor or pressing push button will momentarily release magnetic locks and shunt door contacts for authorized egress. Upon activation of fire alarms system or signal from fire command center, power to the magnetic locks is interrupted allowing free and immediate egress.
Door contacts monitor the position of the doors and report this status to the security system.
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
Set: 41 Doors: 102, 111.1, 122.1, 205, 206, 221, 224
2 Magnetic Lock M680EBD 628 SU 2 Push Bar RM412 x T13HD or by US32D RO Demountable Manuf.
2 Pull RM3301-DR HT x T13HD or by US32D RO Demountable Manuf.
2 Concealed Closer OHC-609-90NHO or by GS Demountable Manuf.
2 Door Stop 442 US26D RO 1 Power Supply EPS-05 SU 1 Card Reader BY SECURITY CONTRACTOR 1 Motion Sensor XMS SU 1 Push Button EEB2 SU 2 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Notes: Operational Description: Doors are normally closed and secured with magnetic locks. Presenting a valid card to the card reader will momentarily release magnetic locks allowing entry. Entering read range of motion sensor or pressing push button will momentarily release magnetic locks and shunt door contacts for authorized egress. Upon activation of fire alarms system or signal from fire command center, power to the magnetic locks is interrupted allowing free and immediate egress.
Door contacts monitor the position of the doors and report this status to the security system.
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
SECTION 08 71 00 Page 25
Set: 42 Doors: NOT USED
Set: 43 Doors: 116, 213
1 Cased Frame NO HARDWARE REQ'D.
Set: 44 Doors: 131
6 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Keyed Mullion 12 L980 PC SA 1 Exit Device 12 43 8810 US32D SA 1 Exit Device 12 43 72 8804 ETP US32D SA 1 Rim Cylinder 72 41 US32D SA 1 Core 1C-7 626 BE 2 Closer CPS7500 689 NO 2 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Gasketing S88BL PE 1 Mtg Edge Gasketing S772BL PE
Set: 45 Doors: S102.1, S201, S202, S203, S205
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Exit Device 12 43 72 8813 ETP US32D SA 1 Core 1C-7 626 BE 1 Closer R 7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Gasketing S88BL PE
Set: 46 Doors: 100C, 110, 117, 202B, 210, 224D, 229
3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock 72 8204 LNP US26D SA 1 Core 1C-7 626 BE 1 Closer 7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Wall Stop 409 US32D RO
Set: 47 Doors: 230
4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Electric Power Transfer EL-CEPT SU 1 Electrified Mortise Lock 72 NAC 82271-24v LNP US26D SA 1 Core IC-7 626 BE
SECTION 08 71 00 Page 26
1 Closer 7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Wall Stop 409 US32D RO 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-24 SU 1 Card Reader BY SECURITY CONTRACTOR 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT
Operational Description: Doors are normally closed and locked. Presenting a valid card to card reader on lockset at RH/RHR leaf will momentarily unlock outside lever, allowing entry. Entry also by key in cylinder at RH/RHR leaf. Egress at all times by operating inside lever and exiting.
Operating inside lever will shunt door contacts for authorized egress (REX). Door contacts monitor the position of the doors and report this status to the security system.
Set: 48 Doors: 112.1, 112.2, 225
4 Hinge BY STC ASSEMBLY SUPPLIER US26D 1 Office Lock 72 8205 LNP US26D SA 1 Core 1C-7 626 BE 1 Closer 7500 689 NO 1 Threshold BY STC ASSEMBLY SUPPLIER 1 Gasketing BY STC ASSEMBLY SUPPLIER 1 Sweep BY STC ASSEMBLY SUPPLIER
Set: 49 Doors: 215.1, 215.2, 223.1
1 Pull RM3301-DR HT x T13HD US32D RO 1 Concealed Closer OHC-609-90HO GS
NOTE: Doors can be held open when required by hold open function in closer.
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
Set: 49 Doors: 215.1, 215.2, 223.1
1 Pull RM3301-DR HT x T13HD or by US32D RO Demountable Manuf.
1 Concealed Closer OHC-609-90HO or by GS Demountable Manuf.
NOTE: Doors can be held open when required by hold open function in closer.
BALANCE OF HARDWARE BY GLASS DOOR SUPPLIER.
Set: 50 Doors: 215A, 223A
8 Hinge TA2714 4-1/2" x 4-1/2" US26D MK
SECTION 08 71 00 Page 27
2 Flush Bolt 557 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Passage Set 8215 LNP US26D SA
Set: 51 Doors: 127
3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Exit Device 12 43 72 8804 ETP US32D SA 1 Core 1C-7 626 BE 1 Closer CPS7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Gasketing S88BL PE 1 Door Contact BY SECURITY CONTRACTOR
Door contact…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .