Vol.1B_Revised_Sheet A-601 - DOOR SCHEDULE - LEVEL 1.pdf

PDF 235 KB Posted

Attached to
Air Force Targeting Center, Langley AFB - Solicitation Federal contract opportunity
Solicitation number
W9123621R2005
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document package includes a door schedule and specifications for a federal construction project, as well as the related solicitation.

The door schedule provides details on over 150 doors for levels one and two of the Air Force Targeting Center facility at Langley Air Force Base, including door dimensions, materials, fire ratings, hardware requirements, and notes. The solicitation seeks construction services to build the new Targeting Center in accordance with military standards, including site work, utilities, and supporting facilities. The scope includes conventional design and building methods, with local materials where cost-effective. The facility must meet antiterrorism criteria and support the mission of the 25th Air Force wing for command and control of targeting and threat analysis. The solicitation number is W9123621R2005 and was issued by the Army Corps of Engineers Norfolk District.

The document package provides relevant specifications and requirements for the federal construction project at Langley Air Force Base.

View the file

Other files for this federal contract opportunity

Other files attached to Air Force Targeting Center, Langley AFB - Solicitation, newest first.
File Type Posted
W9123621R2005 Amendment 0008.pdf PDF
Vol.1B_Revised_Sheet A-313 - EXTERIOR WALL SECTIONS.pdf PDF
Specs_V2_Revised_10 22 19.pdf PDF
Specs_V1_Revised_02 60 00.pdf PDF
Specs_V2_Revised_08 71 00.pdf PDF
Specs_V1_Revsied_00 00 00_TOC.pdf PDF
Vol.1A_Revised_Sheet CD-101 DEMOLITION PLAN.pdf PDF
Specs_V1_Revised_Appendix_B_ESS.pdf PDF
Vol.1B_Revised_Sheet IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C.pdf PDF
Vol.1A_Revised_Sheet CG-111 EROSION & SEDIMENT CONTORL DETAIL SHEET.pdf PDF
Langley Furniture Qty.pdf PDF
Vol.1B_Revised_Sheet A-602 - DOOR SCHEDULE - LEVEL 2.pdf PDF
Specs_V1_Revised_00 00 00_TOC.pdf PDF
Specs_V2_Revised_08 81 00.pdf PDF
Vol.1B_Revised_Sheet I-001 INTERIOR NOTES AN FINISH LEGEND .pdf PDF
Vol.1B_Revised_Sheet A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM.pdf PDF
Specs_V3_Revised_22 00 00.pdf PDF
W9123621R2005 0006.pdf PDF
W9123621R2005 0005.pdf PDF
W9123621R2005 0004.pdf PDF
FINAL_LAFB_TCF_Norfolk_District_USACE_Geotechnical_Report.pdf PDF
W9123621R20050003.pdf PDF
20201124_RTA_Specs_V4_Div_26-33_Appendix_Consolidated.pdf PDF
2020RTA_AFTC_Vol.1A.pdf PDF
2020RTA_AFTC_Vol.1B.pdf PDF
2020RTA_AFTC_Vol.2.pdf PDF
20201124_RTA_Specs_V3_Div_21-25_Consolidated.pdf PDF
20201124_RTA_Specs_V2_Div_07-14_Consolidated.pdf PDF
20201124_RTA_Specs_V1_Div_00-06_Consolidated.pdf PDF
Site Visit Roster_AF Targeting Center 21R2005.pdf PDF
W9123621R20050002.pdf PDF
A.02.01 Amendment 0001 Solicitation 21R2005_released.pdf PDF
20190411_Furniture_specification_package_Amendment_2 (1).pdf PDF
B.02.09 Att. 2 Company Specialized Experience.pdf PDF
B.02.09 Att. 7 Small Business Participation Plan.pdf PDF
20191115_AFTC_IFC_Vol.1A (Full Scale).pdf PDF
20191115_IFC_Specs_V2_Div_07-14.pdf PDF
20191115_IFC_Specs_V4_Div_26-33_Appendix.pdf PDF
20191115_IFC_Specs_V1_Div_00-06.pdf PDF
JBLE-Langley AF TCF - NTCRA ESS Construction Support (20181115) DRAFT.pdf PDF
A.02.01 Solicitation W9123621R2005_released 11.03.2020.pdf PDF
B.02.09 Att. 1 Proposal Data Sheet.pdf PDF
B.02.09 Att. 4 Telephone Interview Questionnaire (For Government Use Only).pdf PDF
B.02.09 Att. 8 CLIN Schedule.pdf PDF
20191115_IFC_Specs_V3_Div_21-25.pdf PDF
B.02.09 Att. 3 Past Performance Questionaire.pdf PDF
B.02.09 Att. 5 Letter of Commitment Sample.pdf PDF
B.02.09 Att. 6 Small Business Subcontracting Record.pdf PDF
20191115_AFTC_IFC_Vol.1B.pdf PDF
20191115_AFTC_IFC_Vol.2.pdf PDF
Show all 50

Air Force Targeting Center, Langley AFB - Solicitation has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR SCHEDULE LEGEND

AL ALUMINUM

ANOD ANODIZED

GL-# GLAZING, RE: SPEC

GP-# DECORATIVE GLAZING, RE: FINISH LEGEND

HM HOLLOW METAL

STL STEEL

STN STAINED WOOD

PT PAINT

WD WOOD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S

O F

E N

G

IN

E E

R S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

UNCLASSIFIED\\FOR OFFICIAL USE ONLY

UNCLASSIFIED\\FOR OFFICIAL USE ONLY

J E

S S

IC

A

A N

D E

R S

O N

L A

N G

L E

Y A

F B

V

IR

G

IN

IA

L A

N G

L E

Y A

IR

F

O R

C E

T A

R G

E T

IN

G

F A

C

IL

IT

Y

H D

R

IN

C

W

A S

H

IN

G T

O N

B

L V

D S

U

IT

E

A R

L

IN

G T

O N

V

A

MAIN BLDG.

A-601

D O

O R

S C

H E

D U

L E

L

E V

E L

J E

F F

R E

Y G

E T

T Y

J O

N A

T H

A N

O S

W A

L D

A P

R

IL

D R

A K

E

/2 /2

W

-2

-R -2

READY TO ADVERTISE (RTA)

DOOR AND FRAME SCHEDULE - EXTERIOR

IDENTIFICATION DIMENSIONS PANEL FRAME

FIRE

RATING

STC

RATING

HARDWARE

SET NOTES

ROOM

NO. ROOM NAME DOOR NO.

WIDTH

H

PANEL

COUNT TYPE MATERIAL FINISH TYPE MATERIAL FINISH

FRAME DETAIL

W1 W2

TOTAL

WIDTH HEAD JAMB SILL

100A VESTIBULE X100A 4' - 0" 4' - 0" 8' - 0" 8' - 0" 2 CW AL N/A CW AL N/A D1/A-564 F1/A-564 A1/A-564 0 0 1

114 363 ISRG OPS GROUP X114 3' - 0" 7' - 2" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 0 45 3 NOTE 7, EGRESS-ONLY FUNCTION IN CONTROLLED PERIMETER

124 MULTI-PURPOSE RM X124.2 3' - 0" 3' - 0" 6' - 0" 7' - 2" 2 F/F HM PT 1 HM PT C1/A-604 A1/A-604 - 0 50 5 NOTE 7, EGRESS-ONLY FUNCTION IN CONTROLLED PERIMETER

126 MECH. RM X126 3' - 0" 3' - 0" 6' - 0" 7' - 2" 2 F/F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 7 NOTE 7

127 ELEC RM X127.1 3' - 0" 3' - 0" 6' - 0" 7' - 2" 2 F/F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 7 NOTE 7

128 MAIN COMM. RM X128 3' - 0" 3' - 0" 6' - 0" 7' - 2" 2 F/F HM PT 1 HM PT C1/A-604 A1/A-604 - 0 0 7 NOTE 7

129 WAREHOUSE X129.2 8' - 0" 10' - 0" 1 OC HM PT -- HM PT D7/A-561 A7/A-561 - 0 0 8

129 WAREHOUSE X129.3 3' - 0" 7' - 2" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 0 0 11 NOTE 7

S101 STAIR #1 XS101 3' - 0" 7' - 2" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 45 3 NOTE 7, EGRESS-ONLY FUNCTION IN CONTROLLED PERIMETER

S102 STAIR #2 XS102 3' - 0" 7' - 2" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 45 3 NOTE 7, EGRESS-ONLY FUNCTION IN CONTROLLED PERIMETER

S103 STAIR #3 XS103 3' - 0" 7' - 2" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 45 3 NOTE 7, EGRESS-ONLY FUNCTION IN CONTROLLED PERIMETER

S105 STAIR #5 XS105 4' - 0" 7' - 2" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 45 3 NOTE 7

DOOR AND FRAME SCHEDULE - LEVEL 1

IDENTIFICATION DIMENSIONS PANEL FRAME

FIRE

RATING

(MINS)

STC

RATING

HARDWARE

SET NOTES

ROOM

NO. ROOM NAME DOOR NO.

WIDTH

H

PANEL

COUNT TYPE MATERIAL FINISH TYPE MATERIAL FINISH

FRAME DETAIL

W1 W2

TOTAL

WIDTH HEAD JAMB SILL

100A VESTIBULE 100A.2 4' - 0" 4' - 0" 8' - 0" 8' - 0" 2 CW AL N/A CW AL N/A D1/A-564 F1/A-564 A1/A-564

SIM

0 0 2

100B TOILET 100B 3' - 0" 7' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 0 0 12 NOTE 1

100C STORAGE 100C 3' - 0" 7' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 0 0 46 NOTE 1

101 SECURITY OFFICE 101 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 14 NOTE 2

101A WING SO 101A 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 30 15 NOTE 6

101B SSO INDOC 101B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

102 363 ISRW COMMAND GROUP 102 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 41 NOTE 6

102A WING TD 102A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

102B WING DS 102B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

102C WING CCC 102C 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

102D WING CC 102D 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 17 NOTE 2, 8

102E WING CV 102E 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15 NOTE 8

102F WING DO 102F 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

102G WING CCF 102G 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

102J COPY 102J 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 19

103 ELECT 103 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 20

104 WING CONF. ROOM 104.1 3' - 0" 8' - 0" 1 F STL STN 1 STL PT C5/A-604 A5/A-604 - 0 50 21 NOTE 8

104 WING CONF. ROOM 104.2 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 21 NOTE 2, 8

107 363 ISRW OPS GROUP 107.1 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 22 NOTE 6

107 363 ISRW OPS GROUP 107.2 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 22 NOTE 6

107B WING SC 107B 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107C WING SE 107C 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107D WING FM 107D 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107E TEAM RM 107E 3' - 0" 8' - 0" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 30 23 NOTE 6

107F WING HC 107F 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107G WING HO 107G 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107H WING XP 107H 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107J WING IG 107J 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107K WING JA 107K 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107M WING LG 107M 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107N WING CE 107N 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

107P WING MS 107P 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

108 WOMEN'S TOILET 108 3' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 0 0 24

109 MEN'S TOILET 109 3' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 0 0 24

110 J.C. 110 3' - 0" 8' - 0" 1 F WD STN 2 AL ANOD C5/A-604 A5/A-604 - 0 0 46 NOTE 2

111 363 ISRG COMMAND GROUP 111.1 3' - 0" 3' - 0" 6' - 0" 9' - 10" 2 DG/DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 41 NOTE 6

111 363 ISRG COMMAND GROUP 111A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

111B GROUP CEM 111B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

111C GROUP IGV 111C 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

111D GROUP CCF 111D 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

111E GROUP CD 111E 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

111F GROUP CC 111F 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 17 NOTE 2, 8

111G GROUP DO 111G 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

111H GROUP FM 111H 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

112 GROUP CONF. RM 112.1 3' - 0" 8' - 0" 1 F WD STN 2 AL ANOD C5/A-604 A5/A-604 - 0 50 48

112 GROUP CONF. RM 112.2 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 50 48

113 ELECT 113 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 20

114 363 ISRG OPS GROUP 114.1 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 22 NOTE 6

114 363 ISRG OPS GROUP 114.2 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 19

114 363 ISRG OPS GROUP 114.3 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 26

114 363 ISRG OPS GROUP 114.4 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 26

115 363 ING-MIPS/CIB OPEN

OFFICE

115 3' - 0" 9' - 10" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 22 NOTE 6

116 GRAPHICS RM 116 4' - 0" 8' - 0" 1 N/A N/A N/A 3 HM PT C7/A-604 A7/A-604 - 0 0 43

117 STORAGE 117 3' - 0" 8' - 0" 1 F WD GL 2 AL ANOD C5/A-604 A5/A-604 - 0 0 46 NOTE 2

119 SERVER RM 119.1 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F/F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 28 NOTE 2

119 SERVER RM 119.2 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 13 NOTE 2

120 363 ISS OPS GROUP 120 3' - 0" 8' - 0" 1 DG GL-7 N/A 1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 22

120B ISS DO 120B 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

120C ISS SR CIV 120C 3' - 0" 8' - 0" 1 F WD STN D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 15 NOTES 1, 6

120D TEAM RM 120D 3' - 0" 8' - 0" 1 DG GL-5 N/A D1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 30 23 NOTE 6

121 ELECT 121 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 20

122 363 ISS COMMAND 122.1 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 DG/DG GL-7 N/A 1 AL ANOD RE: A-603 RE: A-603 RE: A-603 0 0 41

122 363 ISS COMMAND 122.2 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 0 19

122A ISS CCF 122A 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

122B ISS CC 122B 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

122C ISS CCS 122C 3' - 0" 8' - 0" 1 F WD STN 1 AL ANOD C3/A-604 A3/A-604 - 0 30 15

123 BREAK ROOM 123.1 3' - 0" 8' - 0" 1 F WD STN 2 AL ANOD C5/A-604 A5/A-604 - 0 0 30

124 MULTI-PURPOSE RM 124.1 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 31 NOTE 8

124 MULTI-PURPOSE RM 124.2 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 31 NOTE 8

130 MAIN CORRIDOR 124.3 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 50 31 NOTE 8

127 ELEC RM 127 3' - 0" 7' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 51 NOTE 2

129 WAREHOUSE 129.1 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F/F STL PT 1 STL PT F1/A-604 E1/A-604 - 0 45 32 NOTE 2, DOOR IN CONTROLLED PERIMETER

130 MAIN CORRIDOR 130.1 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 45 33 NOTE 2, 8

130 MAIN CORRIDOR 130.2 3' - 0" 8' - 0" 1 F STL STN 1 STL PT F1/A-604 E1/A-604 - 0 45 34 NOTE 2, 8

131 UPS 131 3' - 0" 3' - 0" 6' - 0" 7' - 0" 2 F/F HM PT 1 HM PT C1/A-604 A1/A-604 - 45 0 44 NOTE 2

132 BOILER RM 132 3' - 0" 7' - 0" 1 F HM PT 1 HM PT C1/A-604 A1/A-604 - 0 0 35

S101 STAIR #1 S101.1 3' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 45 0 36

S102 STAIR #2 S102.1 3' - 0" 8' - 0" 1 F WD STN 1 HM PT C1/A-604 A1/A-604 - 45 0 45

8. WOOD VENEER ON METAL DOOR

7. BLAST-RESISTANT DOOR - RE: BLAST REPORT

6. DOOR IS PART OF DEMOUNTABLE PARTITION SYSTEM

5. DOOR POSITION SWITCH

4. NOT USED

3. 180 DEGREE SWING

2. CARD READER

1. 3/8" UNDERCUT

DOOR SCHEDULE SHEET NOTES

5. ALL EXTERIOR DOORS SHALL ACHIEVE A MINIMUM OITC OF

35 UNLESS NOTED OTHERWISE.

4. INDICATED DOORS AND FRAMES TO BE PT-1 TYP.

3. REFER TO A-604 FOR TYPICAL DOOR AND FRAME DETAILS.

2. REFER TO A-603 FOR INTERIOR DOOR AND FRAME TYPES.

1. REFER TO PROJECT SPECIFICATIONS FOR COMPLETE LIST

OF HARDWARE IN EACH GROUP.

DOOR SCHEDULE GENERAL NOTES

A m e n d m e n t

/1

/2

Sheets
A-411 - ENLARGED PLANS AND ELEVATIONS - SHOWERS AND NURSING ROOM
A-521 - DETAILS - INTERIOR - ACOUSTIC & WOOD
A-601 - DOOR SCHEDULE - LEVEL 1
A-602 - DOOR SCHEDULE - LEVEL 2
A-607 - INTERIOR STOREFRONTS - LEVEL 2
I-001 - INTERIOR NOTES AND FINISH LEGEND
IN101A - INTERIOR FINISH PLAN - FIRST FLOOR - AREA A
IN102C - INTERIOR FINISH PLAN - SECOND FLOOR - AREA C

File details come from the government source that posted it. Updated .