PD102.pdf
PDF 154 KB Posted
- Attached to
- DLA Warehouse 11 Renovation Federal contract opportunity
- Solicitation number
- W9123620B0017
About this file
This document package includes demolition plans and specifications for renovations to Building 11 at the Defense Supply Center Richmond in Richmond, Virginia, as well as information on the related federal contract opportunity. The demolition plans detail fixtures and piping to be removed in bays C, F, I, and L, including water heaters, drinking fountains, cleanouts and floor drains. The solicitation is posted as an electronic bid only under number W9123620B0017 for the DLA Warehouse 11 Renovation project. The Army Corps of Engineers Engineering District Norfolk is the contracting agency. Bids are due per the IFB details, with no phone requests accepted. Renovations involve demolition and removal work in specified areas of the building as shown on the plans.
View the file
Other files for this federal contract opportunity
Show all 50
DLA Warehouse 11 Renovation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
A
12 13 14
UNISEX
11C-2 B
11-B
UNISEX
11C-3
T R
A N
S P
O R
T A
T
IO
N P
O
IN
T
C
-1
C
B
A
31 32
BREAK ROOM F
11F-2
WOMEN'S TOILET
11F-3
MEN'S TOILET
11F-4
B
A
48 49 50
H
11-H
WOMEN'S TOILET
11I-2
MEN'S TOILET
11I-3
VALVE ROOM
11-H/I
1 T R
A N
S P
O R
T A
T
IO
N P
O
IN
T
I-
B
A
60 61 62 63
VALVE ROOM
X11-K/L
BOILER
11-L1
BREAK ROOM
11-L2
OFFICE
11-L4
ELECT CLOSET
11-L3
IN
C
S E
C a ry
P a rk w a y S u it e
C a ry
N o rt h C a ro li n a
P
.8
1.
F
.8
1.
w w w
.e n g in e e re d d e s ig n s .c o m
E N
G
IN
E E
R E
D D
E S
IG
N
S N o rt h
C a ro li n a
L ic e n s e
C -1
0' 4' 8' 16' 32'
KEY PLAN
CB DA E F G H I K L
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
T R
U E
N O
R T H
PLAN
NORTH
F
R O
N T
S T
R E
E T
N O
R F
O L K
D
IS
T R
IC
T
N O
R F
O L K
V
IR
G
IN
IA
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
(9
-7
F
A X
L
IC
E N
S E
F
-0
W -2
-B
-0
W -1
-F
-0
N A
O F
IL
E
N O
F
IL
E N
A M
E
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D R
IC
H
M O
N D
V A
PD102
D E
M O
L
IT
IO
N
E N
L A
R G
E D
P L A
N S
J C
O L L
IN
S W
O R
T H
J C
O L L
IN
S W
O R
T H
G K
E Y
G S
C O
G G
IN
S
M
A R
C H
FOR CONSTRUCTION
R E
N O
V A
T
IO
N S
T O
B U
IL
D
IN
G
D
D R
V
P R
O J E
C T
N U
M B
E R
P
.2 .0
.0
1/8" = 1'-0"PD102
1 DEMOLITION ENLARGED PLAN - BAY C
1/8" = 1'-0"PD102
2 DEMOLITION ENLARGED PLAN - BAY F
1/8" = 1'-0"PD102
3 DEMOLITION ENLARGED PLAN - BAY I
1/8" = 1'-0"PD102
4 DEMOLITION ENLARGED PLAN - BAY L
PLUMBING WORK IS LIMITED TO ONLY
BAYS "C", "F", "I", AND "L".
EXISTING FIXTURES AND ALL ASSOCIATED PIPING TO BE REMOVED.1
NOTES KEYED TO PLAN 3-PD102
EXISTING WATER HEATER AND ALL ASSOCIATED PIPING
TO BE REMOVED.
EXISTING FIXTURES AND ALL ASSCIATED PIPING TO BE
REMOVED.
NOTES KEYED TO PLAN 2-PD102
EXISTING DRINKING FOUNTAIN AND ALL ASSOCIATED PIPING
TO BE REMOVED.
NOTES KEYED TO PLAN 4-PD102
EXISTING WATER HEATER AND ALL ASSOCIATED PIPING
TO BE REMOVED.
EXISTING CLEANOUT TO BE REMOVED.
EXISTING FLOOR DRAIN TO BE REMOVED.
NOTES KEYED TO PLAN 1-PD102
A m e n d m e n t
/6 /2
| Sheets |
| PD102 - DEMOLITION ENLARGED PLANS |