A.01.13 A-115.pdf
PDF 163 KB Posted
- Attached to
- DLA Warehouse 11 Renovation Federal contract opportunity
- Solicitation number
- W9123620B0017
About this file
This document contains plans for roof renovations to Building 11 at the Defense Supply Center in Richmond, Virginia. The plans call for replacing roof decking in several areas, replacing flashing, installing new roofing membrane and insulation, and adding new gutters, downspouts, and metal ladders. Renovations will be conducted in phases, with this plan covering bays I and K in Phase 5. The work includes repairing and replacing roof elements, as well as painting fan housings.
The related federal contract opportunity is a solicitation issued by the Department of the Army Corps of Engineers Engineering District Norfolk to renovate the roof and warehouse of Building 11 at the Defense Supply Center in Richmond. Electronic bid submissions only will be accepted through the posted solicitation number by the specified due date. The renovation work includes the roof plans detailed in the architectural drawing and additional scope for the warehouse.
View the file
Other files for this federal contract opportunity
Show all 50
DLA Warehouse 11 Renovation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
I
H
G
F
E
D
C
B
A
49 50 51 52 53 54 55 56 57 58 59 60 61
A -1
A -1
20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV
NEW DOWNSPOUT BELOW, TYP.
BELOW, TYP.NEW DOWNSPOUT
NEW DOWNSPOUT , TYP.
NEW DOWNSPOUT , TYP.
A-501
12_______
A-501
9_______
NEW GUTTER
NEW GUTTER
DOWNSPOUT, TYP.
PROVIDE WALKWAY PAD UNDER
DISHARGE. WALKWAY PAD, TYP
NEW WALKWAY
T Y
P
NEW METAL LADDER
NEW METAL LADDER
REPLACE ROOF VENTILATOR FANS SALVAGED
FROM DEMOLITION ON EXISTING ROOF
OPENINGS. PROVIDE NEW FLASHING TO NEW
ROOF MEMBRANE. PAINT FAN HOUSING, TYP
GENERAL NOTES
1. REPAIR ROOF DECK PER SHEETS S-111 THROUGH S-116.
2. FLASHING TO BE REPLACED, SEE DETAIL ON SHEET A-501
3. NEW ROOF, INSULATION, FLASHING, GUTTERS AND
DOWNSPOUTS, TYPICAL.
0' 8' 16' 32' 64'
KEY PLAN
CB DA E F G H I K L
T R
U E
N O
R T H
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N O
R F
O L K
D
IS
T R
IC
T
F
R O
N T
S T
R E
E T
N O
R F
O L K
V
IR
G
IN
IA
J
O N
E S
F R
A N
K L
IN
R D
S U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
(9
-7
F
A X
L
IC
E N
S E
F
-0
F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
N
A O
F
IL
E N
O
W -2
-B
-0
W -1
-F
-0
D S
A L T
S M
A N
FOR OFFICIAL USE ONLY
FOR CONSTRUCTION
A-115
R O
O F
P L A
N
B A
Y I
K
P
H A
S E
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D R
IC
H
M O
N D
V A
R M
O R
S O
N
T S
H O
U S
E
P Z
O O
K
M
A R
C H
R E
N O
V A
T
IO
N S
T O
B U
IL
D
IN
G
D
D R
V
P R
O J E
C T
N U
M B
E R
P
.0
.0
A -1
.D
W G
1/16" = 1'-0"A-115
1 ROOF PLAN – BAY I & K - PHASE 5
A
M E
N D
M E
N T
A P
R
File details come from the government source that posted it. Updated .