This document package includes construction plans and specifications for renovations to Building 11 of the Defense Supply Center Richmond in Richmond, Virginia. The solicitation number is W9123620B0017 and is seeking bids for renovations including replacing glass panels, installing new roof membranes, repairing roof decks, and other miscellaneous construction details. The solicitation is posted electronically with bids only accepted in electronic form. The agency issuing this IFB is the Department of the Army Corps of Engineers Engineering District Norfolk. The document provides detailed drawings and specifications for the renovation work required.
View the file
Other files for this federal contract opportunity
Show all 50
DLA Warehouse 11 Renovation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GL GL
KALWALL TRANSLUCENT BACK UP PANEL
AT BAY L CLERESTORY ONLY. CLEAN
EXISTING / NEW GLASS INTERIOR SURFACE
PRIOR TO INSTALLATION OF KALWALL
EXISTING WALL
FLASHING
CLERESTORY WINDOW,
REPLACE GLASS PANEL
IN KIND
BLOCKING AS REQUIRED
KALWALL TRANSLUCENT BACK UP
PANEL AT BAY L CLERESTORY
ONLY. CLEAN EXISTING / NEW
GLASS INTERIOR SURFACE PRIOR
TO INSTALLATION OF KALWALL
EXISTING WALL
SILL FLASHING
CLERESTORY WINDOW,
REPLACE GLASS PANEL IN
KIND
BLOCKING AS REQUIRED
NEW MEMBRANE ROOF ON COVER
BOARD
WOOD PLANK ROOF DECK, REPLACE
IN KIND, AS SHOWN ON STRUCTURAL
EXISTING STRUCTURE
EXISTING WALL
FLASHING
CLERESTORY WINDOW, REPLACE
GLASS PANEL IN KIND
CLERESTORY WINDOW, REPLACE
GLASS PANEL IN KIND
METAL EXTENDER AS REQUIRED
NEW ROOF MEMRANE
FLASHING ADHERED TO
SUBSTRATE
NEW THRU-WALL METAL
COUNTERFLASHING EMBEDDED
IN SEALANT
VAPOR RETARDER
STRUCTURAL DECK
COVERBOARD
M
IN
M
IN
EXTERIOR GYP. BOARD
PIPE
SEALANT
STAINLESS STEEL WORM GEAR CLAMP
FIELD FORMED FLASHING MEMBRANE
WITH ADHESIVE
FIELD FORMED FLASHING MEMBRANE
SINGLE-PLY ROOFING MEMBRANE
COVER BOARD
M
IN
EXISTING ROOF DECKING
EXTERIOR GYP. BOARD
EXTERIOR GYP. BOARD
TREATED WOOD NAILERS TO
MATCH HEIGHT OF EXTERIOR GYP
BOARD AND COVER BOARD
ROOFING MEMBRANE
NEW METAL GUTTER.
MATCH EXISTING
METAL FASTENER 4 IN. O.C.,
STAGGERED USING 1-INCH
GALVANIZED ANNULAR RING
NAILS OR OTHER ACCEPTABLE
FASTENER
STRUCTURAL DECK
VAPOR RETARDER
FLASHING STRIP
COVERBOARD1
G
TOP OF ROOF
33' - 6"
F V
A-501
A-501
RUBBER WALKBOARD
PAVER ADHERED TO
ROOF MEMBRANE
PROVIDE NEW GUTTER
NEW DOWNSPOUT
BEYOND
SEALANT AND
BACKER ROD
ALUMINUM
FRAME
GLAZING PANEL
EMBED FLASHING
IN SEALANT
SILL FLASHING
SEALANT AND
BACKER ROD
ALUMINUM
FRAME
GLAZING PANEL
CORNER BEAD
3-5/8 METAL STUDS,
SECURELY ANCHOR TO
STRUCTURE AS REQUIRED
ACOUSTICAL
CEILING TILE
BOTTOM OF CEILING
REFER TO RCP
BOTTOM OF SOFFIT
REFER TO RCP
5/8" GYP. BD.
BOTTOM OF CEILING
REFER TO RCP
GUARDRAIL POST
ANCHOR
BASE PLATE
FACE OF BLDG
FACE OF CANOPY
NEW 1/2" BIRD NETTING TO
MATCH EXISTING NETTING
NEW VELCRO TYPE
MAINTENANCE ACCESS
OPENINGS FOR SPRINKLER
AND ELECTRICAL SYSTEMS,
TYP BETWEEN ALL GRID
SPACES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N O
R F
O L K
D
IS
T R
IC
T
F
R O
N T
S T
R E
E T
N O
R F
O L K
V
IR
G
IN
IA
J
O N
E S
F R
A N
K L
IN
R D
S U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
(9
-7
F
A X
L
IC
E N
S E
F
-0
F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
N
A O
F
IL
E N
O
W -2
-B
-0
W -1
-F
-0
D S
A L T
S M
A N
FOR OFFICIAL USE ONLY
FOR CONSTRUCTION
A-501
M
IS
C E
L L A
N E
O U
S D
E T
A
IL
S
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D R
IC
H
M O
N D
V A
R M
O R
S O
N
T S
H O
U S
E
P Z
O O
K
M
A R
C H
R E
N O
V A
T
IO
N S
T O
B U
IL
D
IN
G
D
D R
V
P R
O J E
C T
N U
M B
E R
P
.0
.0
A -5
.D
W G
3" = 1'-0"A-501
3 TYPICAL HEAD KALWALL DETAIL
3" = 1'-0"A-501
4 TYPICAL SILL KALWALL DETAIL
1/2" = 1'-0"A-501
5 ROOF DECK REPAIR
3" = 1'-0"A-501
12 FLASHING AT CLERESTORY WINDOW
3" = 1'-0"A-501
6 FLASHING AT PIPE PENETRATIONS
3" = 1'-0"A-501
9 FLASHING AT GUTTER
3/4" = 1'-0"A-501
11 TYPICAL WALL SECTION AT KALWALL
3" = 1'-0"A-501
10 TYPICAL WINDOW SILL DETAIL
3" = 1'-0"A-501
7 TYPICAL HEAD DETAIL AT WINDOW
3" = 1'-0"A-501
8 ACT CEILING TO GYP CEILING
1 1/2" = 1'-0"A-501
1 GUARDRAIL POST DETAIL
1/4" = 1'-0"A-501
2 CANOPY SOFFIT ACCESS PLAN
A
M E
N D
M E
N T
/2
/2
A
M E
N D
M E
N T
/6
/2
| Sheets |
| A-101 - FLOOR PLAN - BAY A & B - PHASE 1 |
| A-131 - FINISH FLOOR PLAN - BAY A & B - PHASE 1 |
| A-132 - FINISH FLOOR PLAN - BAY C & D - PHASE 2 |
| A-133 - FINISH FLOOR PLAN - BAY E & F - PHASE 3 |
| A-134 - FINISH FLOOR PLAN - BAY G & H - PHASE 4 |
| A-135 - FINISH FLOOR PLAN - BAY I & K - PHASE 5 |
| A-136 - FINISH FLOOR PLAN - BAY L - PHASE 6 |
| A-310 - TRANSVERSE BUILDING SECTIONS |
| A-311 - TRANSVERSE BUILDING SECTIONS |
| A-321 - WALL SECTIONS |
| A-401 - ENLARGED FLOOR PLANS |
| A-403 - ENLARGED FLOOR PLANS AND SECTIONS |
| A-404 - ENLARGED TOILET PLANS, SECTIONS, AND ELEVATIONS |
| A-405 - ENLARGED TOILET PLANS, SECTIONS, AND ELEVATIONS |
| A-501 - MISCELLANEOUS DETAILS |
| AD102 - DEMOLITION FLOOR PLAN - BAY C & D - PHASE 2 |
| AD103 - DEMOLITION FLOOR PLAN - BAY E & F - PHASE 3 |
| G-001 - COVER SHEET |
| G-002 - SHEET INDEX |
File details come from the government source that posted it. Updated .