A-501.pdf

PDF 244 KB Posted

Attached to
DLA Warehouse 11 Renovation Federal contract opportunity
Solicitation number
W9123620B0017
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document package includes construction plans and specifications for renovations to Building 11 of the Defense Supply Center Richmond in Richmond, Virginia. The solicitation number is W9123620B0017 and is seeking bids for renovations including replacing glass panels, installing new roof membranes, repairing roof decks, and other miscellaneous construction details. The solicitation is posted electronically with bids only accepted in electronic form. The agency issuing this IFB is the Department of the Army Corps of Engineers Engineering District Norfolk. The document provides detailed drawings and specifications for the renovation work required.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Warehouse 11 Renovation, newest first.
File Type Posted
Warehouse 11 KO Signed Page 1.pdf PDF
Warehouse 11 page 3.pdf PDF
Warehouse 11 page 4.pdf PDF
Warehouse 11 page 2.pdf PDF
ProjNet Responses Amend 7.pdf PDF
20-B-0017 Amendment 7.pdf PDF
20-B-0017 Amendment 6.pdf PDF
AD102.pdf PDF
23 52 43.00 20.pdf PDF
08 51 00.pdf PDF
G-001.pdf PDF
AD103.pdf PDF
PD102.pdf PDF
A-133.pdf PDF
09 29 00.pdf PDF
A-134.pdf PDF
A-136.pdf PDF
01 33 29.pdf PDF
01 11 00.05 50.pdf PDF
A-321.pdf PDF
A-311.pdf PDF
01 32 01.00 10.pdf PDF
A-403.pdf PDF
A-401.pdf PDF
PROJECT.pdf PDF
20B0017 Amendment 5.pdf PDF
A-132.pdf PDF
REGISTER.pdf PDF
A.01.13 Specs Table of Contents.pdf PDF
A.01.13 A-321.pdf PDF
A.01.13 AD100.pdf PDF
A.01.13 A-100.pdf PDF
A.01.13 07 54 19.pdf PDF
A.01.13 A-403.pdf PDF
A.01.13 10 81 00.pdf PDF
A.01.13 A-113.pdf PDF
A.01.13 A-501.pdf PDF
A.01.13 A-111.pdf PDF
A.01.13 A-112.pdf PDF
A.01.13 A-310.pdf PDF
A.01.13 A-202.pdf PDF
A.01.13 A-201.pdf PDF
A.01.13 A-203.pdf PDF
20-B-0017 Amendment 3.pdf PDF
A.01.13 A-116.pdf PDF
WH 11 Site Visit.pdf PDF
_RTA_Reno_to_Bldg_11_DDRV_Full_Plan_Set.pdf PDF
_P_2015_01503_003_specs_RTA.pdf PDF
A.01.13 WH11 Final Specifications.pdf PDF
20-F-0017 WH 11.pdf PDF
Show all 50

DLA Warehouse 11 Renovation has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GL GL

KALWALL TRANSLUCENT BACK UP PANEL

AT BAY L CLERESTORY ONLY. CLEAN

EXISTING / NEW GLASS INTERIOR SURFACE

PRIOR TO INSTALLATION OF KALWALL

EXISTING WALL

FLASHING

CLERESTORY WINDOW,

REPLACE GLASS PANEL

IN KIND

BLOCKING AS REQUIRED

KALWALL TRANSLUCENT BACK UP

PANEL AT BAY L CLERESTORY

ONLY. CLEAN EXISTING / NEW

GLASS INTERIOR SURFACE PRIOR

TO INSTALLATION OF KALWALL

EXISTING WALL

SILL FLASHING

CLERESTORY WINDOW,

REPLACE GLASS PANEL IN

KIND

BLOCKING AS REQUIRED

NEW MEMBRANE ROOF ON COVER

BOARD

WOOD PLANK ROOF DECK, REPLACE

IN KIND, AS SHOWN ON STRUCTURAL

EXISTING STRUCTURE

EXISTING WALL

FLASHING

CLERESTORY WINDOW, REPLACE

GLASS PANEL IN KIND

CLERESTORY WINDOW, REPLACE

GLASS PANEL IN KIND

METAL EXTENDER AS REQUIRED

NEW ROOF MEMRANE

FLASHING ADHERED TO

SUBSTRATE

NEW THRU-WALL METAL

COUNTERFLASHING EMBEDDED

IN SEALANT

VAPOR RETARDER

STRUCTURAL DECK

COVERBOARD

M

IN

M

IN

EXTERIOR GYP. BOARD

PIPE

SEALANT

STAINLESS STEEL WORM GEAR CLAMP

FIELD FORMED FLASHING MEMBRANE

WITH ADHESIVE

FIELD FORMED FLASHING MEMBRANE

SINGLE-PLY ROOFING MEMBRANE

COVER BOARD

M

IN

EXISTING ROOF DECKING

EXTERIOR GYP. BOARD

EXTERIOR GYP. BOARD

TREATED WOOD NAILERS TO

MATCH HEIGHT OF EXTERIOR GYP

BOARD AND COVER BOARD

ROOFING MEMBRANE

NEW METAL GUTTER.

MATCH EXISTING

METAL FASTENER 4 IN. O.C.,

STAGGERED USING 1-INCH

GALVANIZED ANNULAR RING

NAILS OR OTHER ACCEPTABLE

FASTENER

STRUCTURAL DECK

VAPOR RETARDER

FLASHING STRIP

COVERBOARD1

G

TOP OF ROOF

33' - 6"

F V

A-501

A-501

RUBBER WALKBOARD

PAVER ADHERED TO

ROOF MEMBRANE

PROVIDE NEW GUTTER

NEW DOWNSPOUT

BEYOND

SEALANT AND

BACKER ROD

ALUMINUM

FRAME

GLAZING PANEL

EMBED FLASHING

IN SEALANT

SILL FLASHING

SEALANT AND

BACKER ROD

ALUMINUM

FRAME

GLAZING PANEL

CORNER BEAD

3-5/8 METAL STUDS,

SECURELY ANCHOR TO

STRUCTURE AS REQUIRED

ACOUSTICAL

CEILING TILE

BOTTOM OF CEILING

REFER TO RCP

BOTTOM OF SOFFIT

REFER TO RCP

5/8" GYP. BD.

BOTTOM OF CEILING

REFER TO RCP

GUARDRAIL POST

ANCHOR

BASE PLATE

FACE OF BLDG

FACE OF CANOPY

NEW 1/2" BIRD NETTING TO

MATCH EXISTING NETTING

NEW VELCRO TYPE

MAINTENANCE ACCESS

OPENINGS FOR SPRINKLER

AND ELECTRICAL SYSTEMS,

TYP BETWEEN ALL GRID

SPACES

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N O

R F

O L K

D

IS

T R

IC

T

F

R O

N T

S T

R E

E T

N O

R F

O L K

V

IR

G

IN

IA

J

O N

E S

F R

A N

K L

IN

R D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

F

IL

E N

A M

E

C A

T E

G O

R Y

C O

D E

N

A O

F

IL

E N

O

W -2

-B

-0

W -1

-F

-0

D S

A L T

S M

A N

FOR OFFICIAL USE ONLY

FOR CONSTRUCTION

A-501

M

IS

C E

L L A

N E

O U

S D

E T

A

IL

S

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D R

IC

H

M O

N D

V A

R M

O R

S O

N

T S

H O

U S

E

P Z

O O

K

M

A R

C H

R E

N O

V A

T

IO

N S

T O

B U

IL

D

IN

G

D

D R

V

P R

O J E

C T

N U

M B

E R

P

.0

.0

A -5

.D

W G

3" = 1'-0"A-501

3 TYPICAL HEAD KALWALL DETAIL

3" = 1'-0"A-501

4 TYPICAL SILL KALWALL DETAIL

1/2" = 1'-0"A-501

5 ROOF DECK REPAIR

3" = 1'-0"A-501

12 FLASHING AT CLERESTORY WINDOW

3" = 1'-0"A-501

6 FLASHING AT PIPE PENETRATIONS

3" = 1'-0"A-501

9 FLASHING AT GUTTER

3/4" = 1'-0"A-501

11 TYPICAL WALL SECTION AT KALWALL

3" = 1'-0"A-501

10 TYPICAL WINDOW SILL DETAIL

3" = 1'-0"A-501

7 TYPICAL HEAD DETAIL AT WINDOW

3" = 1'-0"A-501

8 ACT CEILING TO GYP CEILING

1 1/2" = 1'-0"A-501

1 GUARDRAIL POST DETAIL

1/4" = 1'-0"A-501

2 CANOPY SOFFIT ACCESS PLAN

A

M E

N D

M E

N T

/2

/2

A

M E

N D

M E

N T

/6

/2

Sheets
A-101 - FLOOR PLAN - BAY A & B - PHASE 1
A-131 - FINISH FLOOR PLAN - BAY A & B - PHASE 1
A-132 - FINISH FLOOR PLAN - BAY C & D - PHASE 2
A-133 - FINISH FLOOR PLAN - BAY E & F - PHASE 3
A-134 - FINISH FLOOR PLAN - BAY G & H - PHASE 4
A-135 - FINISH FLOOR PLAN - BAY I & K - PHASE 5
A-136 - FINISH FLOOR PLAN - BAY L - PHASE 6
A-310 - TRANSVERSE BUILDING SECTIONS
A-311 - TRANSVERSE BUILDING SECTIONS
A-321 - WALL SECTIONS
A-401 - ENLARGED FLOOR PLANS
A-403 - ENLARGED FLOOR PLANS AND SECTIONS
A-404 - ENLARGED TOILET PLANS, SECTIONS, AND ELEVATIONS
A-405 - ENLARGED TOILET PLANS, SECTIONS, AND ELEVATIONS
A-501 - MISCELLANEOUS DETAILS
AD102 - DEMOLITION FLOOR PLAN - BAY C & D - PHASE 2
AD103 - DEMOLITION FLOOR PLAN - BAY E & F - PHASE 3
G-001 - COVER SHEET
G-002 - SHEET INDEX

File details come from the government source that posted it. Updated .