A.01.13 A-113.pdf
PDF 164 KB Posted
- Attached to
- DLA Warehouse 11 Renovation Federal contract opportunity
- Solicitation number
- W9123620B0017
About this file
This document contains a roof plan drawing and related federal contract opportunity notice for building renovations. The roof plan drawing depicts proposed roof repairs and replacements to Bays E and F of Building 11 at the Defense Supply Center in Richmond, Virginia. Work includes repairing the roof deck, replacing flashing, installing new roofing, insulation and gutters, and replacing roof ventilator fans from demolition with new flashing. The related solicitation posted by the U.S. Army Corps of Engineers seeks electronic bids by March 12, 2020 for renovations to Building 11 under Solicitation Number W9123620B0017. Only electronic submissions will be accepted in response to the IFB, which provides additional details on the procurement.
View the file
Other files for this federal contract opportunity
Show all 50
DLA Warehouse 11 Renovation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
I
H
G
F
E
D
C
B
A
25 26 27 28 29 30 31 32 33 34 35 36 37
A -1
A -1
F V
F V
F V
F V
F V
F V
F V
F V
20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV
NEW DOWNSPOUT BELOW, TYP.
NEW DOWNSPOUT BELOW, TYP.
NEW DOWNSPOUT
NEW DOWNSPOUT
, TYP.
, TYP.
A-501
12_______
A-501
9_______
NEW GUTTER
NEW GUTTER
DOWNSPOUT, TYP.
PROVIDE WALKWAY PAD UNDER
DISHARGE. WALKWAY PAD, TYP
NEW WALKWAY
T Y
P
NEW METAL LADDER
NEW METAL LADDER
1 1
REPLACE ROOF VENTILATOR FANS SALVAGED
FROM DEMOLITION ON EXISTING ROOF
OPENINGS. PROVIDE NEW FLASHING TO NEW
ROOF MEMBRANE. PAINT FAN HOUSING, TYP
GENERAL NOTES
1. REPAIR ROOF DECK PER SHEETS S-111 THROUGH S-116.
2. FLASHING TO BE REPLACED, SEE DETAIL ON SHEET A-501
3. NEW ROOF, INSULATION, FLASHING, GUTTERS AND
DOWNSPOUTS, TYPICAL.
0' 8' 16' 32' 64'
KEY PLAN
CB DA E F G H I K L
T R
U E
N O
R T H
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N O
R F
O L K
D
IS
T R
IC
T
F
R O
N T
S T
R E
E T
N O
R F
O L K
V
IR
G
IN
IA
J
O N
E S
F R
A N
K L
IN
R D
S U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
(9
-7
F
A X
L
IC
E N
S E
F
-0
F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
N
A O
F
IL
E N
O
W -2
-B
-0
W -1
-F
-0
D S
A L T
S M
A N
FOR OFFICIAL USE ONLY
FOR CONSTRUCTION
A-113
R O
O F
P L A
N
B A
Y E
F
P
H A
S E
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D R
IC
H
M O
N D
V A
R M
O R
S O
N
T S
H O
U S
E
P Z
O O
K
M
A R
C H
R E
N O
V A
T
IO
N S
T O
B U
IL
D
IN
G
D
D R
V
P R
O J E
C T
N U
M B
E R
P
.0
.0
A -1
.D
W G
1/16" = 1'-0"A-113
1 ROOF PLAN – BAY E & F - PHASE 3