A.01.13 A-311.pdf
PDF 254 KB Posted
- Attached to
- DLA Warehouse 11 Renovation Federal contract opportunity
- Solicitation number
- W9123620B0017
About this file
This document contains construction drawings and specifications for renovations to Building 11 at the Defense Supply Center Richmond in Richmond, Virginia. The drawings include six transverse building section sheets showing details of the unisex toilet room, community room, riser room, boiler room, break room, and office areas. Renovations include upgrades to these existing spaces. The related federal contract opportunity is a solicitation issued by the Department of the Army Corps of Engineers Engineering District Norfolk seeking bids for the DLA Warehouse 11 Renovation project. The IFB is posted electronically only and bids must be submitted electronically by the date specified in the IFB.
View the file
Other files for this federal contract opportunity
Show all 50
DLA Warehouse 11 Renovation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GRADE
0"
LEVEL 1
3' - 6"
C B A
TOP OF ROOF
33' - 6"
A-301
1_______
A-301
1_______
A-301
2_______
A-301
2_______
A-321
UNISEX
11C-2
TRANSPORTATION
POINT 1
11C-1 UNISEX
11C-3
GRADE
0"
LEVEL 1
3' - 6"
C B A
TOP OF ROOF
33' - 6"
A-301
1_______
A-301
1_______
A-301
2_______
A-301
2_______
COMM ROOM
11C-4
OFFICE C
11C-5
A-321
GRADE
0"
LEVEL 1
3' - 6"
C B A
TOP OF ROOF
33' - 6"
A-303
1_______
A-303
1_______
A-303
2_______
A-303
2_______
TRANSPORTATION
POINT 3
11I-1
MEN'S TOILET
11I-3
A-321
A-501
GRADE
0"
LEVEL 1
3' - 6"
A
TOP OF ROOF
33' - 6"
BOILER
11-L1
A-501
A-321
GRADE
0"
LEVEL 1
3' - 6"
C B A
TOP OF ROOF
33' - 6"
A-302
1_______
A-302
1_______
A-302
2_______
A-302
2_______
BREAK ROOM F
11F-2
WOMEN'S
TOILET
11F-3
MEN'S TOILET
11F-4
A-321
GRADE
0"
LEVEL 1
3' - 6"
C B A
TOP OF ROOF
33' - 6"
A-302
1_______
A-302
1_______
A-302
2_______
A-302
2_______
OFFICE F
11F-5
OFFICE
11F-6 A-321
A-501
0' 4' 8' 16' 32'
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N O
R F
O L K
D
IS
T R
IC
T
F
R O
N T
S T
R E
E T
N O
R F
O L K
V
IR
G
IN
IA
J
O N
E S
F R
A N
K L
IN
R D
S U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
(9
-7
F
A X
L
IC
E N
S E
F
-0
F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
N
A O
F
IL
E N
O
W -2
-B
-0
W -1
-F
-0
D S
A L T
S M
A N
FOR OFFICIAL USE ONLY
FOR CONSTRUCTION
A-311
T R
A N
S V
E R
S E
B U
IL
D
IN
G
S E
C T
IO
N
S
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D R
IC
H
M O
N D
V A
R M
O R
S O
N
T S
H O
U S
E
P Z
O O
K
M
A R
C H
R E
N O
V A
T
IO
N S
T O
B U
IL
D
IN
G
D
D R
V
P R
O J E
C T
N U
M B
E R
P
.0
.0
A -3
.D
W G
1/8" = 1'-0"A-311
TRANSVERSE BUILDING SECTION -
UNISEX TOILET ROOM
1/8" = 1'-0"A-311
TRANSVERSE BUILDING SECTION -
COMM ROOM
1/8" = 1'-0"A-311
TRANSVERSE BUILDING SECTION -
RISER ROOM I
1/8" = 1'-0"A-311
TRANSVERSE BUILDING SECTION -
BOILER ROOM
1/8" = 1'-0"A-311
TRANSVERSE BUILDING SECTION -
BREAK ROOM
1/8" = 1'-0"A-311
TRANSVERSE BUILDING SECTION -
OFFICE F
A
M E
N D
M E
N T
A P
R
File details come from the government source that posted it. Updated .