A-502.pdf

PDF 178 KB Posted

Attached to
DLA Warehouse 11 Renovation Federal contract opportunity
Solicitation number
W9123620B0017
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document contains construction drawings and details for fire penetration systems in gypsum wall assemblies. Key details include specifications for cable, pipe, and conduit penetrations of single and double layer gypsum wallboard assemblies, showing various firestop materials and methods for achieving one-hour and two-hour fire resistance ratings. Also included are details for plastic and metal pipe sleeves, insulation, wraps and collars. The related federal contract opportunity is a sealed bid solicitation from the Department of the Army Corps of Engineers for renovations to Defense Supply Center Richmond Building 11 in Virginia. Bids must be submitted electronically by the date specified in the solicitation. The work includes building renovations with construction details provided in the drawings.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Warehouse 11 Renovation, newest first.
File Type Posted
Warehouse 11 KO Signed Page 1.pdf PDF
Warehouse 11 page 4.pdf PDF
Warehouse 11 page 2.pdf PDF
ProjNet Responses Amend 7.pdf PDF
20-B-0017 Amendment 7.pdf PDF
AD102.pdf PDF
23 52 43.00 20.pdf PDF
A-501.pdf PDF
08 51 00.pdf PDF
G-001.pdf PDF
AD103.pdf PDF
PD102.pdf PDF
A-133.pdf PDF
09 29 00.pdf PDF
A-403.pdf PDF
A-401.pdf PDF
PROJECT.pdf PDF
20B0017 Amendment 5.pdf PDF
A-132.pdf PDF
REGISTER.pdf PDF
G-002.pdf PDF
A-131.pdf PDF
A-134.pdf PDF
A-136.pdf PDF
01 33 29.pdf PDF
01 11 00.05 50.pdf PDF
A-321.pdf PDF
A-311.pdf PDF
A.01.13 Specs Table of Contents.pdf PDF
A.01.13 A-321.pdf PDF
A.01.13 AD100.pdf PDF
A.01.13 A-100.pdf PDF
A.01.13 07 54 19.pdf PDF
A.01.13 A-403.pdf PDF
A.01.13 10 81 00.pdf PDF
A.01.13 A-113.pdf PDF
A.01.13 A-201.pdf PDF
A.01.13 A-203.pdf PDF
20-B-0017 Amendment 3.pdf PDF
A.01.13 A-116.pdf PDF
A.01.13 A-501.pdf PDF
A.01.13 A-111.pdf PDF
A.01.13 A-112.pdf PDF
A.01.13 A-310.pdf PDF
A.01.13 A-202.pdf PDF
WH 11 Site Visit.pdf PDF
_RTA_Reno_to_Bldg_11_DDRV_Full_Plan_Set.pdf PDF
_P_2015_01503_003_specs_RTA.pdf PDF
A.01.13 WH11 Final Specifications.pdf PDF
20-F-0017 WH 11.pdf PDF
Show all 50

DLA Warehouse 11 Renovation has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

• 150 PAIR 24 AWG, 10 AWG ROMEXFIBER

OPTIC, 12 AWG CABLE, FOUR CONDUCTOR

NO.2 CABLE

• 2 HOUR RATING WITH

DOUBLE LAYER GYPSUM

WALLBOARD ASSEMBLY

(2 HOUR ASEMBLY

SHOWN)

• 1 HOUR RATING WITH

SINGLE LAYER

GYPSUM WALLBOARD

ASSEMBLY

STEEL STUD

INSULATED CABLE

FIRE

BARRIER

CAULK OR

PUTTY

MAXIMUM PENETRATING ITEM(S)

FIRE RATINGS

• 350 KC MIL POWER CABLES, 200 PAIR NO.24 AWG

CABLES, 7/C NO.210 AWG CABLE, 3C NO.210AWG CABLES

6/94 FIBER OPTIC CABLE, NO.2 AWG ARMORED CABLE, 28

GAUGE STEEL SLEEVE

P E

R C

E N

T A

G E

F U

L L

I S

F O

R

O

P E

N

IN

G

STEEL STUD

CABLE BUNDLES

1" DEPTH

FIRE BARRIER CAULK

PACKING

MATERIAL 1"

DEPTH

1/4" BEAD OF FIRESTOP FIRE

BARRIER

CAULK - WORK IN BETWEEN

INDIVIDUAL

CABLES IN BUNDLE FOR

IMPROVED SMOKE SEAL

2 HOUR GYPSUM WALLBOARD

PROTRUDE 1/2" BEYOND WALL

28 GAUGE STEEL SLEEVE

ASSEMBLY

M A

X O

P E

N

IN

G

MAXIMUM PENETRATING ITEM(S)

• 1 HOUR RATING WITH

SINGLE

LAYERGYPSUM

WALLBOARD

ASSEMBLY

• 2 HOUR RATING WITH

DOUBLE LAYER

GYPSUM WALLBOARD

ASSEMBLY ( 2 HOUR

ASSEMBLY SHOWN )

FIRE RATINGS

MINIMUM 30 GA METAL SLEEVE

FIRE BARRIER

CAULK OR PUTTY

• 6" TO 10" PVC, 1" GLASS FIBER, STEEL SLEEVE

1" THICK CYLINDRICAL GLASS

FIBER PIPE INSULATION - 6" MIN.

LENGTH

STEEL STUDS

FIRE BARRIER

WRAP/STRIPS

STEEL TIE WIRE

STEEL BAND CLAMP

NOMINAL MAX PENETRATING ITEM(S)

STEEL STUDFIRE BARRIER CAULK

• 6" PVC, 6" CPVC, 4" FRPP, 4" ABS, 1" EMT, 1" GLASS FIBER

1 HOUR FIRE RATED GYPSUM

WALLBOARD ASSEMBLY IS SHOWN

FIRE BARRIER RESTRICTING COLLAR

STEEL BAND CLAMP

OR PUTTY

PLASTIC PIPE/CONDUIT

FIRE BARRIER

WRAP/STRIPS

WALL ANCHORS

NOMINAL MAX PENETRATING ITEM(S)

• 2 HOUR RATING WITH DOUBLE

LAYER GYPSUM WALLBOARD

ASSEMBLY ( 2 HOUR ASSEMBLY

SHOWN )

• 1 HOUR RATING WITH SINGLE

LAYER GYPSUM WALLBOARD

ASSEMBLY

1/4" BEADS OF

STEEL STUD

• 12" STEEL, 6" COPPER, 2" GLASS FIBER

1/2" MINIMUM TO 3/4" MAX

ANNULAR SPACE FOR 2"

INSULATION

WRAP/STRIP

FIRE BARRIER

GLASS INSUL. JACKETED

1" TO 2" MAX FIBER

FIRE BARRIER CAULK

FIRE RATINGS

NOMINAL MAX PENETRATING ITEM(S)

• 2 HOUR RATING

WITH DOUBLE

LAYER GYPSUM

WALLBOARD

ASSEMBLY( 2 HOUR

ASSEMBLY SHOWN )

• 1, 2, 3 OR 4HR.

GYPSUM

WALLBOARD

ASSEMBLY

FIRE RATINGS

FIRE BARRIER CAULK

STEEL STUD

• 12" STEEL, 12" CAST

IRON, 6" CONDUIT 6"

EMT, 6" COPPER

ANNULAR SPACE

FOR 12" STEEL PIPE

3/8" MAX

NOMINAL MAX PENETRATING ITEM(S)

2 - #3

3/8" TOOLED EDGE (TYP.)

L PARKING STALLC

WHEEL STOP3'-0" TO EDGE

OF PARKING STALL

PAINTED STRIPES IF SHOWN ON THE

DRAWINGS OR REQ'D BY THE SPECIFICATIONS

1'-0" 1'-0"1'-0"2'-0" (MIN.) 2'-0" (MIN.)

6 1/2"6 1/2"

5 1/2 "

DRAINAGE

OPENING OPENING

DRAINAGE

7'-0" (MIN.)

8'-0" (MAX.)

/2

/2

(M

IN

1/2" STD PIPE OR 3/4" REINF. ROD

SHALL BE PLACED PRIOR TO SURFACING

OR IN A HOLE DRILLED IN THE

FINISHED SURFACE WITH A TIGHT

FIT OBTAINED BY AN APPROVED

METHOD, OR DRIVEN INTO THE SURFACING

(OPTIONAL 1"x3" HOLE)

HOLE FOR 1/2" STD. PIPE OR

1/2" MAX.

CLEARANCE

3/8" TOOLED EDGE (TYP.)

3/4" DIAM. REINF. ROD

A-502

7_______

A-502

7_______

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N O

R F

O L K

D

IS

T R

IC

T

F

R O

N T

S T

R E

E T

N O

R F

O L K

V

IR

G

IN

IA

J

O N

E S

F R

A N

K L

IN

R D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

F

IL

E N

A M

E

C A

T E

G O

R Y

C O

D E

N

A O

F

IL

E N

O

W -2

-B

-0

W -1

-F

-0

D S

A L T

S M

A N

FOR OFFICIAL USE ONLY

FOR CONSTRUCTION

A-502

P E

N E

T R

A T

IO

N

D E

T A

IL

S

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D R

IC

H

M O

N D

V A

R M

O R

S O

N

T S

H O

U S

E

P Z

O O

K

M

A R

C H

R E

N O

V A

T

IO

N S

T O

B U

IL

D

IN

G

D

D R

V

P R

O J E

C T

N U

M B

E R

P

.0

.0

A -5

.D

W G

1 1/2" = 1'-0"A-502

INSULATED CABLE THROUGH A

GYPSUM WALLBOARD ASSEMBLY

1 1/2" = 1'-0"A-502

CABLE BUDLE THROUGH GYPSUM

WALLBOARD ASSUMBLY

1 1/2" = 1'-0"A-502

NON-METALLIC PIPE THROUGH A

GYPSUM WALLBOARD ASSEMBLY

1 1/2" = 1'-0"A-502

NON-METALLIC PIPE/CONDUIT

THROUGH A GYPSUM WALLBOARD

ASSEMBLY

1 1/2" = 1'-0"A-502

SINGLE INSULATED METAL PIPE

THROUGH GYPSUM WALLBOARD

ASSEMBLY

1 1/2" = 1'-0"A-502

SINGLE PIPE/CONDUIT THROUGH A

GYPSUM WALLBOARD ASSEMBLY

A

M E

N D

M E

N T

/6

/2

1/4" = 1'-0"A-502

7 WHEEL STOP - SECTION

1/4" = 1'-0"A-502

8 WHEEL STOP - PLAN

1/4" = 1'-0"A-502

9 WHEEL STOP - ELEVATION

Sheets
A-401 - ENLARGED FLOOR PLANS
A-502 - PENETRATION DETAILS

File details come from the government source that posted it. Updated .