A-101.pdf
PDF 178 KB Posted
- Attached to
- DLA Warehouse 11 Renovation Federal contract opportunity
- Solicitation number
- W9123620B0017
About this file
This set of construction drawings and related solicitation provide details for the DLA Warehouse 11 Renovation project. The drawings include floor plans for phases 1 through 6 of the renovation for bays A through L, transverse and wall building sections, enlarged floor plans, toilet plans and sections, and miscellaneous details. The solicitation is for the full renovation and is posted as IFB W9123620B0017, with electronic bid submissions due as specified in the IFB and no phone inquiries accepted. The opportunity is with the Department of the Army Corps of Engineers Norfolk District for renovations to Building 11 of the Defense Supply Center Richmond in Richmond, Virginia.
View the file
Other files for this federal contract opportunity
Show all 50
DLA Warehouse 11 Renovation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13
A-310
1_______
A-310
1_______
BAY A
11-A
BAY B
11-B
A -1
149 148
103 104
PUMP ROOM
11A-1
PUMP ROOM
11B-1
A-201
A -2
A-202
F V
F V
F V
F V
F V
F V
F V
F V
20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV
A-403
A-403
1'-3" +/- FV
NOTE: DIMENSIONS TYPICAL, ALL BAYS
120'-0" +/- FV
N O
T E
D
IM
E
N S
IO
N
S T
Y P
IC
A
L A
L L B
A Y
S
F
V
101 102 105 106
A-403
REPLACE IN KINDREPLACE IN KIND
EXISTING FIXED LADDER
GENERAL NOTES
1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO:
- FACE OF GWB
- FACE OF MASONRY
- FACE OF CONCRETE
2. SEE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE
PROTECTION (M.E.P.) DRAWINGS AND ENLARGED ARCHITECTURAL PLANS
FOR INFORMATION NOT SHOWN ON THIS SHEET.
3. COORDINATE AND PROVIDE BLOCKING IN PARTITIONS FOR THE
INSTALLATION AND ATTACHMENT OF ALL WALL MOUNTED EQUIPMENT AND
PRODUCTS. ALL CONCEALED BLOCKING SHALL BE FIRE RETARDENT
TREATED. SEE ARCHITECTURAL PLANS AND M.E.P. DRAWINGS FOR THE
LOCATIONS OF WALL MOUNTED EQUIPMENT AND PRODUCTS.
0' 8' 16' 32' 64'
KEY PLAN
CB DA E F G H I K L
T R
U E
N O
R T H
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N O
R F
O L K
D
IS
T R
IC
T
F
R O
N T
S T
R E
E T
N O
R F
O L K
V
IR
G
IN
IA
J
O N
E S
F R
A N
K L
IN
R D
S U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
(9
-7
F
A X
L
IC
E N
S E
F
-0
F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
N
A O
F
IL
E N
O
W -2
-B
-0
W -1
-F
-0
D S
A L T
S M
A N
FOR OFFICIAL USE ONLY
FOR CONSTRUCTION
A-101
F L O
O R
P L A
N
B A
Y A
B
P
H A
S E
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D R
IC
H
M O
N D
V A
R M
O R
S O
N
T S
H O
U S
E
P Z
O O
K
M
A R
C H
R E
N O
V A
T
IO
N S
T O
B U
IL
D
IN
G
D
D R
V
P R
O J E
C T
N U
M B
E R
P
.0
.0
A -1
.D
W G
1/16" = 1'-0"A-101
1 FLOOR PLAN - BAY A & B - PHASE 1
A
M E
N D
M E
N T
/6
/2
| Sheets |
| A-101 - FLOOR PLAN - BAY A & B - PHASE 1 |
| A-131 - FINISH FLOOR PLAN - BAY A & B - PHASE 1 |
| A-132 - FINISH FLOOR PLAN - BAY C & D - PHASE 2 |
| A-133 - FINISH FLOOR PLAN - BAY E & F - PHASE 3 |
| A-134 - FINISH FLOOR PLAN - BAY G & H - PHASE 4 |
| A-135 - FINISH FLOOR PLAN - BAY I & K - PHASE 5 |
| A-136 - FINISH FLOOR PLAN - BAY L - PHASE 6 |
| A-310 - TRANSVERSE BUILDING SECTIONS |
| A-311 - TRANSVERSE BUILDING SECTIONS |
| A-321 - WALL SECTIONS |
| A-401 - ENLARGED FLOOR PLANS |
| A-403 - ENLARGED FLOOR PLANS AND SECTIONS |
| A-404 - ENLARGED TOILET PLANS, SECTIONS, AND ELEVATIONS |
| A-405 - ENLARGED TOILET PLANS, SECTIONS, AND ELEVATIONS |
| A-501 - MISCELLANEOUS DETAILS |
| AD102 - DEMOLITION FLOOR PLAN - BAY C & D - PHASE 2 |
| AD103 - DEMOLITION FLOOR PLAN - BAY E & F - PHASE 3 |
| G-001 - COVER SHEET |
| G-002 - SHEET INDEX |
File details come from the government source that posted it. Updated .