This roof plan drawing depicts proposed renovations to the roof of Building 11 at the Defense Supply Center Richmond in Richmond, Virginia. Key details include replacing sections of roof decking, installing new roofing membrane and insulation, replacing flashing, gutters and downspouts, and painting roof ventilator fans to be reinstalled. The project number is P2015.015030.003 and was drawn by D. Saltman for the U.S. Army Corps of Engineers Norfolk District.

The related federal contract opportunity is a solicitation posted by the Department of the Army Corps of Engineers Engineering District Norfolk. Solicitation number W9123620B0017 is for renovations to DLA Warehouse 11 and seeks electronic bid submissions by the deadline specified in the IFB. The opportunity is an invitation for bid where only electronic submissions will be accepted.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Warehouse 11 Renovation, newest first.
File Type Posted
Warehouse 11 KO Signed Page 1.pdf PDF
Warehouse 11 page 4.pdf PDF
Warehouse 11 page 2.pdf PDF
ProjNet Responses Amend 7.pdf PDF
20-B-0017 Amendment 7.pdf PDF
AD102.pdf PDF
23 52 43.00 20.pdf PDF
A-501.pdf PDF
08 51 00.pdf PDF
G-001.pdf PDF
AD103.pdf PDF
PD102.pdf PDF
A-133.pdf PDF
09 29 00.pdf PDF
A-403.pdf PDF
A-401.pdf PDF
PROJECT.pdf PDF
20B0017 Amendment 5.pdf PDF
A-132.pdf PDF
REGISTER.pdf PDF
G-002.pdf PDF
A-131.pdf PDF
A-134.pdf PDF
A-136.pdf PDF
01 33 29.pdf PDF
01 11 00.05 50.pdf PDF
A-321.pdf PDF
A-311.pdf PDF
01 32 01.00 10.pdf PDF
A.01.13 Specs Table of Contents.pdf PDF
A.01.13 A-321.pdf PDF
A.01.13 AD100.pdf PDF
A.01.13 A-100.pdf PDF
A.01.13 07 54 19.pdf PDF
A.01.13 A-403.pdf PDF
A.01.13 10 81 00.pdf PDF
A.01.13 A-113.pdf PDF
A.01.13 A-201.pdf PDF
A.01.13 A-203.pdf PDF
20-B-0017 Amendment 3.pdf PDF
A.01.13 A-116.pdf PDF
A.01.13 A-501.pdf PDF
A.01.13 A-111.pdf PDF
A.01.13 A-310.pdf PDF
A.01.13 A-202.pdf PDF
WH 11 Site Visit.pdf PDF
_RTA_Reno_to_Bldg_11_DDRV_Full_Plan_Set.pdf PDF
_P_2015_01503_003_specs_RTA.pdf PDF
A.01.13 WH11 Final Specifications.pdf PDF
20-F-0017 WH 11.pdf PDF
Show all 50

DLA Warehouse 11 Renovation has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

K

I

H

G

F

E

D

C

B

A

13 14 15 16 17 18 19 20 21 22 23 24 25

A -1

A -1

20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV 20'-0" +/- FV

NEW DOWNSPOUT , TYP.

NEW DOWNSPOUT BELOW, TYP.

NEW DOWNSPOUT BELOW, TYP.

NEW DOWNSPOUT , TYP.

A-501

12_______

A-501

9_______

NEW GUTTER

NEW GUTTER

DOWNSPOUT, TYP.

PROVIDE WALKWAY PAD UNDER

DISHARGE. WALKWAY PAD, TYP

NEW WALKWAY, TYP.

T Y

P

1 1

REPLACE ROOF VENTILATOR FANS SALVAGED

FROM DEMOLITION ON EXISTING ROOF

OPENINGS. PROVIDE NEW FLASHING TO NEW

ROOF MEMBRANE. PAINT FAN HOUSING, TYP

GENERAL NOTES

1. REPAIR ROOF DECK PER SHEETS S-111 THROUGH S-116.

2. FLASHING TO BE REPLACED, SEE DETAIL ON SHEET A-501

3. NEW ROOF, INSULATION, FLASHING, GUTTERS AND

DOWNSPOUTS, TYPICAL.

0' 8' 16' 32' 64'

KEY PLAN

CB DA E F G H I K L

T R

U E

N O

R T H

PLAN

NORTH

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N O

R F

O L K

D

IS

T R

IC

T

F

R O

N T

S T

R E

E T

N O

R F

O L K

V

IR

G

IN

IA

J

O N

E S

F R

A N

K L

IN

R D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

F

IL

E N

A M

E

C A

T E

G O

R Y

C O

D E

N

A O

F

IL

E N

O

W -2

-B

-0

W -1

-F

-0

D S

A L T

S M

A N

FOR OFFICIAL USE ONLY

FOR CONSTRUCTION

A-112

R O

O F

P L A

N

B A

Y C

D

P

H A

S E

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D R

IC

H

M O

N D

V A

R M

O R

S O

N

T S

H O

U S

E

P Z

O O

K

M

A R

C H

R E

N O

V A

T

IO

N S

T O

B U

IL

D

IN

G

D

D R

V

P R

O J E

C T

N U

M B

E R

P

.0

.0

A -1

.D

W G

1/16" = 1'-0"A-112

1 ROOF PLAN – BAY C & D - PHASE 2

A

M E

N D

M E

N T

A P

R

File details come from the government source that posted it. Updated .