A.01.13 AD100.pdf
PDF 201 KB Posted
- Attached to
- DLA Warehouse 11 Renovation Federal contract opportunity
- Solicitation number
- W9123620B0017
About this file
This document contains plans for the renovation of Building 11 at the Defense Supply Center in Richmond, Virginia. The plans detail the demolition required on the building's roof, including removing existing glass panels, downspouts, roof vents, gutters, flashing and roofing membrane. Temporary access towers must be installed for safe roof access. Hazardous materials inspections are also required. The related federal contract opportunity is solicitation number W9123620B0017 for the DLA Warehouse 11 Renovation project issued by the Department of the Army Corps of Engineers Norfolk District. Electronic bid submissions are required by the date specified in the solicitation.
View the file
Other files for this federal contract opportunity
Show all 50
DLA Warehouse 11 Renovation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67
BUILDING
ROAD E
N
D S
T R
E E
T
S
T S
T R
E E
T
BAY A BAY B BAY C BAY D BAY E BAY F BAY G BAY H BAY I BAY K BAY L
1111 11
11111111
A D
A D
A D
A D
A D
A D
A D
A D
A D
A D
11 11 11 11
11 11
11 11
19 191919191919 19 19 19 19
2020202020202020202020
212121212121
1 1
0' 25' 50' 100'
KEY PLAN
CB DA E F G H I K L
T R
U E
N O
R T H
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N O
R F
O L K
D
IS
T R
IC
T
F
R O
N T
S T
R E
E T
N O
R F
O L K
V
IR
G
IN
IA
J
O N
E S
F R
A N
K L
IN
R D
S U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
(9
-7
F
A X
L
IC
E N
S E
F
-0
F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
N
A O
F
IL
E N
O
W -2
-B
-0
W -1
-F
-0
D S
A L T
S M
A N
FOR OFFICIAL USE ONLY
FOR CONSTRUCTION
AD100
O V
E R
A L
L D
E M
O L
IT
IO
N R
O O
F P
L A
N
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D R
IC
H
M O
N D
V A
R M
O R
S O
N
T S
H O
U S
E
P Z
O O
K
M
A R
C H
R E
N O
V A
T
IO
N S
T O
B U
IL
D
IN
G
D
D R
V
P R
O J E
C T
N U
M B
E R
P
.0
.0
A D
.D
W G
1" = 50'-0"AD100
1 OVERALL DEMOLITION ROOF PLAN
DEMOLITION PLAN KEYNOTES
11 EXISTING BROKEN GLASS PANEL TO BE REMOVED AND REPLACED PER BAY
19 EXISTING DOWNSPOUTS FROM HIGHER ROOF AREA PENETRATE THE LOWER ROOF
AND EXTEND THROUGH THE FLOOR SLAB BELOW. REMOVE THE DOWNSPOUTS AND
REPAIR THE STRUCTURAL SLAB TO RECEIVE NEW ROOF SYSTEM
20 REMOVE EXISTING ROOF VENTS. SALVAGE FOR RE-USE. SEE MECHANICAL.
MAINTAIN EXISTING CURB / ROOF PENETRATIONS FOR REUSE WITH NEW ROOF
SYSTEM
21 REMOVE EXISTING GUTTER AT CLERESTORY ROOF
22 REMOVE ROOF AND TRIM AND MAKE READY FOR NEW ROOF AND TRIM
GENERAL NOTES
1. GENERAL CONTRACTOR SHALL PROVIDE OSHA CONFORMING
TEMPORARY STAIR TOWERS FOR SAFE ACCESS TO EACH ROOF
AREA SHOWN ON THIS SHEET. SLOPE OF STAIRS TO BE NOT LESS
THAN 30 DEGREES FROM HORIZONTAL AND NOT MORE THAN 45
DEGREES FROM HORIZONTAL. TEMPORARY STAIR TOWERS SHALL
BE INSTALLED BY GENERAL CONTRACTOR PRIOR TO START OF
ROOF DEMOLITION AND REMOVED BY GENERAL CONTRACTOR
UPON ACCEPTANCE BY THE GOVERNMENT OF COMPLETED ROOF.
2. COORDINATE WITH STRUCTURAL SHEETS.
3. DEMO EXISTING VENTS, EQUIPMENT OR OTHER ROOFTOP
PENETRATIONS. REMOVE ANY PIPE BOOTS, FLASHING, AND
SEALANTS AROUND EQUIPMENT.
4. REMOVE EXISTING INTERNAL DOWNSPOUTS ANDCAP AT SLAB SEE
9/S501 FOR DETAIL AND THEN SEE SHEETS AD101- AD106.
5. REPAIR DAMAGED WOOD ROOF DECK PER STRUCT DRAWINGS.
6. REMOVE ALL EXISTING ROOF MEMBRANE, INSULATION, GUTTERS,
DOWNSPOUTS, AND FLASHING.
HAZARDOUS BUILDING MATERIAL NOTES
1. NO HAZARDOUS BUILDING MATERIAL SURVEY PERFORMED ON
ROOF OR ROOF COMPONENTS. CONTRACTOR TO PERFORM PRIOR
TO DEMOLITION ACTIVITIES.
A
M E
N D
M E
N T
A P
R
File details come from the government source that posted it. Updated .