FSB2020-270-00 - WI-ANG - 3-Bay Hangar - Addendum 004 COMBINED DRAWINGS.pdf

PDF 6 MB Posted

Attached to
F-35 THREE BAY SPECIALIZED HANGAR
Solicitation number
W50S9F-22-B-0001
Issued by

About this file

This is a notice for an unrestricted invitation for bid to construct a new three-bay hangar and associated facilities at Truax Field, Madison, Wisconsin.

The project scope includes demolishing an existing 19,875 square foot building and constructing a new 31,000 square foot three-bay hangar compatible with the F-35 mission along with administrative and shop spaces. Key requirements include pre-conditioned aircraft air, 270VDC aircraft power, fire suppression, hangar bay HVAC, and space for a future paint booth and composite clean/dirty spaces. The facility will also require a lightning protection system, fall protection, and an Advantor security system.

The base bid is for new construction and demolition. Two options are included for a paint/mix addition and aircraft-rated pavement. The bid opening will be conducted on SAM.gov. The contract duration is 550 days from notice to proceed. The magnitude of construction is between $25-100 million. The solicitation requires brand name products including Advantor, Andover, Marshall Best, and Monaco systems. Award will be to the responsive and responsible lowest bidder.

View the file

Other files

File Type Posted
Bid Opening Attendance Sheet.pdf PDF
Abstract of Offers.pdf PDF
Questions and Answers 4.pdf PDF
39_ITEM 01.5-1_ADD 03_Bid Question Attachment_2022.06.14.pdf PDF
Question and Answer Set 4_Question 2_Custom Graphic.pdf PDF
W50S9F22B0001 Solicitation - Amend 0004.pdf PDF
22_ITEM 01.3-12_ADD 04_02700A-502.pdf PDF
19_ITEM 01.3-9_ADD 04_02700A-002.pdf PDF
00_FSB2020-270-00_WI-ANG_3-Bay_ADD NO. 04_2022.06.28_Narrative.pdf PDF
24_ITEM 01.3-14_ADD 04_02700A-702.pdf PDF
Questions and Answers 3.pdf PDF
25_ITEM 01.3-15_ADD 04_02700ES101.pdf PDF
10_ITEM 01.2-10_ADD 04_Section 32 13 14.13.pdf PDF
26_ITEM 01.3-16_ADD 04_02700EP102.pdf PDF
20_ITEM 01.3-10_ADD 04_02700A-140.pdf PDF
01_ITEM 01.2-1_ADD 04_PROJECT TOC.pdf PDF
15_ITEM 01.3-5_ADD 04_02700SF105.pdf PDF
23_ITEM 01.3-13_ADD 04_02700A-503.pdf PDF
03_ITEM 01.2-3_ADD 04_Section 07 21 13.pdf PDF
05_ITEM 01.2-5_ADD 04_Section 08 33 13.pdf PDF
07_ITEM 01.2-7_ADD 04_Section 09 90 00.pdf PDF
18_ITEM 01.3-8_ADD 04_02700SF504.pdf PDF
11_ITEM 01.3-1_ADD 04_02700C-301.pdf PDF
06_ITEM 01.2-6_ADD 04_Section 08 33 23.pdf PDF
09_ITEM 01.2-9_ADD 04_Section 11 94 00.01.pdf PDF
27_ITEM 01.3-17_ADD 04_02700EP701.pdf PDF
04_ITEM 01.2-4_ADD 04_Section 07 24 00.pdf PDF
16_ITEM 01.3-6_ADD 04_02700SF106.pdf PDF
28_ITEM 01.3-18_ADD 04_02700EP702.pdf PDF
14_ITEM 01.3-4_ADD 04_02700SF104.pdf PDF
17_ITEM 01.3-7_ADD 04_02700SF503.pdf PDF
02_ITEM 01.2-2_ADD 04_Section 04 20 00.pdf PDF
12_ITEM 01.3-2_ADD 04_02700C-401.pdf PDF
08_ITEM 01.2-8_ADD 04_Section 11 94 10.pdf PDF
21_ITEM 01.3-11_ADD 04_02700A-501.pdf PDF
13_ITEM 01.3-3_ADD 04_02700C-601.pdf PDF
W50S9F22B0001 Solicitation - Amend 0003.pdf PDF
28_ITEM 01.3-18_ADD 03_02700A-600.pdf PDF
24_ITEM 01.3-14_ADD 03_02700A-501.pdf PDF
01_ITEM 01.2-1_ADD 03_Section 02 65 00.pdf PDF
14_ITEM 01.3-4_ADD 03_02700C-402.pdf PDF
20_ITEM 01.3-10_ADD 03_02700A-002.pdf PDF
05_ITEM 01.2-5_ADD 03_Section 08 71 00.pdf PDF
Questions and Answers 2.pdf PDF
07_ITEM 01.2-7_ADD 03_Section 21 13 13.pdf PDF
FSB2020-270-00 - WI-ANG - 3-Bay Hangar - Addendum 003 Combined Drawings.pdf PDF
18_ITEM 01.3-8_ADD 03_02700SF103.pdf PDF
16_ITEM 01.3-6_ADD 03_02700C-601.pdf PDF
03_ITEM 01.2-3_ADD 03_Section 05 50 13.pdf PDF
09_ITEM 01.2-9_ADD 03_Section 26 05 26.00 40.pdf PDF
Show 40 more

Latest 50 of 147 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SS

SS

EEEEE

EEE

E E

E E E E

E E E E E E E E

E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

GGGGGGGGG

G

G G

G

G

G

G G

GG

G

G G

G

G

G

G

G

G

G

G

G

G G

G

G

G

G

SAN SAN SAN SAN SAN SAN

SAN

SAN

SAN

SAN

SAN

SANSAN

SAN

SAN

SAN SAN SAN

SAN

SAN

SAN

SAN

SA

N

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

T

T

T

T

TT

T

T

T

T

T

T

T

T

T

T

T

T

T

T

W W W W W W W W W W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W W

W W

W

W

W

W W

W

W

W

W

W

W

WWWWW WV

WV

WVWV WV

WV

TEL

WV

TEL

TEL

TEL

MWEL

WV

UT

UT

UT

WV

TEL

WV

MWEL

MWEL

UT

UT

MWEL

MWEL

UT

MWEL

MWEL

GV

GVGTST

WV

TEL

WV

MWEL

WV

A/C A/C EL

MWEL

SAN

AG

WV

AG

UT

BLDG

BLDG

BLDG

AG

AG

AG

UT

BLDG

UT

MWEL

MWEL

SAN

SAN

BLDG

BLDG

BLDG

BLDG

BLDG

MWEL

SAN

MWEL

GTST

WV

SS

WV

WV

WVWV

SAN

SAN

VENT

UT UT

A/C

UT

DOCK DOCK

TEL

A/C

BORE

AG

SS

SS

SSSSSSSS

EXISTING 18" RCP TO REMAIN

SS

SS

SS

SS

W W

W W

W

W

W

W

W

W

W

W

W

W W W

SS

SSEX

IS

TI

N G

2"

R C

P

TO

R

EM

AI

N

W

W

REMOVE BITUMINOUS

PAVEMENT (TYP.), 5,036 S.Y.

REMOVE PCC PAVEMENT,

1,447 S.Y.

REMOVE COMMUNICATION LINE,

202 L.F.

EXISTING WALL TO BE

REMOVED TO PROPOSED

PCC PAVEMENT LIMIT.

92 L.F.

REMOVE BITUMINOUS

PAVEMENT (OLI 2), 692 S.Y.

REMOVE ELECTRICAL,

COORDINATE WITH MADISON

GAS AND ELECTRIC

REMOVE FENCE, 317 L.F.

REMOVE GAS LINE, 129 L.F.

REMOVE MONITORING

WELL, 3 EACH.

REMOVE EXISTING SANITARY (TYP.),

540 L.F. AND 6 STRUCTURES.

REMOVE SIDEWALK,

2,454 S.F. (TYP.)

REMOVE STORM (TYP.), 773

L.F. AND 11 STRUCTURES.

REMOVE WATER LINE,

32 L.F. AND HYDRANT

EXISTING PCC

PAVEMENT

EXISTING

BUILDING TO BE

REMOVED

EXISTING

BITUMINOUS

PAVEMENT

EXISTING

BUILDING

EXISTING

BUILDING

EXISTING

BUILDING

EXISTING PCC

PAVEMENT

EXISTING

STRUCTURE TO

BE RELOCATED

BY THE

GOVERNMENT

PRIOR TO

CONSTRUCTION

REMOVE ELECTRICAL,

COORDINATE WITH MADISON

GAS AND ELECTRIC

REMOVE HYDRANT

REMOVE HYDRANT

REMOVE EXISTING UNDERGROUND

FUEL OIL, USED OIL, USED SOLVENT,

AND DETERGENT STORAGE TANKS.

INTRUSION DETECTION CABLES

AND GAP SENSORS TO BE

REMOVED AND REPLACED,

SPLICING WILL NOT BE ALLOWED.

WORK TO BE COORDINATED WITH

ADVANTOR.

REMOVE ELECTRICAL, COORDINATE

WITH MADISON GAS AND ELECTRIC

REMOVE CONCRETE

CURB AND GUTTER,

364 L.F.

REMOVE WATER LINE, 72 L.F. AND

CAP EXISTING LINE TO REMAIN

REMOVE TELEPHONE

PEDESTAL AND

PULLBOX

REMOVE EXISTING

BUILDING STRUCTURE, 10

BOLLARDS, AGGREGATE

BASE AND SIGN

FEDERAL AVIATION

ADMINISTRATION CABLE IN THIS

AREA, APPROXIMATELY 24" DEEP.

THIS CABLE CANNOT BE SPLICED

IF CUT AND WOULD NEED

REPLACED ITS ENTIRE LENGTH.

REMOVE

BITUMINOUS

PAVEMENT (OLI 2),

3,060 S.Y.

REMOVE MONITORING

WELL (OLI 2)

GAS TEST STATION TO

BE ADJUSTED (OLI 2)

SANITARY STRUCTURE

TO BE ADJUSTED (OLI 2)

ADDITIONAL PAVEMENT TO BE

REMOVED FOR UTILITY

REMOVAL OR INSTALLATION

SHALL BE REPLACED IN KIND,

SEE TYPICAL SECTIONS.

0 15' 30' 60'

N

PROPOSED

REMOVAL LEGEND

BITUMINOUS PAVEMENT

PCC PAVEMENT

SIDEWALK

WALL

CONCRETE CURB AND GUTTER

ELECTRICAL LINE

STORM DRAIN

WATER LINE

GAS LINE

COMMUNICATION LINE

SANITARY LINE

FENCE LINE

MONITORING WELL

WATER/SANITARY STRUCTURE

STORM STRUCTURE

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

-B ay S pe ci al iz ed H an ga r M ad is on , W is co ns in

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

LDH

Engineering | Planning | Allied Services

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

REMOVAL PLAN

C-301

LDH

HLE

1. EXISTING CONDITIONS ARE BASED ON SURVEY

PERFORMED BY KL ENGINEERING, INC. ON

06/2020.

2. OLI - OPTIONAL LINE ITEM

3. UTILITIES TO BE REMOVED UNDER MITCHELL

STREET SHALL BE PULLED IF WITHIN DUCTS,

DUCT MAY BE ABANDONED IN PLACE. OTHER

UTILITIES MAY BE CUT, CAPPED AND ABANDONED

IN PLACE UNDER THE ROAD IF THEY DO NOT

INTERFERE WITH PROPOSED CONSTRUCTION.

ADDENDUM 21 06/08/2022

ADDENDUM 42 06/28/2022

SS

EEEEE

EEE

E E

E E E E

E E E E E E E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

FO

FO

GGGGGGGGG

G

G G

G

G

G

G G

GG

G

G G

G

G

G

G

G

G

G

G

G G

G

G

G

G

SAN SAN SAN SAN SAN SAN

SAN

SAN

SAN

SAN

SAN

SANSAN

SAN

SAN

SAN SAN

SAN

SAN

SA

N

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

T

T

T

T

TT

T

T

T

T

T

T

T

T

T

T

T

T

T

W W W W W W W W W W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W W

W

W

W

W

W W

W

W

W

W

W

WWWWW WV

WV

WVWV WV

WV

TEL

WV

TEL

TEL

TEL

WV WV

WV

UT

UT

UT

WV

TEL

WV

UT

UT

UT

GV

GVGTST

WV

TEL

WV

WV

A/C A/C EL

SAN

AG

WV

AG

UT

UT

UT

SAN

SAN

SAN

GTST

WV

WV

WV

WVWV

SAN

SAN

VENT

UT UT

A/C

UT

DOCK DOCK

TEL

A/C

BORE

AG

SSSSSSSS

EXISTING 18" RCP TO REMAIN

SS

SS

W W

W W

W

W

W

W

W

W

W

W

W

W W W

SS

SSEX

IS

TI

N G

2"

R C

P

TO

R

EM

AI

N

W

W

PROPOSED PCC

PAVEMENT,

1,468 S.Y.

EXISTING PCC

PAVEMENT

F-35 3-BAY

SPECIALIZED

HANGAR

PROPOSED

AIRSIDE

BITUMINOUS

PAVEMENT (OLI 2),

1413 S.Y.

EXISTING

BITUMINOUS

PAVEMENT

EXISTING

BUILDING

EXISTING

BUILDING

EXISTING

BUILDING

EXISTING PCC

PAVEMENT

PROPOSED LANDSIDE

BITUMINOUS

PAVEMENT, 2,218 S.Y.

PROPOSED MARKING,

80 L.F.

PROPOSED 10' CHAIN

LINK FENCE WITH

VISUAL SLATS, 197 L.F.

PROPOSED DROP BEAM

BARRIER WITH KEYPAD AND

REMOTE ACROSS MITCHELL ST.

PROPOSED

SIDEWALK,

544 S.F.

PROPOSED LANDSIDE

BITUMINOUS PAVEMENT,

(OLI 1), 259 S.Y.

PROPOSED LANDSIDE

BITUMINOUS PAVEMENT, 175 S.Y.

PROPOSED LANDSIDE

BITUMINOUS PAVEMENT, 112 S.Y.

PROPOSED DOUBLE

SWING GATE 20 L.F.

OPENING

INTRUSION DETECTION CABLES

AND GAP SENSORS TO BE

REMOVED AND REPLACED,

SPLICING WILL NOT BE ALLOWED.

WORK TO BE COORDINATED WITH

ADVANTOR.

PROPOSED LANDSIDE

BITUMINOUS PAVEMENT,

143 S.Y.

PROPOSED 10' POST

AND PANEL WALL,

3 - 12' SECTIONS = 36 L.F.

PROPOSED 2' MOW

STRIP, TYP.

5'x5'

STOOP

5'x5'

STOOP

5'x5'

STOOP

PROPOSED

SIDEWALK, 1,087 S.F.

5'x8'

STOOP

(BASE BID)

PROPOSED SIDEWALK

(OLI 1), 141 S.F.

6'-10" x 10'-11"

MECHANICAL

PAD

2' MOW STRIP (BASE

BID), REMOVE FOR OLI 1

2' MOW STRIP (BASE

BID), REMOVE FOR OLI 1

2' MOW STRIP (OLI 1)

PAINT

BOOTH

(O

LI

1)1

4546 47

52 53

58 59 60

77 78

FEDERAL AVIATION

ADMINISTRATION CABLE IN THIS

AREA, APPROXIMATELY 24" DEEP.

THIS CABLE CANNOT BE SPLICED

IF CUT AND WOULD NEED

REPLACED ITS ENTIRE LENGTH.

PROPOSED

LANDSIDE

BITUMINOUS

PAVEMENT (OLI 2),

3,060 S.Y.

0 15' 30' 60' N

EXISTING PROPOSED LEGEND

BITUMINOUS PAVEMENT

PCC PAVEMENT

PCC SIDEWALK

WATER

ELECTRIC

GAS

COMMUNICATION

STORM

FENCE

STORM/SANITARY STRUCTURE

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

-B ay S pe ci al iz ed H an ga r M ad is on , W is co ns in

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

LDH

Engineering | Planning | Allied Services

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

PROPOSED PLAN

C-401

LDH

HLE

SS

ADDENDUM 2 06/08/20221

1. OLI - OPTIONAL LINE ITEM

2. THE POST AND PANEL WALL SECTION SHALL BE AS

INDICATED (10' TALL AND 12' WIDE PANELS) WITH DELEGATED

DESIGN TO BE CARRIED OUT BY THE CONTRACTOR UTILIZING

WIND LOADS/PRESSURES AS INDICATED ON SHEET S-001. A

MINIMUM 3" GAP SHALL BE CONSTRUCTED BETWEEN THE

PROPOSED BUILDING AND WALL.

ADDENDUM 3 06/14/20222

ADDENDUM 4 06/28/20223

AutoCAD SHX Text

SEE UTILITY PLAN FOR PROPOSED UTILITY INFORMATION

SS

EEEEE

EEE

E E

E E E E

E E E E E E

E

E

E

E

E

E

E

E E

E E

E E

E E

E

E

E

GGGGGGGGG

G

G G

G G

GG

G

G G

G

G

G

G

G

G

G G

G G

G

G

G

G

SAN SAN SAN SAN SAN SAN

SAN

SAN

SAN

SAN

SAN

SANSAN

SAN

SAN

SAN SAN

SAN

SA

N

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

T

T

T

T

TT

T

T

T

T

T

T

T

W W W W W W W W W W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W W

W

W

W

W W

W

W

W

W

WWWWW WV

WV

WVWV WV

WV

TEL

WV

TEL

WV

UT

UT

UT

WV

TEL

WV

UT

UT

UT

GV

GVGTST

WV

TEL

WV

WV

A/C A/C EL

SAN

AG

WV

AG

UT

UT

UT

SAN

SAN

SAN

GTST

WV

SS

WV

WV

WVWV

SAN

SAN

VENT

UT UT

A/C

UT

A/C

BORE

AG

SSSSSSSS

EXISTING 18" RCP TO REMAIN

SS

SS

W W

W W

W

W

W

W

W

W

W

W

W

W W W

SS

SSEX

IS

TI

N G

2"

R C

P

TO

R

EM

AI

N

W

W

EXISTING PCC

PAVEMENT

EXISTING

BITUMINOUS

PAVEMENT

EXISTING

BUILDING

EXISTING

BUILDINGS1a

S1

S3

S4

S5

S6c

S8

S7

S16

S13

INTRUSION DETECTION CABLES

AND GAP SENSORS TO BE

REMOVED AND REPLACED,

SPLICING WILL NOT BE ALLOWED.

WORK TO BE COORDINATED WITH

ADVANTOR.

PROPOSED COMMUNICATION LINE PER

BUILDING REQUIREMENTS, 235 L.F.

PROPOSED 3" DOMESTIC WATER

LINE PER BUILDING REQUIREMENTS,

49 L.F.

PROPOSED 12" DUCTILE IRON FIRE

PROTECTION SUPPLY PER BUILDING

REQUIREMENTS, 64 L.F.

PROPOSED 2" NATURAL GAS LINE PER

BUILDING REQUIREMENTS, 111 L.F.

PROPOSED GROUND ROD

(TYP.), 6 EACH

PROPOSED ELECTRICAL,

COORDINATE WITH MADISON

GAS AND ELECTRIC

PROPOSED HYDRANT AND

WATER CONNECTION

PROPOSED HYDRANT

AND WATER

CONNECTION

PROPOSED

HYDRANT AND

WATER CONNECTION

PROPOSED

HYDRANT AND

WATER CONNECTION

S6aS6b

S7a

S7b

S11

S12

S9a S9b S10a

S10b S10c

S10d

PROPOSED ELECTRICAL

TRANSFORMER,

COORDINATE WITH MADISON

GAS AND ELECTRIC

PROPOSED ELECTRICAL

TRANSFORMER,

COORDINATE WITH MADISON

GAS AND ELECTRIC T1a

T1c T2a

T3a

T3b

T4a

T4b

T5

T6a

T6b T7

T9

S2

S15

T8

S14

S10S9

PROPOSED ELECTRIC DROP BEAM

BARRIER (24' CLEAR OPENING) ACROSS

MITCHELL ST.

T1d

T1e

F-35 3-BAY

SPECIALIZED

HANGAR

S17

UPSTREAM JET FUEL

RESISTANT KNIFE GATE VALVE

L1b

L1a

S6d

L2

FEDERAL AVIATION

ADMINISTRATION CABLE IN THIS

AREA, APPROXIMATELY 24" DEEP.

THIS CABLE CANNOT BE SPLICED

IF CUT AND WOULD NEED

REPLACED ITS ENTIRE LENGTH.

ADDITIONAL PAVEMENT TO BE

REMOVED FOR UTILITY

REMOVAL OR INSTALLATION

SHALL BE REPLACED IN KIND.

T1b

"L" DRAINAGE

STRUCTURES ARE

ASSOCIATED WITH OLI

AWARD, SEE SCHEDULE

T4c

T4d

HYDRANT TO

BE 30" MAX

PROPOSED HYDRANT AND

WATER CONNECTION

FIRE DEPARTMENT

CONNECTION

POST INDICATOR VALVE

WITH TAMPER SWITCH

3/4" CONDUIT FOR TAMPER

SWITCH SIGNAL WIRING 2 - 1" CONDUITS FROM ELECTRICAL

ROOM TO DROP BEAM BARRIER

DOWNSTREAM JET FUEL

RESISTANT KNIFE GATE VALVE

0 15' 30' 60'

N

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

-B ay S pe ci al iz ed H an ga r M ad is on , W is co ns in

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

LDH

Engineering | Planning | Allied Services

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

UTILITY PLAN

C-601

LDH

HLE

EXISTING PROPOSED LEGEND

WATER

ELECTRIC

GAS

COMMUNICATION

STORM

SANITARY

STORM/SANITARY STRUCTURE

SS

SAN

ADDENDUM 3

1 06/14/2022

ADDENDUM 42 06/28/2022

AutoCAD SHX Text NOTES: 1. FOR ADDITIONAL INFORMATION SEE UTILITY DETAIL SHEETS. FOR ADDITIONAL INFORMATION SEE UTILITY DETAIL SHEETS. 2. ALL WORK PERFORMED SHALL BE IN CONFORMANCE WITH APPLICABLE UFCS, LOCAL UTILITY CODES AND WIDOT ALL WORK PERFORMED SHALL BE IN CONFORMANCE WITH APPLICABLE UFCS, LOCAL UTILITY CODES AND WIDOT REQUIREMENTS. 3. THE DROP BEAM CRASH BARRIER SHALL BE INCLUDED ON THE DEPARTMENT OF DEFENSE ANTI-RAM VEHICLE THE DROP BEAM CRASH BARRIER SHALL BE INCLUDED ON THE DEPARTMENT OF DEFENSE ANTI-RAM VEHICLE BARRIER LIST. THE SYSTEM SHALL BE ELECTRIC AND HAVE REMOTE AND KEY PAD ACCESS FOR TRAFFIC FROM THE EAST. FOR TRAFFIC ACCESS FROM THE WEST A DETECTOR LOOP SHOULD BE PROVIDED TO AUTOMATICALLY RAISE THE BARRIER ARM. 4. THE GAS LINE WILL NEED TO ACCOMMODATE 5 PSI PRESSURE AND 5,808 MBH LOAD. A 5M ROTARY METER PER THE GAS LINE WILL NEED TO ACCOMMODATE 5 PSI PRESSURE AND 5,808 MBH LOAD. A 5M ROTARY METER PER MG&E SPECIFICATION WILL BE REQUIRED. 5. THE KNIFE GATE VALVES SHALL BE JET FUEL RESISTANT. THE KNIFE GATE VALVES SHALL BE JET FUEL RESISTANT. 5.1. THE UPSTREAM VALVE SHALL HAVE A MANUAL SHUT OFF WITH POSITION MONITORING SYSTEM CONNECTED TO THE UPSTREAM VALVE SHALL HAVE A MANUAL SHUT OFF WITH POSITION MONITORING SYSTEM CONNECTED TO CONTAINMENT SYSTEM CONTROL PANEL. 5.2. THE DOWNSTREAM VALVE HALL HAVE A MANUAL, REMOTE SHUT OFF, TO BE ACTIVATED IN CASE OF FUEL SPILL, THE DOWNSTREAM VALVE HALL HAVE A MANUAL, REMOTE SHUT OFF, TO BE ACTIVATED IN CASE OF FUEL SPILL, WITH POSITION MONITORING SYSTEM CONNECTED TO CONTAINMENT SYSTEM CONTROL PANEL. 6. INSTALL, FLUSH AND TEST DOMESTIC WATER/FIRE SERVICE LINE PER NFPA 24. ALSO FLUSH PER NFPA 20 AT INSTALL, FLUSH AND TEST DOMESTIC WATER/FIRE SERVICE LINE PER NFPA 24. ALSO FLUSH PER NFPA 20 AT 3,000 GPM WITHOUT THE USE OF THE FIRE PUMP. 225 PSI TEST PRESSURE FLUSH AT 10 FPS PER NFPA 24. TRANSITION TO 12" WELDED STAINLESS LEAD IN AT 5' OUTSIDE FIRE PROTECTION ROOM. MINIMUM DEPTH OF BURY IS 82" BELOW GRADE 7. THE LOCATION, TYPE AND SIZE OF EXISTING UNDERGROUND AND/OR ABOVE GROUND UTILITIES ARE APPROXIMATE. THE LOCATION, TYPE AND SIZE OF EXISTING UNDERGROUND AND/OR ABOVE GROUND UTILITIES ARE APPROXIMATE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE RESPECTIVE UTILITIES TO BE LOCATED PRIOR TO CONSTRUCTION. IN THE EVENT OF AN UNEXPECTED UTILITY INTERFERENCE, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE UTILITY, THE ARCHITECT, AND THE OWNER'S REPRESENTATIVE. ANY DAMAGE TO A SERVICE OR MAIN SHALL BE RESTORED AT ONCE AT NO ADDITIONAL COST TO THE CONTRACT. 8. ANY CONFLICTS WITH PROPOSED CONSTRUCTION AND UTILITIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION ANY CONFLICTS WITH PROPOSED CONSTRUCTION AND UTILITIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. 9. WARNING TAPES SHALL BE PLACED ABOVE UTILITIES 1 FOOT BELOW GRADE. WARNING TAPES SHALL BE PLACED ABOVE UTILITIES 1 FOOT BELOW GRADE. 10. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS, UNLESS NOTED OTHERWISE, INCLUDING THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS, UNLESS NOTED OTHERWISE, INCLUDING PROVIDING ANY FINANCIAL SURETIES REQUIRED AS PART OF ANY PERMIT. 11. UTILITIES SHALL BE FURNISHED BY THE UTILITY PROVIDER, BUT INSTALLED BY THE GENERAL CONTRACTOR. UTILITIES SHALL BE FURNISHED BY THE UTILITY PROVIDER, BUT INSTALLED BY THE GENERAL CONTRACTOR. 12. EACH HYDRANT LOCATION SHALL HAVE 4 BOLLARDS, SEE DETAIL.EACH HYDRANT LOCATION SHALL HAVE 4 BOLLARDS, SEE DETAIL.

J

G

G

F

F

E

E

C

C

MK L

H

1'-10" 20'-6" 20'-8" 20'-6" 1'-10"

23'-10" 22'-0" 22'-6" 9'-0"

1'-10"

'-4

'-6

'-6

'-6

'-6

'-4

'-6

'-0

'-1

0"

'-4

/4

9' -0

BRACING

BR

AC

IN

G

BR

AC

IN

G

BRACING

BRACING

BRACING

BR

AC

IN

G

BR

AC

IN

G

MATCHLINE

'-9

/4

0'

-2

1' -1

0"

6'

-8

77'-4 3/4"

61'-8"

0'

-8

/4

1' -1

0"

2' -2

1' -1

0"

3/4"

1. PROVIDE BOTTOM FLANGE BRACES ON ALL ROOF GIRDERS AND

BEAMS . SPACE FLANGE BRACES AT 10'-0" OC TYP W/ ADD'L

LOCATIONS AS NOTED.

2. ALL SUSPENDED MECHANICAL, ELECTRICAL AND FIRE

PROTECTION PIPES OR EQUIPMENT SHALL BE SUPPORTED BY

BEAMS. PROVIDE KICKERS AS NEEDED. ATTACHMENT TO METAL

DECK FROM BELOW IS NOT ALLOWED.

3. LOCATION AND WEIGHTS OF MECHANICAL EQUIPMENT SHOWN ON

PLAN ARE BASIS OF DESIGN. VERIFY WITH MECHANICAL FOR

ADDITIONAL INFORMATION. GC TO COORDINATE FINAL LOCATION

AND SUPPORT REQUIREMENTS.

HIGH ROOF FRAMING PLAN NOTES

1 ROOF DECKING

1.5B 20GA GALV ROOF DECK (33 KSI MIN) ATTACHED

WITH 36/7 PATTERN OF 5/8" DIA PUDDLE WELDS AT

ALL SUPPORTS AND AT PERIMETER. PROVIDE #10

TEK LAP FASTENERS 20" OC.

2 NOT USED.

3 NOT USED.

4 RIGID RAIL FALL ARREST REFER TO .

5 NOT USED.

6 NOT USED

7 SUSPENDED FAN BELOW. 290 LBS ASSUMED WEIGHT.

8 PROVIDE ROOF FRAMING KICKERS AT 10'-0" MAX SPACING

TYPICAL.

HANGAR REFER AND

ADMIN REFER AND

C1 / SF502

C1 / SF502 C2 / SF502

C3 / SF502

MOMENT CONNX

A1 / S-002

MECHANICAL ROOF TOP UNIT OR MAKE UP AIR UNIT. REFER

TO MECHANICAL FOR UNIT SCHEDULING. GC TO COORD

FINAL LOCATION OF THE W8X18 SUPPLEMENTARY STEEL TO

SUPPORT UNIT CURBS ONCE FINAL UNITS HAVE BEEN

SELECTED. GC TO COORDINATE OPENINGS THRU ROOF OR

WALL AND PROVIDE ANGLE FRAMING FOR ROOF OPENING

AND COLD FORMED FRAMING AT WALL OPENINGS.

FALL ARREST ANCHOR PER DETAIL B3/S-002

FALL ARREST ANCHOR SIMILAR TO DETAIL B3/S-002.

L2-1/2x2-1/2 KICKER NOTED IN DETAIL B3/S-002 NOT

REQUIRED AT THESE LOCATIONS.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021N

N

PROJECT

KEYPLAN

A

PLAN TRUE

C :\U sers\nw c\D ocum ents\M y R evit\02700_S tru_N C hapm an9285M

.rvt

6/24/2022 5:13: 02 PM

HIGH ROOF FRAMING PLAN -

COMPOSITE

SF104

TJD

CTW

CTW

SCALE: 1/16" = 1'-0"

HIGH ROOF FRAMING PLAN - COMPOSITEA1

0 8' 16' 32'

1/16" = 1'-0"

1 ADDENDUM 1 04/22/2022

2 ADDENDUM 2 06/08/2022

3 ADDENDUM 4 06/28/2022

W

IS C O NS IN

P R

O F

E

S S I O N A L

E N G

I N E

E R

GENE O.

BROWN

E-47748

OKLAHOMA CITY

OK

M

M

K

K

L

L

D1

SF210

W30X116

W30X116

W30X116

W30X116

W30X116

W

X3

W

X3

W

X3

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

H S

S1 2X

X1

/4 H

S S1

2X

X1 /4

H S

S1 2X

X1

/4 H

S S1

2X

X1 /4

H S

S1 2X

X1

/4 H

S S1

2X

X1 /4

H S

S1 2X

X1

/4 H

S S1

2X

X1 /4

HSS12X12X1/4HSS12X12X1/4

W

X3

W

X3

W

X3

W16X36 W16X36

1'-10" 20'-6" 20'-8" 20'-6" 1'-10"

1' -1

0"

'-6

'-0

'-1 0"

'-4

/4

9'

-0

1' -1

0"

A1

SF401

SF502

D1

SF502

D2

B1

SF501

TYP

B1

SF501

TYP

1" DIA ROD

BRACING TYP

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W

X2

W16X36

HSS12X12X1/4

W

X3

W

X3

W

X3

H S

S1 2X

X1

/4

4'-2" 4'-1" 4'-1" 4'-1" 4'-1" 4'-2" 4'-1" 4'-2" 4'-1" 4'-2" 4'-1" 4'-1" 4'-1" 4'-1" 4'-2"

A1

SF402

W14X22

0"

SF502

C3

D1

SF503

D2

SF503

D3

SF503

AT GRID 6

SF502

C1

TYP

TYP

SF503

C4

SF503

C3

D4

SF503

W14X22

W14X22

H S

S1 2X

X1

/4

0'

-8

/4

61'-8"

DECK BRG

129'-8 1/2"

DECK BRG

133'-10 3/4"

'-0

" 10

10101010

1. PROVIDE BOTTOM FLANGE BRACES ON ALL ROOF GIRDERS AND

BEAMS . SPACE FLANGE BRACES AT 10'-0" OC TYP W/ ADD'L

LOCATIONS AS NOTED.

2. ALL SUSPENDED MECHANICAL, ELECTRICAL AND FIRE

PROTECTION PIPES OR EQUIPMENT SHALL BE SUPPORTED BY

BEAMS. PROVIDE KICKERS AS NEEDED. ATTACHMENT TO METAL

DECK FROM BELOW IS NOT ALLOWED.

3. LOCATION AND WEIGHTS OF MECHANICAL EQUIPMENT SHOWN ON

PLAN ARE BASIS OF DESIGN. VERIFY WITH MECHANICAL FOR

ADDITIONAL INFORMATION. GC TO COORDINATE FINAL LOCATION

AND SUPPORT REQUIREMENTS.

HIGH ROOF FRAMING PLAN NOTES

1 ROOF DECKING

1.5B 20GA GALV ROOF DECK (33 KSI MIN) ATTACHED

WITH 36/7 PATTERN OF 5/8" DIA PUDDLE WELDS AT

ALL SUPPORTS AND AT PERIMETER. PROVIDE #10

TEK LAP FASTENERS 20" OC.

2 NOT USED.

3 NOT USED.

4 RIGID RAIL FALL ARREST REFER TO .

5 NOT USED.

6 NOT USED

7 SUSPENDED FAN BELOW. 290 LBS ASSUMED WEIGHT.

8 PROVIDE ROOF FRAMING KICKERS AT 10'-0" MAX SPACING

TYPICAL.

HANGAR REFER AND

ADMIN REFER AND

C1 / SF502

C1 / SF502 C2 / SF502

C3 / SF502

MOMENT CONNX

A1 / S-002

MECHANICAL ROOF TOP UNIT OR MAKE UP AIR UNIT. REFER

TO MECHANICAL FOR UNIT SCHEDULING. GC TO COORD

FINAL LOCATION OF THE W8X18 SUPPLEMENTARY STEEL TO

SUPPORT UNIT CURBS ONCE FINAL UNITS HAVE BEEN

SELECTED. GC TO COORDINATE OPENINGS THRU ROOF OR

WALL AND PROVIDE ANGLE FRAMING FOR ROOF OPENING

AND COLD FORMED FRAMING AT WALL OPENINGS.

FALL ARREST ANCHOR PER DETAIL B3/S-002

FALL ARREST ANCHOR SIMILAR TO DETAIL B3/S-002.

L2-1/2x2-1/2 KICKER NOTED IN DETAIL B3/S-002 NOT

REQUIRED AT THESE LOCATIONS.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021N

N

PROJECT

KEYPLAN

A

PLAN TRUE

C :\U sers\nw c\D ocum ents\M y R evit\02700_S tru_N C hapm an9285M

.rvt

6/24/2022 5:13: 04 PM

HIGH ROOF FRAMING PLAN -

SECTOR ONE

SF105

TJD

GMR

GMR

SCALE: 1/8" = 1'-0"

HIGH ROOF FRAMING PLAN - SECTOR ONEA1

0 4' 8' 16'

1/8" = 1'-0"

1 ADDENDUM 1 04/22/2022

2 ADDENDUM 2 06/08/2022

3 ADDENDUM 4 06/28/2022

W

IS C O NS IN

P R

O F

E

S S I O N A L

E N G

I N E

E R

GENE O.

BROWN

E-47748

G

G

F

F

E

E

C

C

H

H

W

X1

W

X1

W16X36 W16X36

W14X22 W14X22

W

X1

W

X1

W16X26 W14X22

W16X26 W14X22

W16X26 W14X22

W16X26 W16X26

W16X26 W16X26

W14X22 W14X22

W14X22 W14X22

W14X22 W16X26

W14X22 W16X26

W16X26 W16X26

W14X22 W16X26

W14X22 W16X26

W16X26 W16X26

W16X26 W16X26

W16X26 W16X26

W16X26 W14X22

W16X26

W14X22

W16X26 W14X22

W16X26 W16X26

W14X22 W16X26

W14X22 W16X26

W16X26 W16X26

W14X22 W16X26

W14X22 W16X26

W16X26 W16X26

W16X26 W16X26

W14X22 W14X22

W14X22 W14X22

HSS12X12X1/4 HSS12X12X1/4

HSS12X12X1/4 HSS12X12X1/4

2'-2" 23'-10" 22'-0" 22'-6" 9'-0" 1'-10"

'-4

'-6

'-6

'-6

'-6

'-4

B1

SF401

B2

SF401

W

X3

W

X3

W

X3

W

X3

W

X3

W

X3

W16X26

W16X26

W16X26

W16X26

W14X30

W16X26 W14X22

W14X22

W14X22

W14X30

W16X26

W16X26

W16X26

W16X26

W14X30

W16X26

W16X26

W16X26

W16X26

W14X30

W16X26

W14X22

W14X22

W14X22

W14X30

W16X26

W16X26

W16X26

W16X26

W16X36 W16X36 W16X36 W16X26

HSS12X12X1/4

HSS12X12X1/4

W16X36

HSS12X12X1/4

H S

S1 2X

X1

/4 H

S S1

2X

X1 /4

H S

S1 2X

X1

/4 H

S S1

2X

X1 /4

H S

S1 2X

X1

/4 H

S S1

2X

X1 /4

HSS12X12X1/4

W16X26

2' -2

3'

-4

4' -3

4'

-3

4' -3

4'

-3

3' -0

5'

-0

5' -0

5'

-0

3' -6

4'

-6

4' -6

4'

-6

4' -0

4'

-0

4' -0

4'

-0

4' -6

4'

-6

4' -6

3'

-6

5' -0

5'

-0

5' -0

3'

-0

4' -3

4'

-3

4' -3

4'

-3

3' -4

1'

-1 0"

1" DIA ROD

BRACING TYPICAL

EF

150 LBS

EF

65 LBS

EF

65 LBS

EF

150 LBS

B1

SF402

B2

SF402

5"

W

X1

W

X1

SF502

C1

TYP

SF502

C1

TYP

77'-4"

6'

-8

D E

C K

BR

G

0'

-8

D E

C K

BR

G

3'

-1

3/ 4"

EHRU

3850 LBS

EHRU

3850 LBS

10'-0" 11

101010101010

1. PROVIDE BOTTOM FLANGE BRACES ON ALL ROOF GIRDERS AND

BEAMS . SPACE FLANGE BRACES AT 10'-0" OC TYP W/ ADD'L

LOCATIONS AS NOTED.

2. ALL SUSPENDED MECHANICAL, ELECTRICAL AND FIRE

PROTECTION PIPES OR EQUIPMENT SHALL BE SUPPORTED BY

BEAMS. PROVIDE KICKERS AS NEEDED. ATTACHMENT TO METAL

DECK FROM BELOW IS NOT ALLOWED.

3. LOCATION AND WEIGHTS OF MECHANICAL EQUIPMENT SHOWN ON

PLAN ARE BASIS OF DESIGN. VERIFY WITH MECHANICAL FOR

ADDITIONAL INFORMATION. GC TO COORDINATE FINAL LOCATION

AND SUPPORT REQUIREMENTS.

HIGH ROOF FRAMING PLAN NOTES

1 ROOF DECKING

1.5B 20GA GALV ROOF DECK (33 KSI MIN) ATTACHED

WITH 36/7 PATTERN OF 5/8" DIA PUDDLE WELDS AT

ALL SUPPORTS AND AT PERIMETER. PROVIDE #10

TEK LAP FASTENERS 20" OC.

2 NOT USED.

3 NOT USED.

4 RIGID RAIL FALL ARREST REFER TO .

5 NOT USED.

6 NOT USED

7 SUSPENDED FAN BELOW. 290 LBS ASSUMED WEIGHT.

8 PROVIDE ROOF FRAMING KICKERS AT 10'-0" MAX SPACING

TYPICAL.

HANGAR REFER AND

ADMIN REFER AND

C1 / SF502

C1 / SF502 C2 / SF502

C3 / SF502

MOMENT CONNX

A1 / S-002

MECHANICAL ROOF TOP UNIT OR MAKE UP AIR UNIT. REFER

TO MECHANICAL FOR UNIT SCHEDULING. GC TO COORD

FINAL LOCATION OF THE W8X18 SUPPLEMENTARY STEEL TO

SUPPORT UNIT CURBS ONCE FINAL UNITS HAVE BEEN

SELECTED. GC TO COORDINATE OPENINGS THRU ROOF OR

WALL AND PROVIDE ANGLE FRAMING FOR ROOF OPENING

AND COLD FORMED FRAMING AT WALL OPENINGS.

FALL ARREST ANCHOR PER DETAIL B3/S-002

FALL ARREST ANCHOR SIMILAR TO DETAIL B3/S-002.

L2-1/2x2-1/2 KICKER NOTED IN DETAIL B3/S-002 NOT

REQUIRED AT THESE LOCATIONS.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021N

N

PROJECT

KEYPLAN

A

PLAN TRUE

C :\U sers\nw c\D ocum ents\M y R evit\02700_S tru_N C hapm an9285M

.rvt

6/24/2022 5:13: 06 PM

HIGH ROOF FRAMING PLAN -

SECTOR TWO

SF106

TJD

GMR

GMR

SCALE: 1/8" = 1'-0"

HIGH ROOF FRAMING PLAN - SECTOR TWOA1

0 4' 8' 16'

1/8" = 1'-0"

1 ADDENDUM 1 04/22/2022

2 ADDENDUM 2 06/08/2022

3 ADDENDUM 4 06/28/2022

W

IS C O NS IN

P R

O F

E

S S I O N A L

E N G

I N E

E R

GENE O.

BROWN

E-47748

SF503

C3

GRID

GRID

3"x3/8" BENT PL w/

(1) 1" DIA A325-N

BOLT

8 1/2"x1'-4"x3/8" PL w/ (5)

3/4" DIA A325-N BOLTS

5/16 4

4"x3/8" FULL DEPTH

STIFFENER PL

1" DIA A36 STEEL ROD

1/4 1/4

3 SIDES

1/4 1/4

1/4

SF503

C4

GRID

GRID

5/16 4

TYP

3"x3/8" BENT PL w/ (1)

1" DIA A325-N BOLT

1" DIA A36 STEEL

ROD TYP

4"x3/8" FULL DEPTH

STIFFENER PL TYP

8 1/2"x1'-4"x3/8" PL w/ (5)

3/4" DIA A325-N BOLTS

3"x3/8" BENT PL w/ (1)

1" DIA A325-N BOLT

1/4 1/4

TYP

1/4

1/43 SIDES

TYP

SF503

B1

NOTE: BEAMS AND TOP FLANGE OF

GIRDER NOT SHOWN FOR CLARITY

GRID

GRID

5/16 4

TYP

5/16 4

TYP

1" DIA A36 STEEL

ROD TYP

3"x7"x3/8" PL w/ (1)

1" DIA A325-N BOLT

TYP

HSS5X2-1/2X1/4 w/ (4) 3/4"

DIA A325-N BOLTS TYP

8-1/2"x15"x3/8" PL

12"x3/8" BENT PL

GRID

GRID

SF503

B3

5/16 4

TYP

3/8" SHEAR PL BTWN TOP

STIFFENER AND CAP PL w/

(4) 3/4" DIA A325-N BOLTS

L4X4X3/8 w/ (3) 1" A325-N

BOLTS

1/2" FULL DEPTH

STIFFENERS

9"x3/8" BENT PL

3"x7"x3/8" PL w/ (1)

1" DIA A325-N BOLT

TYP

1" DIA A36 STEEL

ROD

1/4

SF503

A4

GRID

GRID

5/16 4

TYP

5"x3/8" FULL DEPTH

STIFFENER PL

8"x3/8" BENT PL

1" DIA A36 STEEL

ROD TYP

3"x7"x3/8" PL w/ (1)

1" DIA A325-N BOLT

TYP1/4

TYP

GRID

1" DIA A36 STEEL

ROD TYP

NOTE: FRONT FLANGE OF COLUMN

NOT SHOWN FOR CLARITY

3"x3/8" BENT PL w/ (1)

1" DIA A325-N BOLT

3"x3/8" BENT PL w/

(1) 1" DIA A325-N

BOLT

4"x3/8" FULL DEPTH

STIFFENER PL TYP

8 1/2"x1'-4"x3/8" PL w/ (5)

3/4" DIA A325-N BOLTS

TYP

1/2" FULL DEPTH

STIFFENER TYP

STRIP ONE SIDE OF

BEAM FLANGE AS

REQUIRED TYP

1/4

1/4 3 SIDES

TYP

GRID

1" DIA A36 STEEL

ROD

3"x3/8" BENT PL w/

(1) 1" DIA A325-N

BOLT

8 1/2"x1'-4"x3/8" PL w/

(5) 3/4" DIA A325-N

BOLTS

4"x3/8" FULL DEPTH

STIFFENER PL

3/8" CAP PL

1/4 1/4

3 SIDES

STRIP ONE SIDE OF

BEAM FLANGE AS

REQUIRED

NOTE: REFER D1 / SF503

GRID

1" DIA A36 STEEL

ROD TYP

HSS5X2-1/2X1/4 w/ (4)

3/4" DIA A325-N

BOLTS TYP

3"x7"x3/8" PL w/ (1)

1" DIA A325-N BOLT

TYP

8-1/2"x15"x3/8" PL

12"x3/8" BENT PL w/ (8) 3/4"

DIA A325-N BOLTS. (4)

BOLTS ALONG EACH LEG

12"x3/8" BENT PL w/ (8) 3/4"

DIA A325-N BOLTS. (4)

BOLTS ALONG EACH LEG

1/4" BENT PL1/4

2 1/4

2 3/41/4 1/4

TYP

3-1/2"x8-1/2x3/8" PL w/ (3) 3/4" DIA

A325-N BOLTS TYP

D3 / SF503NOTE: REFER

SF503

B2

GRID

GRID

5/16 4

TYP

5/16 4

TYP

1" DIA A36 STEEL

ROD TYP

3"x7"x3/8" PL w/ (1) 1"

DIA A325-N BOLT TYP

HSS5X2-1/2X1/4 w/ (4) 3/4"

DIA A325-N BOLTS

8-1/2"x15"x3/8" PL 12"x3/8" BENT PL

15"x3/8" BENT PL

L3X2-1/2X5/16 LLH

14-1/2"x4"x3/8" PL

3/4" DIA A325-N BOLT

GRID

1" DIA A36 STEEL

ROD TYP

1/4" BENT PL

2 1/4

2 3/4 3-1/2"x6"x3/8" PL w/

(2) 3/4" DIA A325-N

BOLTS

3-1/2"x8-1/2"x3/8" PL w/ (2) 3/4" DIA

A325-N BOLTS

4"x14-1/2"x3/8" PL

6" L3X2-1/2X5/16

LLH EACH SIDE

OF PLATE

6"x10"x3/8" PL

(2) 3/4" DIA

A325-N BOLTS

HSS5X2-1/2X1/4 w/ (4)

3/4" DIA A325-N

BOLTS

12"x3/8" BENT PL w/ (8) 3/4"

DIA A325-N BOLTS. (4)

BOLTS ALONG EACH LEG

12"x3/8" BENT PL w/ (8) 3/4"

DIA A325-N BOLTS. (4)

BOLTS ALONG EACH LEG

1/4

1/4 1/4

TYP

NOTE: REFER D4 / SF503

1" DIA A36 STEEL

ROD

5"x3/8" FULL DEPTH

STIFFENER PL

8"x3/8" BENT PL 3"x7"x3/8" PL w/ (1) 1"

DIA A325-N BOLT TYP

3-1/2"x6"x3/8" PL w/ (2)

3/4" DIA A325-N BOLTS

w/ LSL FOR ERECTION.

WELD SHAPE AFTER

LINE UP OF HANGAR

DOOR SUPPORT.

L4X4X1/2 w/ (2) 3/4"

DIA A325-N BOLTS

10"x14"x3/8" PL

5"x11"x3/8" PL w/ (3) 3/4"

DIA A325-N BOLTS

6"x10"x3/8" PL w/ (2) 3/4"

DIA A325-N BOLTS

1/4 6 1/4 6

1/4 1/4

HSS12X2

TO W12

1/2"X12"X1'-0" PL W/ (4)

3/4" DIA A325-N BOLT

HSS12X12 (REF ELEV)

COPE W12 FLANGE

1/4"X4"X6" CONT BENT PL1/4

HSS12X2

TO PL

(2) 3/4" DIA A325-N

BOLTS w/ LSL FOR

ERECTION. WELD

SHAPE AFTER

LINE UP OF

HANGAR DOOR

SUPPORT.

(4) 3/4" DIA A325-N

BOLTS w/ SLOPED

WASHERS. SHIM AS

REQUIRED

1/4 1/4

1/4

1/4

3 SIDES

1/4 3

3 SIDES

3"

3"

NOTE: ADDITIONAL CONNX

INFORMATION REFER TO

SECTION . GC TO

COORD ALIGMENT OF HANGAR

DOOR SUPPORT WITH MFG.

B1 / SF504

4" 3" 4"SF504

D3

NOTE: REFER C1 / SF503

1/4 1/4

1' -2

10"

GRID

1" DIA A36 STEEL

ROD

3/8" SHEAR PL BTWN TOP

STIFFENER AND CAP PL w/

(4) 3/4" DIA A325-N BOLTS

L4X4X3/8 w/ (3) 1" DIA

A325-N BOLTS

1/2" FULL DEPTH

STIFFENERS

9"x3/8" BENT PL (1)

1" DIA A325-N

BOLT

3"x7"x3/8" PL w/ (1)

1" DIA A325-N BOLT

TYP

3/8" CAP PL

1/4

STEEL COLUMN REFER

PLAN

NOTE: REFER C2 / SF503

BRACING ROD NOTES:

1. PROVIDE TURNBUCKLE FOR 1" DIA ROD NEAR MID-SPAN OF

ROD WHEN FACTORY LENGTH OF ROD IS SMALLER THAN

BRACING LENGTH REQUIRED. COORDINATE FINAL LOCATION OF

TURNBUCKLES WITH ARCHITECT PRIOR TO FABRICATION.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_S tru_N C hapm an9285M

.rvt

6/24/2022 5:13: 07 PM

FRAMING DETAILS

SF503

TJD

GMR

GMR

0 6" 1' 2'

1" = 1'-0"

SCALE: 1" = 1'-0"

SECTIOND1 SCALE: 1" = 1'-0"

SECTIOND2 SCALE: 1" = 1'-0"

SECTIOND3

SCALE: 1" = 1'-0"

SECTIONC2SCALE: 1" = 1'-0"

SECTIONC1 SCALE: 1" = 1'-0"

SECTIONC4SCALE: 1" = 1'-0"

SECTIONC3

SCALE: 1" = 1'-0"

SECTIONB1

SCALE: 1" = 1'-0"

SECTIOND4

SCALE: 1" = 1'-0"

SECTIONB2

SCALE: 1" = 1'-0"

SECTIONA4

SCALE: 1" = 1'-0"

SECTIONB3

1 ADDENDUM 4 06/28/2022

W

IS C O NS IN

P R

O F

E

S S I O N A L

E N G

I N E

E R

GENE O.

BROWN

E-47748

C

B

SF505

D4

SF505

D1

SF505

D4

SIM

SF505

D1

SIM

STEEL BEAM REFER

PLAN TYP

STEEL DECK BEYOND

REFER PLAN

1/4" BENT PL TYP

12" CMU WALL

REFER PLAN

STEEL BEAM

REFER PLAN

3/4" X 6" X 1'-0"

BEARING PLATE

W/ (2) #4 X 16" DBA'S

HIGH STRENGTH

NON-SHRINK GROUT

1/4

SHIM AS

REQ'D

GROUT SOLID

AROUND BEAMS

PROVIDE 2 CONT BOND BEAMS

BELOW ALL BEAM BEARINGS

1'-1 5/8"8"

116'-8 5/32"

1/4" CAP PL

A A.3

3/8" PL w/ (2) 3/4" DIA A325-N

BOLTS REFER 2 / S-006

3/8" PL w/ (2) 3/4" DIA

A325-N BOLTS

REFER 2 / S-006

STEEL DECK BEYOND

REFER PLAN

W10X12 TYP 3/8" PL w/ (2) 3/4" DIA

A325-N BOLTS

REFER 2 / S-006

STEEL BEAM

REFER PLAN

6-1/2"x11"x3/8" PL w/

(4) 3/4" DIA A325-N

BOLTS

(2) 6-1/2"x9"x3/8" PL w/ (6) 3/4" DIA

A325-N BOLTS

STEEL DECK REFER

PLAN

CMU WALL

END CONDITION

1/4

1/4

3/4" X 6" X 1'-0"

BEARING PLATE

W/ (2) #4 X 16" DBA'S

HIGH STRENGTH

NON-SHRINK GROUT

1/4

SHIM AS

REQ'D

1'-0"

PROVIDE 2 CONT

BOND BEAMS

BELOW ALL

BEAM BEARINGS

2 7/8"

EDGE OF DECK

A.3 6'-9"

STEEL DECK

REFER PLAN

C8X11.5

3/8" PL w/ (2) 3/4"

DIA A325-N BOLTS

TYP

3-1/2"x15"x3/8" PL w/ (5) 3/4" DIA

A325-N BOLTS

STEEL BEAM

REFER PLAN

L3X3X3/16

TOP RAIL

CONT TYP

1 1/2" 22 GA STEEL

DECK ATTACH TO

ANGLE POSTS W/

#12 SCREWS AT 12"

OC

(REFER

PLAN) FOR

LOCATION

AT 5'-0" O.C.

MAX

1/4" STIFFENER PLATE

AT EA ANGLE POST

1/4" CHECKERED

STEEL PLATE

L4x3x1/4 TOE KICK

3/16 3/16

3/16 2-12

TYP PL TO

BM

5/16

STEEL BEAM

(REFER PLAN)

PI

PE

/2 S

TD

L2 -1

/2 X2

-1 /2

X1 /4

6"

3/16

TYP

L2 1/2x2 1/2x1/4

3x6 1/2x1/4" PL w/ (2) 3/4" A325-N

BOLTS TYP

5/16

TYP

3/16

3 SIDES

TYP

5/16

3/16

REMOVABLE GUARDRAIL

REFER PLAN

3/16 3/16

3' -6

PIPE 2 1/2 STD

SLEEVE

1'-10" 2'-7 3/8" 5'-4 5/8" 1'-0"

132'-9 1/2"

H S

S4 X4

X5 /1

H S

S4 X4

X5 /1

W12X26

MC12X45

L4 X4X

1/2

1'-6" 7'-4"

A1

SF504

COMPACT 1.4" X 0.25" X 2" STAINLESS

STEEL EYEBOLT ANCHOR FOR FALL

ARREST ANCHOR POINT (OSHA

1910.140 AND OSHA 1926.502

APPROVED), ONE AT EACH HSS4X4

POST TO INTERIOR OF HANGAR BAY

H G

5' -0

5'

-0

4' -1

/2

3 SIDES TO

C12 TYP

W8X21

C12 L4x4x1/4x0'-9"

9"

C12

L4x4x1/4 w/ (2) 3/4"

DIA A325-N BOLTS

3" 6" 3"3 SIDES

TO HSS

3 SIDES

TO HSS

HSS12X2

TO W12

2'-7 3/8"

1/2"X12"X1'-0" PL W/ (4)

3/4" DIA A325-N BOLT

HSS12X2

(REF ELEV)

HSS12X12 (REF ELEV)

COPE W12 FLANGE

1/4"X4"X6" CONT BENT PL1/4

HSS12X2

TO PL

127'-10 1/2"

127'-1"

NOTE: FOR ADDITIONAL INFORMATION REFER A4 / SF503

OH

125'-11"

129'-5"

BOT OF W8

SF504

D3

TOS

SF504

C4

SF504

C3

122'-0 1/2"

C12

L4x4x1/4x0'-9"

3 SIDES

TO HSS

SF504

B1

MC12X45

1 1/2"

3/

4" T

YP

L6X4X3/8X1'-0" LLV

W/ (2) 3/4" DIA BOLT

(2) 3/4" DIA BOLT TC A

MACHT L6 BOLT

SPACING PROVIDE

SHIM PL

2"

SHIM AS REQ'D

STEEL BEAM REFER PLAN

3"x6-1/2"x1/4" PL w/ (2)

3/4" DIA A325-N BOLTS

TYP

1/4" CHECKERED

STEEL PL

L4X3X1/4 TOE

KICK TYP

L3X3X3/16 TOP

RAIL CONT.

CUT OUT STEEL DECK FOR

VERTICAL LIFT FABRIC

DOOR HOIST CLEARANCE

REFER MANUFACTURER

DOOR HOIST

PIPE 1-1/2" STD

w/ 2-1/2" STD

SLEEVE TYP

1'-7"

1' -7

4"x7"x3/8" PL w/ (2) 3/4"

DIA A325-N BOLTS

6"x10"x3/8" PL w/ (2) 3/4"

DIA A325-N BOLTS 1/4 6

1/4 6

1/4 1/4

4"x7"x3/8" PL w/ (2) 3/4"

DIA A325-N BOLTS

6"x10"x3/8" PL w/ (2) 3/4"

DIA A325-N BOLTS 1/4 6

1/4 6

1/4 1/4

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_S tru_N C hapm an9285M

.rvt

6/24/2022 5:13: 08 PM

FRAMING DETAILS

SF504

TJD

GMR

GMR

SCALE: 3/4" = 1'-0"

SECTIONA3 1' 3'2'0

3/4" = 1'-0"

0 6" 1' 2'

1" = 1'-0"

SCALE: 3/4" = 1'-0"

SECTIONB3

SCALE: 3/4" = 1'-0"

SECTIONB5

SCALE: 1 1/2" = 1'-0"

TYP MECHANICAL PLATFORM GUARDRAIL SECTIONA1

SCALE: 1" = 1'-0"

SECTIONB1

SCALE: 1" = 1'-0"

SECTIOND3

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1" = 1'-0"

SECTIOND4

SCALE: 1 1/2" = 1'-0"

SECTIONC4SCALE: 1 1/2" = 1'-0"

SECTIONC3

1 ADDENDUM 4 06/28/2022

W

IS C O NS IN

P R

O F

E

S S I O N A L

E N G

I N E

E R

GENE O.

BROWN

E-47748

PARTITION TYPE NOTES

A. STUD GAUGE IN PARTITION SCHEDULE IS A

MINIMUM.

B. STUD SPACING IN PARTITION SCHEDULE IS

MAXIMUM.

C. ALL GYPSUM BOARD SHALL BE 5/8" TYPE 'X' UNLESS

NOTED OTHERWISE OR REQUIRED FOR ACOUSTIC

ASSEMBLY.

D. PROVIDE CONTINUOUS 20 GAUGE DEFLECTION

TRACK (2 1/2" DEEP LEG TRACK) AND 20 GAUGE

UPPER HORIZONTAL SPACER BARS AT ALL

INTERIOR PARTITIONS EXTENDED TO DECK.

E. SUBSTITUTE 5/8" TYPE 'X' FIRE RESISTANT TILE

BACK BOARD AT ALL LOCATIONS SCHEDULED TO

RECEIVE WALL TILE.

F. ALL GYPSUM WALL BOARD SHALL BE CUT TIGHT TO

FIT AND SEALED COMPLETELY AIRTIGHT WITH

REQUIRED SEALANT FOR EITHER FIRE RATING OR

SOUND ATTENUATION AT ALL MEP PENETRATIONS

THRU INTERIOR PARTITIONS SCHEDULED TO DECK.

G. FILL ALL PERIMETER VOIDS AND HEAD OF WALL

METAL DECK FLUTES WITH FIRESAFING INSULATION

AT ALL FIRE RATED WALLS TO ACHIEVE COMPLETE

CLOSURE AND SEAL BOTH SIDES WITH ELASTIC

FIRESTOPPING SPRAY MASTIC.

H. ALL SOUND ATTENUATION BATTS SHALL BE

UNFACED, 2.5 PCF, INSTALLED CONTINUOUS

VERTICALLY, CUT TIGHT TO FIT AND FILL THE STUD

CAVITY.

I. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT

THE FOLLOWING LOCATIONS:

a. MECHANICAL ROOMS

b. PLUMBING WET WALLS AT JANITOR ROOMS AND

RESTROOMS

c. LOADING DOCK AND RELATED CORRIDOR

J. PROVIDE IMPACT RESISTANT GYPSUM BOARD AT

ALL CORRIDOR WALLS, UP TO 8'-0" AFF.

K. 'S' IN PARTITION SCHEDULE INDICATES SOUND

BATTS ARE TO BE PROVIDED BUT A MINIMUM STC IS

NOT SPECIFIED.

L. THE TERM "TO DECK" IN THE PARTITION SCHEDULE

REFERS TO THE ENTIRE WALL ASSEMBLY

CONTINUING TO THE DECK ABOVE. WHEN THIS IS

MARKED "NO" THEN THE WALL IS TO STOP 6" ABOVE

THE CEILING UNLESS NOTED OTHERWISE. OTHER

HEAD OF WALL CONDITIONS WILL BE NOTED IN THE

PARTITION SCHEDULE - TYPE COMMENTS OR ON

THE PLANS.

M. THE ASSEMBLY CODES IN THE TYPE COMMENTS

ARE USED AS A BASIS OF DESIGN AND NOT THE

ONLY METHOD OF ACHIEVING THE DESIRED

PERFORMANCE CRITERIA OF A WALL ASSEMBLY.

"A" SERIES - ACOUSTIC PARTITION

STC IS A PRIORITY. MAY OR MAY NOT NEED FIRE

RATING.

"B" SERIES - SCIF WALL

STC IS A PRIORITY. MAY OR MAY NOT NEED FIRE

RATING.

"C" SERIES - CHASE

"D" SERIES - DOUBLE STUD

STC OR WRAPPING AN ITEM IS PRIORITY. MAY OR

MAY NOT NEED FIRE RATING.

"F" SERIES - FURRING

"G" SERIES - GENERIC

"H" SERIES - HAT CHANNEL

"I" SERIES - INTERIOR PARTITION

NO FIRE RATING, NO STC RATING.

"M" SERIES - MASONRY - FIRE RATED

FIRE RATING IS PRIORITY. MAY OR MAY NOT NEED

STC.

"N" SERIES - MASONRY - NOT RATED

NO FIRE RATING. MAY OR MAY NOT NEED STC.

"P" SERIES - PARTIAL HEIGHT

NO FIRE RATING, NO STC RATING.

"R" SERIES - RATED INTERIOR PARTITION

"S" SERIES - SHAFT WALL

"U" SERIES - USER DEFINED

CREATE UNIQUE WALLS AS NEEDED.

"V" SERIES - VAULT WALL

TYPICALLY FOR CASINOS

"W" SERIES - FIRE WALL / AREA SEPARATION

PROTECTED ON BOTH SIDES OF AN EXPANSION

JOINT WHEN DOUBLE STUD.

"Z" SERIES - SOUND PARTITION WITH Z-CLIPS

STC IS A PRIORITY. MAY OR MAY NOT NEED FIRE

RATING.

WALL SERIES LEGEND

STANDARD PARTITION

BATT INSULATION

1-HOUR FIRE RATING

2-HOUR FIRE RATING

3-HOUR FIRE RATING

4-HOURS FIRE RATING

1-HOUR FIRE/SMOKE

CONCRETE MASONRY UNIT - HOLLOW

CONCRETE MASONRY UNIT - GROUT FILLED

CONCRETE MASONRY UNIT - SAND FILLED

DOUBLE STUD PARTITION

PARTITION TYPES LEGEND

A1*

"*" DENOTES WALL IS

TO DECK ABOVE

DENOTES GENERIC

SIZE OF STRUCTURAL

ELEMENT

WALL SERIES. SEE

LEGEND ON THIS

SHEET

1 HR. RATED PARTITION WITH 8" CMU

IBC TABLE 720.1, MATERIAL 3

2 HR. RATED PARTITION WITH 8" CMU

IBC TABLE 720.1, MATERIAL 3

1 HR. RATED PARTITION WITH 12" CMU

IBC TABLE 720.1, MATERIAL 3

A3

NON-RATED PARTITION AS SHOWN ABOVE

WITH UNFACED ACOUSTICAL BATTS AND

EXTENDING GYPSUM BOARD TO DECK

FINISH

FLOOR

5/8" GYP BD

SCHEDULED CLG

STEEL RUNNER

CHANNEL

1-5/8" STUDS

AT 16" OC

NON-RATED FURRING

PARTITION

C1

C6

NON-RATED FURRING

PARTITION WITH 6" STUDS AND

UNFACED ACOUSTICAL BATTS IN

LIEU OF 1-5/8" STUDS

CMU WALL

5/8" GYP BD

(BOTH SIDES)

FINISH

FLOOR

DECK

SLOTTED

DEFL TRACK

SCHEDULED CLG

STEEL RUNNER

CHANNEL

6" M

IN

BASE AS

SCHEDULED

BASE AS

SCHEDULED

3-5/8" STUDS

AT 16" OC

M8

M8A

M12C

STEEL

RUNNER

CHANNEL

A6

NON-RATED PARTITION AS SHOWN

ABOVE WITH 6" STUDS IN LIEU OF

3-5/8" STUDS

FINISH

FLOOR

DECK

SCHEDULED CLG

8" CMU

PROVIDE UL ASSEMBLY

HW-D-0042 TO DECK

BASE AS

SCHEDULED

6" M

IN

FINISHED FLOOR

FINISH

FLOOR

5/8" GYP BD

SCHEDULED CLG

STEEL RUNNER

CHANNEL

1-5/8" STUDS

AT 16" OC

NON-RATED FURRING

PARTITION

F1

F2

NON-RATED FURRING

PARTITION WITH 2-1/2" STUDS IN

LIEU OF 1-5/8" STUDS

6" M

IN

BASE AS

SCHEDULED

STEEL

RUNNER

CHANNEL

F3

NON-RATED FURRING

PARTITION WITH 3-5/8" STUDS IN

LIEU OF 1-5/8" STUDS

F6

NON-RATED FURRING

PARTITION WITH 6" STUDS IN

LIEU OF 1-5/8" STUDS

I3 NON-RATED PARTITION AS SHOWN ABOVE

5/8" GYP BD

(BOTH SIDES)

FINISH

FLOOR

DECK

SLOTTED

DEFL TRACK

SCHEDULED CLG

STEEL RUNNER

CHANNEL

BASE AS

SCHEDULED

3-5/8" STUDS

AT 16" OC

I6

NON-RATED PARTITION AS SHOWN

ABOVE WITH 6" STUDS IN LIEU OF

3-5/8" STUDS

6" M

IN

FINISHED FLOOR

NON RATED PARTITION WITH 8" CMU

IBC TABLE 720.1, MATERIAL 3

N8

FINISH

FLOOR

DECK

SCHEDULED CLG

8" CMU

PROVIDE UL ASSEMBLY

HW-D-0042 TO DECK

BASE AS

SCHEDULED

8" CMU

2HR RATED PARTITION WITH 8" CMU

IBC TABLE 720.1, MATERIAL 3 UP TO

11' - 4" AFF WITH 6" CH STUD ON TOP

WITH 2 LAYERS OF GYP BD ON

HANGAR SIDE

S6

FINISH

FLOOR

DECK

8" CMU

PROVIDE UL ASSEMBLY

HW-D-0042 TO DECK

BASE AS

SCHEDULED

SLOTTED

DEFLECTION

TRACK

FIRE SEALANT

5/8" GYP BD

(2 LAYERS)

1" SHAFT

LINER

6" CH STUD

10' - 0" AFF

T.O. CMU

REF STRUCTURAL

FOR DISTANCE

BELOW FINISH FLOOR

5/8" GYP BD

(BOTH SIDES)

FINISH

FLOOR

DECK

SLOTTED

DEFL TRACK

SCHEDULED CLG

STEEL RUNNER

CHANNEL

BASE AS

SCHEDULED

6" STUDS AT

16" OC

Z6

1HR RATED PARTITION WITH 6" CH

STUD, 1/2" RESILIENT CHANNEL,

5/8" ACOUSTIC GYP BD ON BOTH

SIDES - 1HR W/BATTS.

6" BATT

INSULATION

PROVIDE UL ASSEMBLY

HW-D-0042 TO DECK

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\gaz\D o cum ents\M y R evit\02700_Arch_G ZalabakZ5W

7D .rvt

6/28/2022 2:12: 22 PM

PARTITION TYPES

A-002

JBC

JRT/JBC

MP

INTERIOR PARTITION SCHEDULE

MARK

FIRE

RATING UL NO.

WALL

STC

SOUND

BATTS TYPE

TO

DECK

STUD

GAUGE

STUD

SPACING TYPE COMMENTS

A3 -- -- 45 Yes (A3) 3 5/8" STUDS, 5/8" ACOUSTIC GYP BD BOTH SIDES-0HR W/BATTS Yes 20 GA 16" OC NGC 2013005 A6 -- -- 45 Yes (A6) 6" STUDS, 5/8" GYP BD BOTH SIDES-0HR W/BATTS No 20 GA 16" OC NGC 2013023 C1 -- -- -- No (C1) 1 5/8" STUDS, 5/8" GYP BD ONE SIDE-0HR No 20 GA 16" OC -- C6 -- -- 55 Yes (C6) 6" STUDS, 5/8" GYP BD ONE SIDE-0HR W/BATTS Yes 20 GA 16" OC NGC 2013021 F1 -- -- -- No (F1) 1 5/8" STUDS, 5/8" GYP BD ONE SIDE-0HR No 20 GA 16" OC -- F2 -- -- -- No (F2) 2 1/2" STUDS, 5/8" GYP BD ONE SIDE-0HR No 20 GA 16" OC -- F3 -- -- -- No (F3) 3 5/8" STUDS, 5/8" GYP BD ONE SIDE-0HR No 20 GA 16" OC -- F6 -- -- -- No (F6) 6" STUDS, 5/8" GYP BD ONE SIDE-0HR No 20 GA 16" OC -- I3 -- -- -- No (I3) 3 5/8" STUDS, 5/8" GYP BD BOTH SIDES-0HR No 20 GA 16" OC -- I6 -- -- -- No (I6) 6" STUDS, 5/8" GYP BD BOTH SIDES-0HR Yes 20 GA 16" OC -- M8 1 U906 -- No (M8) 8" CMU BLOCK-1HR Yes -- -- --

M12C 1 U906 -- No (M12) 12" CMU BLOCK-1HR Yes -- -- -- N8 -- -- 55 No (N8) 8" CMU BLOCK, GROUT FILLED-0HR Yes -- -- GROUT FILLED S6 2 Yes

SCALE: NTS

PARTITION TAG LEGENDD1

SCALE: NTS

PARTITION TYPES1

1 ADDENDUM 3 06/14/2022

2 ADDENDUM 4 06/28/2022

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

C1 A-201

A1 A-202

A1 A-201

C1 A-202

A-301 D1

A-301 D1

A-301 C1

A-301 C1

A-301 A1

A-301 A1

A-302 B2

A-302 B2

A-302 D2

A-302 D2

1/ 2"

1'

-0

1/2" / 1'-0"

1/2" / 1'-0"

PRIMARY ROOF DRAIN

OVERFLOW ROOF DRAIN

LOW-SLOPE

MEMBRANE ROOF

PRIMARY ROOF

DRAIN

OVERFLOW

ROOF DRAIN

LOW-SLOPE

MEMBRANE

ROOF

PRIMARY

ROOF

DRAIN

OVERFLOW

ROOF

DRAIN

LOW-SLOPE

MEMBRANE ROOF

PRIMARY ROOF DRAIN

OVERFLOW ROOF DRAIN

ROOF

ACCESS

HATCH

FALL

PROTECTION

FALL

PROTECTION

SKYLIGHT

WALKWAY

PADS

WALKWAY

PADS

WALKWAY

PADS

WALKWAY

PADS

LOW-SLOPE

MEMBRANE

ROOF

MECH

EQUIPMENT

MECH

EQUIPMENT

MECH

EQUIPMENT

MECH

EQUIPMENT

ROOF

ACCESS

LADDER

ROOF

ACCESS

LADDER

MECH

EQUIPMENT

MECH EQUIPMENT

MECH EQUIPMENT

1/ 2"

1'

-0

GAS PIPE

ON ROOF

1/2" / 1'-0"

1/2" / 1'-0"

1/2" / 1'-0"

1/2" / 1'-0"

1/2" / 1'-0"

CRICKET

CRICKET

CRICKET

SUNSHADES

SUNSHADES

AWNING

AWNING

AWNING

AWNING

AWNING

AWNING

EQ EQ

25'-0"

42" GUARDRAIL

1' -0

CRICKET

CRICKET

CRICKET

BID OPTION 1

MECH

EQUIPMENT

(ON GROUND)

IG-501 A1

2 2

2 2

2 2

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021N

N

PROJECT

KEYPLAN

A

PLAN TRUE

C :\U sers\gaz\D o cum ents\M y R evit\02700_Arch_G ZalabakZ5W

7D .rvt

6/28/2022 2:12: 21 PM

ROOF PLAN

A-140

JMI

JRT/JBC

JBC

SCALE: 3/32" = 1'-0"

COMPOSITE ROOF PLANA1

8' 24'16'0

3/32" = 1'-0"

GENERAL NOTES

A. ALL ROOF SLOPES SHALL BE 1/2" PER 1' - 0" UNLESS

NOTED OTHERWISE.

B. ALL DRAINAGE CRICKETS SHALL BE 1/2" PER 1' - 0".

C. BASE ROOF INSULATION SHALL BE R-30 MINIMUM.

D. ALL PARAPET CAPS ARE PRE-FINISHED METAL.

E. LIGHTENING PROTECTION SHALL HAVE STRAP OVER

PARAPET AND FASTENED TO PLYWOOD.

1 ADDENDUM 2 06/08/2022

2 ADDENDUM 4 06/28/2022

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

OVERHEAD

COILING DOOR

OVERHEAD COILING

DOOR JAMB GUIDES

OVERHEAD COILING

DOOR HOOD

CMU BOND BEAM

RE: FLOOR PLANS

CMU

OVERHEAD COILING

DOOR JAMB GUIDES

STEEL ANGLE

BY MANF.

OVERHEAD

COILING DOOR

CMU

R E:

F

LO

O R

P

LA

N

C M

U

EXPANSION

ANCHOR BOLT

CONT SEALANT, BOTH SIDES

DOUBLE JAMB STUDS TYP

AT ALL JAMBS (CLIP

TOGETHER AT 12" OC VERT)

ALUMINUM

WINDOW

SYSTEM

R E:

F

LO

O R

P

LA

N S

PA

R

TI

TI

O N

2" 4 1/2"

1/

2"

6"

3/8" 2"

HEAD/SILL

INSULATED

OUTSIDE GLAZING

JAMB

INSULATED

OUTSIDE GLAZING

HEAD/JAMB/SILL

INT 1/4" GLZ

SHIM AS REQUIRED

@ EXT: LOW EXPANSION FOAM FILL

IN PERIMETER FRAME JOINT CAVITY

@INT: SHIM AS REQUIRED

FABRIC HANGAR DOOR

MFR

EXTRUSION

VERTICAL

INSULATED METAL

WALL PANEL

INSULTED METAL

SOFFIT PANEL

DOOR CLEAR HEIGHT

121'-8 1/2"

6'

2"

1' -7

2" INSULATED METAL

PANEL SOFFIT

2" INSULATED METAL

WALL PANEL

STRUCTURAL FABRIC

DOOR SUPPORT

SHEET METAL TRIM

4'-7"

CATWALK GUARDRAIL

DOOR HOIST ENCLOSURE

1'-7" X 1'-7" X 4'-7"

FABRIC DOOR FLOOR SEAL

FABRIC DOOR BOTTOM BEAM

FABRIC DOOR

INTERMEDIATE BEAMS

FABRIC DOOR BEAM CLAMPS

8" 8" 8"

COLD-FORMED METAL FRAMING

TO SUPPORT METAL PANEL SOFFIT

GROUND FLOOR

100'-0"

PAVING (REFER TO CIVIL)

SLAB OF GRADE

WITH RIDGE AT

CENTER OF DOOR

FABRIC HANGAR DOOR

FLOOR SEAL WITH

SAFETY EDGE

1/4" / 1'-0"1/4" / 1'-0"

SCHEDULED WINDOW

SHIM & CAULK

SCHEDULED FLOOR

CONC. FLOOR SLAB

SHIM & CAULK

SCHEDULED WINDOW

GYP BD

PLYWOOD BLOCKING

6" CFMF W/ SOUND BATT

INSUL.

6" CFMF W/ SOUND

BATT INSUL.

SCHEDULED WINDOW

6" CFMF BOX BEAM

PLYWOOD BLOCKING

GYP BD

SHIM AND SEALANT

5/8" GYP BD

(2 LAYERS)

FIRE SEALANT

6" CH STUD

6" CHANNEL

BEAM

ANGLE

8" BOND BEAM

1" SHAFT

LINER

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\gaz\D o cum ents\M y R evit\02700_Arch_G ZalabakZ5W

7D .rvt

6/28/2022 2:12: 31 PM

DETAILS

A-501

JMI

BDR

JBC

SCALE: 3" = 1'-0"

HEAD DETAILD2

SCALE: 3" = 1'-0"

JAMB DETAILD3

SCALE: 3" = 1'-0"

NOT USEDD1

SCALE: 3" = 1'-0"

STOREFRONT, HEAD, JAMB, SILL DETAILSA3

SCALE: 1 1/2" = 1'-0"

HEAD DETAILB1

SCALE: 1 1/2" = 1'-0"

SILL DETAILA1 3" 9"6"0

3" = 1'-0"

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1 1/2" = 1'-0"

WINDOW SILL DETAILB3 SCALE: 1 1/2" = 1'-0"

WINDOW JAMB DETAILB4 SCALE: 1 1/2" = 1'-0"

WINDOW HEAD DETAILB5

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA5

1 ADDENDUM 2 06/08/2022

2 ADDENDUM 3 06/14/2022

3 ADDENDUM 4 06/28/2022

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

GROUND FLOOR

100'-0"

SCHEDULED GLAZING

SHIM AND SEALANT

BACKER ROD

AND SEALANT

PAVING, REFER

TO CIVIL

SLAB ON GRADE

ROOF FRAMING

115'-0"

STEEL

STRUCTURE

ROOF

MEMBRANE

6" ROOF

INSULATION

(R-30)

STEEL DECK

5/8" SHEATHING ON

EA SIDE

ROOF PROTECTION

BOARD

DEFLECTION TRACK

8" CFMF

A.3

SHIM TRACK

13 ROOF

MEMBRANE

6" ROOF

INSULATION

(R-30)

STEEL

DECK

2 LAYERS 5/8"

GYP. BD.

CH STUD

STEEL BEAM

DEFLECTION

TRACK

1" SHAFT LINER

BATT

INSULATION

(R-25)

ROOF

PROTECTION

BOARD

STEEL COLUMN

+/- 9 1/4" +/- 9 1/4"

GROUND FLOOR

100'-0"

ONE HOUR

RATED 8"

CMU

1' -4

SLAB ON

GRADE

FOOTING

8" 8"

SCHEDULED

BASE

8" CMU BOND BEAM,

RE: STRUCTURAL

GROUND FLOOR

100'-0"

ONE HOUR

RATED 12"

CMU WALL

5/8" GYPSUM

WALLBOARD

8" BATT

INSULATION

(R-25)

8" CFMF

SLAB ON GRADE

PORCELAIN

WALL TILE

8" TRACK

FOOTING

SCHEDULED BASE

C

ADMIN ROOF

116'-8"

ROOF

MEMBRANE

6" ROOF

INSULATION

(R-30)

STEEL DECK

12" CMU

8" BATT

INSULATION

(R-25)

8" CFMF

5/8" GYPSUM

WALLBOARD

4" VERTICAL

INSULATED METAL

PANEL (R-32)

ROOF

PROTECTION

BOARD

8" TRACK

TURN MEMBRANE

UP PANEL (SIM

D5/AE-502)

CFMF

INFILL AT

16" O.C.

FASTNER

EXPANSION

JOINT (EJ-2)

FLEXIBLE

FLASHING

FT WOOD

BLOCKING

STEEL ANGLE

STEEL

STRUCTURE

STEEL CHANNEL

VAPOR

BARRIER

1'-2"

10"

8" CMU GROUT

FILLED

CAST STONE

COPING

4" SPLIT

FACED CMU

4" CAVITY WALL

INSULATION (R-15)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

BACKER ROD

& SEALANT

STEEL CHANNEL

STEEL COLUMN

L3X3X3/16 STEEL

ANGLE CONT GALV

W/ DIA POST

INSTALLED

ANCHOR AT 24" OC

BACKER ROD

& SEALANT

PERIMETER

ANGLE

1"

PREFINSIHED

METAL FLASHING

GROUND FLOOR

100'-0"

ONE HOUR

RATED 8" CMU

WALL

4" CAVITY WALL

INSULATION

(R-15)

4" CMU SPLIT-FACED

FLUID APPLIED

AIR BARRIER

PRE-FINISHED

METAL FLASHING

WEEP

CONCRETE CURB

MORTAR NET

PAVEMENT

(REFER CIVIL)

REFER PLANS

BACKER ROD &

SEALANT

TRANSLUCENT

PANELS (R-12.5)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

STEEL CHANNEL

INSTALL PANELS

PER MFG SPECIFICATIONS

STEEL COLUMN

STEEL ANGLE

TRANSLUCENT

PANELS

(R-12.5)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

STEEL CHANNEL

STEEL COLUMN

INSTALL PANELS

PER MFG SPECIFICATIONS

STEEL ANGLE

1'-4" 10"

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

EXTEND ROOF

MEMBRANE UP &

OVER PARAPET

6" ROOF

INSULATION

(R-30)

STEEL DECK

ROOF

PROTECTION

BOARD

PRE-FINISHED

METAL PARAPET

CAP

WOOD

BLOCKING

TAPERED

INSULATION

8" BATT

INSULATION

(R-25)

STEEL

STRUCTURE

EXTERIOR

SHEATHING

FT WOOD

BLOCKING

STEEL ANGLE

2'-2"

SLOPE

BATT

INSULATION

(R-25)

EXTERIOR

GYPSUM

WALLBOARD

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

8" CFMF

EXTERIOR

SHEATHING

PRE-FINISHED

METAL

PARAPET CAP

EXTEND ROOF

MEMBRANE UP &

OVER PARAPET

WOOD

BLOCKING

6" ROOF

INSULATION

(R-30)

STEEL DECK

VAPOR BARRIER

ROOF

PROTECTION

BOARD

T.O. PARAPET

119'-4"

STEEL

STRUCTURE

COMPRESSION

BAR

FT WOOD

BLOCKING

STEEL ANGLE

SLOPE

1'-2" TYP.

GROUND FLOOR

100'-0"

EDGE OF SLAB

CAVITY WALL

INSULATION (R-15)

8" CFMF

BATT INSULATION (R-25)

5/8" GYP. BD.

EXTERIOR SHEATHING

FLUID APPLIED AIR

BARRIERWEEP

4" CMU

SPLIT FACE

SCHEDULED BASE

8" TRACK

8"

CAST STONE

COPING

PRE-FINISHED

METAL FLASHING

PAVEMENT

(REFER CIVIL)

GROUT FILL

GRAVEL FILL

MORTAR NET

MASONRY

WALL TIES

PREFINSIHED

METAL FLASHING

BACKER ROD

& SEALANT

REFER PLANS

CONT L3X3X3/16 GALV

ANGLE ATTACHED

TO TO STUDS WITH 2 #10

TEK SCREWS AT 16" O.C.

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

BOND BREAKER

FINISHED SOFFIT

109'-0"

ROOF MEMBRANE OVER

PROTECTION BOARD

EDGE ANGLE

6" ROOF TAPERED

INSULATION (R-30)

PRE-FINISHED

METAL DRIP EDGE

HORIZONTAL

INSULATED METAL

PANELS - COLOR #2

MEMBRANE

FLASHING

CONTINUOUS

CLEAT

TREATED WOOD

BLOCKING

STEEL

CHANNEL

EXTERIOR

SHEATHING ON

CFMF

EXTERIOR

SHEATHING ON

CFMF

INSULATED METAL

PANELS - COLOR #2

M

IN

8"

COORDINATE

THROUGH WALL

FLASHING DETAIL

WITH PANEL MFR

PRE-FINISHED

METAL REGLET

AND COUNTER

FLASHING

ROOFING

MEMBRANE

TURNED UP

METAL PANEL

9'-1 1/4"

MFR

EXTRUSION BACKER ROD

& SEALANT,

EA. SIDECURTAINWALL

SYSTEM

CFMF BOX

BEAM

STEEL

STRUCTURE

WOOD

BLOCKING

CEILING AS

SCHED.

5/8" GYP BD

8" CFMF

BATT

INSULATION

SHIM AS

REQUIRED

TREATED WOOD

BLOCKING

STEEL DECK

SLOPE

T.O. PARAPET

119'-4"

4' -0

COMPRESSION

BAR

PRE-FINISHED METAL

PARAPET CAP

WOOD BLOCKING

VAPOR

RETARDER

6" ROOF

INSULATION (R-30)

ROOF PROTECTION

BOARD

EXTEND ROOF

MEMBRANE UP &

OVER PARAPET

STEEL DECK

ONE HOUR

RATED 8" CMU

8" CFMF

EXTERIOR

SHEATHING

BATT INSULATION

(R-25)

VAPOR

BARRIER

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

STEEL ANGLE

SLOPE

J

METAL

DECK

6" ROOF

INSULATION

R(30)

ROOFING

MEMBRANE

OVER ROOF

PROTECTION

BOARD

WOOD

BLOCKING

EXPANSION

JOINT (EJ-1)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

ROOF MEMBRANE

COUNTER-

FLASHING

AIR BARRIER

STEEL

COLUMN

8" CMU

3-5/8" CFMF @

16" OC

VERTICALLY

COUNTER-

FLASHING

10"

EDGE ANGLE

SHEET METAL

CLOSURE

ATTACHED ONLY

TO CMU

FILL CAVITY

WITH BATT

INSULATION

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\gaz\D o cum ents\M y R evit\02700_Arch_G ZalabakZ5W

7D .rvt

6/28/2022 2:12: 25 PM

DETAILS

A-502

JMI

JRT/JBC

JBC

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILC3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB2

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA2

SCALE: 1 1/2" = 1'-0"

SECTION DETAILC2

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD2

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB1

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA1

SCALE: 1 1/2" = 1'-0"

TRANSLUCENT PANEL SILL DETAILC1B

SCALE: 1 1/2" = 1'-0"

TRANSLUCENT PANEL HEAD/JAMB DETAILC1A

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD1

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD5

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB5

SCALE: 1" = 1'-0"

SECTION DETAILA5

0 6" 1' 2'

1" = 1'-0"

1 ADDENDUM 4 06/28/2022

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

8" CFMF

EXTERIOR INSULATION

AND FINISH SYSTEM

(E.I.F.S.) (R-16)

FLUID-APPLIED

MEMBRANE AIR

BARRIER

MANUFACTURED

ALUM CANOPY

1/2" EXTERIOR

GYPSUM SHEATHING

HANGAR ROD

8" CFMF BOX

BEAM

6'-0"

BACKER ROD AND

SEALANT

110' - 4"

BO CANOPY

BENT PLATE PAINTED TO

MATCH EIFS COLOR

8" CFMF BOX

BEAM

5/8" GYP BD

CFMF

1/2" EXTERIOR

GYPSUM

SHEATHING

EXTERIOR INSULATION

AND FINISH SYSTEM

(E.I.F.S.) (R-16)

BACKER ROD &

SEALANT

FLUID-APPLIED

MEMBRANE VAPOR

BARRIER

3/4"

1/2" EXTERIOR

GYPSUM SHEATHING

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

FLUID-APPLIED

MEMBRANE VAPOR

BARRIER

NOTE: REVEAL DIMENSIONS ARE MEASURED TO

THE CENTERLINE OF THE REVEAL

3/4"

CL

3/ 4"

3/ 4"

3/ 4"

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\gaz\D o cum ents\M y R evit\02700_Arch_G ZalabakZ5W

7D .rvt

6/28/2022 2:12: 31 PM

DETAILS

A-503

JBC

GAZ

GAZ

SCALE: 1 1/2" = 1'-0"

PRE-ENGINEERED METAL CANOPYA1

SCALE: 1 1/2" = 1'-0"

EIFS CONTROL JOINT DETAILC1

SCALE: 1 1/2" = 1'-0"

EIFS REVEAL JOINTB1

6" 1'-6"1'0

1 1/2" = 1'-0"

1 ADDENDUM 4 06/28/2022

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

PAINT/SAND/MIX

ELEC

DIRTY VEST

WASH BAY

128142

133 140

139A

137A

134A

131A

144B* 144C*

DIRTY ROOM

144.2

CLEAN ROOM

144.1

144.1*

144.2*

AIR SHOWER

144.3

EXTENTS OF PAINT BOOTH

144.2B*

PAINT/SAND/MIX

1.A.01 TYPE 3

ELEC

DIRTY VEST

WASH BAY

DIRTY ROOM

144.2

1.A.04 TYPE 2

1.A.03 TYPE 2

CLEAN ROOM

144.1

1.A.05 TYPE 6

1.A.06 TYPE 2

1.A.07 TYPE 12

1.A.08 TYPE 2

AIR SHOWER

144.3

RF3 RF1

EQ11

EQ12

EXTENTS OF PAINT BOOTH

GENERAL NOTES

A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD

BE CONSIDERED AS COMPLEMENTARY TO THE

CONSTRUCTION DOCUMENTS AS A WHOLE. ANY

QUESTIONS OR CONFLICTS SHOULD BE BROUGHT

TO THE ARCHITECTS ATTENTION.

B. PROVIDE A SMOOTH TRANSITION BETWEEN

DIFFERENT FLOOR MATERIALS.

C. REFER TO A-602 FINISH MATERIALS SCHEDULE FOR

MATERIAL MANUFACTURER AND COLOR.

D. REFER TO COMPOSITE INTERIOR SIGNAGE PLAN

B1/A-702 FOR FURNITURE, FIXTURES AND

EQUIPMENT.

INTERIOR FINISH

ABBREVIATION LEGEND

ACT ACOUSTICAL CEILING TILE

AFF ABOVE FINISHED FLOOR

CPT CARPET TILE

GYP BD GYPSUM WALL BOARD

ESD ELECTROSTATIC DISSIPATIVE TILE

EXP EXPOSED

FRP FIBERGLASS REINFORCED PLASTIC

FRRF FUEL RESTISTIVE RESINOUS FLOORING

GT GLASS…