This document provides details for an unrestricted invitation for bid for construction services. The 115th Fighter Wing at Dane County Regional Airport intends to issue an IFB for award of a single firm fixed-price contract to construct a new three-bay hangar facility compatible with the F-35 mission, including demolishing an existing building. Scope of work includes demolishing Building 414 and constructing a new 31,000 square foot three bay hangar with administrative and shop spaces, along with aircraft air conditioning, power, fire suppression, and HVAC systems. The contract duration is 550 days from notice to proceed. The NAICS code is 236220 with a size standard of $39.5 million. The estimated value is between $25-100 million. Award will be made to the responsive and responsible lowest bidder. The solicitation allows for two options and requires brand name justification. The pre-bid conference will be held on-site at Truax Field, and bids are to be submitted through the SAM website.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 THREE BAY SPECIALIZED HANGAR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ANG/WI - F-35: 3-Bay Specialized Hangar 20202700F353BAY Addendum No. 03 14 June 2022
SECTION 10 51 13
METAL LOCKERS
05/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A1008/A1008M (2020) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
ASTM B456 (2017) Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
FS AA-L-00486 (Rev J) Lockers, Clothing, Steel
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Types ; G
Location ; G
Installation
Numbering system
SD-03 Product Data
Material
Locking Devices
Handles
SECTION 10 51 13 Page 1
Finish
Locker components
Assembly instructions
SD-04 Samples
Color chips ; G
1.3 DELIVERY, HANDLING, AND STORAGE
Deliver lockers and associated materials in their original packages, containers, or bundles bearing the manufacturer's name and the name of the material. Protect from weather, soil, and damage during delivery, storage, and construction.
1.4 FIELD MEASUREMENTS
To ensure proper fits, make field measurements prior to the preparation of drawings and fabrication. Verify correct location
1.5 QUALITY ASSURANCE
1.5.1 Color Chips
Provide a minimum of three color chips, not less than 3 inches square, of each color indicated.
Government may request performance-characteristic tests on assembled lockers. Tests and results must conform to FS AA-L-00486 . Lockers not conforming will be rejected.
PART 2 PRODUCTS
2.1 TYPES
Locker must have the following type and size in the location and quantities indicated. Locker finish colors will be as scheduled.
2.1.1 Single-tier Lockers
Single-tier lockers must be as follows:
Type A14: Single-tier locker 12 inches wide, 18 inches deep, and 72 inches high, attached to 6-inch high closed base
2.1.2 Double-Tier
Double-tier lockers must be as follows:
Type A20: Double-tier locker 1 2 inches wide, 1 8 inches deep, and 72 inches high, attached to 6-inch high legs
SECTION 10 51 13 Page 2
2.2 MATERIAL
2.2.1 Steel Sheet
ASTM A1008/A1008M , commercial quality, minimized spangle material.
Prepare material surfaces for powder coat finishing in accordance with FS AA-L-00486 . Minimum uncoated sheet thickness as specified .
2.2.2 Chromium Coating
Nickel and chromium electrodeposited on the specified base metal. Conform to ASTM B456, SC-3, as applicable to the base metal.
2.2.3 Finish
powder coat
2.2.3.1 Color
As selected.
2.3 COMPONENTS
2.3.1 Built-In Locks
FS AA-L-00486 . Provide locking devices as a padlock eye in the door latching mechanism.
Built-in locks are not required.
2.3.2 Coat Hooks
FS AA-L-00486 , chromium and zinc plated.
2.3.3 Hanger Rods
FS AA-L-00486 .
2.3.4 Door Handles
FS AA-L-00486 . Provide zinc alloy or steel handles with a chromium coating.
2.3.5 Doors
FS AA-L-00486 , not less than 0.0598 inch thick steel sheet.
2.3.5.1 Hinges
In addition to the requirements of FS AA-L-00486 , provide 5-knuckle hinges, minimum 2 inches high. Fabricate knuckle hinges from not less than
0.0787 inch thick steel sheet. A full height piano hinge may be provided
SECTION 10 51 13 Page 3 if standard with the manufacturer. Weld or bolt hinges to the door frame. Weld, bolt, or rivet hinges to the door.
2.3.5.2 Latching Mechanisms
FS AA-L-00486 .
2.3.6 Latch Strikes
FS AA-L-00486 . Fabricate from not less than 0.0787 inch thick steel sheet, except latch strike may be continuous from top to bottom and fabricated as part of the door framing.
2.3.7 Silencers
FS AA-L-00486 .
2.3.8 Back and Side Panels, Tops, and Bottoms
FS AA-L-00486 , not less than 0.0474 inch thick steel sheet.
2.3.9 Sloping Locker Tops
Provide sloping locker tops in addition to the locker-section flat tops.
Sloping tops must be continuous in length. Provide fillers or closures at the exposed end of sloping tops. Fabricate sloping tops from not less than 0.0478-inch thick steel sheet.
2.3.10 Shelves
FS AA-L-00486 . Fabricate from not less than 0.0598 inch thick steel sheet.
2.3.11 Base Panels
FS AA-L-00486 .
2.3.12 Legs
2.3.13 Number Plates
FS AA-L-00486 . Aluminum . Provide consecutive numbers .
2.3.13.1 LOCKER BENCHES
LOCKER BENCHES:
a. Provide bench units with overall assembly height of 17-1/2 inches.
b. Bench Tops: Manufacturer's standard one-piece units, with rounded corners and edges.
1. Size: Minimum 9-1/2 inches wide by 1-1/4 inches thick except provide 20 to 24 inch wide tops where accessible benches are indicated.
2. Laminated clear maple with one coat of clear sealer on all surfaces and one coat of clear lacquer on top and sides.122
c. Fixed-Bench Pedestals: Manufacturer's standard supports, with predrilled fastener holes for attaching bench top and anchoring to floor, complete
SECTION 10 51 13 Page 4 with fasteners and anchors, and as follows:
1. Tubular Steel: 1-1/4 inch diameter steel tubing, with 0.1265 inch thick steel flanges welded at top and base; with powder coat finish; anchored with exposed fasteners.
a) Color: Match metal lockers.Text
2.3.14 Fastening Devices
Provide bolts, nuts, and rivets as specified in FS AA-L-00486 .
PART 3 EXECUTION
3.1 ASSEMBLY AND INSTALLATION
Assemble lockers according to the locker manufacturer's instructions.
Align lockers horizontally and vertically. Secure lockers to wall and base with screws as indicated. Bolt adjacent lockers together. Adjust doors to operate freely without sticking or binding and to ensure they close tightly.
3.2 NUMBERING SYSTEM
Install number plates on lockers consecutively with odd numbers on top and even numbers on bottom .
3.3 FIELD QUALITY CONTROL
3.3.1 Testing
Government may request performance-characteristic tests on assembled lockers in accordance with FS AA-L-00486 . Lockers not conforming will be rejected.
3.3.2 Repairing
Remove and replace damaged and unacceptable portions of completed work with new.
3.3.3 Cleaning
Clean surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner. Remove equipment, surplus materials, and rubbish from the site.
-- End of Section --