Slip-Metal-Skirt-Flashing.pdf

PDF 126 KB Posted

Attached to
ROOFING AT ALLENDALE ELEMENTARY SCHOOL AND ROGERS BUILDING
Solicitation number
RFP MNA 260000002642 1
Issued by
Wayne County, Michigan

About this file

This is a technical drawing specification document for roofing work that outlines the installation requirements for slip-metal-skirt flashing in conjunction with built-up roofing (BUR) systems. The drawing (Drawing No. 27, dated 2023) provides detailed specifications for the construction and installation of hot/cold slip metal skirt flashing designed to be adhered to the roof deck. The project involves the installation of new metal counterflashing with new grommeted fasteners spaced 8 inches on center, along with two-ply stripping sheet adhesive applied to a specified elastomeric base. The specification includes provisions for existing metal gravel surfacing and a specified cant sheet, with all components to be installed per the detailed specifications referenced in the drawing documentation.

The drawing indicates that all materials and installation methods are to be completed according to specifications, with the existing roof structure to be preserved during the work. The document provides a non-to-scale (NTS) technical reference intended to guide contractors on the precise configuration and assembly of the flashing system components. No pricing information, funding sources, contract terms, bidding procedures, or award details are contained within this technical drawing specification.

View the file

Other files

File Type Posted
Project-Allendale Elementary Roofing Replacement.docx DOCX document
Plumbing-Vent-Model.pdf PDF
Hot-Stack-Penetration.pdf PDF
Door-Threshold-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
FAMILIAL RELATIONSHIP DISCLOSURE STATEMENT.docx DOCX document
Project-Allendale Elementary Roofing Replacement.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Rogers Early Elementary- AOC.pdf PDF
Project-Rogers Early Elementary School Roofing Replacement.pdf PDF
Area-Divider-Model.pdf PDF
Light-Metal-Roof-Edge (1).pdf PDF
MELNAP Schools Summer of 2027 Roofing Bid Form.doc DOC document
FAQs PW April 2025.pdf PDF
Prevailing Wage Rates.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Roof-Hatch-Model.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders MELNAP Summer of 2027.docx DOCX document
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Project-Rogers Early Elementary School Roofing Replacement.docx DOCX document
Allendale Elementary- AOC.pdf PDF
MELNAP Schools Summer of 2027 Roofing Scope of Work.docx DOCX document
Wood-Curb-Model.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 27

BUILT UP ROOFING

HOT/COLD SLIP METAL SKIRT FLASHING

FLASHING ADHERED

ROOF DECK AS SPECIFIED

SPECIFIED INSULATION

SPECIFIED BUR

MEMBRANE

TWO-PLY

STRIPPING

SHEET ADHESIVE

WITH SPECIFIED

ELASTOMERIC BASE

INSTALL NEW METAL

COUNTERFLASHING

COUNTERFLASHING

NEW GROMMETED FASTENERS 8" O.C.

EXISTING METAL

GRAVEL SURFACING

SPECIFIED CANT

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

Sheets and Views
Model

File details come from the government source that posted it. Updated .