Plumbing-Vent-Model.pdf

PDF 155 KB Posted

Attached to
ROOFING AT ALLENDALE ELEMENTARY SCHOOL AND ROGERS BUILDING
Solicitation number
RFP MNA 260000002642 1
Issued by
Wayne County, Michigan

About this file

This is a technical specification drawing for plumbing vent stack flashing installations on built-up roofing systems. The document provides detailed construction requirements for hot and cold plumbing vent flashing assemblies, specifying materials, dimensions, and installation methods to ensure proper water-shedding and structural integrity at roof penetrations.

The specification requires soft metal flashings with minimum material standards: sheet lead at 4 pounds per square foot minimum and sheet copper at 16 ounces minimum. When copper flashing is installed over iron or steel pipes, asphalt-coated roofing felt must be applied to prevent galvanic corrosion from dissimilar metals. The flashing assembly includes a rolled soft metal flashing extending one inch down into the pipe, a steel screen, solder stainless plumbing vent stack, a flange set in specified mastic with a minimum 4-inch diameter, and a two-ply tar target adhered to the specified built-up roofing membrane over specified insulation and roof decking. For plumbing vents with diameters less than two inches, soft metal caps extending one inch into the pipe installed in specified adhesive are required. All components must comply with specified material and installation standards, with drawings provided at a not-to-scale reference for construction guidance.

View the file

Other files

File Type Posted
Project-Allendale Elementary Roofing Replacement.docx DOCX document
Hot-Stack-Penetration.pdf PDF
Door-Threshold-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
FAMILIAL RELATIONSHIP DISCLOSURE STATEMENT.docx DOCX document
Project-Allendale Elementary Roofing Replacement.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Rogers Early Elementary- AOC.pdf PDF
Project-Rogers Early Elementary School Roofing Replacement.pdf PDF
Area-Divider-Model.pdf PDF
Light-Metal-Roof-Edge (1).pdf PDF
MELNAP Schools Summer of 2027 Roofing Bid Form.doc DOC document
FAQs PW April 2025.pdf PDF
Prevailing Wage Rates.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Roof-Hatch-Model.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders MELNAP Summer of 2027.docx DOCX document
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Project-Rogers Early Elementary School Roofing Replacement.docx DOCX document
Allendale Elementary- AOC.pdf PDF
MELNAP Schools Summer of 2027 Roofing Scope of Work.docx DOCX document
Wood-Curb-Model.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 08

NOTES

SOFT METAL FLASHINGS

1. SHEET LEAD: MINIMUM 4 LB. (20kg²/m ) PER SQ.FT.

2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED ROOFING FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR

METALS.

BUILT-UP ROOFING HOT/COLD

PLUMBING VENT FLASHING

ROLLED SOFT METAL FLASHING

1'' DOWN INTO PIPE

STEEL SCREEN

OPTIONAL SOLDER STAINLESS:

PLUMBING VENT STACK

PLUMBING VENT STACK

SET FLANGE IN

SPECIFIED MASTIC

MASTIC SEAL

TWO TARGET PLIES ADHERED

SPECIFIED BUR MEMBRANE

SPECIFED INSULATION

ROOF DECK AS SPECIFIED

FOR PLUMBING VENTS WITH

DIAMETERS LESS THAN

2'' USE SOFT METAL CAPS

SOFT METAL CAP 1'' DOWN

INTO PIPE

IN SPECIFIED ADHESIVE

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

AutoCAD SHX Text

4'' MIN. FLANGE

AutoCAD SHX Text

2'' MIN.

Sheets and Views
Model