Flashing-for-Non-Wall-Supported (1).pdf
PDF 144 KB Posted
- Solicitation number
- RFP MNA 260000002642 1
- Issued by
- Wayne County, Michigan
About this file
This is a technical drawing specification document for built-up roof hot/cold wall flashing designed for non-wall-supported deck applications. The drawing, designated as DWG NO. 11 and prepared in 2023, provides detailed construction specifications for a roofing assembly including a specified built-up roof (BUR) membrane with two-ply fasteners spaced at eight-inch on-center intervals. The specification calls for a one-piece counterflashing, specified sealant, and gravel surfacing installed into a reglet and secured with lead wedges at eight-inch intervals. The assembly incorporates flexible vapor retarder insulation, wood nailers secured to the deck with appropriate fasteners in two rows staggered at twenty-four-inch on-center spacing, stripping with specified base flashing rows at twelve-inch on-center spacing with staggered blocking in two rows, and wood cant nailed to sheet. The drawing is presented at a not-to-scale (NTS) ratio and indicates a minimum four-inch clearance requirement for the flashing configuration.
This technical specification document does not contain information regarding pricing terms, set-asides, incumbents, funding sources, response dates, or contract award details. The document serves purely as a technical reference for construction standards and material specifications related to roofing flashing installation and is not accompanied by procurement timeline, financial, or administrative contract information.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 11
BUILT-UP ROOF
HOT/COLD WALL FLASHING FOR
NON-WALL-SUPPORTED DECK
SPECIFIED BUR MEMBRANE
TWO-PLY
FASTENERS 8'' O.C.
ONE PIECE COUNTERFLASHING
SPECIFIED SEALANT
SPECIFIED INSULATION
ROOF DECK AS SPECIFIED
GRAVEL SURFACING
INSTALLED INTO REGLET AND
SECURED w/ LEAD WEDGES 8'' O.C.
FLEXIBLE VAPOR RETARDER
TO SERVE AS INSULATION
RETAINER
COMPRESSIBLE INSULATION
WOOD NAILER SECURED TO
DECK w/ APPROPRIATE
FASTENERS, 2 ROWS
STAGGERED EACH ROW
24'' O.C.
STRIPPING
SPECIFIED BASE FLASHING
ROW 12'' O.C.
STAGGERED EACH
BLOCKING, 2 ROWS
NAIL WOOD CANT TO
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
AutoCAD SHX Text
4'' MIN.