This is a technical drawing specification document detailing fastener placement requirements for a built-up roofing base sheet installation on lightweight concrete decking. The drawing, designated DWG No. 15, specifies the use of approved fasteners with spacing requirements of 7 inches on center along sidelaps and in two equally staggered rows down the longitudinal center of the sheet, positioned 12 inches from each edge. The specification includes provisions for increased fastening density at perimeter edges (70% increase) and corners (160% increase) in accordance with FM Global Loss Prevention Data Sheets 1-28 and 1-29. The fastener spacing shall not be closer than 4 inches on center, with additional rows and increased fasteners per row to be added as necessary based on unit area calculations. The base sheet is specified as Tremco brand material to be attached to the roof decking with specified Tremco fasteners and plates, with a separator layer and lightweight concrete substrate identified in the drawing.
No pricing information, contract terms, response deadlines, award dates, or procurement-related details are contained in this technical specification document. The drawing is presented at not-to-scale (NTS) and represents the 2023 version created in AutoCAD, focusing exclusively on the mechanical installation requirements for the roofing base sheet system rather than commercial or contractual terms.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 15
NOTES
1. ATTACH BASE SHEET TO THE ROOF DECKING WITH APPROVED FASTENERS AND DISCS.
2. SPACE FASTENERS 7 INCHES ON CENTER ALONG SIDELAP AND 7 INCHES ON CENTER IN TWO ROWS
EQUALLY STAGGERED DOWN THE LONGITUDINAL CENTER OF THE SHEET (12 INCHES FROM EACH
EDGE).
3. INCREASE PERIMETER EDGE FASTENING BY 70% AND CORNER FASTENING BY 160% PER FM GLOBAL
LOSS PREVENTION DATA SHEETS 1-28 AND 1-29.
4. DETERMINE FASTENER DENSITY ON A UNIT AREA PER FASTENER BASIS. ADD ADDITIONAL ROWS AND INCREASE FASTENERS PER ROW. DO NOT SPACE FASTENERS CLOSER THAN 4 INCHES ON CENTER.
BUILT-UP ROOFING
HOT/COLD BASE SHEET FASTENER
PLACEMENT FOR LIGHTWEIGHT
CONCRETE
SPECIFIED TREMCO
BASE SHEET
SPECIFIED SEPARATOR
LIGHTWEIGHT CONCRETE
SPECIFIED TREMCO
FASTENER AND PLATE
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
AutoCAD SHX Text
BASE SHEET WIDTH
AutoCAD SHX Text 4"
AutoCAD SHX Text 7"
AutoCAD SHX Text 7"
AutoCAD SHX Text 12"