78_AD104_R1_AMENDMENT 009.pdf
PDF 410 KB Posted
- Solicitation number
- N6247026R0012
About this file
This is an architectural drawing document depicting a Second Floor Removals Plan for Building 60 repairs at Portsmouth Naval Shipyard in Kittery, Maine, prepared by the Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic. The drawing is dated March 16, 2026 (Amendment 009) and shows detailed removal specifications for the second floor of a historic structure with existing masonry exterior wall systems and wood windows.
The plan specifies 27 distinct removal tasks identified by keynote numbers, including removal of stud-framed gypsum board interior partitions, doors and hardware, stair structures and railings, floor systems, plumbing fixtures, ceiling systems (both gypsum board and acoustical tile), various flooring types (rubber, vinyl, hardwood, grip, and wood strip), casework, window railings, ductwork, and steam piping. The drawing includes notes requiring coordination with hazardous materials removal sheets, salvage and reinstallation of historic beadboard ceiling (estimated at 200 square feet), and salvage of wood strip flooring for reinstallation. The plan references coordination with mechanical, structural, and other trade drawings, indicating this is part of a comprehensive renovation project. The document is marked as unclassified and includes a graphic scale of 1/8" = 1'-0" with detailed room layouts and dimensional references throughout the second floor.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
C1
AD201
A1
AD201
C1
AD202
A1
AD202
A1
AD203
C1
AD221
A1
AD221
C1
AD222
abcdefgjknp e1 e2 e3 e4 e5 e6 e7
OPEN TO
BELOW
ROOF BELOW
SEE AD121
EXISTING HISTORIC MASONRY
EXTERIOR WALL SYSTEM (TYP)
6'
7"
20' - 8 3/4" ± 20' - 0 1/4" ± 19' - 10 1/2" ±
WOMENS
STORAGE
STAIR
CONFERENCE
SHOP
207OFFICE
OFFICE
SHOP
OFFICE
OFFICE
CLASSROOM
STAIR
OFFICE
CORRIDOR
OFFICE
STAIR
MENS
CORRIDOR
CLASSROOM
AA
10 10 10 10
20 20 20
STORAGE
11' - 4" ± 13' - 4" ±
1'
4"
44' - 0" ±
1/ 2"
6'
2"
10 2010 2010 2010 20
10 10
C1
AD203
REMOVE STEAM PIPING,
SEE MECHANICAL SHEETS
4'-0 1/2"
5'
3/
4"
4'
1/
4"
22' - 0" ±
8' - 7 3/4" ±
4'
2"
1"
7' - 4" ±
4'
3/
4"
9' - 1 1/4" ± 5' - 5 3/4" ± 15' - 9" ±
/2
15' - 4 1/4" ±
AD401
C4
DN
EXISTING DUCTWORK, SEE
MECHANICAL SHEETS, TYP.
DN
2'-4"
1'-2 3/8"8
EXISTING HISTORICAL
WOOD WINDOW (TYP)
4" ±
REMOVE FLOOR SYSTEM. SEE
STRUCTURAL SHEETS.
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/1
/2
:5
:2
A
M
C U s e rs \m d o n o v a n \D o c u m e n ts \2
.2
B L
D G
A
R C
H
IT
E C
T U
R A
L -V m d o n o v a n
V F
X R
.r v t
AD104
B
R
E P
A
IR
S
S E
C O
N D
F L O
O R
R E
M O
V A
L S
P L A
N
RSH
JMR
MJD
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
A D
SCALE: 1/8" = 1'-0"
B1
SECOND FLOOR REMOVALS PLAN
MATCH LINE
11. SEE SHEET G-004A FOR GENERAL REMOVALS NOTES.
2. COORDINATE REMOVALS WITH HAZARDOUS MATERIALS REMOVALS
SHEETS.
3. REMOVE AND SALVAGE HISTORIC BEADBOARD FROM AREAS THAT
WILL BE CONCEALED BY A CEILING SYSTEM FOR LATER PATCHING.
FOR BIDDING ASSUME 200 SQUARE FEET OF REMOVING AND
REINSTALLING EXISTING BEADBOARD CEILING.
REMOVE STUD FRAMED GYPSUM BOARD INTERIOR PARTITION.
REMOVE DOOR, FRAME, AND HARDWARE.
REMOVE STAIR STRUCTURE AND RAILINGS IN ITS ENTIRETY.
REMOVE VENT.
REMOVE FLOOR SYSTEM, SEE STRUCTURAL SHEETS.
SALVAGE WOOD STRIP FLOORING FOR REINSTALLATION.
REMOVE DOOR AND HARDWARE, FRAME TO REMAIN.
REMOVE PLUMBING FIXTURES, SEE PLUMBING SHEETS.
REMOVE PORTION OF STUD FRAMED GYPSUM BOARD
INTERIOR PARTITION AT BORROWED LIGHT INSTALLATION.
SEE SHEET AE105.
REMOVE CASEWORK.
REPAIR INTERIOR METAL FRAMED STORM WINDOWS. SEE
WINDOW REPAIR SCHEDULE.
PLAN
NORTH
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLANGENERAL NOTES REMOVALS KEYNOTES LEGEND
(THIS SHEET ONLY)
REMOVE RUBBER FLOORING, PLYWOOD
UNDERLAYMENT, MECHANICAL FASTENERS AND
ADHESIVE FROM WOOD STRIP FLOORING. PREP FOR
FLOOR FINISH INDICATED.
REMOVE BULGING AREA OF WOOD STRIP FLOORING.
REMOVE VINYL FLOORING, PLYWOOD
UNDERLAYMENT, MECHANICAL FASTENERS AND
ADHESIVE FROM WOOD STRIP FLOORING. PREP FOR
FLOOR FINISH INDICATED
REMOVE PLYWOOD SHEETS FASTENED TO WOOD
STRIP FLOORING. WOOD STRIP FLOORING TO
REMAIN.
REMOVE GYPSUM BOARD CEILING SYSTEM.
REMOVE ACOUSTICAL CEILING TILE SYSTEM.
REMOVE HARDWOOD FLOORING (FORMER RACQUET
BALL COURT FLOORING). WOOD STRIP FLOORING
BELOW TO REMAIN.
REMOVE ADHERED GRIP FLOORING. WOOD STRIP
FLOORING TO REMAIN.
REMOVE PLYWOOD CEILING.
REMOVE WOOD WINDOW RAILINGS.
SALVAGE, REPAIR, AND STORE STORM WINDOW FOR
RELOCATION/REINSTALLATION.
REMOVE INTERIOR BORROWED LITE.
REMOVE INTERIOR STORM WINDOW.
REMOVE RESILIENT FLOORING, LOOSE LAID OVER
WOOD STRIP FLOORING.
REMOVE DOOR FRAME AND HARDWARE.
REMOVE WOOD FRAMED FLOOR HATCH/COVER.
REMOVE PLYWOOD CEILING FROM EXISTING
BEADBOARD CEILING, BEADBOARD CEILING TO REMAIN.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/1
6/
R
S H
| Sheets |
| AD104 - SECOND FLOOR REMOVALS PLAN |
File details come from the government source that posted it. Updated .