About this file

This document is an architectural drawing—specifically a Reflected Ceiling Plan for the Second Floor of Building 60 Repairs at Portsmouth Naval Shipyard in Kittery, Maine. The drawing, prepared by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic, details ceiling work requirements including removal and replacement of deteriorated beadboard, installation of gypsum board ceilings, acoustical ceiling tile systems, and 1-hour rated ceiling systems. The plan specifies approximately 200 square feet of removing and reinstalling existing beadboard ceiling, 150 additional square feet of replacement work for deteriorated beadboard to be coordinated with the Contracting Officer, and patching of areas where sprinkler heads, light fixtures, and other elements have been removed. Historic beadboard materials are to be salvaged from areas that will be concealed and reused for patching, with new beadboard installed to match existing profiles where salvaged material is unavailable.

The drawing includes detailed keynotes identifying light fixtures, emergency lights, exit signs, diffusers, grilles, existing bridge cranes, and access panels. Finished ceiling heights range from 8 feet to 16 feet 11.5 inches above finished floor across various rooms numbered 201–214. The plan references related sheets for wall types, ceiling types, and room finish schedules. The drawing was finalized on October 1, 2025, with Amendment 008 approved on March 10, 2026. All work is to be included in the lump sum base bid line item.

View the file

Other files

File Type Posted
Solicitation Amendment N6247026R00120011 SF 30.pdf PDF
AMENDMENT 0011 Attachments.zip ZIP file
101_AE121_R1_AMENDMENT 010.pdf PDF
126_AE511_R1_AMENDMENT 010.pdf PDF
132_AE601_R1_AMENDMENT 010.pdf PDF
169_P-101_R1_AMENDMENT 010.pdf PDF
173_P-105_R1_AMENDMENT 010.pdf PDF
177_P-109_R1_AMENDMENT 010.pdf PDF
182_P-601_R2_AMENDMENT 010.pdf PDF
186_MD102_R1_AMENDMENT 010.pdf PDF
275_ET102_R1_AMENDMENT 010.pdf PDF
Solicitation Amendment N6247026R00120009 SF 30.pdf PDF
01 11 00.00 22_R2_AMENDMENT 009.pdf PDF
07 22 00_R1_AMENDMENT 009.pdf PDF
07 42 63_R1_AMENDMENT 009.pdf PDF
07 95 00_R1_AMENDMENT 009.pdf PDF
18_HM101_R1_AMENDMENT 009.pdf PDF
78_AD104_R1_AMENDMENT 009.pdf PDF
79_AD105_R1_AMENDMENT 009.pdf PDF
130_AE531_R1_AMENDMENT 009.pdf PDF
Att. T) Price Schedule AMD 0008.pdf PDF
04_G-004A_R1_AMENDMENT 008.pdf PDF
27_HM604_R1_AMENDMENT 008.pdf PDF
46_SD101_R1_AMENDMENT 008.pdf PDF
56_SB102_R2_AMENDMENT 008.pdf PDF
93_AE102_R2_AMENDMENT 008.pdf PDF
95_AE104_R1_AMENDMENT 008.pdf PDF
96_AE105_R1_AMENDMENT 008.pdf PDF
102_AE131_R1_AMENDMENT 008.pdf PDF
105_AE202_R1_AMENDMENT 008.pdf PDF
161_Q-601_R1_AMENDMENT 008.pdf PDF
178_P-401_R1_AMENDMENT 008.pdf PDF
187_MD103_R1_AMENDMENT 008.pdf PDF
Att. Y) PPI responses AMD 0007.pdf PDF
Solicitation Amendment N6247026R00120005 SF 30.pdf PDF
Att. D) Historical Small Business Utilization AMD 0004.docx DOCX document
Att. T) Price Schedule AMD 0004.pdf PDF
Att. BB) B60 AMD 004 Specifications 012726.pdf PDF
Att. V) SITE VISIT INFORMATION.pdf PDF
Solicitation - N6247026R0012.pdf PDF
Att. B) - Pre-Proposal Inquiry Log Template.xlsx XLSX spreadsheet
Att. C) - Past Performance Questionnaire.docx DOCX document
Att. N) Drawings Volume 2b.pdf PDF
Att. O) 01 30 00 App A Red Zone 102623.pdf PDF
Att. T) Price_schedule.pdf PDF
Att. A) - Construction Experience Project Data.docx DOCX document
Att. D) - Historical Small Business Utilization.docx DOCX document
Att. E) - Small Business Participation Commitment Document (SBPCD).docx DOCX document
Att. F) - Individual Small Business Subcontracting Plan.docx DOCX document
Att. H) Specifications Volume 1.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

abcdefgjknp e1 e2 e3 e4 e5

16' - 11 1/2" A.F.F.

16' - 11 1/2" A.F.F.

003C

8' - 0" A.F.F.

9' - 0" A.F.F.

9' - 0" A.F.F.

9' - 0" A.F.F.

12' - 0" A.F.F.

10' - 0" A.F.F.

10' - 0" A.F.F. 16' - 11 1/2" A.F.F.

004C

3.5

2.8

2.5

2.1 n.9 k.9 k.1

2.4 n.5 k.5

14'-3 3/4"

'-1

1/

4"

8' - 0" A.F.F.

8' - 0" A.F.F.

8' - 0" A.F.F.

8' - 0" A.F.F.

10' - 0" A.F.F.

(ABOVE)

D5

AE720

D5

AE720

(SIM)

16' - 11 1/2" A.F.F.

16' - 11 1/2" A.F.F.

EXISTING

ATTIC HATCH

FIXED CLOSED

(REMOVE AND REPLACE

APPROX 9" (OR 3 BOARD

WIDTHS) OF

DETERIORATED

BEADBOARD FULL

LENGTH OF BUILDING)

(REMOVE AND

REPLACE APPROX 9"

(OR 3 BOARD WIDTHS)

OF DETERIORATED

BEADBOARD FULL

LENGTH OF BUILDING,

ABOVE ACT)

(APPROX 10 SF)

(APPROX 10 SF)

(APPROX (1)

8' BOARD)

(APPROX 10 SF)

(APPROX

12 SF)

(APPROX

20 SF)

(APPROX (1)

8' BOARD) 10 10 10

1. SEE FLOOR PLANS FOR WALL TYPES.

2. SEE SHEET AE001 FOR CEILING TYPES.

3. SEE SHEET AE640 FOR ROOM FINISH SCHEDULE.

4. IN ADDITION TO AREAS INDICATED ABOVE, PATCH EXISTING HISTORIC

BEADBOARD CEILING WHERE SPRINKLER HEADS, LIGHT FIXTURES, AND

OTHER ELEMENTS HAVE BEEN REMOVED AND NOT OTHERWISE

REUSED/COVERED. REMOVE AND SALVAGE HISTORIC BEADBOARD FROM

AREAS THAT WILL BE CONCEALED BY A CEILING SYSTEM FOR PATCHING. FOR

BIDDING ASSUME 200 SQUARE FEET OF REMOVING AND REINSTALLING

EXISTING BEADBOARD CEILING. PATCH THE CEILING AREAS ABOVE THE

CEILING SYSTEMS WHERE SALVAGED BEADBOARD IS REMOVED WITH NEW

BEADBOARD TO MATCH EXISTING BEADBOARD. SEE DETAIL D2/AE704 FOR

EXISTING BEADBOARD PROFILE.

5. IN ADDITION TO THE AREAS INDICATED, PROVIDE 150 SF OF REPLACEMENT

OF DETERIORATED BEADBOARD CEILING WORK FOR WORK NOT OTHERWISE

INDICATED IN THE DRAWINGS, PLANS, SPECIFICATIONS, AND REPORTS.

LOCATIONS TO BE COORDINATED WITH THE CONTRACTING OFFICER. THE

QUANTITIES INDICATED IN PLANS AND SPECIFICATIONS AND NOTED ABOVE

ARE TO BE INCLUDED IN THE LUMP SUM BASE BID LINE ITEM.

REFLECTED CEILING PLAN LEGEND

SYMBOL DESCRIPTION

LIGHT FIXTURE. REFER TO ELECTRICAL SHEETS.

GYPSUM BOARD CEILING.

FINISHED CEILING HEIGHT ABOVE FINISHED FLOORX'-X" A.F.F.

EMERGENCY LIGHT. REFER TO ELECTRICAL SHEETS.

EXIT SIGN. REFER TO ELECTRICAL SHEETS.

WOOD BEAD BOARD CEILING.

2' - 0" X 2' - 0" ACOUSTICAL CEILING TILE SYSTEM.

DIFFUSERS AND GRILLES. REFER TO MECHANICAL SHEETS.

AREA OF NEW BEADBOARD CEILING.

2 7/8"

3/ 4"

SATISFACTORY TO DATE

APPROVED

FOR COMMANDER NAVFAC

SEAL

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SHEET

NAVFAC DRAWING NO.

DESIGNER

DRAWN BY

CHECKED BY

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 14 SEP 2023

DESIGN MANAGER

PROJECT MANAGER

FEAD/PM&E

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

P O

R T

S M

O U

T H

N A

V A

L S

H

IP

Y A

R D

K

IT

T

E R

Y M

E

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

ACTIVITY

1740579

T. CARLETON

L. LYONS

S. RUCINSKI

/1

/2

:1

:2

P

M

C U s e rs \m d o n o v a n \D o c u m e n ts \2

.2

B L

D G

A

R C

H

IT

E C

T U

R A

L -V m d o n o v a n

V F

X R

.r v t

AE704

B

R

E P

A

IR

S

S E

C O

N D

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

RSH

JMR

MJD

K

IT

T E

R Y

M

E P

O R

T S

M O

U T

H N

A V

A L S

H

IP

Y A

R D

R O

IC

C

-M E

A E

MATCH LINE

GENERAL NOTES

GYPSUM BOARD CEILING, PAINT.

EXISTING BEADBOARD CEILING, REFINISH [OPTION 8].

1-HR RATED CEILING SYSTEM C-1, PAINT.

REPLACE DETERIORATED BEABOARD CEILING WITH SALVAGED MATERIAL.

TOOTH INTO EXISITNG BEADBOARD TO CREATE AN INTEGRATED PATCH.

IN AREAS WHERE BEADBOARD CEILING HAS TRANSPARENT, CLEAR COAT

FINISH, REMOVE DUST, DIRT OIL, AND GREASE, RINSE THOROUGHLY. [OPTION 8]

NEW BEADBOARD CEILING WHERE SALVAGED HISTORIC BEADBOARD CEILING IS

REMOVED.

2'-0" x 2'-0" ACOUSTICAL CEILING TILE SYSTEM

EXISTING GYPSUM BOARD CEILING, PAINT.

HOIST BEAM, SEE STRUCTURAL SHEETS.

PLAN

NORTH

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

SCALE: 1/8" = 1'-0"

B1

SECOND FLOOR REFLECTED CEILING PLAN

KEYNOTES

10 INFILL HOLE (MISCELLANEOUS SHAPES

AND SIZES, APPROXIMATELY NO MORE

THAN 2 SF EACH) WITH SALVAGED

MATERIAL. TOOTH INTO EXISTING

BEADBOARD TO CREATE AN INTEGRATED

PATCH.

EXISTING BRIDGE CRANE.

ACCESS PANEL 1'-0" x 1'-0".

EXISTING OPENING WITH PLYWOOD

COVER, PAINT TO MATCH BEADBOARD.

ELECTRICAL CORD REEL, SEE EQUIPMENT

SHEETS.

SCALE: 6" = 1'-0"

D2

BEAD BOARD PROFILE DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

F

IN

A L

S U

B M

IS

S

IO

N

/0

1/

R

S H

A

M E

N D

M E

N T

/1

0/

R

S H

Sheets
AE105 - SECOND FLOOR PLAN
AE704 - SECOND FLOOR REFLECTED CEILING PLAN
HM604 - HAZARDOUS MATERIALS SCHEDULES 2

File details come from the government source that posted it. Updated .