This document is an architectural drawing specification sheet for interior signage types required for a federal building project (Building 60). The sheet details fourteen distinct sign types (A through N) with specific dimensional, material, and content requirements for a multi-story facility with elevator access, stair systems, and specialized rooms.
The signage specifications include: Type A (electrical room identification, 9" x 9"); Type B (exit signage with 3/4" tactile messaging); Type C (room name signs with removable end caps); Type D (accessible entrance signage with pictograms); Type E (stair identification with floor information, 1'-2" x 1'-7"); Type F (fire emergency instructions at elevator stops); Type G and H (restroom signage with accessible pictograms, 9" x 9"); Type J (roof access restriction signage); Type K (fire extinguisher signage, 8" x 1'-6"); Type M (mezzanine storage restriction, 9" x 4"); and Type N (live load capacity signage, 9" x 4"). All signage requires tactile text in Helvetica Neue 55 Roman font with Grade 2Braille where applicable. The document specifies quantities and placement locations, including 15 coordinate fire extinguisher signs per life safety drawings, single signs above elevator machine rooms and inspection areas, and signage at each elevator stop. The drawing is dated 3/10/2026 and marked UNCLASSIFIED, with project identifier 22103.25 for Building 60 Architectural specifications.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WOMENMEN
TEXT: 6" HIGH PICTOGRAM
TEXT: 6" HIGH RAISED
PICTOGRAM
ELECTRICAL
STAIR A
EXIT
IN CASE OF FIRE
DO NOT USE
ELEVATOR
USE EXIT STAIRS
ROOM
NAME
REMOVABLE END CAPS
3" 6"
9"
TEXT: 1-1/2" TACTILE ROOM
NUMBER WITH GRADE 2 BRAILLE
HELVETICA NEUE 55 ROMAN
TEXT: 3/4" TACTILE ROOM NAME,
WITH GRADE 2 BRAILLE
HELVETICA NEUE 55 ROMAN 9"
3" 6"
9"
TEXT: 1-1/2" TACTILE ROOM
NUMBER WITH GRADE 2 BRAILLE
HELVETICA NEUE 55 ROMAN
TEXT: 3/4" PRINTED PAPER
ROOM NAME, HELVETICA NEUE
55 ROMAN
2" 8"
3"
1' -1
9"
TEXT: 1" TACTILE MESSAGE WITH
GRADE 2 BRAILLE HELVETICA
NEUE 55 ROMAN
TEXT: 1-1/2" TACTILE STAIR
IDENTIFICATION WITH GRADE 2
BRAILLE HELVETICA NEUE 55
ROMAN
3" 8"
9"
6" PICTOGRAM
TEXT: 3/4" TACTILE ROOM NAME
WITH GRADE 2 BRAILLE
HELVETICA NEUE 55 ROMAN
9"
3" 8"
TEXT: 5/8" TACTILE
MESSAGE, HELVETICA
NEUE 55 ROMAN
1'-0"
6" 1'
-0
1' -6
SIGN TYPE A
SIGN TYPE D
SIGN TYPE H
SIGN TYPE F
SIGN TYPE G
SIGN TYPE C
FLOOR
NO ROOF ACCESS
FIRST TO
SECOND FLOOR
EXIT ON LEVEL 1
TEXT: 1" TACTILE MESSAGE,
HELVETICA NEUE 55 ROMAN
LEVEL NUMBER: 5" TACTILE
MESSAGE, HELVETICA NEUE
55 ROMAN, TACTILE
1" STAIR INFORMATION
MESSAGE, HELVETICA
NEUE 55 ROMAN
EXIT INFORMATION: 1"
HELVETICA NEUE 55 ROMAN
STAIR IDENTIFICATION: 1-1/2"
TACTILE MESSAGE, HELVETICA
NEUE 55 ROMANSTAIR A
1' -7
1'-2"
SIGN TYPE E
ROOF
ACCESS
AUTHORIZED
PERSONNEL
ONLY
TEXT: 3/4" TACTILE
MESSAGE, HELVETICA
NEUE 55 ROMAN
9"
9"
SIGN TYPE J
TEXT: 5/8" TACTILE MESSAGE
W/ GRADE 2 BRAILLE
HELVETICA NEUE 55 ROMAN
3"
9"
SIGN TYPE B
EXIT
3"
ACCESSIBLE EXIT AT
WEST SIDE OF
BUILDING
ROOF ACCESS
INFORMATION: 1"
HELVETICA NEUE 55 ROMAN
LADDER SIGN
(AUTHORIZED PERSONNEL
ONLY): PROVIDE AT FIXED
LADDER ADJACENT TO
ELEVATOR ON 2ND FLOOR
SIGN TYPE K
8"
1' -6
1" 1"
E
X
T
I
N
G
U
I
S
H
E
R
FIRE
X
T
I
N
G
U
I
S
H
R
FIRE
NOTE:
QUANTITY 15- COORDINATE FE SIGNS WITH
FE LOCATIONS INDICATED ON THE LIFE
SAFETY DRAWINGS.
4"
9"
TEXT: 5/8" TACTILE ROOM NAME,
HELVETICA NEUE 55 ROMAN
NO STORAGE
AT MEZZANINE
LEVEL
REMOVABLE END CAPS
SIGN TYPE M
NOTE:
PROVIDE (1) EACH ABOVE ELEV MACHINE
ROOM, OVERHEAD DOOR VESTIBULE,
INSPECTION ROOM AND ELEC ROOM (4) TOTAL
NOTE:
PROVIDE AT EACH ELEVATOR STOP
4"
9"
TEXT: 5/8" TACTILE ROOM NAME,
HELVETICA NEUE 55 ROMAN
LIVE LOAD
CAPACITY =
25 PSF
SIGN TYPE N
NOTE:
PROVIDE AT MEZZANINE LEVEL
OVERHEAD DOOR VESTIBULE.
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/1
/2
:4
:4
P
M
C U s e rs \m d o n o v a n \D o c u m e n ts \2
.2
B L
D G
A
R C
H
IT
E C
T U
R A
L -V m d o n o v a n
V F
X R
.r v t
AE131
B
R
E P
A
IR
S
T Y
P
IC
A L S
IG
N
A G
E D
E T
A
IL
S
RSH
JMR
MJD
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
A E
SCALE: NOT TO SCALE
A1
SIGN TYPES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/1
0/
R
S H
| Sheets |
| AE102 - FIRST FLOOR PART PLAN - WEST |
| AE104 - FIRST FLOOR MEZZANINE PART PLAN - WEST |
| AE131 - TYPICAL SIGNAGE DETAILS |
| AE202 - EXTERIOR ELEVATIONS 1 |
| AE804 - SECOND FLOOR FF&E PLAN (OPTION 1) |
| G-004A - ABBREVIATIONS, LEGEND, AND GENERAL PROJECT NOTES - VOLUME 1 |
| G-004B - ABBREVIATIONS, LEGEND, AND GENERAL PROJECT NOTES - VOLUME 2 |
| Q-601 - EQUIPMENT SCHEDULE (OPTION 2) |