Attachment Q - P332 Elect Pwr Plnt FDA - AG601 - SIGNAGE DETAILS AND SCHEDULE.pdf
PDF 281 KB Posted
- Solicitation number
- N6247023R0001
About this file
This document provides signage details and a schedule for the P-332/P-334 Electrical Power Plant project at Camp Lemonnier, Djibouti. The signage includes interior and exterior signs with tactile and Braille text as required by ADA guidelines. The interior sign locations correspond to rooms 103 through 127 as shown on sheets AF101-AF102. Exterior signs denote building entrances, prohibited smoking areas, and non-entrance locations. The signage materials, style, dimensions and mounting details are specified. Tactile text spacing and clear floor areas around signs are also delineated.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-1 B-1
D-1
E-1
(EXTERIOR)
19 MM (3/4") ADA/ABA
TACTILE COPY WITH
BRAILLE
75 MM (3")
SYMBOL
E-2
(EXTERIOR)
19 MM (3/4") ADA/ABA
TACTILE COPY WITH
BRAILLE
19 MM (3/4")
ADA/ABA TACTILE
COPY
E-3
(EXTERIOR)
25 MM (1")
ADA/ABA
TACTILE COPY
ROOM
DESCRIPTION
ROOM DESC.10
SMOKING PROHIBITED
WITHIN 15 M OF
BUILDING PERIMETER
NOT AN
ENTRANCE
UNISEX
EXIT
101.6 MM (4")
SYMBOL
19 MM (3/4") ADA/ABA
TACTILE COPY WITH
BRAILLE
V-STYLE 45 DEGREE FLAG.
MOUNT SIGN DIRECTLY ABOVE FIRE
EXTINGUISHER BRACKETS AT 2032 MM
(80") AFF MINIMUM TO BOTTOM OF SIGN.
RED
BACKGROUND
C-1
RED TEXT
ON WHITE
ARROW
BLACK TEXT
ON WHITE
BACKGROUND
19 MM (3/4")
ADA/ABA TACTILE
COPY WITH BRAILLE
19 MM (3/4") ADA/ABA
TACTILE COPY
D-2
152.4 MM (6") SYMBOL
38.1 MM (1-1/2")
ADA/ABA TACTILE
COPY WITH BRAILLE
EXIT
STAIR #
ROOF ACCESS
25 MM (1") ADA/ABA
TACTILE COPY WITH
BRAILLE
C-2
NOT TO SCALE
V-STYLE 45 DEGREE FLAG.
MOUNT SIGN DIRECTLY ABOVE
SHOWER/EYEWASH AT 2032 MM (80")
AFF MINIMUM TO BOTTOM OF SIGN.
NOT TO SCALE
WHITE TEXT ON
GREEN BACKGROUND
GREEN TEXT ON
WHITE BACKGROUND
12.7 MM (1/2") ADA/ABA
TACTILE COPY
FINISHED
FLOOR
228.6 (9")
457.2 (18") CLEAR FIELD
7.
(1
8" ) C
LE
A
R F
IE
LD
XXX
TEXT
D
IS
T A
N C
E A
.F .F
. F R
O M
B
A S
E
LI
N E
O F
H
IG
H E
S T
T A
C T
IL
E
C
H A
R A
C T
E R
D
IS
T A
N C
E A
.F .F
. F R
O M
B
S
E
LI
N E
O F
L O
W E
S T
T
C
T
IL
E C
H A
R A
C T
E R
(5 '-0
M
A X
(4 '-0
M
IN
FROM INSIDE
JAMB TO
CENTERLINE
OF SIGN
TEXT
457.2 (18") MIN
.2
M
IN
CL
SIGNS CONTAINING TACTILE CHARACTERS SHALL HAVE
AN 457.2 (18") MINIMUM BY 457.2 (18") MINIMUM SPACE
ON THE FLOOR OR GROUND, CENTERED ON THE SIGN,
BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE
CLOSED POSITION AND 45 DEGREE OPEN PANEL.
(INSTALL SIGN ON THE NEAREST ADJACENT WALL IF
457.2 (18") MIN. OF CLEAR SPACE IS NOT AVAILABLE.)
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A V A L F A C
IL
IT
IE
S E N G
IN
E E R
IN
G S Y S T E M S C O M M A N D A T L A N T
IC
N O
R F
O L
K V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N
DPS
/2
/2
:4 :3
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
A
.r v t
AG601
P -3 /P -3 E L E C T R
IC
A L P O W E R P L A N T
S
IG
N A G E D E
TA
IL
S A N D S C H E D U
LE
MET
14124475
DNM ACB
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
DER
1 : 5B1
SIGNAGE DETAILS
1 : 20A1
SIGNAGE MOUNTING HEIGHT
1 : 20A2
SIGNAGE LOCATION
1:5 0 0.1 0.4 0.5m0.30.2
1:20 0 2m0.5 1 1.5
GRAPHIC SCALE(S)
GENERAL NOTES
A. CONTRACTOR IS RESPONSIBLE FOR SITE VERIFICATION OF CONDITIONS AND
DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION OF ITEMS
DESCRIBED ON PLANS AND IN SPECIFICATIONS. PROVIDE ANY ADDITIONAL
HARDWARE OR SIMILAR ITEMS AS MAY BE REQUIRED FOR A COMPLETE
INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THE
INSTALLATION. VARIANCES SHALL BE REPORTED TO THE CONTRACTING
OFFICER PRIOR TO PROCEEDING WITH THE WORK.
B. WORK MUST CONFORM TO APPLICABLE CODES AND REGULATIONS. ADA
SIGNAGE WITH BRAILLE AND TACTILE TEXT IS NOT REQUIRED IN THE ENGINE
HALLS.
C. FOR SIGNS INDICATED AT EXTERIOR LOCATIONS, SIGNAGE MATERIALS TO
BE RECOMMENDED AND APPROVED BY MANUFACTURER FOR EXTERIOR
APPLICATION.
D. REFER TO SHEETS AF101 - AF102 FOR SIGNAGE LOCATIONS.
E. SIGN SPECIFICATIONS:
BASIS OF DESIGN: SYSTEM 290 PLAQUES
BACKGROUND FINISH: 760 DENIM
COPY FINISH: 708 SOFT WHITE
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
E V
IS
IO
N
D A
T E
SIGNAGE SCHEDULE
LOCATION TEXT COPY INSERT COPY REMARKS
102 CORRIDOR A-1 103 JANITOR
102 CORRIDOR A-1 106 CONTROL INSERT PAPER
102 CORRIDOR B-1 UNISEX MAN SYMBOL, WOMAN SYMBOL,
HANDICAP SYMBOL
102 CORRIDOR B-1 UNISEX MAN SYMBOL, WOMAN SYMBOL,
HANDICAP SYMBOL
102 CORRIDOR C-1 FIRE EXTINGUISHER DO NOT BLOCK
106 CONTROL A-1 107 OFFICE INSERT PAPER
106 CONTROL A-1 108 OFFICE INSERT PAPER
106 CONTROL A-1 109 STORAGE
106 CONTROL C-1 FIRE EXTINGUISHER DO NOT BLOCK
109 STORAGE A-1 110 SCADA
109 STORAGE A-1 111 COMM
113 MECHANICAL C-1 FIRE EXTINGUISHER DO NOT BLOCK
113 MECHANICAL D-2 STAIRS #, ROOF ACCESS, EXIT
114 ELECTRICAL HALL A-1 115 BATTERY
114 ELECTRICAL HALL D-1 EXIT
114 ELECTRICAL HALL D-1 EXIT
117 ENGINE HALL A-1 116 VESTIBULE
117 ENGINE HALL A-1 119 FUEL OIL OVERFLOW TANK
117 ENGINE HALL A-1 119 FUEL OIL OVERFLOW TANK
117 ENGINE HALL A-1 120 DAY TANK
117 ENGINE HALL A-1 121 DAY TANK
117 ENGINE HALL A-1 122 DAY TANK
117 ENGINE HALL A-1 122 DAY TANK
117 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
117 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
117 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
117 ENGINE HALL C-2 EMERGENCY SHOWER EMERGENCY EYE
WASH
117 ENGINE HALL C-2 EMERGENCY SHOWER EMERGENCY EYE
WASH
117 ENGINE HALL C-2 EMERGENCY SHOWER EMERGENCY EYE
WASH
117 ENGINE HALL D-1 EXIT
117 ENGINE HALL D-1 EXIT
117 ENGINE HALL D-1 EXIT
123 ENGINE HALL A-1 114 ELECTRICAL
123 ENGINE HALL A-1 116 VESTIBULE
123 ENGINE HALL A-1 124 DAY TANK
123 ENGINE HALL A-1 125 DAY TANK
123 ENGINE HALL A-1 126 DAY TANK
123 ENGINE HALL A-1 127 LUBE OIL
123 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
123 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
123 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
123 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
123 ENGINE HALL C-1 FIRE EXTINGUISHER DO NOT BLOCK
123 ENGINE HALL C-2 EMERGENCY SHOWER EMERGENCY EYE
WASH
123 ENGINE HALL C-2 EMERGENCY SHOWER EMERGENCY EYE
WASH
123 ENGINE HALL C-2 EMERGENCY SHOWER EMERGENCY EYE
WASH
123 ENGINE HALL D-1 EXIT
123 ENGINE HALL D-1 EXIT
123 ENGINE HALL D-2 STAIRS #, ROOF ACCESS, EXIT STAIR SYMBOL
EXTERIOR E-1 112 RISER ROOM
EXTERIOR E-1 113 MECHANICAL
EXTERIOR E-1 114 ELECTRICAL
EXTERIOR E-1 114 ELECTRICAL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-2 SMOKING PROHIBITED WITHIN 15 M OF
BULDING PERIMETER
NO SMOKING SYMBOL
EXTERIOR E-3 NOT AN ENTRANCE
EXTERIOR E-3 NOT AN ENTRANCE
EXTERIOR E-3 NOT AN ENTRANCE
EXTERIOR E-3 NOT AN ENTRANCE
EXTERIOR E-3 NOT AN ENTRANCE
| Sheets |
| AG601 - SIGNAGE DETAILS AND SCHEDULE |
File details come from the government source that posted it. Updated .