This solicitation is for the design and construction of an electrical power plant at Camp Lemonnier, Djibouti. The Navy is seeking bids for the project, which includes building a new power plant facility along with associated site infrastructure. Key project details include designing and constructing a main power plant building housing multiple generator sets and switchgear, along with exterior equipment such as radiators, transformers, and a motor control center. Site work involves installing foundations and slabs for this equipment as well as fuel storage tanks and support structures. Construction drawings provide framing and reinforcement details for the building's low roof, mechanical platforms, and roof. The solicitation response deadline is December 13, 2022, with award planned for early 2023 and work expected to be complete by 2025.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AB ANCHOR BOLT
AFF ABOVE FINISHED FLOOR
AHR ANCHOR
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BD BAR DIAMETER
BOC BOTTOM OF CONCRETE
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOSL BOTTOM OF SLAB
BRG BEARING
CFS COLD-FORMED STEEL
CJ SLAB CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONT CONTINUOUS
DCJ DOWELED CONSTRUCTION JOINT
DIA, Ø DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
ELEV ELEVATION
EOS EDGE OF SLAB
EQ EQUAL
ES EACH SIDE
EW EACH WAY
FFE FINISHED FLOOR ELEVATION
FOB FACE OF BRICK
FS FAR SIDE
FTG FOOTING
GA GAGE
GALV GALVANIZED
HORIZ HORIZONTAL
HS HIGH STRENGTH
JBE JOIST BEARING ELEVATION
KSI KIPS PER SQUARE INCH
KIP (k) 1000 LBS
LBS POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
MAX MAXIMUM
MFR MANUFACTURER
MIN MINIMUM
MOW MIDDLE OF WALL
NIC NOT IN CONTRACT
No. NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT-FILLER STRIP
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCING
REQD REQUIRED
SCHED SCHEDULE
SD SLAB DEPRESSION
SF STEPPED FOOTING
SIM SIMILAR
SJ SLAB SAWED (CONTRACTION) JOINT
SL SLOPE(D)
SOG SLAB-ON-GRADE
STD STANDARD
SWP SHEAR WALL PANEL
T&B TOP AND BOTTOM
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOGB TOP OF GRADE BEAM
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOSL TOP OF SLAB
TS THICKENED SLAB
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
VERT VERTICAL
WP WORKING POINT
WWR WELDED WIRE REINFORCEMENT
GENERAL NOTES
1. COORDINATE STRUCTURAL WORK WITH ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, AND OTHER DRAWINGS AND SPECIFICATIONS AND REPORT DISCREPANCIES TO THE STRUCTURAL
ENGINEER OF RECORD. COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO THE REQUIREMENTS FOR SLEEVES, INSERTS, HOLES, PRINCIPAL OPENINGS, DEPRESSIONS, EQUIPMENT PADS, HANGERS, AND ANCHORS.
2. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±XXX] REFERENCED TO THE FINISHED
FIRST FLOOR DATUM. REFER TO THE CIVIL DRAWINGS FOR DATUM ELEVATION.
3. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE CONTRACTING OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE AFFECTED. DO NOT SCALE DIMENSIONS
FROM THE DRAWINGS.
4. DETAILS AND SECTIONS APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR REFERENCED, BUT ALSO
IN OTHER LIKE OR SIMILAR CONSTRUCTION THAT REQUIRES THEIR USE.
5. THE STRUCTURAL DRAWINGS CONTAINED HEREIN REPRESENT THE FINISHED STRUCTURE. PROVIDE TEMPORARY SHORING, GUYING, AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL STRUCTURAL WORK, INCLUDING CONNECTIONS, IS COMPLETE. THE ANALYSIS, DESIGN, SAFETY, ADEQUACY, AND INSPECTION OF SUCH TEMPORARY SUPPORTS ARE THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
6. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND SUPERVISION OF THE WORK ARE THE
SOLE RESPONSIBILITY OF THE CONTRACTOR.
7. REPRODUCTION OF CONTRACT DRAWINGS FOR USE AS SHOP DRAWINGS IS NOT PERMITTED IN ANY
CIRCUMSTANCE.
8. DO NOTE DEVIATE FROM THE STRUCTURAL DRAWINGS WITHOUT WRITTEN APPROVAL OF THE
CONTRACTING OFFICER.
9. CONCENTRICALLY FASTEN VERTICALLY- OR LATERALLY-SUPPORTED COMPONENTS TO THE SUPPORTING
STRUCTURAL MEMBER, UNLESS OTHERWISE NOTED.
10. THIS PROJECT REQUIRES SPECIAL INSPECTIONS AS DESCRIBED IN THE APPLICABLE BUILDING CODE.
REFER TO THE STATEMENT OF SPECIAL INSPECTIONS IN THE PROJECT SPECIFICATIONS FOR
REQUIREMENTS.
11. WHERE PLAN DIMENSIONS OR ELEVATIONS ARE PROVIDED WITHOUT UNITS, THE UNIT OF MEASUREMENT IS MILLIMETERS (mm), UNLESS OTHERWISE NOTED.
DESIGN NOTES
DESIGN WIND PRESSURE FOR
ROOF COMPONENTS (kPa)
0.1 - 9.9
ROOF ZONE
10+
COMPONENT TRIBUTARY AREA (m2)
+1.1 -1.8 -1.8
-2.7 -2.2
-3.5 -2.8
1'
+0.9
DESIGN WIND PRESSURE FOR
WALL COMPONENTS (kPa)
0.1 - 9.9
WALL ZONE
10+
COMPONENT TRIBUTARY AREA (m2)
+1.8 -1.9 -1.7
-2.2 -1.85
+1.6
+1.6
+1.8
1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND CRITERIA:
A. UFC 1-200-01, DoD BUILDING CODE, WITH CHANGE 1, 01 OCTOBER 2020
B. UFC 3-301-01, STRUCTURAL ENGINEERING, 01 OCTOBER 2019
C. UFC 3-320-06A, CONCRETE FLOOR SLABS ON GRADE SUBJECTED TO HEAVY LOADS, 01 MARCH 2005 D. UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, WITH CHANGE 1, 19 AUGUST 2020
E. 2018 INTERNATIONAL BUILDING CODE
F. ASCE 7-16, MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER
STRUCTURES
G. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
H. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
2. DESIGN LOAD CRITERIA:
A. RISK CATEGORY III
B. LIVE LOADS (UNIFORM):
ROOFS 1.0 kPa CATWALKS 1.9 kPa MECHANICAL ROOF PLATFORM GRATING 4.8 kPa STAIRS AND EGRESS 4.8 kPa MECHANICAL/ELECTRICAL ROOMS 12 kPa EXHAUST SERVICE PLATFORMS 7.2 kPa SLAB-ON-GRADE (ENGINE HALLS) 24 kPa SLAB-ON-GRADE, UON 12 kPa
TRENCH GRATING AS INDICATED
LIVE LOADS (CONCENTRATED):
SLAB-ON-GRADE, UON (APPLIED TO 0.6 M2) 8.9 kN HL-93 WHEEL LOAD, ENGINE HALLS 72 kN FORKLIFT WHEEL LOAD, ENGINE HALLS 23 kN
B. SNOW LOADS:
GROUND SNOW LOAD, Pg 0 kPa
SNOW LOAD IMPORTANCE FACTOR, IS 1.10
THERMAL FACTOR, Ct 1.0 FROST PENETRATION 0 mm SLOPED-ROOF SNOW LOAD, PS 0 kPa
C. WIND LOADS:
ULTIMATE DESIGN WIND SPEED, V(ULT) 169 km/h NOMINAL DESIGN WIND SPEED, V(ASD) 131 km/h
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi ±0.55 WIND BASE SHEAR (ULTIMATE, 1.0W) VX=760 kN (PLAN EAST-WEST)
VY=230 kN (PLAN NORTH-SOUTH)
D. COMPONENTS AND CLADDING WIND PRESSURES:
USE WIND PRESSURES BELOW FOR THE DESIGN OF COMPONENT AND CLADDING ELEMENTS OR
RETAIN A PROFESSIONAL ENGINEER TO DETERMINE WIND PRESSURES FOR SPECIFIC EFFECTIVE
WIND AREAS.
NOTES:
1. POSITIVE AND NEGATIVE SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY
FROM THE SURFACES, RESPECTIVELY.
2. BUILDING ZONES ARE DEFINED IN ASCE 7.
3. WIND PRESSURES INDICATED ARE AT STRENGTH-LEVEL (WIND LOAD FACTOR = 1.0).
4. DESIGN WIND PRESSURES FOR DEFLECTION-CONTROLLED COMPONENTS AND
CLADDING MAY UTILIZE A 10-YEAR MEAN RECURRENCE INTERVAL.
LATERAL LOAD-RESISTING SYSTEM NOTES
1. THE LATERAL LOAD-RESISTING SYSTEM OF THE COMPLETED STRUCTURE IN THE NORTH-SOUTH AND
EAST-WEST DIRECTIONS IS PROVIDED BY SPECIAL REINFORCED CONCRETE SHEAR WALLS.
2. CONCRETE SLABS ON STEEL DECK AT THE ROOF LEVELS ARE RIGID DIAPHRAGMS THAT DISTRIBUTE
LATERAL WIND AND SEISMIC FORCES HORIZONTALLY TO THE SHEAR WALLS.
FOUNDATION NOTES
1. FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE 'REPORT OF
GEOTECHNICAL EXPLORATION' BY GEOENVIRONMENTAL RESOURCES, DATED 16 JUNE 2022.
2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON UNDISTURBED, FIRM NATURAL SOIL OR ENGINEERED FILL WITH A NET ALLOWABLE BEARING CAPACITY OF 100 kPa. UNDERCUT FOUNDATIONS AS INDICATED ON
SHEET SB100.
3. PRIOR TO PLACING FOUNDATION CONCRETE, AN INDEPENDENT TESTING LABORATORY AND
GEOTECHNICAL ENGINEER QUALIFIED IN ACCORDANCE WITH THE SPECIFICATIONS MUST INSPECT
FOUNDATION EXCAVATIONS TO EVALUATE THE EXTENT OF LOOSE, SOFT OR OTHERWISE
UNSATISFACTORY SOIL MATERIAL AND TO VERIFY THE BEARING CAPACITY. SOILS NOT SUITABLE FOR
FOUNDATION SUPPORT MUST BE UNDERCUT AND REPLACED WITH ENGINEERED FILL.
4. ADEQUATELY PROTECT FOUNDATION EXCAVATIONS TO PREVENT WATER FROM ACCUMULATING AND STANDING IN THE EXCAVATION BOTTOMS. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR
SATURATED SUBGRADES.
5. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES AND THICKNESSES INDICATED
ON THE FOUNDATION PLAN.
6. PLACE FOUNDATION CONCRETE THE SAME DAY EXCAVATIONS ARE MADE OR AS SOON AS PRACTICAL
THEREAFTER.
7. DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED WITH ADJACENT UNDERGROUND UTILITIES AND STRUCTURES. ANY FOOTING STEPS INDICATED ON PLAN ARE SCHEMATIC
AND MUST BE COORDINATED WITH OTHER TRADES.
8. CONTINUOUS FOOTINGS MUST BE LOWERED AS REQUIRED TO PASS UNDER UTILITY LINES. STEP CONTINUOUS FOOTINGS DOWN AS SHOWN IN THE “TYPICAL STEPPED FOOTING” DETAIL ON SHEET SB501.
IN LIEU OF STEPPED FOOTINGS, PIPE SLEEVES BELOW CONTINUOUS FOOTINGS MAY BE PROVIDED IN
ACCORDANCE WITH THE “TYPICAL PIPE SLEEVE BENEATH FOOTING” DETAIL ON SHEET SB501.
DELEGATED DESIGN NOTES
1. DESIGN RESPONSIBILITY FOR THE FOLLOWING STRUCTURAL SYSTEMS AND COMPONENTS IS DELEGATED
TO A QUALIFIED SPECIALTY STRUCTURAL ENGINEER RETAINED BY THE CONTRACTOR. THESE SYSTEMS
AND COMPONENTS INCLUDE, BUT ARE NOT LIMITED TO:
A. SELF-SUPPORTING EXHAUST STACKS (ALL COMPONENTS ABOVE CONCRETE PIER)
B. COLD-FORMED STEEL FRAMING AND CONNECTIONS
C. STRUCTURAL STEEL CONNECTIONS
D. OVERHEAD BRIDGE CRANES, INCLUDING RAILS, STOPS
E. EXTERIOR EQUIPMENT SUPPORT FRAMING (RADIATORS, MOTOR CONTROL CENTER)
F. SOUND BARRIER WALL
G. STEEL STAIRS AND LADDERS
H. STEEL RAILINGS AND ANCHORAGE
I. SLIDE BEARINGS FOR ROOF TRUSSES
J. FUEL FARM CATWALK AND STAIR SYSTEM
K. SEISMIC BRACING FOR NON-STRUCTURAL COMPONENTS PER ASCE 7 CHAPTER 13
L. ANTITERRORISM BRACING FOR NON-STRUCTURAL COMPONENTS PER UFC 4-010-01
2. DELEGATED ENGINEERED SYSTEMS AND COMPONENTS MUST SATISFY ASCE 7 AND REQUIREMENTS OF
APPLICABLE MATERIAL-SPECIFIC STANDARDS.
3. COORDINATE WITH THE CONTRACT DOCUMENTS FOR PROFESSIONAL LICENSURE AND SEALING
REQUIREMENTS, DESIGN CRITERIA, DETAILS OF THE SYSTEM/COMPONENT INTERFACE WITH THE PRIMARY
STRUCTURE, AND SUBMITTAL AND CALCULATION REQUIREMENTS.
4. DO NOT FABRICATE OR INSTALL DELEGATED DESIGN ITEMS UNTIL SUBMITTED DELEGATED DESIGN
DOCUMENTS HAVE BEEN REVIEWED AND APPROVED BY THE CONTRACTING OFFICER.
DESIGN NOTES (CONTINUED)
E. SEISMIC LOADS:
RISK CATEGORY III
SEISMIC IMPORTANCE FACTOR, IE 1.25
SPECTRAL RESPONSE ACCELERATION, SS 1.02g SPECTRAL RESPONSE ACCELERATION, S1 0.41g SPECTRAL RESPONSE COEFFICIENT, SDS 0.816g SPECTRAL RESPONSE COEFFICIENT, SD1 0.410g
SITE CLASS C
SEISMIC DESIGN CATEGORY D
SEISMIC FORCE-RESISTING SYSTEM SPECIAL REINFORCED
CONCRETE SHEARWALLS
RESPONSE MODIFICATION COEFFICIENT, R 5
DEFLECTION AMPLIFICATION FACTOR, Cd 5
SEISMIC RESPONSE COEFFICIENT, CS 0.204
SEISMIC BASE SHEAR (ULTIMATE, 1.0E) V =9100 kN
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
-4.5 -3.23
+1.1 +0.9
+1.1 +0.9
+1.1 +0.9
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N
/1 /2
:5
:3
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
S-001
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
S
TR
U C
T U
R A
L N
O
TE
S A
N D
A B
B R
E V
IA
T
IO
N
S
MSH
14124412
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
DPS
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
SLOPE DIRECTION
BRICK
CONCRETE
EARTH FILL
CONCRETE MASONRY UNIT (CMU)
POROUS FILL
INDICATES ELEVATION
REFERENCED TO FINISHED
FIRST FLOOR
DECK SPAN
KEYED CONSTRUCTION NOTE
COLUMN REFERENCE LINE
(CENTERLINE OF COLUMN)
SPOT ELEVATION
WALL TYPE
GROUT
SLAB DEPRESSION
DN
X
MOMENT CONNECTION
WELDED WIRE REINFORCEMENT
10k W24x55 (16) C=1" 10k
END REACTIONS
BEAM SIZE
# SHEAR STUDS
CAMBER
Wn
[±XXX]
[±XXX]
CHANGE IN SLAB ELEVATION
STRUCTURAL LEGEND
SYMBOL DESCRIPTIONSTRUCTURAL CONCRETE NOTES
1. COMPLY WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS, ACI 301-16 (SPECIFICATIONS FOR
STRUCTURAL CONCRETE), AND ACI 117-10 (SPECIFICATION FOR TOLERANCES FOR CONCRETE
CONSTRUCTION AND MATERIALS), EXCEPT AS MODIFIED BY THESE NOTES OR OTHERWISE NOTED.
2. CAST-IN-PLACE CONCRETE MUST BE NORMAL-WEIGHT AND ATTAIN THE FOLLOWING MINIMUM 28-DAY COMPRESSIVE STRENGTHS (f'c), UNLESS OTHERWISE NOTED:
A. WALLS, COLUMNS, BEAMS, STRUCTURAL SLABS 35 MPa B. CONCRETE ON STEEL DECK 30 MPa C. SLAB-ON-GRADE 30 MPa D. ENGINE FOUNDATIONS 30 MPa E. UTILITY TRENCH SLABS AND WALLS 30 MPa F. FOOTINGS, PIERS, AND GRADE BEAMS 35 MPa G. OTHER INTERIOR CONCRETE 25 MPa H. EXTERIOR CONCRETE, UON 35 MPa
3. CONCRETE REINFORCING STEEL NOTED AS 'SPECIAL SEISMIC REINFORCING' MUST BE DEFORMED BARS
CONFORMING TO EITHER OF THE FOLLOWING STANDARDS:
A. ASTM A706, GRADE 420 MPa (60 KSI) B. ASTM A615, GRADE 420 MPa (60 KSI), PLUS THE DUCTILITY REQUIREMENTS INDICATED IN THE
SPECIFICATIONS.
'SPECIAL SEISMIC REINFORCING' INCLUDES LONGITUDINAL COLUMN BARS AND DOWELS,
LONGITUDINAL BEAM BARS, BUILDING WALL VERTICAL REINFORCING BARS AND DOWELS, AND ANY
OTHER REINFORCING NOTED TO BE 'SPECIAL SEISMIC REINFORCING'.
4. ALL OTHER CONCRETE REINFORCING STEEL MUST BE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 420 MPa (60 KSI).
5. WELDED WIRE REINFORCEMENT (WWR) MUST CONFORM TO ASTM A1064 AND MUST BE SHEET-TYPE.
SHEET LAPS MUST BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 50mm.
6. REINFORCING STEEL MUST BE CONTINUOUS UNLESS OTHERWISE NOTED. LAP SPLICES IN CONTINUOUS REINFORCING STEEL MUST CONFORM TO THE REQUIREMENTS OF ACI 318 FOR CLASS B TENSION LAP
SPLICES, UNLESS OTHERWISE NOTED.
7. MINIMUM CONCRETE COVER FOR REINFORCING STEEL IS NOT PERMITTED TO BE LESS THAN THE
REQUIREMENTS OF ACI 301. MINIMUM COVER MUST BE AS INDICATED, BUT NOT LESS THAN:
A. CONCRETE DEPOSITED AGAINST THE GROUND 75
B. CONCRETE EXPOSED TO EARTH OR WEATHER 50
C. INTERIOR BEAMS AND COLUMNS 40
D. INTERIOR SLABS AND WALLS 25
EXTERIOR WALLS AND ROOF SLAB ARE CONSIDERED EXPOSED TO WEATHER FOR COVER
REQUIREMENTS.
8. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK MUST HAVE A 90-DEGREE HOOK, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND HOOKS MUST CONFORM TO THE REQUIREMENTS OF ACI 318.
9. SUPPORT REINFORCING STEEL AND WELDED-WIRE REINFORCEMENT ON BAR SUPPORTS. SPACE BAR
SUPPORTS PER CRSI MANUAL OF STANDARD PRACTICE.
10. EMBEDDED ITEMS MUST BE PROPERLY PLACED, ACCURATELY POSITIONED, AND MAINTAINED SECURELY
IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
11. PROVIDE 12mm THICK PREMOLDED JOINT-FILLER STRIP (PJF) WHERE SLABS-ON-GRADE ABUT VERTICAL
SURFACES AND WHERE INDICATED.
12. REINFORCING STEEL MUST BE SPREAD AT SLEEVES, TIEBACKS, RECESSES, AND OTHER EMBEDDED ITEMS UNLESS OTHERWISE NOTED. REINFORCING MUST NOT BE CUT TO FACILITATE PLACEMENT OF EMBEDDED
ITEMS.
13. CONDUITS AND PIPES MUST NOT BE EMBEDDED LONGITUDINALLY WITHIN A SLAB OR WALL. CONDUIT OR PIPES PENETRATING A WALL OR SLAB MUST BE SLEEVED. SEE 'TYPICAL SLAB OR WALL OPENING' ON
SHEET SF503.
14. PLACEMENT OF MECHANICAL AND ELECTRICAL CONDUIT IN ELEVATED SLABS ON STEEL DECK IS NOT
PERMITTED.
15. PLACEMENT OF CONCRETE IS NOT PERMITTED UNTIL THE CONTRACTING OFFICER HAS INSPECTED
EMBEDDED WORK, INCLUDING REINFORCING STEEL.
16. EXPOSED CONCRETE EDGES MUST BE CHAMFERED 20mm OR AS INDICATED.
17. DO NOT PLACE ALUMINUM CONDUITS, PIPES, OR ACCESSORIES IN DIRECT CONTACT WITH CONCRETE
UNLESS COATED TO PREVENT ELECTROLYSIS.
18. PROVIDE CONSTRUCTION JOINTS IN MONOLITHIC CONCRETE POURS SO THAT THE QUALITY OF
PLACEMENT AND FINISH MEETS REQUIREMENTS OF THE CONTRACT DOCUMENTS.
19. HORIZONTAL CONSTRUCTION JOINTS IN HORIZONTALLY-ORIENTED MEMBERS SUCH AS BEAMS, SLABS, AND FOOTINGS ARE NOT PERMITTED. SUBMIT FOR APPROVAL THE LOCATION OF HORIZONTAL
CONSTRUCTION JOINTS IN VERTICALLY-ORIENTED MEMBERS SUCH AS WALLS AND COLUMNS. VERTICAL CONSTRUCTION JOINTS MUST BE MADE WITH BULKHEADS. REFER TO TYPICAL CONSTRUCTION JOINT
DETAILS ON SHEET SF502.
20. PENETRATIONS THROUGH ELEVATED SLABS MUST BE BLOCKED OUT PRIOR TO PLACING CONCRETE.;
CORING OF SLAB IS NOT PERMITTED WITHOUT PRIOR APPROVAL. REFER TO TYPICAL OPENING DETAILS
ON SHEET SF502 FOR REINFORCING REQUIREMENTS.
STRUCTURAL STEEL NOTES
1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS MUST BE IN
ACCORDANCE WITH THE AISC “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” (AISC 360) AND THE
AISC “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES” (AISC 303).
2. STRUCTURAL STEEL SHAPES ON THESE DRAWINGS ARE STANDARD AISC (ASTM A6M) SHAPES, INDICATED
WITH THEIR METRIC (SI) DESIGNATIONS.
3. STRUCTURAL STEEL FRAMING IS DESIGNED USING LRFD METHODOLOGY IN ACCORDANCE WITH AISC 360.
4. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL MUST BE IN ACCORDANCE WITH THE ABOVE-LISTED
AISC SPECIFICATION AND THE FOLLOWING:
A. SQUARE AND RECTANGULAR HSS ASTM A500, GRADE C, Fy = 345 MPa B. ROUND HSS ASTM A500, GRADE C, Fy = 345 MPa
C. WIDE-FLANGE SHAPES ASTM A992
D. PLATES, ANGLES, AND CHANNELS ASTM A36
E. HIGH-STRENGTH BOLTS ASTM F3125 GRADE A325 OR GRADE F1852
F. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36 (248 MPa)
G. THREADED ROD ASTM A36
H. STEEL HEADED STUD ANCHORS ASTM A29 AND AWS D1.1, TYPE B, Fu = 448 MPa
I. WELDING ELECTRODES, UON E70XX
J. STEEL DECK ATTACHMENT ELECTRODES E60XX
5. SHOP AND FIELD WELDING MUST BE BY CERTIFIED WELDERS AND MUST CONFORM TO AWS STANDARDS.
CURRENT AWS CERTIFICATIONS MUST BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE CONTRACTING
OFFICER.
6. BOLTED CONNECTIONS MUST USE HIGH-STRENGTH BOLTS WITH ASTM A563 HEAVY-HEX NUTS AND
ASTM F436 WASHERS, UNLESS OTHERWISE NOTED.
7. FIELD-CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE IS NOT PERMITTED WITHOUT PRIOR
APPROVAL OF STRUCTURAL ENGINEER OF RECORD. DO NOT CUT OR ENLARGE BOLT HOLES BY
FLAME-CUTTING IN THE FIELD.
8. DESIGN OF STRUCTURAL STEEL SHEAR CONNECTIONS IS DELEGATED TO THE CONTRACTOR'S SPECIALTY ENGINEER. REFER TO SHEET SF303 FOR TYPICAL CONNECTION DETAILS. WELDED TRUSS AND BRACED FRAME CONNECTIONS ARE DESIGNED HEREIN AND MUST BE COMPLETED BY THE STEEL DETAILER.
9. BOLTS IN BEARING-TYPE CONNECTIONS MUST BE PRETENSIONED USING TENSION-CONTROL (TC) BOLTS
OR DIRECT-TENSION INDICATOR (DTI) WASHERS IN ACCORDANCE WITH THE SPECIFICATIONS.
10. PARTIAL AND COMPLETE-JOINT-PENETRATION WELDS INDICATED ON THE STRUCTURAL DRAWINGS OR
SHOP DRAWINGS MUST BE INSPECTED WITH NON-DESTRUCTIVE TESTING.
11. FILLET WELD SIZES ARE INDICATED BY LEG DIMENSION. WELD DIAGRAMS AND SYMBOLS ARE PROVIDED IN
ACCORDANCE WITH AWS A2.4.
12. SUBMIT DRAWINGS OF, AND DESIGN CALCULATIONS FOR, ALTERNATE DETAILS AND MEMBER SPLICES FOR
APPROVAL PRIOR TO INSTALLATION.
13. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AND AS SPECIFICALLY APPROVED ON SHOP
DRAWINGS PRIOR TO FABRICATION.
14. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR STEEL ELEMENTS TO BE HOT-DIP
GALVANIZED PER ASTM A123.
15. PAINT STEEL EXPOSED TO EARTH WITH TWO COATS OF COAL TAR EPOXY. STEEL MEMBERS ENCASED IN CONCRETE (75mm MINIMUM COVER) NEED NOT BE COATED WITH COAL TAR EPOXY.
16. STRUCTURAL STEEL NOTES DO NOT APPLY TO DELEGATED DESIGN ITEMS WHICH ARE NOT PART OF THE
BUILDING STRUCTURE.
1. THE DESIGN, MANUFACTURING, ERECTION, AND ANCHORAGE OF COMPOSITE STEEL DECK MUST BE IN
ACCORDANCE WITH THE ANSI/SDI "STANDARD FOR COMPOSITE STEEL FLOOR DECK-SLABS".
2. COMPOSITE STEEL DECK MUST BE GALVANIZED G90 STEEL CONFORMING TO ASTM A653.
COMPOSITE STEEL DECK MUST BE 50mm DEEP. COMPOSITE STEEL DECK MUST HAVE THE FOLLOWING
MINIMUM SECTION PROPERTIES:
A. t = 0.909mm B. Ip= 558526 mm4/mm C. Sp= 18333 mm3/mm D. Sn= 18602 mm3/mm E. Fy= 345 MPa
COMPOSITE DECK MUST BE FASTENED TO THE SUPPORTING STRUCTURE WITH Ø16 PUDDLE WELDS, HEADED STUDS, OR APPROVED MECHANICAL FASTENERS AT A 36/4 PATTERN. SIDE LAP CONNECTIONS MUST BE MADE WITH #10 SELF-DRILLING SCREWS SPACED AT 300mm OC MAXIMUM BETWEEN SUPPORTS.
FASTEN DISCONTINUOUS SIDE OF DECK TO SUPPORTING STRUCTURE WITH Ø16 PUDDLE WELDS AT 300mm OC, UNLESS OTHERWISE NOTED.
3. STEEL DECK MUST BE CONTINUOUS FOR THREE SPANS MINIMUM. SINGLE AND 2-SPAN CONDITIONS MUST
BE CLEARLY INDICATED ON SHOP DRAWINGS.
4. COMPOSITE STEEL DECK IS DESIGNED AS UNSHORED CONSTRUCTION, UNLESS OTHERWISE NOTED.
5. CONSTRUCTION PHASE LOADS: COMPOSITE STEEL DECK IS DESIGNED TO SUPPORT, IN ADDITION TO THE DEAD WEIGHT OF UNCURED CONCRETE, A 1 kPa UNIFORM LIVE LOAD OR A 0.7 kN CONCENTRATED LOAD
AT ANY POINT. REFER TO ANSI/SDI C-2017 FOR CONSTRUCTION LOADING DIAGRAMS.
STEEL DECK NOTES
1. POST-INSTALLED ANCHORS MUST ONLY BE USED WHERE SPECIFIED IN THE CONSTRUCTION DOCUMENTS.
OBTAIN APPROVAL PRIOR TO USING POST-INSTALLED ANCHORS FOR MISSING OR MISPLACED CAST-IN-
PLACE ANCHORS OR FOR SUBSTITUTIONS.
2. POST-INSTALLED ANCHORS MUST BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S REQUIREMENTS (INCLUDING, BUT NOT LIMITED TO, DRILL BIT SIZE, PROPER CLEANING OF HOLES, INSTALLATION TORQUE, AND TEMPERATURE CONSTRAINTS).
3. CONCRETE SUBSTRATE MUST BE ASSUMED TO BE CRACKED.
4. SPACING AND EDGE DISTANCE FOR ANCHORS MUST NOT BE LESS THAN MINIMUM INDICATED.
5. ALL ANCHOR INSTALLATION PERSONNEL MUST BE TRAINED OR CERTIFIED BY THE ANCHOR
MANUFACTURER PRIOR TO INSTALLING ANCHORS.
6. ANCHOR INSTALLATION IS SUBJECT TO SPECIAL INSPECTION REQUIREMENTS.
7. CONFIRM THE ABSENCE OF REINFORCING STEEL BY DRILLING A Ø6 PILOT HOLE FOR EACH ANCHOR OR BY
NONDESTRUCTIVE METHODS. DO NOT CUT REINFORCING STEEL WITHOUT THE APPROVAL OF THE
STRUCTURAL ENGINEER OF RECORD.
8. ANCHORS USED IN EXTERIOR CONDITIONS MUST BE FURNISHED WITH A HOT-DIP GALVANIZED ZINC COATING COMPLYING WITH ASTM A153. ANCHORS USED IN INTERIOR CONDITIONS MUST BE FURNISHED
WITH A ZINC ELECTROPLATED COATING COMPLYING WITH ASTM B633.
9. CONCRETE ANCHORS:
A. MECHANICAL ANCHORS MUST COMPLY WITH ACI 355.2 AND ICC-ES AC193.
B. ADHESIVE ANCHORS MUST COMPLY WITH ACI 355.4 AND ICC-ES AC308. THREADED RODS MUST MEET THE REQUIREMENTS OF ASTM F1554 GRADE 36 AND BE GALVANIZED IN ACCORDANCE WITH ASTM A153.
C. GAS AND POWDER-ACTUATED FASTENERS MUST COMPLY WITH ICC-ES AC70.
D. REINFORCING STEEL POST-INSTALLED WITH STRUCTURAL ADHESIVE MUST COMPLY WITH ICC-ES
AC308.
POST-INSTALLED ANCHOR NOTES
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:3
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
S-002
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
S
TR
U C
T U
R A
L N
O
TE
S A
N D
L E
G E
N D
MSH
14124413
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
DPS
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
BAR SIZE
DEVELOPMENT LENGTH
CONCRETE f'c
Ø 10
25 and 30 MPa 35 MPa
370 350
Ld
BOTTOM BARS AND VERTICAL REINFORCEMENT
TOP BAR REINFORCEMENT
Ø 12 450 410
Ø 14 520 480
Ø 16 590 550
Ø 20 930 860
Ø 25 1160 1070
Ø 28 1300 1200
Ø 32 1480 1370
BAR SIZE
LAP SPLICE LENGTH
CONCRETE f'c
480 450
580 540
680 630
770 710
1200 1110
1500 1390
1690 1560
1930 1780
Ls
BAR SIZE
DEVELOPMENT LENGTH
CONCRETE f'c
Ld
BAR SIZE
LAP SPLICE LENGTH
CONCRETE f'c
630 580
750 700
880 810
1000 930
1570 1450
1960 1810
2190 2030
2500 2320
Ls Ldh Ldh
DEVELOPMENT OF
HOOKED BARS
185 175
CONCRETE f'c
BAR SIZE
225 205
240260
STANDARD HOOKS
Ø 10
Ø 12
Ø 14
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
Ø 10
Ø 12
Ø 14
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
Ø 10
Ø 12
Ø 14
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
25 and 30 MPa 35 MPa
25 and 30 MPa 35 MPa25 and 30 MPa 35 MPa
Ø 10
Ø 12
Ø 14
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
25 and 30 MPa 35 MPa
NOTES
1. PROVIDE REINFORCING IN ACCORDANCE WITH ACI 318.
TABLES ARE BASED ON Fy = 420 MPa.
2. ALL LENGTHS IN MILLIMETERS.
3. 'TOP BAR' IS DEFINED AS HORIZONTAL REINFORCING
PLACED SUCH THAT MORE THAN 300mm OF FRESH
CONCRETE IS PLACED BELOW THE BAR BEING DEVELOPED
OR SPLICED.
4. 'BOTTOM BAR' IS DEFINED AS HORIZONTAL REINFORCING
PLACED SUCH THAT LESS THAN 300mm OF FRESH
CONCRETE IS PLACED BELOW THE BAR BEING DEVELOPED
OR SPLICED.
5. WALL REINFORCING:
A. HORIZONTAL BARS MUST USE 'TOP BAR' LENGTHS.
B. FOR VERTICAL BARS, MULTIPLY TABULATED VERTICAL
BAR LAP SPLICE LENGTH BY 1.25.
6. LAP SPLICE LENGTHS INDICATED ARE CLASS B.
7. MINIMUM LENGTHS AND BENDS INDICATED, BENDS MUST
COMPLY WITH ACI 318.
8. WELDED SPLICES ARE NOT PERMITTED.
NOT TO SCALE
DETAILS OF CONCRETE REINFORCEMENT
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:3
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
S-003
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
S
TR
U C
T U
R A
L N
O
TE
S
MSH
14124414
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
DPS
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
1. FOUNDATION UNDERCUT REQUIREMENTS ARE BASED ON THE GEOTECHNICAL
INVESTIGATION.
2. UNDERCUT AND BACKFILL BENEATH SHALLOW FOUNDATIONS IN
ACCORDANCE WITH UNDERCUT SCHEDULE. AFTER EXCAVATING TO THE
BOTTOM OF THE FOUNDATION, UNDERCUT THE SUBGRADE BY THE
SCHEDULED DEPTH AND BACKFILL TO THE FOUNDATION BEARING ELEVATION
WITH APPROVED UNDERCUT BACKFILL MATERIAL.
3. THE INDICATED UNDERCUT IS MINIMUM REQUIRED AND DOES NOT ELIMINATE
THE NEED FOR ADDITIONAL UNDERCUT WHEN UNSUITABLE SOILS ARE
ENCOUNTERED.1 1
A B C D
12 12
13 13
32900
20000 2900 10000 1000
MATCHLINE
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U -1
U -1
U -1
U -1
U-1
U-1 U-1
U-1
U -1
U -1
U -1
U -1
U-1 U-1
U -2
U-2
U -2
U-2
U -2
U-1
E
INCREASE WIDTH OF
EXCAVATION, UNDERCUT,
AND BACKFILL MATERIAL BY
150 TOTAL FOR EVERY 300
OF UNDERCUT DEPTH
COLUMN
OR WALL
FOOTING
[SEE PLAN]
TOF
UNDERCUT
DEPTH
EXCAVATION
SLOPE AS
SPECIFIED
FOUNDATIONS MAY
BE EARTH-FORMED
BACKFILL MATERIAL
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:3
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB100
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
F O
U N
D A
T
IO
N U
N D
E R
C U
T P
LA
N
MSH
14124415
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
1:200 0 5 10 15 20m
GRAPHIC SCALE(S)
FOUNDATION UNDERCUT PLAN NOTES
KEY PLAN
# KEY NOTES
A
B
UNDERCUT SCHEDULE
MARK PATTERN UNDERCUT DEPTH
U-1 300
U-2 NONE
1 : 200 A1
FOUNDATION UNDERCUT PLAN
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DPS
NOT TO SCALE
TYPICAL FOUNDATION UNDERCUT
1 1
A B C D
12 12
13 13
32900
20000 2900 10000 1000
MATCHLINE
C1
SF301
SB702
A1
TYP
10500
TYP
10500
E 1. TOP OF FOOTING ELEVATION = [-1100], REFERENCED TO FINISHED FLOOR
DATUM ELEVATION [000], UNLESS OTHERWISE NOTED.
2. TOP OF SLAB-ON-GRADE ELEVATION IS FINISHED FLOOR DATUM
ELEVATION [000]. SEE CIVIL DRAWINGS FOR ACTUAL FINISHED FLOOR
ELEVATION. SLAB-ON-GRADE ELEVATIONS THAT VARY FROM THE DATUM
ARE NOTED: TOSL [±XXX].
3. GRID LINES SHOWN AS SOLID LINES ( ) ARE TO OUTSIDE FACE OF
CONCRETE WALL.
4. GRID LINES SHOWN AS CENTERLINES ( ) ARE TO COLUMN CENTERLINE.
5. COLUMN FOOTINGS ARE INDICATED "Fx". WALL FOOTINGS ARE INDICATED "WFx". REFER TO "FOOTING SCHEDULE" ON SHEET SB501 FOR SIZE AND
REINFORCING.
6. FOUNDATION TIE BEAMS ARE INDICATED "TBx". REFER TO "FOUNDATION
TIE BEAM REINFORCING AND SCHEDULE" ON SHEET SB501 FOR SIZE AND
REINFORCING.
7. CONCRETE COLUMNS ARE INDICATED "Cx". REFER TO "CONCRETE COLUMN
SCHEDULE" AND "TYPICAL CONCRETE COLUMN DETAIL" ON SHEET SF501.
8. CONCRETE WALLS ARE INDICATED "Wx". REFER TO "TYPICAL CONCRETE
WALL DETAIL" AND "CONCRETE WALL SCHEDULE" ON SHEET SF502 FOR SIZE
AND REINFORCING. CONCRETE WALLS ARE W1, UNLESS OTHERWISE NOTED.
B C
TOSL
[-900]
TOSL
[-730]
TOSL
[-770]
TOSL
[-800]
TOSL
[-695]
TOSL
[-800]
TOSL
[-770]
TOSL
[-730]
TOSL
[-750]
TOSL
[-720]
TOSL
[-680]
TOSL
[-630]
TOSL
[-640]
TOSL
[-620]
TOSL
[-840]
TOSL
[-790]
TOSL
[-820]
TOSL
[-840]TOSL
[-900]
TOSL
[-820]
TOSL
[-790]
TOSL
[-720]
TOSL
[-750]
TOSL
[-630]
TOSL
[-680]
TOSL
[-900]
TOSL
[-900]
TOSL
[-900]
TOSL
[-900]
TOSL
[-900]
TOSL
[-590]
TOSL
[-610]
TOSL
[-630]
TOSL
[-620]
TOSL
[-1500]
TOSL
[-1500]
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:3
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB101
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
F O
U N
D A
T
IO
N P
LA
N
O
V E
R A
LL
MSH
14124416
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
1:200 0 5 10 15 20m
GRAPHIC SCALE(S)
FOUNDATION PLAN NOTES
KEY PLAN
# KEY NOTES
A
B
1 : 200 A1
FOUNDATION PLAN - OVERALL
DPS
1 : 200 A3
PARTIAL PLAN AT
BASE OF TRENCH
1 GENERATOR EQUIPMENT PAD, REFER TO TYPICAL DETAIL ON SHEET SB301.
COORDINATE DIMENSIONS WITH EQUIPMENT PROVIDED.
2 UTILITY TRENCH. REFER TO PARTIAL PLAN THIS SHEET FOR TRENCH BASE
ELEVATIONS.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
32900
20000 2900 10000
MATCHLINE
SB103
5400 1750 2450
WF1.5 WF1.2
W F
1.
W F
1.
W F
1.
W F
1.
WF1.0
WF1.0
W F
1.
W F
2.
C1
C1
C1
C1
C1
C2
W2
W
W2
W
W
W1
(TYP, UON)
W
W
C1
C1
C1
C1
C1
C2
C1
SB301
C1
SB301
C1
SB301
TO
F
[-1300]
TO
F
[-1100]
TO
F
[-1500]
S F
S F
TO
F
[-1500]
TO
F
[-1
0]
TO
F
[-1
0]
TO
F
[-1
0]
S F
S F
TO
F
[-1300]
TO
F
[-1100]
TO
F
[-1500]
TO
F
[-1500]
S F
S F
TO
F
[-1
0]
TO
F [-1
0]
TO
F
[-1
0]
S F
S F
T O
F
[-1800]
TO
F
[-1
0]
TO
F
[-1
0]
T O
F
[-1500]
TO
F
[-1
0]
TO
F
[-1
0]
TOF
[-1500]
SF
1367 1383
600 4800
4 TYP OF 4
2750 2967
S F
TOF
[-1800]
F101
F101
F101
SF
TOF
[-1300]
TOF
[-1100]
767 600
W1
W1 W1
F
W F
2.
W F
2.
W F
2.
REFER TO SHEET SB101 FOR FOUNDATION PLAN NOTES, TYPICAL UNLESS
OTHERWISE NOTED.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:4
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB102
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
F O
U N
D A
TI
O
N P
LA
N
A
R E
A A
MSH
14124417
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
1 : 100 A1
FOUNDATION PLAN - AREA A
A
B
DPS
1 GENERATOR EQUIPMENT MAT, REFER TO TYPICAL DETAIL ON SHEET SB301
AND SLAB-ON-GRADE SCHEDULE ON SHEET SB104. COORDINATE DIMENSIONS
WITH EQUIPMENT PROVIDED.
2 CONCRETE PIER 'CP1', TOP OF CONCRETE ELEVATION = [+100]
3 CONCRETE PIER 'CP2', TOP OF CONCRETE ELEVATION = [+100]
4 2000Ø x100 THICK INTERIOR EQUIPMENT PAD, TOP OF CONCRETE
ELEVATION = [-800]
5 UNDERGROUND PIPE
6 600 THICK FOUNDATION MAT FOR EXHAUST STACKS AND EQUIPMENT
PLATFORMS
7 PIPE SLEEVES THROUGH WALL, COORDINATE WITH FUEL LINES
8 SLAB-ON-GRADE WITHIN TANK ROOMS, REFER TO SLAB-ON-GRADE PLAN AND
SCHEDULE ON SHEET SB104.
9 2000Ø x500 THICK INTERIOR EQUIPMENT PAD, TOP OF CONCRETE
ELEVATION = [-800]
1:100 0 9 10m87654321
GRAPHIC SCALE(S)
FOUNDATION PLAN NOTES
KEY PLAN
# KEY NOTES
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
A B C
12 12
13 13
33900
20000 2900 11000
MATCHLINE
SB102
T B
F2.75 [-1500]
F2.5 [-1500]
F2.5 [-1500]
5400 1750 2075
WF1.2
WF1.0
W F
1.
W F
1.
WF1.5
W F
1.
W F
2.
C2
C1
C1
C1
C1
C1
W1
(TYP, UON)
W
W
W2
W
W2
W2
C1
C1
C1
C2
C1
C1
W F
1.
C1
SB301
C1
SB301
1367 1383
TOF
[-1500]
SF
TO
F
[-1500]
TO
F
[-1300]
TO
F
[-1100]
S F
S F
S F
S F
TO
F
[-1
0]
TO
F
[-1
0]
T O
F
[-1300]
T O
F
[-1100]
S F
S F
4 TYP OF 5
TOF
[-1300]
TOF
[-1100]
2750 2967
F101
F101
SF
SF
TOF
[-1800]
7500 1000
C2
SB301
600 4800
E
W F
1.
SF
SF
SF
SF
TOF
[-1500]
TOF
[-1100]
TOF
[-1900]
TOF
[-1500]
TOF
[-1100]
TOF
[-1100]
TOF
[-1900]
W F
1.
WF1.0
W1
W1
W1
W1(TYP)
W
W F
1.
W F
1.
W
W2
F
W F
2.
WF2.0
WF1.5 [-1500]
W F
2.
SF
REFER TO SHEET SB101 FOR FOUNDATION PLAN NOTES, TYPICAL UNLESS
OTHERWISE NOTED.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:4
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB103
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
F O
U N
D A
T
IO
N P
LA
N
A
R E
A B
MSH
14124418
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
1 : 100 A1
FOUNDATION PLAN - AREA B
DPS
1 GENERATOR EQUIPMENT MAT, REFER TO TYPICAL DETAIL ON SHEET SB301
AND SLAB-ON-GRADE SCHEDULE ON SHEET SB104. COORDINATE DIMENSIONS
WITH EQUIPMENT PROVIDED.
2 CONCRETE PIER 'CP1', TOP OF CONCRETE ELEVATION = [+100]
3 CONCRETE PIER 'CP2', TOP OF CONCRETE ELEVATION = [+100]
4 2000Ø x100 THICK INTERIOR EQUIPMENT PAD, TOP OF CONCRETE
ELEVATION = [-800]
5 UNDERGROUND PIPE
6 600 THICK FOUNDATION MAT FOR EXHAUST STACKS AND EQUIPMENT
PLATFORMS
7 PIPE SLEEVES THROUGH WALL, COORDINATE WITH FUEL LINES
8 SLAB-ON-GRADE WITHIN TANK ROOMS, REFER TO SLAB-ON-GRADE PLAN AND
SCHEDULE ON SHEET SB104.
9 2000Ø x500 THICK INTERIOR EQUIPMENT PAD, TOP OF CONCRETE
ELEVATION = [-800]
1:100 0 9 10m87654321
GRAPHIC SCALE(S)
FOUNDATION PLAN NOTES
KEY PLAN
# KEY NOTES
A
B
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
12 12
13 13
32900
20000 2900 10000 1000
S-150
S-2200
S-2200
S-2200
S-150
S-2200
S-2200
S-2200
S-2200
S-300A
S-2200
S-2200
S-2200
S-300A
S-200
S-200
MATCHLINE
S-300B [-900]
S-300B [-900]
C1
SF301
SB702
A3
STEEL BAR
GRATING, TYP
E
S-200 [-1300]
S-200 [-1300]
1. TOP OF SLAB-ON-GRADE ELEVATION IS FINISHED FLOOR DATUM
ELEVATION [000]. REFER TO CIVIL DRAWINGS FOR ACTUAL FINISHED FLOOR
ELEVATION. SLAB-ON-GRADE ELEVATIONS THAT VARY FROM THE DATUM ARE
NOTED: TOSL [±XXX].
2. TOP OF GRATING ELEVATION = [000], UNLESS OTHERWISE NOTED
3. GRID LINES SHOWN AS SOLID LINES ( ) ARE TO OUTSIDE FACE OF
CONCRETE WALL.
4. GRID LINES SHOWN AS CENTERLINES ( ) ARE TO COLUMN CENTERLINE.
5. CONSTRUCT SLABS-ON-GRADE WITH THE THICKNESS, REINFORCING,
AND JOINT DOWELS (WHERE APPLICABLE) AS SCHEDULED ON THIS SHEET.
CAST SLAB-ON-GRADE OVER CONTINUOUS VAPOR RETARDER, OVER
200mm (MINIMUM) OF POROUS FILL. REFER TO SHEET SB502 FOR
SLAB-ON-GRADE DETAILS.
A. AT "GENERATOR MAT" TYPE FOUNDATION SLABS, PROVIDE MONOLITHIC,
REINFORCED CONCRETE EQUIPMENT SLABS FLUSH WITH
SLAB-ON-GRADE. CONSTRUCT GENERATOR MATS ON COMPACTED
SUBGRADE AND/OR STRUCTURAL FILL PREPARED IN ACCORDANCE WITH
BUILDING FOUNDATION REQUIREMENTS.
B. AT "TANK SLAB" TYPE SLAB-ON-GRADE, PROVIDE REINFORCED SLAB
WITHOUT JOINTS BETWEEN BONDING WALLS.
C. AT “ADMIN WING” TYPE SLAB-ON-GRADE, PROVIDE STANDARD SAWED
CONTRACTION JOINTS AND KEYED CONSTRUCTION JOINTS.
6. SLAB JOINT LAYOUT IS INDICATED ON PLAN. JOINTS MAY BE CONTRACTION
JOINTS OR CONSTRUCTION JOINTS, AS NEEDED TO FACILITATE CONCRETE
PLACEMENT. SLAB JOINT LAYOUT MAY BE AUGMENTED OR MODIFIED AS
NEEDED TO FACILITATE CONCRETE PLACEMENT.
7. REFER TO FOUNDATION PLANS FOR CONCRETE COLUMN TYPES.
8. REFER TO FOUNDATION PLANS FOR CONCRETE WALL TYPES.
9. REFER TO ARCHITECTURAL DRAWINGS FOR DOOR AND WINDOW OPENINGS
IN WALLS. COORDINATE WITH THE REQUIREMENTS OF OTHER SYSTEMS FOR
WALL PENETRATIONS.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:4
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB104
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
S
LA
B -O
N -G
R A
D E
P
LA
N
O V
E R
A
LL
MSH
14124419
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
1:200 0 5 10 15 20m
GRAPHIC SCALE(S)
SLAB-ON-GRADE PLAN NOTES
KEY PLAN
A
B
SLAB-ON-GRADE SCHEDULE
MARK PATTERN TYPE THICKNESS REINFORCING DOWEL JTS
S-150 ADMIN WING 150 Ø12 AT 300 OC EW ---
S-200 ADMIN WING 200 Ø12 AT 300 OC EW, T&B ---
S-300A ENGINE ROOM 300 Ø12 AT 300 OC EW, T&B YES
S-300B TANK SLAB 300 Ø16 AT 150 OC EW, T&B ---
S-2200 GENERATOR MAT 2200 Ø25 AT 150 OC EW, 3 MATS ---
1 : 200 A1
SLAB-ON-GRADE PLAN - OVERALL
DPS
STEEL BAR GRATING SCHEDULE
MARK
MAIN BAR SIZE AND
SPACING
CROSS BAR
SPACING DESIGN LIVE LOAD TREATMENT REMOVABLE
G1 102x10 AT 24 OC 102 OC 12 kPA, 29 kN WHEEL GALVANIZED YES
G2 38x3 AT 30 OC 102 OC 4.8 kPA GALVANIZED NO
G3 38x3 AT 30 OC 102 OC 4.8 kPA GALVANIZED YES
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
REFER TO SHEET SB104 FOR SLAB-ON-GRADE PLAN NOTES, TYPICAL UNLESS
OTHERWISE NOTED.
1 1
A B C D
C1
SB301
A1
SB301
32900
20000 2900 10000
MATCHLINE
SB106
5400 1750 2450 3150
1TYP
150, TYP
150, TYP
C1
SB301
C1
SB301
4 TYP SB105
C4 TYP
OF 5
4TYP
B1
SB301
B2
SB301
B1
SB301
A2
SB301
B C
400 1800 400 300
NOTE #2
NOTE #2
0 N O
TE
N O
TE
W200X15
W200X15
W
0X
W
0X
W
0X
W
0X
L76X76X6.4
(TYP OF 4)
E
O D
, T Y
P
NOTES:
1. TOP OF STEEL ELEVATION FOR MEMBERS
SUPPORTING DECK/GRATING = [-38].
2. DIMENSION IS TO EDGE OF DECK/GRATING
AND FACE OF ANGLE. COORDINATE WITH
TANK DIMENSIONS.
A5
SB301
B5
SB301
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:4
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB105
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
S
LA
B -O
N -G
R A
D E
P
LA
N
A R
E A
A
MSH
14124420
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
A
B
1:25 0 0.5 2.5m1 1.5 2
1:100 0 9 10m87654321
GRAPHIC SCALE(S)
SLAB-ON-GRADE PLAN NOTES
KEY PLAN
# KEY NOTES
1 : 100 A1
SLAB-ON-GRADE PLAN - AREA A
1 : 25 C4
PLAN DETAIL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DPS
1 STEEL BAR GRATING TYPE G1. REFER TO "STEEL BAR GRATING SCHEDULE" ON
SHEET SB104. REFER TO SB301 DETAILS FOR GRATING BEARING DETAILS AND
EXTENTS.
2 STEEL BAR GRATING TYPE G3. REFER TO "STEEL BAR GRATING SCHEDULE" ON
SHEET SB104.
3 HSS127X76.4X6.4 (LSV), TOP OF STEEL ELEVATION = [-102]
4 L127X76X6.4 (LLV), TOP OF STEEL ELEVATION = [-38]. SEE SECTION B5 ON SB301.
5 EMBEDDED ANGLE AT OVERHEAD DOOR SILL, REFER TO TYPICAL DETAIL ON
SHEET SB502.
6 HSS101.6X101.6X6.4 EXHAUST SUPPORT POST, WITH BASE PLATE BP2. TYPICAL
AT EACH GENSET.
7 W200X52 EXHAUST AND FILTER SUPPORT POST, WITH BASE PLATE BP1.
8 HSS203.2x203.2 WITH BASE PLATE BP3
12 12
13 13
33900
20000 2900 11000
MATCHLINE
SB105
7500 1000
5400 1750 2075
1TYP
150, TYP
150, TYP
C1
SB301
C2
SB301
C1
SB301
A1
SB301
SB105
C4 TYP
OF 6
4TYP
4 TYP
B1
SB301
B2
SB301
C2
SB301
A2
SB301
SIM
E
REFER TO SHEET SB104 FOR SLAB-ON-GRADE PLAN NOTES, TYPICAL UNLESS
OTHERWISE NOTED.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:5
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB106
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
S
LA
B -O
N -G
R A
D E
P
LA
N
A R
E A
B
MSH
14124421
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
1 : 100 A1
SLAB-ON-GRADE PLAN - AREA B
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DPS
1 STEEL BAR GRATING TYPE G1. REFER TO "STEEL BAR GRATING SCHEDULE" ON
SHEET SB104. REFER TO SB301 DETAILS FOR GRATING BEARING DETAILS AND
EXTENTS.
2 STEEL BAR GRATING TYPE G3. REFER TO "STEEL BAR GRATING SCHEDULE" ON
SHEET SB104.
3 HSS127X76.4X6.4 (LSV), TOP OF STEEL ELEVATION = [-102]
4 L127X76X6.4 (LLV), TOP OF STEEL ELEVATION = [-38]. SEE SECTION B5 ON SB301.
5 EMBEDDED ANGLE AT OVERHEAD DOOR SILL, REFER TO TYPICAL DETAIL ON
SHEET SB502.
6 HSS101.6X101.6X6.4 EXHAUST SUPPORT POST, WITH BASE PLATE BP2. TYPICAL
AT EACH GENSET.
7 W200X52 EXHAUST AND FILTER SUPPORT POST, WITH BASE PLATE BP1.
8 HSS203.2x203.2 WITH BASE PLATE BP3
1:100 0 9 10m87654321
GRAPHIC SCALE(S)
SLAB-ON-GRADE PLAN NOTES
KEY PLAN
# KEY NOTES
A
B
VAPOR RETARDER
SLAB, SEE PLAN
AND SCHEDULE
12 PJF
[SEE PLAN]
TOSL
GRADE VARIES
CONT 50x100 KEY
WALL FOOTING,
SEE PLAN AND
SCHEDULE
UNDERCUT FOOTING
SUBGRADE AND BACKFILL,
SEE SHEET S100.
CONCRETE WALL,
SEE PLAN AND
SCHEDULE
GRID
WALL VERTICAL REINFORCING
AND DOWELS ARE 'SPECIAL
SEISMIC REINFORCING' (TYP)
DOWELS WITH
STD 90° HOOK
SLAB, SEE PLAN
AND SCHEDULE
50 CLR
C
LR
C
LR
UTILITY TRENCH
SEE PLAN 300
Ø16 AT 300 OC, EACH WAY,
TOP AND BOTTOM,
HOOK AS SHOWN
GRATING, SEE PLAN
AND SCHEDULE
Ø12 AT 300 OC,
EACH WAY, EACH FACE,
HOOK AS SHOWN (TYP) 50 CLR 50 CLR
25 ISOLATION
JOINT (TYP)
[SEE PLAN]
TOSL
[SEE PLAN]
TOSL VARIES
SLAB, SEE PLAN
AND SCHEDULE
SEMIRIGID EPOXY
JOINT FILLER (TYP)
CONT 50x100 KEY (TYP)
SB301
C3
GRATING SPAN
UTILITY TRENCH
SEE PLAN300
[SEE PLAN]
TOSL
MIN [-900]
TOSL VARIES
[-1200]
BOC
50 CLR 50 CLR
CONT 50x100 KEY (TYP)
SLAB, SEE PLAN
AND SCHEDULE
Ø12 AT 300 OC,
EACH WAY, EACH FACE,
HOOK AS SHOWN (TYP)
Ø16 AT 300 OC,
EACH WAY,
TOP AND BOTTOM,
HOOK AS SHOWN
GRATING, SEE PLAN
AND SCHEDULE
STD 180° HOOK
ON SLAB BARS (TYP)
T Y
P
WATERPROOFING,
SEE ARCH DWGS
CONT WATERSTOP (TYP)
VAPOR RETARDER
0, TYP
SB301
C3
GRATING SPAN
[SEE PLAN]
TOSL
MIN [-900]
TOSL VARIES
[-1200]
BOC
HSS, SEE PLAN
T Y
P
FACE OF WALL BEYOND
NOTE:
REFER TO FOR
DETAILS NOT NOTED.
GRATING, SEE PLAN
AND SCHEDULE (TYP)
UTILITY TRENCH
SEE PLAN 300
SB301
C4
SLAB, SEE PLAN
AND SCHEDULE
B1/SB301
GRATING SPAN
GRATING, SEE PLAN
AND SCHEDULE
CONT L89x89x6.4 WITH Ø10x102 LONG HEADED
STUDS AT 600 OC
CONT PL- 10x102
GALVANIZE PLATE AND
ANGLE ASSEMBLY
GRATING, SEE PLAN
AND SCHEDULE (TYP)
HSS, SEE PLAN
CONT ANGLE,
SEE C3/SB301
A
A
GRATING, SEE PLAN
AND SCHEDULE
L89x89x6.4 x150, GALVANIZED, WITH (2) Ø10x102 LONG
HEADED STUDS
150 WIDE x 89 DEEP
POCKET IN CONCRETE
WALL BEYOND
HSS, SEE PLAN
SECTION 'A-A'
SLAB, SEE PLAN
AND SCHEDULE
12 PJF (TYP)
[SEE PLAN]
TOSL
CONCRETE WALL,
SEE PLAN AND
SCHEDULE
VAPOR RETARDER
UNDERCUT FOOTING
SUBGRADE AND BACKFILL,
SEE SHEET S100.
CONT 50x100 KEY
CONT 12 PJF, FULL HEIGHT
BETWEEN WALLS
GRATING AND STEEL
BEAM, SEE PLAN
CONCRETE WALL
AND SLAB, SEE PLAN
WALL FOOTING,
SEE PLAN AND
SCHEDULE
GRID
[-150]
TOW
[-900]
TOC
25 ISOLATION
JOINT (TYP)
UNDERCUT AND BACKFILL,
SEE SHEET SB100
[SEE PLAN]
TOSL
SLAB, SEE PLAN
AND SCHEDULE
SEE PLAN
VAPOR RETARDER
GENERATOR EQUIPMENT.
COORDINATE ANCHORAGE
WITH GENERATOR SUPPLIER.
GENERATOR MAT,
SEE PLAN AND SCHEDULE
50 CLR
C
LR
C
LR75
0, TYP
50 CLR
STD 90° HOOK
EACH END (TYP)
CONT L127x76x7.9 (LLV), GALVANIZED
[SEE PLAN]
TOS
GRATING, SEE PLAN
AND SCHEDULE
CONCRETE WALL,
SEE PLAN
GALVANIZED Ø12x102
EXPANSION ANCHOR
AT 1000 OC AND 200 FROM
ANGLE ENDS
L76x76x6.4 x76 LONG
CLIP, GALVANIZED
(TYP, EACH SIDE OF BEAM)
[SEE PLAN]
TOS
GRATING, SEE PLAN
AND SCHEDULE
(1) Ø12x102 EXPANSION
ANCHOR, GALVANIZED
(TYP, EACH CLIP ANGLE)
3 SIDES,
TYP
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:5
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB301
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
F O
U N
D A
TI
O
N S
E C
T
IO
N S
MSH
14124422
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
1 : 20 C1
SECTION
1 : 20 A1
SECTION
1:10
0 0.5 1m
1:20 0 2m0.5 1 1.5
GRAPHIC SCALE(S)
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DPS
1 : 20 B1
SECTION
1 : 20
B2
SECTION
1 : 10 C3
DETAIL
1 : 10
C4
DETAIL
1 : 20 C2
SECTION
1 : 20 A2
SECTION
1 : 10 B5
SECTION
1 : 10 A5
SECTION
'A' AND
'C' BARS
CONT
'D' BARS
L
C O
N T
PLAN AT WALL
WALL
'C' BARS
'B' BARS
PLAN AT COLUMN
COLUMN,
WALL SIMILAR
W
L
SECTION
'B' BARS'A' BARS
'D' BARS
W
T
W
'C' BARS
'B' BARS
'D' BARS
'A' BARS
BOTTOM REINFORCING
CONTINUOUS
THROUGH JOINT
TIE BAR EACH SIDE OF
CONSTRUCTION JOINT
C
LR
, T
O P
(3) Ø16x1200, TOP
CENTERED ON JOINT
S E
E P
L A N
T
PREVIOUS POUR NEW POUR
T/
T/
T/
100 100
CONTINUOUS WALL
FOOTING, SEE PLAN
AND SCHEDULE
PVC OR GALV STEEL
PIPE SLEEVE.
DIA = PIPE DIA + 50 MIN
300 MIN, TYP
200 MIN
10 MPa LEAN CONCRETE, WIDTH EQUAL TO
CONTINUOUS FOOTING WIDTH
M
IN
M A
X
STIRRUP
C
LR
SECTION
TOP BARS
BOTTOM BARS CONCRETE FOOTING.
POUR FOOTINGS AND TIE
BEAMS MONOLITHICALLY.
(REINFORCING NOT
SHOWN FOR CLARITY.)
STD 90° HOOK
C
LR
D
W
75 CLR 50
FOR SIZE AND SPACING
STIRRUPS, SEE SCHEDULE 50
LOCATE LAP SPLICES
(IF USED) AT THIRD-SPAN
OF TIE BEAM
ELEVATION
75 CLR75 CLR
SIDE BARS
(2x STEP DEPTH)
STEP LENGTH
300 MIN
'B' BARS,
SEE SCHEDULE
'Z' BARS SAME SIZE AND
NUMBER AS CONTINUOUS
FOOTING REINFORCING,
BEND AS SHOWN
'A' BARS,
SEE SCHEDULE
SEE S-003
LAP SPLICE, TYP
200 MIN,
400 MAX
'D' BARS,
SEE SCHEDULE
'C' BARS,
SEE SCHEDULE
EXTEND VERTICAL LEG OF
'B' AND 'D' BARS AT STEP.
LAP BARS 300 MIN. (TYP)
75 CLR,
TYP
NUT AND WASHER
50 NON-SHRINK
NON-METALLIC
GROUT
CL COL, BPL,
AND FTG, UON
[SEE PLAN]
TOF
BASE PLATE AND ANCHOR ROD SCHEDULE
ANCHOR RODS
'P
'L
A
TYPE ROD
DIAMETER
BASE PLATE,
SEE SCHEDULE
'A-A'
38 38
CL COL
AND BPL
E Q
E Q
EQ EQ
B /2
B /2
N/2 N/2
BP3
TYP
LEVELING NUT
AND WASHER (TYP)
ANCHOR ROD WITH
HEAVY HEX NUT (TYP).
SEE SCHEDULE.
EMBEDMENT
'L'
PROJECTION
'P' (MIN)
20 300 125
BP2 12 90 50
BP1 20 140 50
NOTES
POST-INSTALLED ANCHORS TO SLAB
POST-INSTALLED ANCHORS TO SLAB
CAST-IN-PLACE ANCHORS
CAST-IN-PLACE ANCHORS
CL COL AND
BPL, UON
[SEE PLAN]
TOP OF SLAB
BASE PLATE,
SEE SCHEDULE
POST-INSTALLED ANCHORS
MECHANICAL EXPANSION
ANCHOR SYSTEM
A A A
BASE PLATE
THICKNESS
't'
LENGTH
'N'
WIDTH
'B'
20360360
12250250
12250250
TIE
SECTION
B
WCONCRETE
FOOTING, SEE PLAN
[SEE PLAN]
TOP OF PIER
[SEE PLAN]
TOF
3 TIES AT 50 OC
CONCRETE PIER, SEE
SCHEDULE FOR SIZE AND
REINFORCING
STD 90° HOOK (TYP)
0, TYP
CONCRETE SLAB
SEE TYPICAL ANCHOR ROD
AND BASE PLATE DETAIL ON
SHEET SB501
CL COL, PIER
AND FTG, UON
1/2" PREMOLDED
JOINT FILLER ALL
AROUND PIER (TYP)
ELEVATION
20 CHAMFER (TYP)
CONCRETE PIER SCHEDULE
CP2 3600 3600 (64) Ø20
CP1 600 600 (8) Ø25 Ø12 AT 200
MARK SIDE 'B' SIDE 'W'
VERTICAL
REINFORCING
TIE
REINFORCING
Ø12 AT 200
W F
2.
W F
1.
F102
'A AND 'C' BARS,
SEE SCHEDULE
'B' AND 'D' BARS,
SEE SCHEDULE
NOT TO SCALE
TYPICAL FOOTING DIAGRAM
NOT TO SCALE
TYPICAL CONCRETE
FOOTING CONSTRUCTION JOINT
FOOTING SCHEDULE
MARK
DIMENSIONS REINFORCING
NOTESW L T 'A' BARS 'B' BARS 'C' BARS 'D' BARS
F2.5 2500 2500 450 (8) Ø20 (8) Ø20 - -
F2.75 2750 2750 450 (10) Ø20 (10) Ø20 - -
F101 5717 8800 800 (15) Ø25 (32) Ø25 (15) Ø20 (32) Ø20
F102 4150 1150 400 (15) Ø20 Ø20 AT 300 (15) Ø20 Ø20 AT 300 SEE PLAN DETAIL THIS SHEET
WF1.0 1000 CONT 400 (4) Ø20 Ø16 AT 300 - -
WF1.2 1200 CONT 500 (5) Ø20 Ø16 AT 300 (5) Ø16 Ø16 AT 300
WF1.5 1500 CONT 600 (5) Ø20 Ø20 AT 300 (5) Ø20 Ø20 AT 300
WF2.0 2000 CONT 600 (7) Ø20 Ø20 AT 300 (7) Ø20 Ø20 AT 300
NOT TO SCALE
TYPICAL PIPE SLEEVE BENEATH FOOTING
NOT TO SCALE
TYPICAL CONCRETE TIE BEAM REINFORCING
TIE BEAM SCHEDULE
MARK
DIMENSIONS REINFORCING
NOTESW D TOP BARS BOTTOM BARS SIDE BARS STIRRUPS
TB1 600 450 (3) Ø20 (3) Ø20 (2) Ø20 Ø10 AT 200
NOT TO SCALE
TYPICAL STEPPED FOOTING
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
A
AS NOTED
1643338
A T
LA
N
T
IC
D E
S
IG
N A
N D
C O
N S
T R
U C
T
/1 /2
:5
:5
P
M B
IM
/P
E le c tr ic a l P o w e r
P la n t F
D A
/8
P
E le c t P w r
P ln t F
D A
S
.r v t
SB501
P -3
/P
-3 E
L E
C T
R
IC
A L P
O W
E R
P L A
N T
TY
P
IC
A
L F
O U
N D
A
TI
O N
D E
T A
IL
S
MSH
14124423
PAA SMS
JWH/SCN
D
JI
B O
U T
I, D
JI
B
O U
T I
C A
M P
L E
M O
N N
IE
R
RICHARD STEPHENS
JTW
DPS
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
NOTES:
1. PROVIDE STANDARD 90-DEGREE HOOKS ON BARS TERMINATING WITHIN A FOOTING, TYPICAL.
2. PROVIDE UNIFORMLY SPACED REINFORCING BARS, UNLESS OTHERWISE NOTED.
NOT TO SCALE
TYPICAL BASE PLATE AND ANCHOR ROD
NOT TO SCALE
TYPICAL CONCRETE PIER
NOT TO SCALE
PLAN DETAIL -
FOOTING F102
50 CLR
(2) Ø12 x1200
AT MID-DEPTH
RE-ENTRANT
CORNER
SLAB REINFORCEMENT,
SEE PLAN
CONCRETE
SLAB-ON-GRADE
VAPOR RETARDER
[SEE PLAN]
TOSL
T
C
LR
POROUS FILL
SAWCUT JOINT, DEPTH
EQUAL TO 1/4 OF
SLAB THICKNESS
[SEE PLAN]
TOSL
T
NOTE:
SEE ARCHITECTURAL
DRAWINGS FOR EXACT
LOCATION OF DEPRESSION.
3mm RADIUS
TOOLED EDGE
CONCRETE
SLAB-ON-GRADE
SEE ARCH DWGS
FOR DEPTH OF
SLAB DEPRESSION
MIN
T
[SEE PLAN]
TOSL
SEE PLAN
T
50x100 CONT KEY
APPLY LIQUID CURING
COMPOUND TO ENTIRE
FACE OF PREVIOUS POUR
TO PREVENT BONDING
PREVIOUS POUR NEW POUR
50 CLR
SEE PLAN
[SEE PLAN]
TOSL
T
TYPICAL SLAB-ON-GRADE SAWED CONTRACTION JOINT (SJ) KEYED CONSTRUCTION JOINT (KCJ) SLAB DEPRESSION (SD)
50 50
150 150 150 150
SEE PLANSEE PLAN
SLAB REINFORCEMENT,
SEE PLAN
[SEE PLAN]
TOSL
50x100 CONT KEY
STD 180° HOOK
AT DOOR
SLOPE AT
EXTERIOR
SLABS ONLY,
SEE PLAN
WALL BEYOND,
SEE PLAN
DN
SECTION
INTERIOR WALL
SLAB-ON-GRADE EACH SIDE
[SEE PLAN]
TOF
[SEE PLAN]
TOSL
WALL
FOOTING,
SEE PLAN
WALL REINFORCEMENT,
SEE PLAN AND SCHEDULE
STD 180° HOOK
AT DOOR
WALL BEYOND,
SEE PLAN
SECTION
EXTERIOR WALL
TYPICAL
[SEE PLAN]
TOF
SIDEWALK,
SEE CIVIL DWGS
12 PJF
[SEE PLAN]
TOSL
WALL
FOOTING,
SEE PLAN
OVERHEAD DOOR,
SEE ARCH DWGS
SECTION
EXTERIOR WALL
AT OVERHEAD DOOR
[SEE PLAN]
TOF
PAVING,
SEE CIVIL DWGS
12 PJF
WALL BEYOND,
SEE PLAN
DRAPE SLAB BARS AT
THRESHOLD
(1) Ø12 AT RE-ENTRANT
CORNER, EACH SIDE,
MIDDLE OF SLAB
12 PJF CONT (TYP)
EXTERIOR CONCRETE
WALL DOWN TO
FOOTING, SEE PLAN
PLAN
EXTERIOR
E D
G E
O F
S
LA
B
Ø12 AT 300 OC
C
LR
S E
E A
R C
H D
W G
S
W A
LL
O
P E
N
IN
G
(1) Ø12 AT RE-ENTRANT
CORNER, EACH SIDE,
MIDDLE OF SLAB
12 PJF CONT
AROUND WALLS
(TYP AT JAMBS)
INTERIOR CONCRETE
WALL DOWN TO
FOOTING, SEE PLAN
PLAN
INTERIOR
C
LR
S E
E A
R C
H D
W G
S
W A
LL
O
P E
N
IN
G
(1
Ø
C O
N T
K C
J
TURN DOWN VAPOR RETARDER
TO TOP OF FOOTING TURN DOWN VAPOR RETARDER
TO TOP OF FOOTING
WALL
FOOTING,
SEE PLAN
TURN DOWN VAPOR RETARDER
TO TOP OF FOOTING
C
LR
C
LR
SLOPE TO
DRAIN 1:10
CONT GALV L51x51x6.4 WITH Ø12 x100 HEADED
STUDS AT 600 OC AND
100 FROM ENDSSLAB REINFORCEMENT,
SEE PLAN
WALL
REINFORCEMENT,
SEE PLAN AND
SCHEDULE
WALL REINFORCEMENT,
SEE PLAN AND SCHEDULE
Ø12 AT 300 OC, EACH WAY
CONCRETE
SLAB-ON-GRADE
FACE OF EQUIPMENT
EQUIPMENT PAD
20 CHAMFER (TYP)
[SEE PLAN]
TOSL
C
LR
U O
N
ROUGHEN SURFACE
TO 3mm AMPLITUDE
AND APPLY
BONDING AGENT
TYP
NOTE:
COORDINATE SIZE AND HEIGHT
OF EQUIPMENT PAD WITH
EQUIPMENT MANUFACTURER
Ø12 DOWELS AT 300 OC
WITH STD 90° HOOK.
DRILL AND EPOXY 75 INTO SLAB.
SLAB REINFORCEMENT,
SEE PLAN
CONCRETE
SLAB-ON-GRADE
20x75x150 PLATE
DOWELS AT 450 OC
[SEE PLAN]
TOSL
SEE PLAN
T
APPLY LIQUID CURING
COMPOUND ALONG ENTIRE
FACE OF PREVIOUS POUR
TO PREVENT BOND
SEMIRIGID JOINT FILLER
DOWELED CONSTRUCTION JOINT (DCJ)
E Q
E Q
SLAB REINFORCEMENT,
SEE PLAN
CONCRETE
SLAB-ON-GRADE
VAPOR RETARDER
[SEE PLAN]