This document is an architectural drawing for the Repair BEQ AS4212 project at Marine Corps Base Camp Lejeune, specifically showing detailed stair plans and sections for a multi-story building. The drawing (Sheet A-406) provides comprehensive technical illustrations of the west stair sections across first, second, and third floors, including transverse and longitudinal stair sections with precise floor height measurements and dimensional details. Key technical specifications include 10 risers per stair section, 9 existing treads at 11" each, and multiple handrail sections with notes referencing additional guardrail and attachment details on other drawing sheets. The document is part of a Naval Facilities Engineering Systems Command (NAVFAC) construction contract, with the drawing dated 11 June 2024 and a recent roofing amendment noted on 07/25/2025, indicating an ongoing renovation or repair project for a barracks (BEQ) facility.

View the file

Other files

File Type Posted
Amend 0021.pdf PDF
Amend 0020.pdf PDF
Amend 0019.pdf PDF
Amend 0018.pdf PDF
Amend 0017.pdf PDF
Amend 0016.pdf PDF
Amend 0015.pdf PDF
Amend 0013.pdf PDF
Amend 0014.pdf PDF
60040177.pdf PDF
60040178.pdf PDF
60040167.pdf PDF
Updated SUBMITTAL REGISTER.pdf PDF
60040172.pdf PDF
60040137.pdf PDF
Updated List of Drawings.pdf PDF
60040262.pdf PDF
60040179.pdf PDF
60040268.pdf PDF
Updated PROJECT TABLE OF CONTENTS.pdf PDF
60040164.pdf PDF
11 81 00.pdf PDF
60040187.pdf PDF
60040189.pdf PDF
60040299.pdf PDF
07 60 00.pdf PDF
07 61 15.00 20.pdf PDF
60040174A.pdf PDF
60040250.pdf PDF
60040188.pdf PDF
05 51 33.pdf PDF
Amend 12 and spec combined.pdf PDF
Amend 0012.pdf PDF
Amend 0011.pdf PDF
Amend 0010.pdf PDF
Amend 0009.pdf PDF
60040202_PPI.pdf PDF
60040196_PPI.pdf PDF
60040201_PPI.pdf PDF
PROJECT.pdf PDF
60040198_PPI.pdf PDF
60040197_PPI.pdf PDF
SECTION 33 61 14.pdf PDF
60040199_PPI.pdf PDF
60040210_PPI.pdf PDF
Amend and cont sheet combined.pdf PDF
60040195_PPI.pdf PDF
60040290_PPI.pdf PDF
REGISTER.pdf PDF
60040194_PPI.pdf PDF
Show 40 more

Latest 50 of 61 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1ST FLOOR

0"

2ND FLOOR

10'-8"

3RD FLOOR

21'-4"

ATTIC DECK

31'-10"

B5

A-406

B5

A-406

NOTE: SEE A-504 FOR HANDRAIL DETAILS

A-504

D6

1ST FLOOR

0"

2ND FLOOR

10'-8"

3RD FLOOR

21'-4"

ATTIC DECK

31'-10"

B4

A-406

B4

A-406

HANDRAIL

SECTION S2

HANDRAIL

SECTION S4

HANDRAIL

SECTION S3

(SIM.)

9 TREAD @ 11" EACH (TYP.)

8'-3"

R

IS

E

R S

5' -4

R

IS

E

R S

5' -4

R

IS

E

R S

5' -4

R

IS

E

R S

5' -4

HANDRAIL

SECTION S2

(SIM.)

HANDRAIL

SECTION S6

HANDRAIL

SECTION S3

HANDRAIL

SECTION S3

(SIM.)

EXISTING

GUARDRAIL

TO REMAIN

(TYP.)

NOTE: SEE A-504 FOR HANDRAIL DETAILS

A-503

B5

HANDRAIL

SECTION S1

HANDRAIL

SECTION S2

6' -8

6'

-8

6' -8

1' -8

3'

-4

8' -4

6'

-8

'-0

1'-8" 8'-0" 1'-8"

11'-4"

B4

A-406

B5

A-406

HANDRAIL

SECTION S3

HANDRAIL

SECTION S4

HANDRAIL

SECTION S5

HANDRAIL SECTION S3 (SIM.)

3'-8" 8" 3'-8"

6' -8

6'

-8

6' -8

1' -8

3'

-4

8' -4

6'

-8

'-0

1'-8" 8'-0" 1'-8"

11'-4"

B4

A-406

B5

A-406

E

X

IS

IT

N

G T

R E

A D

S

1"

8' -3

1'

-0

E

X

IS

IT

N

G T

R E

A D

S

1"

8' -3

1'

-0

HANDRAIL

SECTION S1

HANDRAIL

SECTION S2

6' -8

6'

-8

6' -8

1' -8

3'

-4

8' -4

6'

-8

'-0

1'-8" 8'-0" 1'-8"

11'-4"

B4

A-406

B5

A-406

E

X

IS

IT

N

G T

R E

A D

S

1"

8' -3

1'

-0

E

X

IS

IT

N

G T

R E

A D

S

1"

8' -3

1'

-0

HANDRAIL

SECTION S1

(SIM.)

HANDRAIL

SECTION S2

(SIM.)

HANDRAIL

SECTION S3 (SIM.)

HANDRAIL

SECTION S5

(SIM.)

7"

1'-0"

HANDRAIL EXTENSION

TO LOOP AND RETURN

TO ITSELF

HANDRAIL

SECTION S6

1. SEE A-504 FOR GUARDRAIL SECTIONS, ELEVATIONS, AND DETAILS

2. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION

3. SEE STRUCTURAL FOR ATTACHMENT OF C-CHANNEL TO EXISTING STAIR

4. SEE STRUCTURAL FOR CONCRETE STAIR REPAIR INFORMATION

F ile

P ri n t

SYM. DESCRIPTION DATE APP.

REVISIONS

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091

CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M B

F A

N O

SPEC.

S p ro je c ts

\2

\2

C

L R e p a ir B

E Q

A S

\2

D e s ig n \2

D w g s \2

A

R C

H

.r v t

/2

/2

:2

:3

A

M

A-406

JAS

DJE,III

JENNI REED

JAS

REPAIR BEQ AS4212

ENLARGED STAIR PLANS AND SECTIONS

60040186 N40085-23-B-0035

11 JUNE 2024

GRAPHIC SCALE: 3/8"=1'-0"

3' 0 2' 6'

GRAPHIC SCALE: 1/2"=1'-0"

2' 0 1' 2' 4'

SCALE: 3/8" = 1'-0"

B4

TRANSVERSE STAIR SECTION

SCALE: 3/8" = 1'-0"

B5

LONGITUDINAL STAIR SECTION

SCALE: 1/2" = 1'-0"

C1

WEST STAIR - FIRST FLOOR

SCALE: 1/2" = 1'-0"

C2

WEST STAIR - SECOND FLOOR

SCALE: 1/2" = 1'-0"

A1

WEST STAIR - THIRD FLOOR