60040174A.pdf

PDF 708 KB Posted

Attached to
BEQ Repair AS4212
Solicitation number
N4008525R2620
Issued by

About this file

This document is an architectural drawing (Sheet A-105) for a Marine Corps Base Repair project at BEQ AS4212, detailing attic plans and construction details for a building renovation. The drawing provides comprehensive technical specifications for attic deck demolition and new construction, including specific instructions for roof and catwalk modifications. Key technical details include removing existing 5/4" x 6" catwalk decking, installing new R-38 blown-in insulation, providing a new roof hatch access ladder, and constructing a catwalk with 2x12 wood joists at 16" on center. The drawing specifies precise measurements, material requirements, and coordination instructions for mechanical, electrical, and fire protection systems integration, with a focus on maintaining existing structural elements while upgrading insulation and access points.

View the file

Other files

File Type Posted
Amend 0021.pdf PDF
Amend 0020.pdf PDF
Amend 0019.pdf PDF
Amend 0018.pdf PDF
Amend 0017.pdf PDF
Amend 0016.pdf PDF
Amend 0015.pdf PDF
Amend 0013.pdf PDF
Amend 0014.pdf PDF
60040177.pdf PDF
60040178.pdf PDF
60040167.pdf PDF
Updated SUBMITTAL REGISTER.pdf PDF
60040172.pdf PDF
60040137.pdf PDF
Updated List of Drawings.pdf PDF
60040262.pdf PDF
60040179.pdf PDF
60040268.pdf PDF
Updated PROJECT TABLE OF CONTENTS.pdf PDF
60040164.pdf PDF
11 81 00.pdf PDF
60040186.pdf PDF
60040187.pdf PDF
60040189.pdf PDF
60040299.pdf PDF
07 60 00.pdf PDF
07 61 15.00 20.pdf PDF
60040250.pdf PDF
60040188.pdf PDF
05 51 33.pdf PDF
Amend 12 and spec combined.pdf PDF
Amend 0012.pdf PDF
Amend 0011.pdf PDF
Amend 0010.pdf PDF
Amend 0009.pdf PDF
60040202_PPI.pdf PDF
60040196_PPI.pdf PDF
60040201_PPI.pdf PDF
PROJECT.pdf PDF
60040198_PPI.pdf PDF
60040197_PPI.pdf PDF
SECTION 33 61 14.pdf PDF
60040199_PPI.pdf PDF
60040210_PPI.pdf PDF
Amend and cont sheet combined.pdf PDF
60040195_PPI.pdf PDF
60040290_PPI.pdf PDF
REGISTER.pdf PDF
60040194_PPI.pdf PDF
Show 40 more

Latest 50 of 61 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. SEE ENLARGED PLANS FOR SLEEPING ROOM AND AND COMMON AREA

REFLECTED CEILING PLAN INFORMATION.

2. COORDINATE ALL CEILING WORK WITH MECHANICAL, ELECTRICAL, AND FIRE

PROTECTION DRAWINGS.

3. PROVIDE NEW FINISHES FOR ALL SPACES AS DESCRIBED IN THE ROOM FINISH

SCHEDULE.

4. UNDERSIDE OF EXISTING PRECAST CONCRETE BALCONY/ROOF TO REMAIN

UNFINISHED UNLESS NOTED OTHERWISE.

5. ANY AND ALL FIRE PROTECTION, PLUMBING, MECHANICAL, AND/OR ELECTRICAL

ITEM SHOWN ARE FOR COORDINATION PURPOSES ONLY. SEE RESPECTIVE

PLANS AND LEGENDS FOR ADDITIONAL INFORMATION.

6. CONTRACTOR TO COORDINATE SUSPENDED CEILING SUPPORT CABLE

LOCATIONS WITH MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE

PROTECTION SYSTEMS.

EXISTING WOOD TRUSSES AT 2'-8" ON CENTER

EXISTING WOOD

TRUSSES AT 2'-8" ON

CENTER, TYPICAL

EXISTING WOOD TRUSSES AT 2'-8" ON CENTER EXISTING WOOD TRUSSES AT 2'-8" ON CENTER, TYPICAL

EXISTING WOOD TRUSSES AT 2'-8" ON CENTER

268'-8"

1' -1

3'

-8

REMOVED 5/4" x 6" CATWALK DECKING, EXISTING FRAMING REMAINS

EXISTING ATTIC ACCESS HATCH TO REMAIN

REMOVE EXISTING 2x WOOD BLOCKING BETWEEN TRUSSES TO FACILITATE

INSTALLATION OF NEW ROOF HATCH ACCESS LADDER

REMOVE ROOF SHEATHING ABOVE TO FACILITATE INSTALLATION OF NEW

ROOF HATCH ABOVE

REMOVE EXISTING R-30 ATTIC BATT INSULATION AND POLYETHELENE VAPOR

RETARDER THROUGHOUT ENTIRE ATTIC AND PREPARE EXISTING ATTIC FOR

INSTALLATION OF NEW BLOWN-IN INSULATION

EXISTING WOOD TRUSSES AT 2'-8" ON CENTER

EXISTING WOOD

TRUSSES AT 2'-8" ON

CENTER, TYPICAL

EXISTING WOOD TRUSSES AT 2'-8" ON CENTER EXISTING WOOD TRUSSES AT 2'-8" ON CENTER, TYPICAL

EXISTING WOOD TRUSSES AT 2'-8" ON CENTER

B6

A-503

163'-3" 3'-0"2'-9"2'-8" 97'-0"

268'-8"

4' -0

1' -2

4' -0

A-105

B6

DASHED LINE REPRESENTS LOCATION OF EXTERIOR FACE OF WALL BELOW

AND LIMIT OF INSTALLATION OF NEW R-38 BLOWN-IN INSULATION. INSTALL

PLYWOOD INSULATION BLOCKING AT LIMITS OF BLOWN-IN INSULATION TO

RETAIN INSULATION. ATTACH INSULATION BLOCKING TO EXISTING FRAMING

USING 2x WOOD BLOCKING. INSULATION BLOCKING HEIGHT MUST BE EQUAL

TO DEPTH OF INSULATION PLUS 2" (APPROXIMATELY 14")

PROVIDE CATWALK

ROOF HATCH ABOVE. REFERENCE DETAIL A5/A-502

METAL ROOF HATCH ACCESS LADDER. ATTACH AT CATWALK FLOOR AND

ROOF STRUCTURE PER MANUFACTURERS RECOMMENDATIONS.

REFERENCE DETAIL C3/A-503

PROVIDE PLYWOOD INSULATION BLOCKING AT EXISTING ATTIC ACCESS

HATCH PERIMETER TO PREVENT INSULATION LOSS. ATTACH INSULATION

BLOCKING TO EXISTING FRAMING USING 2x WOOD BLOCKING. INSULATION

BLOCKING HEIGHT MUST TO EQUAL DEPTH OF INSULATION PLUS 2"

(APPROXIMATELY 14")

4' -0

1'-4" 1'-4"

2'-8"

EXISTING TRUSSES AT 2'-8"

ON CENTER

2x WOOD BLOCKING

BETWEEN TRUSS AND JOIST

EXISTING 2x6 TRUSS

FRAMING TO REMAIN

EXISTING CONTINUOUS TREATED

WOOD PLATE REMAINS

3/4" PLYWOOD SHEATHING

AT CATWALK

2x12x7'-4" LONG WOOD

JOISTS AT 16" ON CENTER.

ATTACH TO EXISTING 2x8

PLATE AT BASE, ATTACH

EVERY OTHER TO EXISTING

TRUSSES WITH WOOD

BLOCKING

A1

A-105

V E

R

IF

Y

7' -5

/2

EXISTING TRUSS BEYOND

2x12 CATWALK FRAMING AT 16" ON

CENTER

3/4" PLYWOOD CATWALK SHEATHING

PROVIDE 2x BLOCKING TO ATTACH

CATWALK JOISTS TO TRUSSES

EXISTING 2x8 WOOD PLATE

REMAINS

EXISTING PRECAST ATTIC/CEILING

ASSEMBLY WITH CONCRETE TOPPING

EXISTING CMU WALL

CONTINUOUS R-38 BLOWN-IN

PLACE INSULATION

4"

SLOPE 1/2"

3/ 4"

3/4" CDX PLYWOOD OVER

CONTINUOUS TREATED WOOD

BLOCKING

SHEET METAL COPING CAP,

SEE DETAIL B5/A-501

PEEL & STICK UNDERLAYMENT

EXISTING EXTERIOR

WALL SHEET METAL COUNTER-

FLASHING AND TRIM

SHEET METAL FLASHING

ICE AND WATER SHIELD.

EXTEND UP AND LAP

OVER PARAPET

EXISTING PLYWOOD

ROOF SHEATHING

EXISTING CONTINOUS 2x

NAILER

E X

IS

TI

N G

1' -0

F ile

P ri n t

SYM. DESCRIPTION DATE APP.

REVISIONS

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB

E W

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091

CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M B

F A

N O

SPEC.

S p ro je c ts

\2

\2

C

L R e p a ir B

E Q

A S

\2

D e s ig n \2

D w g s \2

A

R C

H

.r v t

/2

/2

:2

:1

A

M

A-105

JAS

DJE,III

JENNI REED

JAS

REPAIR BEQ AS4212

ATTIC PLANS AND DETAILS

N40085-23-B-0035

OF 179

E

25 JULY 2025

N

GRAPHIC SCALE: 3/32"=1'-0"

8' 0 8' 16' 24'

GENERAL CONSTRUCTION NOTES

SCALE: 3/32" = 1'-0"

D3

ATTIC DECK - EXISTING / DEMOLITION

DEMOLITION KEYNOTES

SCALE: 3/32" = 1'-0"

B3

ATTIC DECK - NEW CONSTRUCTION

CONSTRUCTION KEYNOTES

N

SCALE: 1/2" = 1'-0"

B6

ENLARGED CATWALK PLAN

GRAPHIC SCALE: 1/2"=1'-0"

2' 0 1' 2' 4'

SCALE: 1" = 1'-0"

A1

CATWALK DETAIL

GRAPHIC SCALE: 1"=1'-0"

1' 0 1' 2'

SCALE: 1 1/2" = 1'-0"

A4

TYPICAL PARAPET DETAIL

GRAPHIC SCALE: 1 1/2"=1'-0"

1' 6" 3" 0 1'

4 ROOFING AMENDMENT 07/25/2025

60040174A

File details come from the government source that posted it. Updated .