About this file

This document provides details on a federal solicitation notice for an Indefinite-Delivery, Indefinite-Quantity, Multiple Award Construction Contract for facilities in the Hampton Roads Area of Responsibility in Virginia. The solicitation is being conducted by the Naval Facilities Engineering Command and seeks design-build and design-bid-build construction services on an IDIQ basis. Offerors will be eligible to compete for task orders for large general construction projects primarily in the Hampton Roads Area, including design services where applicable. The solicitation number is N4008521R2507 and responses are due based on the posting date.

View the file

Other files

File Type Posted
21R2507 0016.pdf PDF
21R2507 0015.pdf PDF
21R2507 0018.pdf PDF
21R2507 0019.pdf PDF
21R2507 0017.pdf PDF
SKM-1.pdf PDF
21R2507 0014.pdf PDF
21R2507 0013.pdf PDF
21R2507 0012.pdf PDF
21R2507 0011.pdf PDF
21R2507 0010.pdf PDF
21R2507 0009.pdf PDF
21R2507 0008.pdf PDF
P1035 Site Visit.pdf PDF
ATT G SMALL BUSINESS SUBCONTRACTING PLAN.docx DOCX document
21R2507 0007.pdf PDF
21R2507 0006.pdf PDF
21R2507 0005.pdf PDF
One Day Pass Request.xls XLS spreadsheet
ATTACHMENT E Historical SB Utilization.docx DOCX document
21R2507 0004.pdf PDF
21R2507 0003.pdf PDF
1614720dwg03of16_CivilR.pdf PDF
1614720 P1035 DesRev01 17Nov2020.pdf PDF
1614720dwg02of16_BoringsR.pdf PDF
1614720dwg09of16_GeneralR.pdf PDF
21R2507 0002.pdf PDF
1614720dwg15of16_CathodicR.pdf PDF
Attachment A Con Des.docx DOCX document
21R2507 0001.pdf PDF
Attachment C SB Commitment.docx DOCX document
Attachment D PPI Log.xlsx XLSX spreadsheet
Attachment B PPQ.docx DOCX document
1614720_P1035 SID BINDER.pdf PDF
1614720dwg12of16_WaterTreatment.pdf PDF
1614720dwg14of16_Electrical.pdf PDF
1614720dwg09of16_General.pdf PDF
Price Proposal Form 11-13-20.pdf PDF
1614720spc02of03.pdf PDF
N4008521R2507 RFP.pdf PDF
1614720_P1035 CxPlan w FPT and PFC.pdf PDF
1614720dwg16of16_Telecom.pdf PDF
1614720dwg08of16_Interiors.pdf PDF
1614720_P1035 Bldg V-57 Laundry - 1943 dwgs.pdf PDF
1614720dwg04of16_Landscape.pdf PDF
1614720dwg15of16_Cathodic.pdf PDF
1614720_P1035 OPR.pdf PDF
1614720dwg02of16_Borings.pdf PDF
1614720spc03of03.pdf PDF
1614720dwg07of16_Architectural.pdf PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AND&

EXIST EXISTING

VINYL COMPOSITION TILEVCT

AFS

ADJ

AT

APPROX

AFF

BD

ALUM

APPROXIMATE

BOARD

ABOVE FINISH FLOOR

ABOVE FINISH SLAB

ALUMINUM

ADJUSTABLE, ADJUST

CEILING

COL

CLG

DIA

CMU

CONC

DOW NDN

EQUIP

ELEC

ELEV

EQUIPMENT

ELECTRICAL

ELEVATION

CONCRETE MASONRY UNIT

CONCRETE

DIAMETER

COLUMN

FLOOR

FO

FLR

GWB GYPSUM WALLBOARD

FACE OF

EQ EQUAL

CENTER LINE

HORIZ HORIZONTAL

TYPICALTYP

TOC TOP OF CONCRETE

W IDTH / WASHER

VERT

W

VERTICAL

UNLESS OTHERWISE NOTEDUON

HOLLOW METALHM

VIF VERIFY IN FIELD

CL

ALT ALTERNATE

APC ARCHITECTURAL PRECAST CONCRETE

ACT ACOUSTICAL CEILING TILE

BLDG BUILDING

BLKG BLOCKING

BRG BEARING

BUR BUILT-UP ROOFING

CORNER GUARDCG

CONTROL JOINTCJ

CLEARCLR

CONST CONSTRUCTION

CONT CONTINUOUS

CPT CARPET

CT CERAMIC TILE

D DEPTH / DRYER

DBL DOUBLE

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DOWNSPOUTDS

DRAW INGDWG

EACHEA

EXPANSION JOINTEJ

EDGE OF SLABEOS

EPS EXPANDED POLYSTYRENE

EXP EXPANSION / EXPOSED

EXT EXTERIOR

FD FLOOR DRAIN

FEB FIRE EXTINGUISHER BRACKET

FEC FIRE EXTINGUISHER CABINET

FGL FIBERGLASS

FF FINISH FLOOR

FIN FINISH

FP FIRE PROTECTION

GA GAUGE

GALV GALVANIZED

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLASS

GYP GYPSUM

HDW HARDWARE

HI HIGH

HT HEIGHT

HVAC HEATING, VENTILATION, & AIR

CONDITIONING

ID INSIDE DIAMETER

INSUL INSULATION

INT INTERIOR

JBE JOIST BEARING ELEVATION

L LENGTH / LONG

MATL MATERIAL

SUSPENDEDSUSP

THR THRESHOLD

TOW TOP OF W ALL

TP TOILET PARTITION

TOP & BOTTOMT & B

VINYL BASEVB

VTR VENT THRU ROOF

W ITHW/

W ITHOUTW/O

W ALLCOVERINGW C

WOODWD

WINDOWWDW

WINDOW OPENINGWO

WORK POINTWP

WEIGHTW T

EXTRUDED POLYSTYRENEXPS

METALMTL

NIC

MISC

OC

MISCELLANEOUS

ON CENTER

NOT IN CONTRACT

ROOM

SIMILAR

R

RM

REF

SIM

RO

SS

RADIUS

STAINLESS STEEL

ROUGH OPENING

REFRIGERATOR

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MO MASONRY OPENING

MTG MOUNTING

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED

OFOI OWNER FURNISHED

OH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

PL PLATE

PLAM PLASTIC LAMINATE

PLYWD PLYWOOD

PR PAIR

PTD PAINTED

RD ROOF DRAIN

REINF REINFORCING

REQ'D REQUIRED

RWL RAIN WATER LEADER

SAB SOUND ATTENUATING BLANKET

SF SQUARE FEET

SQUARESQ

STRUCTURALSTRUCT

STD STANDARD

STL STEELCONTRACTOR INSTALLED

OWNER INSTALLED

TTL TOTAL

PH PANIC HARDWARE

KO KNOCK OUT

GC GENERAL CONTRACTOR

IGU INSULATING GLASS UNIT

POLYISO POLYISOCYANURATE

INSULATION

FRT FIRE RETARDANT TREATED

TELE TELECOMMUNICATION

SAFB SOUND ATTENUATING FIRE BLANKETS

JT JOINT

PMB PLASTIC MEDIA BLASTING

HDWD HARDWOOD

LO LOW

PT PRESSURE TREATED

AT/FP ANTI-TERRORISM / FORCE PROTECTION

CONCRETE WOOD BLOCKING - INTERRUPTED

BRICK

CONCRETE MASONRY UNIT

(CMU)

INSULATION - BATT /

LOOSE / BLANKET

PLYWOOD / MDF

EARTH

W OOD BLOCKING /

FRAMING - CONTINUOUS

INSULATION - RIGID

POROUS FILL

INSULATION - SPRAY FOAM

GWB / PLASTER / GROUT /

SPRAY FIREPROOFING

STEEL

A

A1

AE201

A1

AE201

A3

A2A4

NEW WORK KEYNOTE

PARTITION / W ALL TYPE

DETAIL / PLAN NUMBER

SHEET WHERE SHOW N

ELEVATION NUMBER

SHEET WHERE SHOWN

XX.X

ELEVATION DATUM

+12'-0"

FIRST FLOOR

ROOM DESIGNATION

DIRECTION OF SLOPE

ROOF SLOPE

FLOOR DRAIN

FIRE

EXTINGUISHER

CABINET

FIRE

EXTINGUISHER

BRACKET

FD

DETAIL, SECTION,

ELEVATION TITLE

DETAIL / ENLARGED PLAN

PLAN TITLE

AND NORTH ARROW

INTERIOR ELEVATION

EXTERIOR ELEVATION

ELEVATION NUMBER

SHEET WHERE SHOWN

BUILDING SECTION

SECTION NUMBER

SHEET WHERE SHOW N

DETAIL / W ALL SECTION

DOOR NUMBER12

AE301

A1

AE301

A1

AE301

A1

A1

AE101

W INDOW / STOREFRONT

DESIGNATION

REVISION TAG

FEC FEB

A1 / AE101

ADJACENT AREA

REFERENCE

W 1 S1

SPECIALTY ITEM DESIGNATION

MATCHLINE

BUILDING

SHEET WHERE SHOW N

SECTION NUMBER

NAME

SCALE:A1

NAME

SCALE:

TRUE NORTH INDICATOR

PLAN NORTH INDICATOR

ROOM NAME

LOUVER / TRANSLUCENT PANEL

DESIGNATION

L1 K1

PAIR OF DOORS

INACTIVE LEAF (TOP

AND BTM BOLTS)

ACTIVE LEAF

(REFERENCING SHEET)

GWB

CEILING / SOFFIT

METAL PANEL

SOFFIT

OS

S

H P

FIRE ALARM STROBE / FIRE ALARM HORN STROBE

SPEAKER / SPEAKER W/ STROBE

CEILING MOUNTED

OCCUPANCY SENSOR

CARBON MONOXIDE SENSOR

HEAT SENSOR / PHOTO SENSOR

SMOKE DETECTOR

CEILING HEIGHTEXPOSED CEILING

INDICATES BRACKET, WALL MOUNTED

FIRE PROTECTION FIXTURE / EQUIPMENT, ETC

CEILING MOUNTED RECEPTACLE

CO

8'-0"

S

S

EXP

SUPPLY GRILLE / RETURN GRILLE

V F

EXHAUST FAN

CEILING MOUNTED SECURITY CAMERA

ACCESS PANEL

2' x 2' METAL PANEL

CEILING

CEILING MOUNTED

EXIT LIGHT

CEILING MOUNTED

EXIT LIGHT W / ARROW

LIGHT FIXTURE EMERGENCY EGRESS LIGHT FIXTURE

INDICATES BRACKET, WALL MOUNTED

ELECTRICAL LIGHT / FIXTURE / EQUIPMENT, ETC

SPRINKLER HEAD

2' x 4' ACT CEILING

PS

CEILING MOUNTED

DAYLIGHTING SENSOR

FRP CEILING

WALL MOUNTED ACU

1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF MASONRY, AND TO CENTERLINE OF

COLUMNS.

2. ALL NOTES, DETAILS, AND FEATURES DRAWN AS APPLICABLE FOR ONE CONDITION ARE APPLICABLE TO SIMILAR

CONDITIONS, W HETHER OR NOT SPECIFICALLY INDICATED.

3. IN STUD WALLS, LOCATE ALL INTERIOR DOOR FRAMES A DISTANCE OF 4" (FOUR) INCHES FROM THE THROAT RETURN TO THE CLOSEST ADJACENT PERPENDICULAR PARTITION, UON. IN CMU AND PRECAST W ALLS, LOCATE MASONRY

OPENING AT DOORS 8" (EIGHT) FROM THE PERPENDICULAR W ALL.

4. ALL ELEVATIONS ARE MEASURED FROM THE REFERENCE ELEVATION +0'-0", WHICH IS THE TOP OF THE FIRST FLOOR

SLAB, UON.

5. DO NOT SCALE DRAW INGS TO DETERMINE DIMENSIONS OR SIZES OF BUILDING ELEMENTS.

6. ALL W OOD BLOCKING AND MISCELLANEOUS STEEL SHOW N IN DETAILS AND SECTIONS SHALL BE CONTINUOUS, UON.

7. USE FIRE-RETARDANT TREATED W OOD PRODUCTS FOR ALL CONCEALED WOOD BLOCKING, UON.

8. USE PRESERVATIVE-TREATED W OOD PRODUCTS FOR ALL WOOD BLOCKING IN CONTACT WITH EXTERIOR MASONRY OR CONCRETE W ALLS, AND FOR ALL W OOD BLOCKING IN CONTACT W ITH CONCRETE SLABS ON GRADE.

9. VERIFY ALL DIMENSIONS. BRING ANY DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.

10. NOTIFY ARCHITECT OF ANY DISCREPANCY BETWEEN DRAWINGS AND SPECIFICATIONS

11. PROVIDE W OOD OR METAL BLOCKING BEHIND GW B AT THE FOLLOWING LOCATIONS:

A. ALL W ALL-MOUNTED OR CEILING-MOUNTED DOOR STOPS, DOOR HOLD-OPEN DEVICES, AND OTHER HARDW ARE.

B. ALL W ALL-MOUNTED TOILET ACCESSORIES. AT GRAB BARS, PROVIDE BLOCKING CAPABLE OF RESISTING A MINIMUM LOAD OF 250 POUNDS APPLIED VERTICALLY OR HORIZONTALLY AT ANY POINT ON THE GRAB BAR.

C. ALL W ALL-MOUNTED PLUMBING FIXTURES, INCLUDING BUT NOT LIMITED TO LAVATORIES, SINKS, URINALS, WATER CLOSETS, AND W ATER COOLERS. PROVIDE BLOCKING CAPABLE OF RESISTING A MINIMUM LOAD OF 400 POUNDS

APPLIED VERTICALLY AT ANY POINT ON THE PLUMBING FIXTURE.

D. ALL W ALL-MOUNTED CABINETRY, SHELVING, AND SIMILAR ITEMS.

E. ALL W ALL-MOUNTED VIDEO MONITORS, AND SIMILAR ITEMS.

12. ALL MATERIALS USED IN THE PROJECT SHALL BE NEW AND PROVIDED BY THE CONTRACTOR, UON.

13. USE BITUMINOUS MEMBRANE TO SEPARATE PRESERVATIVE-TREATED W OOD PRODUCTS FROM CONTACT W ITH ANY

METAL SURFACE.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

A R

C H

IT

E

C

TU

R A

L

LE

G E

N D

S A

N D

N O

TE

S

DLF

12822601

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

A-001

ARCHITECTURAL GENERAL NOTES

ARCHITECTURAL ABBREVIATIONS

ARCHITECTURAL SYMBOLOGY

MATERIAL LEGEND

RCP LEGEND

NOT ALL ABBREVIATIONS, SYMBOLS, AND LEGEND

GRAPHICS LISTED ARE NECESSARILY USED ON THIS

PROJECT. REFER TO DOCUMENTS FOR SPECIFIC

INFORMATION.

E

LE

C T

R

IC

A L

F

IR

E P

R O

T E

C T

IO

N

A R

C H

IT

E

C T

U R

A L

M E

C H

A N

IC

A

L

FLOOR PLAN LEGEND

BID OPTIONS

• LIFT TABLES @ PMB BAY

- REFER TO SHEET AE101

• LIFT TABLES @ PAINT BAY

- REFER TO SHEET AE102

• LIFT TABLES @ WASH BAY

- REFER TO SHEET AE104

• TRANSLUCENT PANELS @ WASH BAY

- REFER TO SHEETS AE201 AND AE203

• ACOUSTICAL PANELS @ PMB BAY

- REFER TO SHEETS AE111

• ACOUSTICAL PANELS @ PAINT BAY

- REFER TO SHEETS AE112

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

AE203

D1

AE204

D1

AE201

D1

AE202

D1

WASH RACK

(PROCESS)

WASH RACK

BAY

DECONTAMINATION

COMM.

FIRE

PROTECTION

MECHANICAL

ROOM

PMB BAY

PAINT BAY

PAINT BAY

(PROCESS)

PAINT BAY

SUPPLY AIR

PLENUM

PAINT BAY

EXHAUST

AIR PLENUM

PMB BAY

(PROCESS)

PMB BAY

SUPPLY AIR

PLENUM

PMB BAY

EXHAUST

AIR PLENUM

BLAST

MEDIA

RECOVERY

BLAST

MEDIA

STORAGE

PAINT

MIXING

PAINT

STORAGE

ADMIN

WOMEN'S

LOCKER

ROOM

(CLEAN)

AIR DRY

CORR.

CENTRAL

CHEMICAL

STORAGE

PMB BAY

(PROCESS)

PAINT BAY

(PROCESS)

TOOL CRIB

CORR.

WASH RACK

STORAGE

COMM.

CORR.

LOCKER

ROOM

(DIRTY)

MEN'S

LOCKER

ROOM

(CLEAN)

COMPRESSOR

ROOM

MOTHER'S

ROOM

W ATER

TREATMENT

SYSTEM

JAN.

CHILLER

YARD

SOLVENT

STORAGE

LOCKER

ROOM

(DIRTY)

EQUIPMENT

CLEANING

STENCIL

ROOM

MATERIAL

STORAGE

JAN.

TOILET

TOILET

AIR LOCK

ELEC.

PMB

STORAGE

FILTER

STORAGE

ADMIN

CLOSET

BREAK

ISSUE

MECH

ELEC.

AE101

AE102

AE102

AE103

A E

A E

274'-6"

2' -4

'-8

9' -4

1' -4

44'-4" 117'-2"

26'-0" 82'-0" 44'-4" 2'-4" 119'-10"

23'-11 5/8" 89'-0 3/8"

9'

-8

9'

-8

'-0

1' -0

'-0

'-8

274'-6"

'-1

0"

'-0

40'-0" 32'-8"

WASH RACK

EQUIPMENT

PAINT BAY

STORAGE

AE404

A1

'-8

DUST

COLLECTOR

YARD

AE404

C1

ABOVE

AE404

A3

ABOVE

53'-2" 56'-8" 42'-6"

AIR LOCK

1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR

W ALLS.

2. ALL INTERIOR W ALLS SHALL BE M8, UON.

3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF

EQUIPMENT / SHELVING / CASEW ORK.

4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL

DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,

PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN

W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR

TO COMMENCING THE CONSTRUCTION IN QUESTION.

5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,

HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.

6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.

7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND

STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY

ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.

8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR

GLAZING ELEVATIONS AND LOUVER SCHEDULE.

9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

O V

E R

A

LL

F

LO

O R

P

LA

N

DLF

12822602

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE100SCALE: 3/64" = 1'-0"

OVERALL FLOOR PLAN

3/64" = 1' - 0"

0 10' 20' 40' 80'5'

GRAPHIC SCALE(S)

KEY PLAN

GENERAL NOTES

AREA

A

AREA

B

AREA

D

AREA C

V-147

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

A1

AE301

A1

AE301

FILTER

STORAGE

PMB BAY

PMB BAY

(PROCESS)

114B

PMB BAY

SUPPLY AIR

PLENUM

114C

PMB BAY

EXHAUST

AIR PLENUM

BLAST

MEDIA

RECOVERY

BLAST

MEDIA

STORAGE

ELEC.

WOMEN'S

LOCKER

ROOM

(CLEAN)

AIR DRY

CORR.

PMB BAY

(PROCESS)

114A

CORR.

COMM.

LOCKER

ROOM

(DIRTY)

MEN'S

LOCKER

ROOM

(CLEAN)

COMPRESSOR

ROOM

MATCHLINE

AE102

MATCHLINE

AE102

C1

AE301

______________ C1

AE301

JAN.

AE402

A3

115 114A

111B

112111

114C

114B

113B

111A

110A 113A

1A

PMB

STORAGE

TYP22

AIR LOCK

FD

FD

FD FD

FD

'-0

7'

-2

/2

2' -2

'-6

2' -2

6'

-0

/2

6' -8

'-0

8' -8

'-4

9'-2" 12'-0" 12'-2" 6'-0" 85'-6" 4'-4"

'-1

0" 9'

-1

'-8

4'

-0

9' -2

'-1 1"

10'-2 3/8" 12'-0"

9 5/8"

9'-2" 18'-2 3/8" 24'-0" 21'-0"

26'-0" 82'-0" 44'-4"

6' -8

'-1 0"

9' -2

9'

-4

6' -0

8'

-0

4' -4

2' -0

CP14R1

CP10R2

CP14

M12

M12

CP10R2

M12

CP14

M12

CP10R1

CP10R1

M8R1

AE403

A3

AE402

A1

131C

AE411

A4

6' -8

2' -0

8' -0

2'

-8

2' -8

8'

-0

2' -8

'-0

2' -0

8'

-0

'-0

4'

-8

4' -0

2'

-8

6' -8

2'

-0

'-0

3'-7" 6'-8" 11'-11" 6'-0"

8' -0

E

Q 3'

-2

1' -3

3' -2

1' -3

3' -2

E

Q 8'

-0

6'-0" 11'-7" 64'-0" 9'-1" 5'-6"

8" 6'-8" 6'-0" 8'-0" 2'-8" 6'-8" 6'-8" 5'-4" 20'-0" 19'-4"

4" 14'-0" 10'-0" 2'-0" 16'-0" 2'-0"

1'-4" 8" 3'-4" 6'-8" 12'-2" 2" EJ 1'-8"

3' -4

'-0

1' -7

3' -4

2' -3

/2

2'

-0

/2

3' -4

8"

W 1

PAINT BAY

1' -8

3'

-4

2' -0

3' -4

1' -8

9' -8

3'

-4

8"

M12

'-5

C

LR

W

ID

T

H

'-0

6' -0

C

LR

FEB

FEBFEC

FEB

FEB

1' -4

1' -8

1'-8"

1'-8"

41'-0"

6' -8

6'

-0

3' -4

6'

-0

1' -4

1'

-4

L10

L9

TYP

CP14.7

CP14.7

CP14.7

CP14.7

FDFD

AE412

A4

AE412

B4

27'-2" 25'-10" 29'-0"

6' -8

2'

-0

TYP

C J

C J

C J

C J

C J

CJ

C

J

CJ CJ

CJ CJ

C J

4' -7

/8

6' -8

'-8

1' -8

3'

-4

4"

AE505

D2

10'-11" 4'-2" 11'-4" 4'-2" 9'-4" 4'-2" 19'-11"

12'-0" DRIVE

A1

AE314

4'-0"

4'-0"

A2

AE314

56'-8"

'-0

'-4

4' -8

'-8

AE412

B1

DUST

COLLECTOR

YARD

C J

2'-0" 17'-8" 17'-4" 17'-8" 2'-0"

'-8

CJ CJ CJ CJ

C J

C J

112A

112B

L4

L3

ABOVE

ABOVE

CJ

CL

13' - 6"

CL

2' - 6" 15' - 10"

TYP

AE505

D2

C L 1'

0"

FEB

TYP52

3' -4

8'

-1 1"

TYP 55

AE412

B1 SIM

CENTERED ON

SERVICE DOOR

(REFER TO CIVIL)

12'-0" DRIVE

CENTERED ON

SERVICE DOOR

(REFER TO CIVIL)

2'-0"

FEB FEB

CJ

CL1' - 0"

1' -8

6'-0" 6'-0" 10"

AE412

C1

LO

HI

LO

AE412

C1

SIM

HI

SIM

AE411

B4

LO

HI

C

LR

3' -6

2'-4"

TYP57

AE413

A3

EQ EQ EQ EQ EQ EQ

A1

AE505

______________TYP

AE411

D1 SIM

TYP

AE413

A2 HI

LO

AE413

B2 SIM

TYP

C1

AE504

'-1

0"

TYP69

1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR

W ALLS.

2. ALL INTERIOR W ALLS SHALL BE M8, UON.

3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF

EQUIPMENT / SHELVING / CASEW ORK.

4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL

DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,

PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN

W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR

TO COMMENCING THE CONSTRUCTION IN QUESTION.

5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,

HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.

6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.

7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND

STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY

ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.

8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR

GLAZING ELEVATIONS AND LOUVER SCHEDULE.

9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

F

LO

O R

P

LA

N

A R

E A

A

DLF

12822603

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE101

1/8" = 1' - 0"

0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

SCALE: 1/8" = 1'-0"

FLOOR PLAN - AREA A

AREA

A

AREA

B

AREA

D

AREA C

V-147

1A SWINGING PLENUM HANGAR DOOR 21'-3"W X 22'-0"H

4 METAL GRATE FLOORING - REFER TO STRUCTURAL

5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

8 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY

9 PLENUM FILTER WALL - REFER TO MECHANICAL

13 LINE OF PLATFORM ABOVE, SEE ENLARGED PLAN A3/AE404

22 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 3'-0" X 4'-0"

8K LBS CAPACITY

23 EMERGENCY EYEWASH - REFER TO PLUMBING

32 INTERIOR CONCRETE FILLED STEEL PIPE BOLLARD W/HDPE COVER - SEE

DETAIL A2/AE505

33 ENTRANCE FLOOR MAT AND FRAME OVER RECESSED SLAB - REFER TO

INTERIORS, REFER TO STRUCTURAL

35 CONCRETE SIDEWALK AND EQUIPMENT PAD - REFER TO CIVIL

43 EXTERIOR CONCRETE FILLED STEEL PIPE BOLLARD - REFER TO CIVIL

45 PLATFORM ACCESS - METAL LADDER, EXTEND 42" ABOVE PLATFORM

52 PLASTIC MEDIA BARRELS - BY OWNER

55 THRU-WALL SCUPPER, 1'-4" W X 8" H - COORDINATE OUTFALL ABOVE GRADE

56 NOTCH SLAB AROUND SCUPPERS - SEE DETAIL C1/AE504 - REFER TO CIVIL

57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION

60 EDGE OF EQUIPMENT PLATFORM ABOVE

64 LINE OF PLATFORM ABOVE, SEE ENLARGED PLAN B1/AE404

66 CONCRETE PAVEMENT - REFER TO CIVIL

69 REFER TO TELECOM FOR EXTENTS OF PLYWOOD BACKBOARD

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

A1

AE301

MATCHLINE

AE101

MATCHLINE

AE103

MATCHLINE

AE101

PAINT BAY

PAINT BAY

(PROCESS)

120A

PAINT BAY

SUPPLY AIR

PLENUM

120C

PAINT BAY

EXHAUST

AIR PLENUM

BREAK

ISSUE

PAINT BAY

(PROCESS)

120B

MEN'S

LOCKER

ROOM

(CLEAN)

B1

AE301

______________ B1

AE301

AIR LOCK

103A

120A

120B

119A

122 123 124

MECH

104A 104A

1B

9 8

MATCHLINE

AE103

FD

FD

FD

FD

FD

103B

121A

9' -4

'-4

'-4

22'-11" 30'-4" 62'-5" 4'-4"

22'-2 3/8" 9 5/8" 9'-2" 15'-2" 100'-6" 4'-4"

9' -1

'-9

6' -1

8'

-1 0"

'-9

1'-4" 2'-0"

8' -2

'-1 1"

'-0

CP14R2

CP10CP10

CP14R2

M8R1FS3.1

M12

M8R1

M12

CP14R2

AE402

A1

2' -0

'-0

2' -0

2'

-0

'-0

2'

-0

'-0

'-0

'-8

8'

-0

4'-3" 4'-4" 7'-8" 6'-8" 2'-3" 4'-4" 1'-8" 6'-0"

2'-4"

6' -6

/2

'-6

6' -8

/2

2' -4

3'

-4

2' -2

/2

7' -1

1/

2"

2' -2

'-0

2' -2

7'

-8

/2

AE403

B1

S1

S1

W 2

M8FS3.1

AE413

B3

2' -0

5'

-4

4" 3'

-4

1' -8

4"

3' -4

1'

-8

4" 6'

-8

4" 4"

4' -8

4'

-8

3' -4

1'

-8

'-1

1" C

LR

W

ID

T

H

120C

PAINT BAY

STORAGE

120C

10'-4"

CP14.6

CP10CP10CP10R2

CP10R2

2' -1

/2

3'

-4

2' -1

1"

FEC

FEBFEB

FEB

FEB

FEB

FEB

1'-4"

M8FS3.1

CP14.6

C J

C J

C J

C J

C J

4' -8

'-4

'-0

'-8

A1

AE302

______________ A1

AE302

C1

AE302

C1

AE302

A1

AE303

______________ A1

AE303

C1

AE303

C1

AE303

44'-3" 4'-2" 4'-10" 4'-2" 2'-4" 4'-2" 9'-4" 4'-2" 10" 4'-2"

4' -2

2'

-1 0"

3' -2

2'

-1 0"

4' -2

'-1

/2

3'

-2

5' -8

3'

-2

'-4

/2

2' -7

'-0

2' -7

20'-0"

19'-0"

120E

AIR LOCK

120E

121B

8' -5

E Q

E Q

TYP 57

A1

AE505

______________TYP

AE411

D1 SIM

TYP

AE413

B2 SIM

TYP

'-4

1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR

W ALLS.

2. ALL INTERIOR W ALLS SHALL BE M8, UON.

3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF

EQUIPMENT / SHELVING / CASEW ORK.

4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL

DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,

PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN

W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR

TO COMMENCING THE CONSTRUCTION IN QUESTION.

5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,

HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.

6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.

7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND

STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY

ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.

8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR

GLAZING ELEVATIONS AND LOUVER SCHEDULE.

9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

F

LO

O R

P

LA

N

A R

E A

B

DLF

12822604

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE102

SCALE: 1/8" = 1'-0"

FLOOR PLAN - AREA B

1/8" = 1' - 0"

0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

AREA

A

AREA

B

AREA

D

AREA C

V-147

1B SWINGING PLENUM HANGAR DOOR 40'-6"W X 32'-0"H

5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

8 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY

9 PLENUM FILTER WALL - REFER TO MECHANICAL

10 DUAL HEIGHT ELECTRIC WATER COOLER W/ BOTTLE FILLER, SEE SHEET

AE401 FOR TYPICAL ACCESSORY MOUNTING HEIGHTS - REFER TO

PLUMBING

11 EMERGENCY SHOWER AND EYEWASH - REFER TO PLUMBING

15 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 4'-0" X 4'-0"

15K LBS CAPACITY

20 SINK WITH INTEGRAL DRAIN BOARDS - REFER TO PLUMBING

22 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 3'-0" X 4'-0"

8K LBS CAPACITY

57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

A1

AE301

MATCHLINE

AE102

MATCHLINE

AE104

MATCHLINE

AE102

MECHANICAL

ROOM

PAINT

MIXING

PAINT

STORAGE

ADMIN

TOOL CRIB

EQUIPMENT

CLEANING

STENCIL

ROOM

MATERIAL

STORAGE

MOTHER'S

ROOM

ADMIN

CLOSET

101A

CORR.

101A 122A

122B

124A

124123122

CORR.

123A

129A

131B

129B

FD

FD

18'-6" 10'-0" 2'-8"

'-4

9'

-4

1' -4

'-2

'-8

'-4

'-6

'-4

'-4

9'

-4

5'-0"

9' -2

1'-4" 22'-2 3/8"

9 5/8"

9'-2" 18'-6" 12'-8" 8'-8" 15'-4" 26'-8" 3'-4" 27'-0"

2' -0

/8

7' -3

/8

'-4

23'-11 5/8" 89'-0 3/8"

M4

M8FS3.2

M12

M8R1FS3.1

M12

M8R1

M8R1

M8R1

M8R1

M12R1

M12

M4

M4AE411

A2

AE411

D4 131A

4'-0" 16'-0"

3'-11 5/8"

10'-8" 5'-4"

2'-0"

16'-0"

2'-0"

6'-0" 6'-8" 6'-0"

2'-0"

16'-0"

2'-0"

2' -0

2'

-0

'-0

2'

-0

'-8

AE403

A1

6' -8

3'

-4

2' -8

2'

-8

'-0

2'

-8

'-4

E

Q E

Q

M4.3

S1

S1

S1 S1

5' -4

6'

-8

1'-4"

'-4

4" 3'

-4

1' -8

M4

M4

6'-8" 4'-8" EQ EQ

M A

T C

H

LI

N E

A E

FD

FEC

FEC

1'-8"

1'-4"

1' -8

FEB

FEB

TYP

TYP

M4.3

M4

TYP

C J

C J

CJ CJ CJ CJ

C J

C J

5' -4

'-8

2' -0

TYP

1'-4"

T Y

P 1'

-4

2'-0"

M4

M4

2'-0"

7' -0

5' -0

AE505

D2

TYP

14'-4 3/8"

2" E

J

12'-2 3/8" 10'-0" 9'-2"9 5/8"

SIM

9' -4

AE411

B2

LO

HI

1' -4

TYP 57

C L C L

6'

0"

FD

S4

S3

5'-0"

33 33

AE411

D1 SIM

TYP

1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR

W ALLS.

2. ALL INTERIOR W ALLS SHALL BE M8, UON.

3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF

EQUIPMENT / SHELVING / CASEW ORK.

4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL

DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,

PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN

W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR

TO COMMENCING THE CONSTRUCTION IN QUESTION.

5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,

HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.

6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.

7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND

STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY

ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.

8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR

GLAZING ELEVATIONS AND LOUVER SCHEDULE.

9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.

A1

AE301

A1

AE301

MECHANICAL

ROOM

OPEN TO BELOW

62'-0"

'-7

/8

'-0

A1

AE312

TYP

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

F

LO

O R

P

LA

N

A R

E A

C

DLF

12822605

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE103

SCALE: 1/8" = 1'-0"

FLOOR PLAN - AREA C

1/8" = 1' - 0"

0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

AREA

A

AREA

B

AREA

D

AREA C

V-147

5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

11 EMERGENCY SHOWER AND EYEWASH - REFER TO PLUMBING

12 ROOF ACCESS - METAL LADDER

16 MECHANICAL EQUIPMENT SCREEN WALL, METAL WALL PANEL

24 CONCRETE MECHANICAL PLATFORM OVER STANDING SEAM METAL ROOF

PANELS - REFER TO STRUCTURAL

25 STANDING SEAM METAL ROOF BELOW

32 INTERIOR CONCRETE FILLED STEEL PIPE BOLLARD W/HDPE COVER - SEE

DETAIL A2/AE505

33 ENTRANCE FLOOR MAT AND FRAME OVER RECESSED SLAB - REFER TO

INTERIORS, REFER TO STRUCTURAL

34 METAL ALTERNATING TREAD STAIR SYSTEM - REFER TO STRUCTURAL FOR

INTERMEDIATE LANDING

36 DUCT - REFER TO MECHANICAL

43 EXTERIOR CONCRETE FILLED STEEL PIPE BOLLARD - REFER TO CIVIL

46 BAR GRATING AND SUPPORTS - REFER TO STRUCTURAL FOR

INFORMATION AND DIMENSIONS

47 42" HIGH PLATFORM RAILING - SEE DETAIL C1/AE505

57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION

61 INSULATED EXTERIOR ACCESS DOOR WITH LOCKING T-HANDLE, SEE

DETAIL C1/AE507

63 ROOFTOP MECHANICAL EQUIPMENT - REFER TO MECHANICAL

65 LINE OF PLATFORM ABOVE

SCALE: 1/8" = 1'-0"

FLOOR PLAN - AREA C - ROOF EQUIPMENT PLATFORM

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

C3

C3

AE301

WASH RACK

(PROCESS)

WASH RACK

BAY

DECONTAMINATION

COMM.

FIRE

PROTECTION

CENTRAL

CHEMICAL

STORAGE

WASH RACK

STORAGE

W ATER

TREATMENT

SYSTEM

JAN.

M A

T C

H

LI

N E

A E

LOCKER

ROOM

(DIRTY)

TOILET

TOILET

SOLVENT

STORAGE

AE402

C3

132 133

136A

131B

141 137

144A

133A

B3

AE301

B3

AE301

ELEC.

11 11

FD

FD

144B

44'-4" 117'-2"

'-8

'-8

1'-4" 9'-4" 4'-0" 10'-0"

'-8

2' -4

'-8

'-8

5'-4" 5'-0" 117'-2"

23'-5" 12'-11"

M8R1

M8R1M8R1

19'-8 1/2" 3'-4" 13'-3 1/2" 74'-0" 6'-10"

7'-4" 6'-8"

1'-4" 1'-4"

6'-8" 3'-4" 3'-4" 6'-0" 8'-4" 56'-11" 3'-4" 46'-8" 3'-4" 6'-11"

M8R1

2' -8

'-0

9' -4

3'

-4

'-4

'-0

'-0

'-2

3'

-4

'-2

WASH RACK

EQUIPMENT

CP10CP10

CP14

M12.5

CP14.6

'-1

0"

15'-4" 18'-0" 8'-8"

C L

/8

5'

6"

M12R1.5

M12R1.4

M12R1.4

12'-0" CLR

'-0

C

LR

FEB

FEB

FEB

FEB

FEB

FD

4'-6"

M12.5

/2

M8R1

TYP 32

TYP

'-0

'-0

1' -0

R A

M P

D O

W N

'-0

ABOVE

FD

C J

C J

C J

C J

CJ CJ

A2

AE312

AE412

C2

AE412

B2

CLCL4' - 6" 5' - 0"

C L 5'

0" 36

C L 5'

0"

CLCL 4' - 8" 1' - 2"

TYP 32

4'-2" 8'-10" 4'-2" 34'-1"

4' -2

'-1 0"

4' -2

'-8

2'-4" 4'-2" 2'-4"

C L

5'

0"

CLCL

2' - 6" 5' - 0"

C L 5'

0"

CL

5' - 0"

C L

15 15

CL

4' - 6"

C L C L

4'

8"

'-8

TYP

FD

'-0

'-0

'-4

7'-2"

7'-2"

CP14

FD 24

'-0

TYP

TYP 58

TYP

AE411

A4

AE411

B4

HI

SIM

LO

SIM

A1

AE505

______________TYP

TYP 66

AE411

D1 SIM

TYP AE413

B2 SIM

TYP

TYP

1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR

W ALLS.

2. ALL INTERIOR W ALLS SHALL BE M8, UON.

3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF

EQUIPMENT / SHELVING / CASEW ORK.

4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL

DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,

PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN

W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR

TO COMMENCING THE CONSTRUCTION IN QUESTION.

5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,

HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.

6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.

7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND

STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY

ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.

8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR

GLAZING ELEVATIONS AND LOUVER SCHEDULE.

9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

F

LO

O R

P

LA

N

A R

E A

D

DLF

12822606

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE104

SCALE: 1/8" = 1'-0"

FLOOR PLAN - AREA D

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

AREA

A

AREA

B

AREA

D

AREA C

V-147

2 INSULATED STEEL SLIDING HANGAR DOOR AND RAIL WITH INTEGRAL

DRAINAGE SYSTEM

5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

8 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY

11 EMERGENCY SHOWER AND EYEWASH - REFER TO PLUMBING

15 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 4'-0" X 4'-0"

15K LBS CAPACITY

29 TRENCH DRAIN - REFER TO PLUMBING

31 CONCRETE RAMP - REFER TO STRUCTURAL

32 INTERIOR CONCRETE FILLED STEEL PIPE BOLLARD W/HDPE COVER - SEE

DETAIL A2/AE505

33 ENTRANCE FLOOR MAT AND FRAME OVER RECESSED SLAB - REFER TO

INTERIORS, REFER TO STRUCTURAL

35 CONCRETE SIDEWALK AND EQUIPMENT PAD - REFER TO CIVIL

36 DUCT - REFER TO MECHANICAL

41 6" HIGH X 8" WIDE CONCRETE CURB - PAINTED SAFETY YELLOW

51 TANKS AND EQUIPMENT - REFER TO PLUMBING

53 REFER TO IW SERIES FOR INDUSTRIAL WASTE EQUIPMENT

57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION

58 SLOPE TO DRAIN - REFER TO STRUCTURAL

59 DRAIN - REFER TO STRUCTURAL AND PLUMBING

66 CONCRETE PAVEMENT - REFER TO CIVIL

69 REFER TO TELECOM FOR EXTENTS OF PLYWOOD BACKBOARD

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

TYP 5

TYP

'-6

'-1

'-2

'-1 0"

'-6

'-8

2' -6

/8

10'-0" 16'-0" 26'-0" 14'-0" 20'-0" 20'-0" 5'-6"

8' -4

'-9

'-0

'-3

'-4

7' -0

'-0

'-0

'-8

19'-0"

4'-2"

11'-4"

4'-2"

19'-0"

DS DS

DSDSDSDSDS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DSDSDS

E Q

'-3

'-0

'-9

E

Q

18'-6" 20'-6"

DSDS

26'-0" 1'-8" 27'-6" 30'-6" 23'-0" 17'-0"

DS

DS

DS

DS

DS

DS

DS

DS

DSDS

16'-4"

'-8

'-3

AE105

B3

DSDS DSDS

1. ALL ROOF SLOPES TO BE 1:12, UON.

2. ALL ROOF PENETRATIONS SHALL BE AT THE CENTER OF A ROOF PAN.

STANDING SEAMS SHALL NOT BE DAMAGED OR DISTURBED.

3. MECHANICAL CURB PENETRATIONS SHALL BE CENTERED ON A SEAM IF

GREATER THAN 1'-0" IN W IDTH.

4. ALL ROOF PENETRATIONS SHALL MATCH STANDING SEAM METAL ROOF

COLOR.

5. DOWNSPOUTS ARE 4" X 6" UON.

6. ALL GUTTERS TO BE 6" X 6" AND SLOPE @1/16" PER 12" UON.

7. DOWNSPOUTS THAT DRAIN ONTO ROOF BELOW SHALL BE TURNED TO

DISCHARGE IN THE DIRECTION OF THE ROOF SLOPE BEING DISCHARGED

ONTO.

8. REFER TO DETAIL B1/AE505 FOR DOWNSPOUT BOOT AND STRAP

CONNECTION DETAIL.

9. PROVIDE CRICKETS AT ALL ROOFTOP MECHANICAL EQUIPMENT.

TYP5

TYP12

TYP12

DS

DS DSDS

DS

DSDS

DSDSDSDS

DS DS DS DS

16'-9 3/4" 18'-0" 18'-0"5' -7

7'

-0

EQ 20'-0" 20'-0" 20'-0" EQ

EQ 20'-0" 20'-0" 20'-0" EQ

DS

CLR

3'-0"

C

LR

4' -0

CLR

4'-0"

8' -0

TYP18

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

O V

E R

A

LL

R O

O F

P

LA

N

DLF

12822607

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE105

SCALE: 3/64" = 1'-0"

OVERALL ROOF PLAN

1/8" = 1' - 0"

0 5' 10' 15' 30'

3/64" = 1' - 0" 0 10' 20' 40' 80'5'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

AREA

A

AREA

B

AREA

D

AREA C

V-147

3 HANGAR ROD SUPPORTED CANOPY - 6'-4" WIDE x 5'-0" DEEP, UON

4 PREFINISHED METAL GUTTER WITH DOWNSPOUTS BELOW - SEE

ELEVATIONS

5 ROOFTOP MECHANICAL EQUIPMENT - REFER TO MECHANICAL

6 16" WIDE STANDING SEAM METAL ROOF PANELS

7 HIGH ROOF ACCESS - METAL LADDER - PROVIDE OSHA COMPLIANT,

SPRING-LOADED SWING GATE AT TOP OF LADDER

8 INSULATED ROOF ACCESS HATCH 3' X 5'-4" - SEE DETAIL C1/AE502

10 GUARDRAIL EXTENSION 6'-0" MIN FROM ROOF EDGE

12 SPLASH PAN ON LOW ROOF - PROVIDE BEND IN DOWNSPOUT TO ALIGN

OUTFALL TO ROOF SLOPE

13 EXTEND DOWNSPOUT OUTLET TO DISCHARGE ONTO SECOND ROOF

PANEL

14 FABRICATED ROOF PANEL ASSEMBLY RIDGE CAP

15 ROOFTOP FREESTANDING GUARDRAIL

16 RAINWATER DIVERTER BY STANDING SEAM METAL PANEL ROOF MFR

17 SPLIT GUTTER AT ROOFTOP LADDER AND DRAIN TO ADJACENT

DOWNSPOUTS

18 1/4" PER 12" MIN SLOPE CRICKET - BY STANDING SEAM METAL PANEL ROOF

MFR

SCALE: 1/8" = 1'-0" (AE105)

B3

ENLARGED ROOF PLAN @ MECHANICAL ROOM

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

WASH RACK

(PROCESS)

WASH RACK

BAY

DECONTAMINATION

COMM.

FIRE

PROTECTION

MECHANICAL

ROOM

PMB BAY

PAINT BAY

PAINT BAY

(PROCESS)

PAINT BAY

SUPPLY AIR

PLENUM

PAINT BAY

EXHAUST

AIR PLENUM

PMB BAY

(PROCESS)

PMB BAY

SUPPLY AIR

PLENUM

PMB BAY

EXHAUST

AIR PLENUM

BLAST

MEDIA

RECOVERY

BLAST

MEDIA

STORAGE

PAINT

MIXING

PAINT

STORAGE

ELEC.

FILTER

STORAGE

ADMIN

BREAK

ISSUE

WOMEN'S

LOCKER

ROOM

(CLEAN)

AIR DRY

CORR.

CENTRAL

CHEMICAL

STORAGE

PMB BAY

(PROCESS)

PAINT BAY

(PROCESS)

TOOL CRIB

CORR.

WASH RACK

STORAGE

COMM.

CORR.

LOCKER

ROOM

(DIRTY)

MEN'S

LOCKER

ROOM

(CLEAN)

COMPRESSOR

ROOM

MOTHER'S

ROOM

W ATER

TREATMENT

SYSTEM

JAN.

MATERIAL

STORAGE

STENCIL

ROOM

EQUIPMENT

CLEANING

LOCKER

ROOM

(DIRTY)

TOILET

TOILET

SOLVENT

STORAGE

ADMIN

CLOSET

PMB

STORAGE

MECH

ELEC.

WASH RACK

EQUIPMENT

AE111

AE112

AE112

AE113

A E

A E

AIR LOCK

DUST

COLLECTOR

YARD

CHILLER

YARD

1. REFER TO SHEET A-001 FOR RCP LEGEND

2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.

3. HVAC & LIGHTING FIXTURES SHOW N ARE FOR GRAPHIC PURPOSES ONLY.

GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP

DRAW INGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY

CONFLICTS OR DISCREPANCIES.

4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD

FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.

5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON

RCP DRAW INGS PRIOR TO INSTALLATION OF ALL MECHANICAL

DUCTW ORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,

ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF

LIGHT FIXTURES, REGISTERS, & GRILLES.

7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT

DIMENSIONS, UON.

8. W HERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO

MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO

BE LOCATED IN THE CENTER OF THE TILE.

9. W HERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS

SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL

JOINTS IN GWB W ALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND

B4/AE511.

10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION

DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE

LOCATED WITHIN GWB SOFFITS.

11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

O V

E R

A

LL

R E

FL

E

C

TE

D C

E

IL

IN

G

P

LA

N

DLF

12822608

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE110

SCALE: 3/64" = 1'-0"

OVERALL REFLECTED CEILING PLAN

3/64" = 1' - 0"

0 10' 20' 40' 80'5'

GRAPHIC SCALE(S)

KEY PLAN

GENERAL NOTES

AREA

A

AREA

B

AREA

D

AREA C

V-147

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

OS

OS

OS OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OS

OS

OS

S

S

S

S

S

S

S S

S

S

PMB BAY

PMB BAY

(PROCESS)

114B

PMB BAY

SUPPLY AIR

PLENUM

114C

PMB BAY

EXHAUST

AIR PLENUM

BLAST

MEDIA

RECOVERY

BLAST

MEDIA

STORAGE

WOMEN'S

LOCKER

ROOM

(CLEAN)

AIR DRY

CORR.

PMB BAY

(PROCESS)

114A

CORR.

COMM.

LOCKER

ROOM

(DIRTY)

COMPRESSOR

ROOM

JAN.

CORR.

EXP

EXP

EXP

EXP

EXP

EXP

PMB

STORAGE

MATCHLINE

AE112

MATCHLINE

AE112

22'-0"

9'-0"

10'-0"

17'-0"

10'-4"

10'-4"

10'-1"

9'-0"

9'-0"

10'-4"

17'-0"

TYP

TYP

8'-0"

9'-0"

TYP

8'-6"

8'-0"

8'-6"

MEN'S

LOCKER

ROOM

(CLEAN)

FILTER

STORAGE

ELEC.

EXP

'-0

'-0

'-0

3'

-8

10'-4"

11'-0"

11'-0"

10'-4"

11'-0"

10'-4"

D4

C4

D4

C4

C2

D2

C2

D2 TYP

'-0

6' -1

0" 5'

-0

'-0

5'

-0

7' -1

70'-0" 14'-8"

8'-0"

D1

8'-6"7'-5"

7'-5"9'-0"

8'-6"

B1

B1 D1

8'-0"

11'-0"

C2

10'-4"

9'-0" 9'-0"

1' -8

1'

-8

D1

C2

C2

9'-0"

DUST

COLLECTOR

YARD

A3

B3

B3

A3

C5

D5 HI

LO

10'-1"

17'-0" 8'-6"

22'-0"

CJ

CJ

CJ

CJCJ CJ

ALIGN ALIGN ALIGN

1. REFER TO SHEET A-001 FOR RCP LEGEND

2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.

3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.

GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP

DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY

CONFLICTS OR DISCREPANCIES.

4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD

FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.

5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON

RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL

DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,

ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF

LIGHT FIXTURES, REGISTERS, & GRILLES.

7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT

DIMENSIONS, UON.

8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO

MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO

BE LOCATED IN THE CENTER OF THE TILE.

9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS

SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL

JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND

B4/AE511.

10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION

DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE

LOCATED WITHIN GWB SOFFITS.

11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

R E

FL

E

C

TE

D C

E

IL

IN

G

P

LA

N

A R

E A

A

DLF

12822609

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE111

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - AREA A

AREA

A

AREA

B

AREA

D

AREA C

V-147

3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

4 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY

6 OVERHEAD COILING DOOR HOOD

9 WALL MOUNTED AIR CONDITIONER UNIT - REFER TO MECHANICAL

10 UNIT HEATER - REFER TO MECHANICAL

11 METAL PANEL CEILING AT PMB AND PAINT BAYS

15 BID OPTION - ACOUSTICAL CEILING TILE AT HIGH CEILING ONLY [PANEL

SIZE: 2" THICK PANELS. NOMINAL 2'x2' DIMENSION TO FIT LAY-IN METAL

15/16” T-GRID CEILING GRID. PANEL FACING: FIBERGLASS OR MINERAL

WOOL PANEL WILL BE COVERED WITH 1 MIL (NOMINAL) FIBERGLASS

REINFORCED WHITE MYLAR. PANEL WILL BE COMPLETELY ENCAPSULATED,

WRAPPED ON ALL SIDES. PANEL WILL BE TEAR AND PUNCTURE RESISTANT

AND CLEANABLE. CORE: 6-7LB PCF FIBERGLASS OR MINERAL WOOL.

ACOUSTICAL PERFORMANCE: NOISE REDUCTION COEFFICIENT (NRC) = 0.90

OR HIGHER WHEN TESTED PER ASTM C423 WITH TYPE A OR E-400

MOUNTING (MOUNTING PER ASTM E795). FLAMMABILITY: PRODUCT

COMPONENTS CLASS A FIRE RATED PER ASTM E84]

17 OVERHEAD COILING DOOR MOTOR

18 PLATFORM, SEE ENLARGED PLAN ON A4/AE404 - REFER TO STRUCTURAL

19 LIGHTS AND EQUIPMENT SHOWN BELOW PLATFORM

20 PLATFORM, SEE ENLARGED PLAN ON B1/AE404 - REFER TO STRUCTURAL

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

OS OS

OS

OS

OS

OS

OS

PS

OS

PS

OS

OS

OS

S

S

S

S

S

S

S

S

S

S

S

MATCHLINE

AE111

MATCHLINE

AE113

PAINT BAY

CORR.

PAINT BAY

EXHAUST

AIR PLENUM

AIR LOCK

BREAK

EXP

EXP

MATCHLINE

AE111

MATCHLINE

AE113

32'-6"

10'-0"

9'-6"

27'-6"

9'-0"

10'-4" 11'-6"

27'-4"

27'-4"

9'-0"

PAINT BAY

STORAGE

120C

10'-0"

10'-4"

11'-0"

D4

C4

D4

C4

A1

A1

8' -2

6'

-0

5' -2

'-0

5' -2

6'

-0

8' -5

18'-8"81'-0"

'-2

'-0

'-0

'-0

'-6

D1 8'-6"

5' -6

8'-6"

9'-0" C2

C2

8'-0"

ISSUE

MECH

104A

MEN'S

LOCKER

ROOM

(CLEAN)

11'-0"

11'-0"

11'-0"

10'-4"

11'-0"

AIR LOCK

120E

D5 C5HI LO

D5 C5HI LO

D5

C5

HI

LO

A3

A3

B3

B3

32'-0"

CJ

CJ

CJ

1. REFER TO SHEET A-001 FOR RCP LEGEND

2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.

3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.

GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP

DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY

CONFLICTS OR DISCREPANCIES.

4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD

FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.

5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON

RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL

DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,

ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF

LIGHT FIXTURES, REGISTERS, & GRILLES.

7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT

DIMENSIONS, UON.

8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO

MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO

BE LOCATED IN THE CENTER OF THE TILE.

9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS

SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL

JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND

B4/AE511.

10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION

DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE

LOCATED WITHIN GWB SOFFITS.

11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

R E

FL

E

C

TE

D C

E

IL

IN

G

P

LA

N

A R

E A

B

DLF

12822610

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE112

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - AREA B

AREA

A

AREA

B

AREA

D

AREA C

V-147

3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

4 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY

5 RIGID RAIL FOR AIRCRAFT HANGAR WITH TROLLEY SYSTEM - REFER TO

STRUCTURAL FOR BEAM INFORMATION

11 METAL PANEL CEILING AT PMB AND PAINT BAYS

15 BID OPTION - ACOUSTICAL CEILING TILE AT HIGH CEILING ONLY [PANEL

SIZE: 2" THICK PANELS. NOMINAL 2'x2' DIMENSION TO FIT LAY-IN METAL

15/16” T-GRID CEILING GRID. PANEL FACING: FIBERGLASS OR MINERAL

WOOL PANEL WILL BE COVERED WITH 1 MIL (NOMINAL) FIBERGLASS

REINFORCED WHITE MYLAR. PANEL WILL BE COMPLETELY ENCAPSULATED,

WRAPPED ON ALL SIDES. PANEL WILL BE TEAR AND PUNCTURE RESISTANT

AND CLEANABLE. CORE: 6-7LB PCF FIBERGLASS OR MINERAL WOOL.

ACOUSTICAL PERFORMANCE: NOISE REDUCTION COEFFICIENT (NRC) = 0.90

OR HIGHER WHEN TESTED PER ASTM C423 WITH TYPE A OR E-400

MOUNTING (MOUNTING PER ASTM E795). FLAMMABILITY: PRODUCT

COMPONENTS CLASS A FIRE RATED PER ASTM E84]

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

OS

OS

PS

OS

PS

OS

OS

OS OS OS

OS

OS

OS

S

S

S

SSS S

S

S

S

S

S

S

ADMIN

ADMIN

CLOSET

101A

MOTHER'S

ROOM

TOOL CRIB

EQUIPMENT

CLEANING

STENCIL

ROOM

MATERIAL

STORAGE

PAINT

STORAGE

PAINT

MIXING

CORR.

MECHANICAL

ROOM

11'-8"

11'-0"11'-0" 11'-0"

10'-4" 10'-4"

10'-4"

10'-4"

9'-6"

10'-0"

10'-0" EXP

EXP

EXP

EXP

EXP

EXP

MATCHLINE

AE112

MATCHLINE

AE112

MATCHLINE

AE114

9'-0"

11'-8"

11'-0"

10'-4"

C4

D4

D4 D4

C4 C4

C2

16'-0" 16'-0"

'-6

'-0

'-0

CORR.

11'-0"

1. REFER TO SHEET A-001 FOR RCP LEGEND

2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.

3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.

GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP

DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY

CONFLICTS OR DISCREPANCIES.

4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD

FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.

5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON

RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL

DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,

ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF

LIGHT FIXTURES, REGISTERS, & GRILLES.

7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT

DIMENSIONS, UON.

8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO

MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO

BE LOCATED IN THE CENTER OF THE TILE.

9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS

SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL

JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND

B4/AE511.

10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION

DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE

LOCATED WITHIN GWB SOFFITS.

11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

R E

FL

E

C

TE

D C

E

IL

IN

G

P

LA

N

A R

E A

C

DLF

12822611

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE113

1/8" = 1' - 0"

0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

AREA

A

AREA

B

AREA

D

AREA C

V-147

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - AREA C

3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

6 OVERHEAD COILING DOOR HOOD

7 METAL ALTERNATING TREAD STAIR SYSTEM - REFER TO STRUCTURAL FOR

INTERMEDIATE LANDING

10 UNIT HEATER - REFER TO MECHANICAL

14 DO NOT MOUNT CANOPY TO SIDE WALL

17 OVERHEAD COILING DOOR MOTOR

21 PLATFORM, SEE PLAN ON AE103 - REFER TO STRUCTURAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

OS OS

OS

S

S

SS

S

S

JAN.

TOILET

TOILET

LOCKER

ROOM

(DIRTY)

DECONTAMINATION

WASH RACK

STORAGE

CENTRAL

CHEMICAL

STORAGE

SOLVENT

STORAGE

COMM.

FIRE

PROTECTION

WATER

TREATMENT

SYSTEM

WASH RACK

(PROCESS)

WASH RACK

BAY

EXP

EXP

EXP

EXP

EXP

EXP

MATCHLINE

AE113

29'-10"

9'-0"

9'-0" 11'-8"

11'-8"

EXP

EXP

EXP

EXP

ELEC.

11'-0"

WASH RACK

EQUIPMENT

42'-8"

EXP

TYP

C2

A1

A1

B2 A2

TYP

29'-10"

'-8

/4

C3

1. REFER TO SHEET A-001 FOR RCP LEGEND

2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.

3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.

GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP

DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY

CONFLICTS OR DISCREPANCIES.

4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD

FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.

5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON

RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL

DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,

ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF

LIGHT FIXTURES, REGISTERS, & GRILLES.

7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT

DIMENSIONS, UON.

8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO

MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO

BE LOCATED IN THE CENTER OF THE TILE.

9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS

SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL

JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND

B4/AE511.

10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION

DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE

LOCATED WITHIN GWB SOFFITS.

11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.

VIRGINIA BEACH, VA 23462

SUITE 1400

757·455·5800 FAX 757·455·5638

WWW.CLARKNEXSEN.COM

4525 MAIN STREET

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAW ING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAW FORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

N40085-19-D-9041

1614720

1 2 3 4 5

Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center

Mid-Atlantic, via Email.

14 Sept 2020

P -1

C

O R

R O

S

IO

N C

O N

T R

O L

P

A

IN

T F

A C

IL

IT

Y

R E

FL

E

C

TE

D C

E

IL

IN

G

P

LA

N

A R

E A

D

DLF

12822612

CJL SRN/NRS

SDS/RSF

N O

R F

O

LK

, V

IR

G

IN

IA

N

A V

A L

S T

A T

IO

N

N O

R F

O

LK

EJA

DJD

DSN

AE114

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - AREA D

AREA

A

AREA

B

AREA

D

AREA C

V-147

3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS

IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN

CMU WALL.

4 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY

5 RIGID RAIL FOR AIRCRAFT HANGAR WITH TROLLEY SYSTEM - REFER TO

STRUCTURAL FOR BEAM INFORMATION

8 LOW ROOF ACCESS - METAL LADDER

9 WALL MOUNTED AIR CONDITIONER UNIT - REFER TO MECHANICAL

10 UNIT HEATER - REFER TO MECHANICAL

12 METAL SOFFIT PANELS

13 INTAKE LOUVER PENTHOUSE - REFER TO MECHANICAL

16 MTL PLATE CLOSURE BY SLIDING HANGAR DOOR MFR

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENER…

This is the start of the file's text. The full file is on GovTribe.