1614720dwg07of16_ArchitecturalR.pdf
PDF 19 MB Posted
- Solicitation number
- N4008521R2507
About this file
This document provides details on a federal solicitation notice for an Indefinite-Delivery, Indefinite-Quantity, Multiple Award Construction Contract for facilities in the Hampton Roads Area of Responsibility in Virginia. The solicitation is being conducted by the Naval Facilities Engineering Command and seeks design-build and design-bid-build construction services on an IDIQ basis. Offerors will be eligible to compete for task orders for large general construction projects primarily in the Hampton Roads Area, including design services where applicable. The solicitation number is N4008521R2507 and responses are due based on the posting date.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AND&
EXIST EXISTING
VINYL COMPOSITION TILEVCT
AFS
ADJ
AT
APPROX
AFF
BD
ALUM
APPROXIMATE
BOARD
ABOVE FINISH FLOOR
ABOVE FINISH SLAB
ALUMINUM
ADJUSTABLE, ADJUST
CEILING
COL
CLG
DIA
CMU
CONC
DOW NDN
EQUIP
ELEC
ELEV
EQUIPMENT
ELECTRICAL
ELEVATION
CONCRETE MASONRY UNIT
CONCRETE
DIAMETER
COLUMN
FLOOR
FO
FLR
GWB GYPSUM WALLBOARD
FACE OF
EQ EQUAL
CENTER LINE
HORIZ HORIZONTAL
TYPICALTYP
TOC TOP OF CONCRETE
W IDTH / WASHER
VERT
W
VERTICAL
UNLESS OTHERWISE NOTEDUON
HOLLOW METALHM
VIF VERIFY IN FIELD
CL
ALT ALTERNATE
APC ARCHITECTURAL PRECAST CONCRETE
ACT ACOUSTICAL CEILING TILE
BLDG BUILDING
BLKG BLOCKING
BRG BEARING
BUR BUILT-UP ROOFING
CORNER GUARDCG
CONTROL JOINTCJ
CLEARCLR
CONST CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
D DEPTH / DRYER
DBL DOUBLE
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DOWNSPOUTDS
DRAW INGDWG
EACHEA
EXPANSION JOINTEJ
EDGE OF SLABEOS
EPS EXPANDED POLYSTYRENE
EXP EXPANSION / EXPOSED
EXT EXTERIOR
FD FLOOR DRAIN
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
FGL FIBERGLASS
FF FINISH FLOOR
FIN FINISH
FP FIRE PROTECTION
GA GAUGE
GALV GALVANIZED
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GYP GYPSUM
HDW HARDWARE
HI HIGH
HT HEIGHT
HVAC HEATING, VENTILATION, & AIR
CONDITIONING
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JBE JOIST BEARING ELEVATION
L LENGTH / LONG
MATL MATERIAL
SUSPENDEDSUSP
THR THRESHOLD
TOW TOP OF W ALL
TP TOILET PARTITION
TOP & BOTTOMT & B
VINYL BASEVB
VTR VENT THRU ROOF
W ITHW/
W ITHOUTW/O
W ALLCOVERINGW C
WOODWD
WINDOWWDW
WINDOW OPENINGWO
WORK POINTWP
WEIGHTW T
EXTRUDED POLYSTYRENEXPS
METALMTL
NIC
MISC
OC
MISCELLANEOUS
ON CENTER
NOT IN CONTRACT
ROOM
SIMILAR
R
RM
REF
SIM
RO
SS
RADIUS
STAINLESS STEEL
ROUGH OPENING
REFRIGERATOR
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MO MASONRY OPENING
MTG MOUNTING
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED
OFOI OWNER FURNISHED
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
PL PLATE
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PR PAIR
PTD PAINTED
RD ROOF DRAIN
REINF REINFORCING
REQ'D REQUIRED
RWL RAIN WATER LEADER
SAB SOUND ATTENUATING BLANKET
SF SQUARE FEET
SQUARESQ
STRUCTURALSTRUCT
STD STANDARD
STL STEELCONTRACTOR INSTALLED
OWNER INSTALLED
TTL TOTAL
PH PANIC HARDWARE
KO KNOCK OUT
GC GENERAL CONTRACTOR
IGU INSULATING GLASS UNIT
POLYISO POLYISOCYANURATE
INSULATION
FRT FIRE RETARDANT TREATED
TELE TELECOMMUNICATION
SAFB SOUND ATTENUATING FIRE BLANKETS
JT JOINT
PMB PLASTIC MEDIA BLASTING
HDWD HARDWOOD
LO LOW
PT PRESSURE TREATED
AT/FP ANTI-TERRORISM / FORCE PROTECTION
CONCRETE WOOD BLOCKING - INTERRUPTED
BRICK
CONCRETE MASONRY UNIT
(CMU)
INSULATION - BATT /
LOOSE / BLANKET
PLYWOOD / MDF
EARTH
W OOD BLOCKING /
FRAMING - CONTINUOUS
INSULATION - RIGID
POROUS FILL
INSULATION - SPRAY FOAM
GWB / PLASTER / GROUT /
SPRAY FIREPROOFING
STEEL
A
A1
AE201
A1
AE201
A3
A2A4
NEW WORK KEYNOTE
PARTITION / W ALL TYPE
DETAIL / PLAN NUMBER
SHEET WHERE SHOW N
ELEVATION NUMBER
SHEET WHERE SHOWN
XX.X
ELEVATION DATUM
+12'-0"
FIRST FLOOR
ROOM DESIGNATION
DIRECTION OF SLOPE
ROOF SLOPE
FLOOR DRAIN
FIRE
EXTINGUISHER
CABINET
FIRE
EXTINGUISHER
BRACKET
FD
DETAIL, SECTION,
ELEVATION TITLE
DETAIL / ENLARGED PLAN
PLAN TITLE
AND NORTH ARROW
INTERIOR ELEVATION
EXTERIOR ELEVATION
ELEVATION NUMBER
SHEET WHERE SHOWN
BUILDING SECTION
SECTION NUMBER
SHEET WHERE SHOW N
DETAIL / W ALL SECTION
DOOR NUMBER12
AE301
A1
AE301
A1
AE301
A1
A1
AE101
W INDOW / STOREFRONT
DESIGNATION
REVISION TAG
FEC FEB
A1 / AE101
ADJACENT AREA
REFERENCE
W 1 S1
SPECIALTY ITEM DESIGNATION
MATCHLINE
BUILDING
SHEET WHERE SHOW N
SECTION NUMBER
NAME
SCALE:A1
NAME
SCALE:
TRUE NORTH INDICATOR
PLAN NORTH INDICATOR
ROOM NAME
LOUVER / TRANSLUCENT PANEL
DESIGNATION
L1 K1
PAIR OF DOORS
INACTIVE LEAF (TOP
AND BTM BOLTS)
ACTIVE LEAF
(REFERENCING SHEET)
GWB
CEILING / SOFFIT
METAL PANEL
SOFFIT
OS
S
H P
FIRE ALARM STROBE / FIRE ALARM HORN STROBE
SPEAKER / SPEAKER W/ STROBE
CEILING MOUNTED
OCCUPANCY SENSOR
CARBON MONOXIDE SENSOR
HEAT SENSOR / PHOTO SENSOR
SMOKE DETECTOR
CEILING HEIGHTEXPOSED CEILING
INDICATES BRACKET, WALL MOUNTED
FIRE PROTECTION FIXTURE / EQUIPMENT, ETC
CEILING MOUNTED RECEPTACLE
CO
8'-0"
S
S
EXP
SUPPLY GRILLE / RETURN GRILLE
V F
EXHAUST FAN
CEILING MOUNTED SECURITY CAMERA
ACCESS PANEL
2' x 2' METAL PANEL
CEILING
CEILING MOUNTED
EXIT LIGHT
CEILING MOUNTED
EXIT LIGHT W / ARROW
LIGHT FIXTURE EMERGENCY EGRESS LIGHT FIXTURE
INDICATES BRACKET, WALL MOUNTED
ELECTRICAL LIGHT / FIXTURE / EQUIPMENT, ETC
SPRINKLER HEAD
2' x 4' ACT CEILING
PS
CEILING MOUNTED
DAYLIGHTING SENSOR
FRP CEILING
WALL MOUNTED ACU
1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF MASONRY, AND TO CENTERLINE OF
COLUMNS.
2. ALL NOTES, DETAILS, AND FEATURES DRAWN AS APPLICABLE FOR ONE CONDITION ARE APPLICABLE TO SIMILAR
CONDITIONS, W HETHER OR NOT SPECIFICALLY INDICATED.
3. IN STUD WALLS, LOCATE ALL INTERIOR DOOR FRAMES A DISTANCE OF 4" (FOUR) INCHES FROM THE THROAT RETURN TO THE CLOSEST ADJACENT PERPENDICULAR PARTITION, UON. IN CMU AND PRECAST W ALLS, LOCATE MASONRY
OPENING AT DOORS 8" (EIGHT) FROM THE PERPENDICULAR W ALL.
4. ALL ELEVATIONS ARE MEASURED FROM THE REFERENCE ELEVATION +0'-0", WHICH IS THE TOP OF THE FIRST FLOOR
SLAB, UON.
5. DO NOT SCALE DRAW INGS TO DETERMINE DIMENSIONS OR SIZES OF BUILDING ELEMENTS.
6. ALL W OOD BLOCKING AND MISCELLANEOUS STEEL SHOW N IN DETAILS AND SECTIONS SHALL BE CONTINUOUS, UON.
7. USE FIRE-RETARDANT TREATED W OOD PRODUCTS FOR ALL CONCEALED WOOD BLOCKING, UON.
8. USE PRESERVATIVE-TREATED W OOD PRODUCTS FOR ALL WOOD BLOCKING IN CONTACT WITH EXTERIOR MASONRY OR CONCRETE W ALLS, AND FOR ALL W OOD BLOCKING IN CONTACT W ITH CONCRETE SLABS ON GRADE.
9. VERIFY ALL DIMENSIONS. BRING ANY DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.
10. NOTIFY ARCHITECT OF ANY DISCREPANCY BETWEEN DRAWINGS AND SPECIFICATIONS
11. PROVIDE W OOD OR METAL BLOCKING BEHIND GW B AT THE FOLLOWING LOCATIONS:
A. ALL W ALL-MOUNTED OR CEILING-MOUNTED DOOR STOPS, DOOR HOLD-OPEN DEVICES, AND OTHER HARDW ARE.
B. ALL W ALL-MOUNTED TOILET ACCESSORIES. AT GRAB BARS, PROVIDE BLOCKING CAPABLE OF RESISTING A MINIMUM LOAD OF 250 POUNDS APPLIED VERTICALLY OR HORIZONTALLY AT ANY POINT ON THE GRAB BAR.
C. ALL W ALL-MOUNTED PLUMBING FIXTURES, INCLUDING BUT NOT LIMITED TO LAVATORIES, SINKS, URINALS, WATER CLOSETS, AND W ATER COOLERS. PROVIDE BLOCKING CAPABLE OF RESISTING A MINIMUM LOAD OF 400 POUNDS
APPLIED VERTICALLY AT ANY POINT ON THE PLUMBING FIXTURE.
D. ALL W ALL-MOUNTED CABINETRY, SHELVING, AND SIMILAR ITEMS.
E. ALL W ALL-MOUNTED VIDEO MONITORS, AND SIMILAR ITEMS.
12. ALL MATERIALS USED IN THE PROJECT SHALL BE NEW AND PROVIDED BY THE CONTRACTOR, UON.
13. USE BITUMINOUS MEMBRANE TO SEPARATE PRESERVATIVE-TREATED W OOD PRODUCTS FROM CONTACT W ITH ANY
METAL SURFACE.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
A R
C H
IT
E
C
TU
R A
L
LE
G E
N D
S A
N D
N O
TE
S
DLF
12822601
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
A-001
ARCHITECTURAL GENERAL NOTES
ARCHITECTURAL ABBREVIATIONS
ARCHITECTURAL SYMBOLOGY
MATERIAL LEGEND
RCP LEGEND
NOT ALL ABBREVIATIONS, SYMBOLS, AND LEGEND
GRAPHICS LISTED ARE NECESSARILY USED ON THIS
PROJECT. REFER TO DOCUMENTS FOR SPECIFIC
INFORMATION.
E
LE
C T
R
IC
A L
F
IR
E P
R O
T E
C T
IO
N
A R
C H
IT
E
C T
U R
A L
M E
C H
A N
IC
A
L
FLOOR PLAN LEGEND
BID OPTIONS
• LIFT TABLES @ PMB BAY
- REFER TO SHEET AE101
• LIFT TABLES @ PAINT BAY
- REFER TO SHEET AE102
• LIFT TABLES @ WASH BAY
- REFER TO SHEET AE104
• TRANSLUCENT PANELS @ WASH BAY
- REFER TO SHEETS AE201 AND AE203
• ACOUSTICAL PANELS @ PMB BAY
- REFER TO SHEETS AE111
• ACOUSTICAL PANELS @ PAINT BAY
- REFER TO SHEETS AE112
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
AE203
D1
AE204
D1
AE201
D1
AE202
D1
WASH RACK
(PROCESS)
WASH RACK
BAY
DECONTAMINATION
COMM.
FIRE
PROTECTION
MECHANICAL
ROOM
PMB BAY
PAINT BAY
PAINT BAY
(PROCESS)
PAINT BAY
SUPPLY AIR
PLENUM
PAINT BAY
EXHAUST
AIR PLENUM
PMB BAY
(PROCESS)
PMB BAY
SUPPLY AIR
PLENUM
PMB BAY
EXHAUST
AIR PLENUM
BLAST
MEDIA
RECOVERY
BLAST
MEDIA
STORAGE
PAINT
MIXING
PAINT
STORAGE
ADMIN
WOMEN'S
LOCKER
ROOM
(CLEAN)
AIR DRY
CORR.
CENTRAL
CHEMICAL
STORAGE
PMB BAY
(PROCESS)
PAINT BAY
(PROCESS)
TOOL CRIB
CORR.
WASH RACK
STORAGE
COMM.
CORR.
LOCKER
ROOM
(DIRTY)
MEN'S
LOCKER
ROOM
(CLEAN)
COMPRESSOR
ROOM
MOTHER'S
ROOM
W ATER
TREATMENT
SYSTEM
JAN.
CHILLER
YARD
SOLVENT
STORAGE
LOCKER
ROOM
(DIRTY)
EQUIPMENT
CLEANING
STENCIL
ROOM
MATERIAL
STORAGE
JAN.
TOILET
TOILET
AIR LOCK
ELEC.
PMB
STORAGE
FILTER
STORAGE
ADMIN
CLOSET
BREAK
ISSUE
MECH
ELEC.
AE101
AE102
AE102
AE103
A E
A E
274'-6"
2' -4
'-8
9' -4
1' -4
44'-4" 117'-2"
26'-0" 82'-0" 44'-4" 2'-4" 119'-10"
23'-11 5/8" 89'-0 3/8"
9'
-8
9'
-8
'-0
1' -0
'-0
'-8
274'-6"
'-1
0"
'-0
40'-0" 32'-8"
WASH RACK
EQUIPMENT
PAINT BAY
STORAGE
AE404
A1
'-8
DUST
COLLECTOR
YARD
AE404
C1
ABOVE
AE404
A3
ABOVE
53'-2" 56'-8" 42'-6"
AIR LOCK
1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF
MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR
W ALLS.
2. ALL INTERIOR W ALLS SHALL BE M8, UON.
3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF
EQUIPMENT / SHELVING / CASEW ORK.
4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL
DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,
PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN
W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR
TO COMMENCING THE CONSTRUCTION IN QUESTION.
5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD
PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,
HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.
6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF
DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.
7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND
STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY
ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.
8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR
GLAZING ELEVATIONS AND LOUVER SCHEDULE.
9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
O V
E R
A
LL
F
LO
O R
P
LA
N
DLF
12822602
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE100SCALE: 3/64" = 1'-0"
OVERALL FLOOR PLAN
3/64" = 1' - 0"
0 10' 20' 40' 80'5'
GRAPHIC SCALE(S)
KEY PLAN
GENERAL NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
A1
AE301
A1
AE301
FILTER
STORAGE
PMB BAY
PMB BAY
(PROCESS)
114B
PMB BAY
SUPPLY AIR
PLENUM
114C
PMB BAY
EXHAUST
AIR PLENUM
BLAST
MEDIA
RECOVERY
BLAST
MEDIA
STORAGE
ELEC.
WOMEN'S
LOCKER
ROOM
(CLEAN)
AIR DRY
CORR.
PMB BAY
(PROCESS)
114A
CORR.
COMM.
LOCKER
ROOM
(DIRTY)
MEN'S
LOCKER
ROOM
(CLEAN)
COMPRESSOR
ROOM
MATCHLINE
AE102
MATCHLINE
AE102
C1
AE301
______________ C1
AE301
JAN.
AE402
A3
115 114A
111B
112111
114C
114B
113B
111A
110A 113A
1A
PMB
STORAGE
TYP22
AIR LOCK
FD
FD
FD FD
FD
'-0
7'
-2
/2
2' -2
'-6
2' -2
6'
-0
/2
6' -8
'-0
8' -8
'-4
9'-2" 12'-0" 12'-2" 6'-0" 85'-6" 4'-4"
'-1
0" 9'
-1
'-8
4'
-0
9' -2
'-1 1"
10'-2 3/8" 12'-0"
9 5/8"
9'-2" 18'-2 3/8" 24'-0" 21'-0"
26'-0" 82'-0" 44'-4"
6' -8
'-1 0"
9' -2
9'
-4
6' -0
8'
-0
4' -4
2' -0
CP14R1
CP10R2
CP14
M12
M12
CP10R2
M12
CP14
M12
CP10R1
CP10R1
M8R1
AE403
A3
AE402
A1
131C
AE411
A4
6' -8
2' -0
8' -0
2'
-8
2' -8
8'
-0
2' -8
'-0
2' -0
8'
-0
'-0
4'
-8
4' -0
2'
-8
6' -8
2'
-0
'-0
3'-7" 6'-8" 11'-11" 6'-0"
8' -0
E
Q 3'
-2
1' -3
3' -2
1' -3
3' -2
E
Q 8'
-0
6'-0" 11'-7" 64'-0" 9'-1" 5'-6"
8" 6'-8" 6'-0" 8'-0" 2'-8" 6'-8" 6'-8" 5'-4" 20'-0" 19'-4"
4" 14'-0" 10'-0" 2'-0" 16'-0" 2'-0"
1'-4" 8" 3'-4" 6'-8" 12'-2" 2" EJ 1'-8"
3' -4
'-0
1' -7
3' -4
2' -3
/2
2'
-0
/2
3' -4
8"
W 1
PAINT BAY
1' -8
3'
-4
2' -0
3' -4
1' -8
9' -8
3'
-4
8"
M12
'-5
C
LR
W
ID
T
H
'-0
6' -0
C
LR
FEB
FEBFEC
FEB
FEB
1' -4
1' -8
1'-8"
1'-8"
41'-0"
6' -8
6'
-0
3' -4
6'
-0
1' -4
1'
-4
L10
L9
TYP
CP14.7
CP14.7
CP14.7
CP14.7
FDFD
AE412
A4
AE412
B4
27'-2" 25'-10" 29'-0"
6' -8
2'
-0
TYP
C J
C J
C J
C J
C J
CJ
C
J
CJ CJ
CJ CJ
C J
4' -7
/8
6' -8
'-8
1' -8
3'
-4
4"
AE505
D2
10'-11" 4'-2" 11'-4" 4'-2" 9'-4" 4'-2" 19'-11"
12'-0" DRIVE
A1
AE314
4'-0"
4'-0"
A2
AE314
56'-8"
'-0
'-4
4' -8
'-8
AE412
B1
DUST
COLLECTOR
YARD
C J
2'-0" 17'-8" 17'-4" 17'-8" 2'-0"
'-8
CJ CJ CJ CJ
C J
C J
112A
112B
L4
L3
ABOVE
ABOVE
CJ
CL
13' - 6"
CL
2' - 6" 15' - 10"
TYP
AE505
D2
C L 1'
0"
FEB
TYP52
3' -4
8'
-1 1"
TYP 55
AE412
B1 SIM
CENTERED ON
SERVICE DOOR
(REFER TO CIVIL)
12'-0" DRIVE
CENTERED ON
SERVICE DOOR
(REFER TO CIVIL)
2'-0"
FEB FEB
CJ
CL1' - 0"
1' -8
6'-0" 6'-0" 10"
AE412
C1
LO
HI
LO
AE412
C1
SIM
HI
SIM
AE411
B4
LO
HI
C
LR
3' -6
2'-4"
TYP57
AE413
A3
EQ EQ EQ EQ EQ EQ
A1
AE505
______________TYP
AE411
D1 SIM
TYP
AE413
A2 HI
LO
AE413
B2 SIM
TYP
C1
AE504
'-1
0"
TYP69
1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF
MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR
W ALLS.
2. ALL INTERIOR W ALLS SHALL BE M8, UON.
3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF
EQUIPMENT / SHELVING / CASEW ORK.
4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL
DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,
PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN
W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR
TO COMMENCING THE CONSTRUCTION IN QUESTION.
5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD
PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,
HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.
6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF
DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.
7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND
STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY
ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.
8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR
GLAZING ELEVATIONS AND LOUVER SCHEDULE.
9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
F
LO
O R
P
LA
N
A R
E A
A
DLF
12822603
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE101
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
SCALE: 1/8" = 1'-0"
FLOOR PLAN - AREA A
AREA
A
AREA
B
AREA
D
AREA C
V-147
1A SWINGING PLENUM HANGAR DOOR 21'-3"W X 22'-0"H
4 METAL GRATE FLOORING - REFER TO STRUCTURAL
5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
8 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY
9 PLENUM FILTER WALL - REFER TO MECHANICAL
13 LINE OF PLATFORM ABOVE, SEE ENLARGED PLAN A3/AE404
22 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 3'-0" X 4'-0"
8K LBS CAPACITY
23 EMERGENCY EYEWASH - REFER TO PLUMBING
32 INTERIOR CONCRETE FILLED STEEL PIPE BOLLARD W/HDPE COVER - SEE
DETAIL A2/AE505
33 ENTRANCE FLOOR MAT AND FRAME OVER RECESSED SLAB - REFER TO
INTERIORS, REFER TO STRUCTURAL
35 CONCRETE SIDEWALK AND EQUIPMENT PAD - REFER TO CIVIL
43 EXTERIOR CONCRETE FILLED STEEL PIPE BOLLARD - REFER TO CIVIL
45 PLATFORM ACCESS - METAL LADDER, EXTEND 42" ABOVE PLATFORM
52 PLASTIC MEDIA BARRELS - BY OWNER
55 THRU-WALL SCUPPER, 1'-4" W X 8" H - COORDINATE OUTFALL ABOVE GRADE
56 NOTCH SLAB AROUND SCUPPERS - SEE DETAIL C1/AE504 - REFER TO CIVIL
57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION
60 EDGE OF EQUIPMENT PLATFORM ABOVE
64 LINE OF PLATFORM ABOVE, SEE ENLARGED PLAN B1/AE404
66 CONCRETE PAVEMENT - REFER TO CIVIL
69 REFER TO TELECOM FOR EXTENTS OF PLYWOOD BACKBOARD
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
A1
AE301
MATCHLINE
AE101
MATCHLINE
AE103
MATCHLINE
AE101
PAINT BAY
PAINT BAY
(PROCESS)
120A
PAINT BAY
SUPPLY AIR
PLENUM
120C
PAINT BAY
EXHAUST
AIR PLENUM
BREAK
ISSUE
PAINT BAY
(PROCESS)
120B
MEN'S
LOCKER
ROOM
(CLEAN)
B1
AE301
______________ B1
AE301
AIR LOCK
103A
120A
120B
119A
122 123 124
MECH
104A 104A
1B
9 8
MATCHLINE
AE103
FD
FD
FD
FD
FD
103B
121A
9' -4
'-4
'-4
22'-11" 30'-4" 62'-5" 4'-4"
22'-2 3/8" 9 5/8" 9'-2" 15'-2" 100'-6" 4'-4"
9' -1
'-9
6' -1
8'
-1 0"
'-9
1'-4" 2'-0"
8' -2
'-1 1"
'-0
CP14R2
CP10CP10
CP14R2
M8R1FS3.1
M12
M8R1
M12
CP14R2
AE402
A1
2' -0
'-0
2' -0
2'
-0
'-0
2'
-0
'-0
'-0
'-8
8'
-0
4'-3" 4'-4" 7'-8" 6'-8" 2'-3" 4'-4" 1'-8" 6'-0"
2'-4"
6' -6
/2
'-6
6' -8
/2
2' -4
3'
-4
2' -2
/2
7' -1
1/
2"
2' -2
'-0
2' -2
7'
-8
/2
AE403
B1
S1
S1
W 2
M8FS3.1
AE413
B3
2' -0
5'
-4
4" 3'
-4
1' -8
4"
3' -4
1'
-8
4" 6'
-8
4" 4"
4' -8
4'
-8
3' -4
1'
-8
'-1
1" C
LR
W
ID
T
H
120C
PAINT BAY
STORAGE
120C
10'-4"
CP14.6
CP10CP10CP10R2
CP10R2
2' -1
/2
3'
-4
2' -1
1"
FEC
FEBFEB
FEB
FEB
FEB
FEB
1'-4"
M8FS3.1
CP14.6
C J
C J
C J
C J
C J
4' -8
'-4
'-0
'-8
A1
AE302
______________ A1
AE302
C1
AE302
C1
AE302
A1
AE303
______________ A1
AE303
C1
AE303
C1
AE303
44'-3" 4'-2" 4'-10" 4'-2" 2'-4" 4'-2" 9'-4" 4'-2" 10" 4'-2"
4' -2
2'
-1 0"
3' -2
2'
-1 0"
4' -2
'-1
/2
3'
-2
5' -8
3'
-2
'-4
/2
2' -7
'-0
2' -7
20'-0"
19'-0"
120E
AIR LOCK
120E
121B
8' -5
E Q
E Q
TYP 57
A1
AE505
______________TYP
AE411
D1 SIM
TYP
AE413
B2 SIM
TYP
'-4
1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF
MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR
W ALLS.
2. ALL INTERIOR W ALLS SHALL BE M8, UON.
3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF
EQUIPMENT / SHELVING / CASEW ORK.
4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL
DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,
PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN
W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR
TO COMMENCING THE CONSTRUCTION IN QUESTION.
5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD
PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,
HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.
6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF
DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.
7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND
STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY
ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.
8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR
GLAZING ELEVATIONS AND LOUVER SCHEDULE.
9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
F
LO
O R
P
LA
N
A R
E A
B
DLF
12822604
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE102
SCALE: 1/8" = 1'-0"
FLOOR PLAN - AREA B
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
1B SWINGING PLENUM HANGAR DOOR 40'-6"W X 32'-0"H
5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
8 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY
9 PLENUM FILTER WALL - REFER TO MECHANICAL
10 DUAL HEIGHT ELECTRIC WATER COOLER W/ BOTTLE FILLER, SEE SHEET
AE401 FOR TYPICAL ACCESSORY MOUNTING HEIGHTS - REFER TO
PLUMBING
11 EMERGENCY SHOWER AND EYEWASH - REFER TO PLUMBING
15 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 4'-0" X 4'-0"
15K LBS CAPACITY
20 SINK WITH INTEGRAL DRAIN BOARDS - REFER TO PLUMBING
22 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 3'-0" X 4'-0"
8K LBS CAPACITY
57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
A1
AE301
MATCHLINE
AE102
MATCHLINE
AE104
MATCHLINE
AE102
MECHANICAL
ROOM
PAINT
MIXING
PAINT
STORAGE
ADMIN
TOOL CRIB
EQUIPMENT
CLEANING
STENCIL
ROOM
MATERIAL
STORAGE
MOTHER'S
ROOM
ADMIN
CLOSET
101A
CORR.
101A 122A
122B
124A
124123122
CORR.
123A
129A
131B
129B
FD
FD
18'-6" 10'-0" 2'-8"
'-4
9'
-4
1' -4
'-2
'-8
'-4
'-6
'-4
'-4
9'
-4
5'-0"
9' -2
1'-4" 22'-2 3/8"
9 5/8"
9'-2" 18'-6" 12'-8" 8'-8" 15'-4" 26'-8" 3'-4" 27'-0"
2' -0
/8
7' -3
/8
'-4
23'-11 5/8" 89'-0 3/8"
M4
M8FS3.2
M12
M8R1FS3.1
M12
M8R1
M8R1
M8R1
M8R1
M12R1
M12
M4
M4AE411
A2
AE411
D4 131A
4'-0" 16'-0"
3'-11 5/8"
10'-8" 5'-4"
2'-0"
16'-0"
2'-0"
6'-0" 6'-8" 6'-0"
2'-0"
16'-0"
2'-0"
2' -0
2'
-0
'-0
2'
-0
'-8
AE403
A1
6' -8
3'
-4
2' -8
2'
-8
'-0
2'
-8
'-4
E
Q E
Q
M4.3
S1
S1
S1 S1
5' -4
6'
-8
1'-4"
'-4
4" 3'
-4
1' -8
M4
M4
6'-8" 4'-8" EQ EQ
M A
T C
H
LI
N E
A E
FD
FEC
FEC
1'-8"
1'-4"
1' -8
FEB
FEB
TYP
TYP
M4.3
M4
TYP
C J
C J
CJ CJ CJ CJ
C J
C J
5' -4
'-8
2' -0
TYP
1'-4"
T Y
P 1'
-4
2'-0"
M4
M4
2'-0"
7' -0
5' -0
AE505
D2
TYP
14'-4 3/8"
2" E
J
12'-2 3/8" 10'-0" 9'-2"9 5/8"
SIM
9' -4
AE411
B2
LO
HI
1' -4
TYP 57
C L C L
6'
0"
FD
S4
S3
5'-0"
33 33
AE411
D1 SIM
TYP
1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF
MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR
W ALLS.
2. ALL INTERIOR W ALLS SHALL BE M8, UON.
3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF
EQUIPMENT / SHELVING / CASEW ORK.
4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL
DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,
PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN
W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR
TO COMMENCING THE CONSTRUCTION IN QUESTION.
5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD
PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,
HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.
6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF
DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.
7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND
STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY
ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.
8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR
GLAZING ELEVATIONS AND LOUVER SCHEDULE.
9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.
A1
AE301
A1
AE301
MECHANICAL
ROOM
OPEN TO BELOW
62'-0"
'-7
/8
'-0
A1
AE312
TYP
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
F
LO
O R
P
LA
N
A R
E A
C
DLF
12822605
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE103
SCALE: 1/8" = 1'-0"
FLOOR PLAN - AREA C
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
11 EMERGENCY SHOWER AND EYEWASH - REFER TO PLUMBING
12 ROOF ACCESS - METAL LADDER
16 MECHANICAL EQUIPMENT SCREEN WALL, METAL WALL PANEL
24 CONCRETE MECHANICAL PLATFORM OVER STANDING SEAM METAL ROOF
PANELS - REFER TO STRUCTURAL
25 STANDING SEAM METAL ROOF BELOW
32 INTERIOR CONCRETE FILLED STEEL PIPE BOLLARD W/HDPE COVER - SEE
DETAIL A2/AE505
33 ENTRANCE FLOOR MAT AND FRAME OVER RECESSED SLAB - REFER TO
INTERIORS, REFER TO STRUCTURAL
34 METAL ALTERNATING TREAD STAIR SYSTEM - REFER TO STRUCTURAL FOR
INTERMEDIATE LANDING
36 DUCT - REFER TO MECHANICAL
43 EXTERIOR CONCRETE FILLED STEEL PIPE BOLLARD - REFER TO CIVIL
46 BAR GRATING AND SUPPORTS - REFER TO STRUCTURAL FOR
INFORMATION AND DIMENSIONS
47 42" HIGH PLATFORM RAILING - SEE DETAIL C1/AE505
57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION
61 INSULATED EXTERIOR ACCESS DOOR WITH LOCKING T-HANDLE, SEE
DETAIL C1/AE507
63 ROOFTOP MECHANICAL EQUIPMENT - REFER TO MECHANICAL
65 LINE OF PLATFORM ABOVE
SCALE: 1/8" = 1'-0"
FLOOR PLAN - AREA C - ROOF EQUIPMENT PLATFORM
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
C3
C3
AE301
WASH RACK
(PROCESS)
WASH RACK
BAY
DECONTAMINATION
COMM.
FIRE
PROTECTION
CENTRAL
CHEMICAL
STORAGE
WASH RACK
STORAGE
W ATER
TREATMENT
SYSTEM
JAN.
M A
T C
H
LI
N E
A E
LOCKER
ROOM
(DIRTY)
TOILET
TOILET
SOLVENT
STORAGE
AE402
C3
132 133
136A
131B
141 137
144A
133A
B3
AE301
B3
AE301
ELEC.
11 11
FD
FD
144B
44'-4" 117'-2"
'-8
'-8
1'-4" 9'-4" 4'-0" 10'-0"
'-8
2' -4
'-8
'-8
5'-4" 5'-0" 117'-2"
23'-5" 12'-11"
M8R1
M8R1M8R1
19'-8 1/2" 3'-4" 13'-3 1/2" 74'-0" 6'-10"
7'-4" 6'-8"
1'-4" 1'-4"
6'-8" 3'-4" 3'-4" 6'-0" 8'-4" 56'-11" 3'-4" 46'-8" 3'-4" 6'-11"
M8R1
2' -8
'-0
9' -4
3'
-4
'-4
'-0
'-0
'-2
3'
-4
'-2
WASH RACK
EQUIPMENT
CP10CP10
CP14
M12.5
CP14.6
'-1
0"
15'-4" 18'-0" 8'-8"
C L
/8
5'
6"
M12R1.5
M12R1.4
M12R1.4
12'-0" CLR
'-0
C
LR
FEB
FEB
FEB
FEB
FEB
FD
4'-6"
M12.5
/2
M8R1
TYP 32
TYP
'-0
'-0
1' -0
R A
M P
D O
W N
'-0
ABOVE
FD
C J
C J
C J
C J
CJ CJ
A2
AE312
AE412
C2
AE412
B2
CLCL4' - 6" 5' - 0"
C L 5'
0" 36
C L 5'
0"
CLCL 4' - 8" 1' - 2"
TYP 32
4'-2" 8'-10" 4'-2" 34'-1"
4' -2
'-1 0"
4' -2
'-8
2'-4" 4'-2" 2'-4"
C L
5'
0"
CLCL
2' - 6" 5' - 0"
C L 5'
0"
CL
5' - 0"
C L
15 15
CL
4' - 6"
C L C L
4'
8"
'-8
TYP
FD
'-0
'-0
'-4
7'-2"
7'-2"
CP14
FD 24
'-0
TYP
TYP 58
TYP
AE411
A4
AE411
B4
HI
SIM
LO
SIM
A1
AE505
______________TYP
TYP 66
AE411
D1 SIM
TYP AE413
B2 SIM
TYP
TYP
1. PLAN DIMENSIONS SHOW N ARE TO FACE OF FRAMING MEMBERS, FACE OF
MASONRY, AND TO CENTER LINE OF COLUMNS, EXCLUSIVE OF INTERIOR
W ALLS.
2. ALL INTERIOR W ALLS SHALL BE M8, UON.
3. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION OF
EQUIPMENT / SHELVING / CASEW ORK.
4. ANY CONFLICTING INFORMATION BETW EEN THE ARCHITECTURAL
DRAW INGS AND THE CIVIL, LANDSCAPE, STRUCTURAL, FIRE PROTECTION,
PLUMBING, HVAC, OR ELECTRICAL DRAW INGS SHALL BE NOTED IN
W RITING TO THE ARCHITECT FOR REVIEW AND MUST BE CLARIFIED PRIOR
TO COMMENCING THE CONSTRUCTION IN QUESTION.
5. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD
PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING,
HARDW ARE, DOOR STOPS AND OTHER EQUIPMENT.
6. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF
DECK AND PARTITIONS WITH PM&E AND FP DRAW INGS.
7. VERIFY AND COORDINATE FINISH FLOOR ELEVATIONS WITH CIVIL AND
STRUCTURAL PRIOR TO COMMENCING CONSTRUCTION. NOTIFY
ARCHITECT IN WRITING BEFORE CONSTRUCTION OF ANY CONFLICTS.
8. REFER TO SHEET AE601 FOR DOOR SCHEDULE AND SHEET AE602 FOR
GLAZING ELEVATIONS AND LOUVER SCHEDULE.
9. REFER TO P,M,E AND FP SHEETS FOR EQUIPMENT NOT NOTED ON PLANS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
F
LO
O R
P
LA
N
A R
E A
D
DLF
12822606
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE104
SCALE: 1/8" = 1'-0"
FLOOR PLAN - AREA D
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
2 INSULATED STEEL SLIDING HANGAR DOOR AND RAIL WITH INTEGRAL
DRAINAGE SYSTEM
5 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
8 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY
11 EMERGENCY SHOWER AND EYEWASH - REFER TO PLUMBING
15 BID OPTION - RECESSED MECHANICALLY ACTUATED LIFT TABLE, 4'-0" X 4'-0"
15K LBS CAPACITY
29 TRENCH DRAIN - REFER TO PLUMBING
31 CONCRETE RAMP - REFER TO STRUCTURAL
32 INTERIOR CONCRETE FILLED STEEL PIPE BOLLARD W/HDPE COVER - SEE
DETAIL A2/AE505
33 ENTRANCE FLOOR MAT AND FRAME OVER RECESSED SLAB - REFER TO
INTERIORS, REFER TO STRUCTURAL
35 CONCRETE SIDEWALK AND EQUIPMENT PAD - REFER TO CIVIL
36 DUCT - REFER TO MECHANICAL
41 6" HIGH X 8" WIDE CONCRETE CURB - PAINTED SAFETY YELLOW
51 TANKS AND EQUIPMENT - REFER TO PLUMBING
53 REFER TO IW SERIES FOR INDUSTRIAL WASTE EQUIPMENT
57 DOWNSPOUT - REFER TO CIVIL FOR CONTINUATION
58 SLOPE TO DRAIN - REFER TO STRUCTURAL
59 DRAIN - REFER TO STRUCTURAL AND PLUMBING
66 CONCRETE PAVEMENT - REFER TO CIVIL
69 REFER TO TELECOM FOR EXTENTS OF PLYWOOD BACKBOARD
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
TYP 5
TYP
'-6
'-1
'-2
'-1 0"
'-6
'-8
2' -6
/8
10'-0" 16'-0" 26'-0" 14'-0" 20'-0" 20'-0" 5'-6"
8' -4
'-9
'-0
'-3
'-4
7' -0
'-0
'-0
'-8
19'-0"
4'-2"
11'-4"
4'-2"
19'-0"
DS DS
DSDSDSDSDS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DSDSDS
E Q
'-3
'-0
'-9
E
Q
18'-6" 20'-6"
DSDS
26'-0" 1'-8" 27'-6" 30'-6" 23'-0" 17'-0"
DS
DS
DS
DS
DS
DS
DS
DS
DSDS
16'-4"
'-8
'-3
AE105
B3
DSDS DSDS
1. ALL ROOF SLOPES TO BE 1:12, UON.
2. ALL ROOF PENETRATIONS SHALL BE AT THE CENTER OF A ROOF PAN.
STANDING SEAMS SHALL NOT BE DAMAGED OR DISTURBED.
3. MECHANICAL CURB PENETRATIONS SHALL BE CENTERED ON A SEAM IF
GREATER THAN 1'-0" IN W IDTH.
4. ALL ROOF PENETRATIONS SHALL MATCH STANDING SEAM METAL ROOF
COLOR.
5. DOWNSPOUTS ARE 4" X 6" UON.
6. ALL GUTTERS TO BE 6" X 6" AND SLOPE @1/16" PER 12" UON.
7. DOWNSPOUTS THAT DRAIN ONTO ROOF BELOW SHALL BE TURNED TO
DISCHARGE IN THE DIRECTION OF THE ROOF SLOPE BEING DISCHARGED
ONTO.
8. REFER TO DETAIL B1/AE505 FOR DOWNSPOUT BOOT AND STRAP
CONNECTION DETAIL.
9. PROVIDE CRICKETS AT ALL ROOFTOP MECHANICAL EQUIPMENT.
TYP5
TYP12
TYP12
DS
DS DSDS
DS
DSDS
DSDSDSDS
DS DS DS DS
16'-9 3/4" 18'-0" 18'-0"5' -7
7'
-0
EQ 20'-0" 20'-0" 20'-0" EQ
EQ 20'-0" 20'-0" 20'-0" EQ
DS
CLR
3'-0"
C
LR
4' -0
CLR
4'-0"
8' -0
TYP18
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
O V
E R
A
LL
R O
O F
P
LA
N
DLF
12822607
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE105
SCALE: 3/64" = 1'-0"
OVERALL ROOF PLAN
1/8" = 1' - 0"
0 5' 10' 15' 30'
3/64" = 1' - 0" 0 10' 20' 40' 80'5'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
3 HANGAR ROD SUPPORTED CANOPY - 6'-4" WIDE x 5'-0" DEEP, UON
4 PREFINISHED METAL GUTTER WITH DOWNSPOUTS BELOW - SEE
ELEVATIONS
5 ROOFTOP MECHANICAL EQUIPMENT - REFER TO MECHANICAL
6 16" WIDE STANDING SEAM METAL ROOF PANELS
7 HIGH ROOF ACCESS - METAL LADDER - PROVIDE OSHA COMPLIANT,
SPRING-LOADED SWING GATE AT TOP OF LADDER
8 INSULATED ROOF ACCESS HATCH 3' X 5'-4" - SEE DETAIL C1/AE502
10 GUARDRAIL EXTENSION 6'-0" MIN FROM ROOF EDGE
12 SPLASH PAN ON LOW ROOF - PROVIDE BEND IN DOWNSPOUT TO ALIGN
OUTFALL TO ROOF SLOPE
13 EXTEND DOWNSPOUT OUTLET TO DISCHARGE ONTO SECOND ROOF
PANEL
14 FABRICATED ROOF PANEL ASSEMBLY RIDGE CAP
15 ROOFTOP FREESTANDING GUARDRAIL
16 RAINWATER DIVERTER BY STANDING SEAM METAL PANEL ROOF MFR
17 SPLIT GUTTER AT ROOFTOP LADDER AND DRAIN TO ADJACENT
DOWNSPOUTS
18 1/4" PER 12" MIN SLOPE CRICKET - BY STANDING SEAM METAL PANEL ROOF
MFR
SCALE: 1/8" = 1'-0" (AE105)
B3
ENLARGED ROOF PLAN @ MECHANICAL ROOM
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
WASH RACK
(PROCESS)
WASH RACK
BAY
DECONTAMINATION
COMM.
FIRE
PROTECTION
MECHANICAL
ROOM
PMB BAY
PAINT BAY
PAINT BAY
(PROCESS)
PAINT BAY
SUPPLY AIR
PLENUM
PAINT BAY
EXHAUST
AIR PLENUM
PMB BAY
(PROCESS)
PMB BAY
SUPPLY AIR
PLENUM
PMB BAY
EXHAUST
AIR PLENUM
BLAST
MEDIA
RECOVERY
BLAST
MEDIA
STORAGE
PAINT
MIXING
PAINT
STORAGE
ELEC.
FILTER
STORAGE
ADMIN
BREAK
ISSUE
WOMEN'S
LOCKER
ROOM
(CLEAN)
AIR DRY
CORR.
CENTRAL
CHEMICAL
STORAGE
PMB BAY
(PROCESS)
PAINT BAY
(PROCESS)
TOOL CRIB
CORR.
WASH RACK
STORAGE
COMM.
CORR.
LOCKER
ROOM
(DIRTY)
MEN'S
LOCKER
ROOM
(CLEAN)
COMPRESSOR
ROOM
MOTHER'S
ROOM
W ATER
TREATMENT
SYSTEM
JAN.
MATERIAL
STORAGE
STENCIL
ROOM
EQUIPMENT
CLEANING
LOCKER
ROOM
(DIRTY)
TOILET
TOILET
SOLVENT
STORAGE
ADMIN
CLOSET
PMB
STORAGE
MECH
ELEC.
WASH RACK
EQUIPMENT
AE111
AE112
AE112
AE113
A E
A E
AIR LOCK
DUST
COLLECTOR
YARD
CHILLER
YARD
1. REFER TO SHEET A-001 FOR RCP LEGEND
2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.
3. HVAC & LIGHTING FIXTURES SHOW N ARE FOR GRAPHIC PURPOSES ONLY.
GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP
DRAW INGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY
CONFLICTS OR DISCREPANCIES.
4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD
FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.
5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON
RCP DRAW INGS PRIOR TO INSTALLATION OF ALL MECHANICAL
DUCTW ORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,
ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF
LIGHT FIXTURES, REGISTERS, & GRILLES.
7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT
DIMENSIONS, UON.
8. W HERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO
MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO
BE LOCATED IN THE CENTER OF THE TILE.
9. W HERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS
SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL
JOINTS IN GWB W ALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND
B4/AE511.
10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION
DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE
LOCATED WITHIN GWB SOFFITS.
11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
O V
E R
A
LL
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
DLF
12822608
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE110
SCALE: 3/64" = 1'-0"
OVERALL REFLECTED CEILING PLAN
3/64" = 1' - 0"
0 10' 20' 40' 80'5'
GRAPHIC SCALE(S)
KEY PLAN
GENERAL NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
OS
OS
OS OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
S
S
S
S
S
S
S S
S
S
PMB BAY
PMB BAY
(PROCESS)
114B
PMB BAY
SUPPLY AIR
PLENUM
114C
PMB BAY
EXHAUST
AIR PLENUM
BLAST
MEDIA
RECOVERY
BLAST
MEDIA
STORAGE
WOMEN'S
LOCKER
ROOM
(CLEAN)
AIR DRY
CORR.
PMB BAY
(PROCESS)
114A
CORR.
COMM.
LOCKER
ROOM
(DIRTY)
COMPRESSOR
ROOM
JAN.
CORR.
EXP
EXP
EXP
EXP
EXP
EXP
PMB
STORAGE
MATCHLINE
AE112
MATCHLINE
AE112
22'-0"
9'-0"
10'-0"
17'-0"
10'-4"
10'-4"
10'-1"
9'-0"
9'-0"
10'-4"
17'-0"
TYP
TYP
8'-0"
9'-0"
TYP
8'-6"
8'-0"
8'-6"
MEN'S
LOCKER
ROOM
(CLEAN)
FILTER
STORAGE
ELEC.
EXP
'-0
'-0
'-0
3'
-8
10'-4"
11'-0"
11'-0"
10'-4"
11'-0"
10'-4"
D4
C4
D4
C4
C2
D2
C2
D2 TYP
'-0
6' -1
0" 5'
-0
'-0
5'
-0
7' -1
70'-0" 14'-8"
8'-0"
D1
8'-6"7'-5"
7'-5"9'-0"
8'-6"
B1
B1 D1
8'-0"
11'-0"
C2
10'-4"
9'-0" 9'-0"
1' -8
1'
-8
D1
C2
C2
9'-0"
DUST
COLLECTOR
YARD
A3
B3
B3
A3
C5
D5 HI
LO
10'-1"
17'-0" 8'-6"
22'-0"
CJ
CJ
CJ
CJCJ CJ
ALIGN ALIGN ALIGN
1. REFER TO SHEET A-001 FOR RCP LEGEND
2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.
3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.
GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP
DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY
CONFLICTS OR DISCREPANCIES.
4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD
FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.
5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON
RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL
DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,
ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF
LIGHT FIXTURES, REGISTERS, & GRILLES.
7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT
DIMENSIONS, UON.
8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO
MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO
BE LOCATED IN THE CENTER OF THE TILE.
9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS
SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL
JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND
B4/AE511.
10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION
DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE
LOCATED WITHIN GWB SOFFITS.
11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
A R
E A
A
DLF
12822609
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE111
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - AREA A
AREA
A
AREA
B
AREA
D
AREA C
V-147
3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
4 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY
6 OVERHEAD COILING DOOR HOOD
9 WALL MOUNTED AIR CONDITIONER UNIT - REFER TO MECHANICAL
10 UNIT HEATER - REFER TO MECHANICAL
11 METAL PANEL CEILING AT PMB AND PAINT BAYS
15 BID OPTION - ACOUSTICAL CEILING TILE AT HIGH CEILING ONLY [PANEL
SIZE: 2" THICK PANELS. NOMINAL 2'x2' DIMENSION TO FIT LAY-IN METAL
15/16” T-GRID CEILING GRID. PANEL FACING: FIBERGLASS OR MINERAL
WOOL PANEL WILL BE COVERED WITH 1 MIL (NOMINAL) FIBERGLASS
REINFORCED WHITE MYLAR. PANEL WILL BE COMPLETELY ENCAPSULATED,
WRAPPED ON ALL SIDES. PANEL WILL BE TEAR AND PUNCTURE RESISTANT
AND CLEANABLE. CORE: 6-7LB PCF FIBERGLASS OR MINERAL WOOL.
ACOUSTICAL PERFORMANCE: NOISE REDUCTION COEFFICIENT (NRC) = 0.90
OR HIGHER WHEN TESTED PER ASTM C423 WITH TYPE A OR E-400
MOUNTING (MOUNTING PER ASTM E795). FLAMMABILITY: PRODUCT
COMPONENTS CLASS A FIRE RATED PER ASTM E84]
17 OVERHEAD COILING DOOR MOTOR
18 PLATFORM, SEE ENLARGED PLAN ON A4/AE404 - REFER TO STRUCTURAL
19 LIGHTS AND EQUIPMENT SHOWN BELOW PLATFORM
20 PLATFORM, SEE ENLARGED PLAN ON B1/AE404 - REFER TO STRUCTURAL
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
OS OS
OS
OS
OS
OS
OS
PS
OS
PS
OS
OS
OS
S
S
S
S
S
S
S
S
S
S
S
MATCHLINE
AE111
MATCHLINE
AE113
PAINT BAY
CORR.
PAINT BAY
EXHAUST
AIR PLENUM
AIR LOCK
BREAK
EXP
EXP
MATCHLINE
AE111
MATCHLINE
AE113
32'-6"
10'-0"
9'-6"
27'-6"
9'-0"
10'-4" 11'-6"
27'-4"
27'-4"
9'-0"
PAINT BAY
STORAGE
120C
10'-0"
10'-4"
11'-0"
D4
C4
D4
C4
A1
A1
8' -2
6'
-0
5' -2
'-0
5' -2
6'
-0
8' -5
18'-8"81'-0"
'-2
'-0
'-0
'-0
'-6
D1 8'-6"
5' -6
8'-6"
9'-0" C2
C2
8'-0"
ISSUE
MECH
104A
MEN'S
LOCKER
ROOM
(CLEAN)
11'-0"
11'-0"
11'-0"
10'-4"
11'-0"
AIR LOCK
120E
D5 C5HI LO
D5 C5HI LO
D5
C5
HI
LO
A3
A3
B3
B3
32'-0"
CJ
CJ
CJ
1. REFER TO SHEET A-001 FOR RCP LEGEND
2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.
3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.
GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP
DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY
CONFLICTS OR DISCREPANCIES.
4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD
FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.
5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON
RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL
DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,
ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF
LIGHT FIXTURES, REGISTERS, & GRILLES.
7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT
DIMENSIONS, UON.
8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO
MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO
BE LOCATED IN THE CENTER OF THE TILE.
9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS
SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL
JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND
B4/AE511.
10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION
DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE
LOCATED WITHIN GWB SOFFITS.
11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
A R
E A
B
DLF
12822610
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE112
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - AREA B
AREA
A
AREA
B
AREA
D
AREA C
V-147
3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
4 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY
5 RIGID RAIL FOR AIRCRAFT HANGAR WITH TROLLEY SYSTEM - REFER TO
STRUCTURAL FOR BEAM INFORMATION
11 METAL PANEL CEILING AT PMB AND PAINT BAYS
15 BID OPTION - ACOUSTICAL CEILING TILE AT HIGH CEILING ONLY [PANEL
SIZE: 2" THICK PANELS. NOMINAL 2'x2' DIMENSION TO FIT LAY-IN METAL
15/16” T-GRID CEILING GRID. PANEL FACING: FIBERGLASS OR MINERAL
WOOL PANEL WILL BE COVERED WITH 1 MIL (NOMINAL) FIBERGLASS
REINFORCED WHITE MYLAR. PANEL WILL BE COMPLETELY ENCAPSULATED,
WRAPPED ON ALL SIDES. PANEL WILL BE TEAR AND PUNCTURE RESISTANT
AND CLEANABLE. CORE: 6-7LB PCF FIBERGLASS OR MINERAL WOOL.
ACOUSTICAL PERFORMANCE: NOISE REDUCTION COEFFICIENT (NRC) = 0.90
OR HIGHER WHEN TESTED PER ASTM C423 WITH TYPE A OR E-400
MOUNTING (MOUNTING PER ASTM E795). FLAMMABILITY: PRODUCT
COMPONENTS CLASS A FIRE RATED PER ASTM E84]
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
OS
OS
PS
OS
PS
OS
OS
OS OS OS
OS
OS
OS
S
S
S
SSS S
S
S
S
S
S
S
ADMIN
ADMIN
CLOSET
101A
MOTHER'S
ROOM
TOOL CRIB
EQUIPMENT
CLEANING
STENCIL
ROOM
MATERIAL
STORAGE
PAINT
STORAGE
PAINT
MIXING
CORR.
MECHANICAL
ROOM
11'-8"
11'-0"11'-0" 11'-0"
10'-4" 10'-4"
10'-4"
10'-4"
9'-6"
10'-0"
10'-0" EXP
EXP
EXP
EXP
EXP
EXP
MATCHLINE
AE112
MATCHLINE
AE112
MATCHLINE
AE114
9'-0"
11'-8"
11'-0"
10'-4"
C4
D4
D4 D4
C4 C4
C2
16'-0" 16'-0"
'-6
'-0
'-0
CORR.
11'-0"
1. REFER TO SHEET A-001 FOR RCP LEGEND
2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.
3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.
GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP
DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY
CONFLICTS OR DISCREPANCIES.
4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD
FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.
5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON
RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL
DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,
ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF
LIGHT FIXTURES, REGISTERS, & GRILLES.
7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT
DIMENSIONS, UON.
8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO
MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO
BE LOCATED IN THE CENTER OF THE TILE.
9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS
SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL
JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND
B4/AE511.
10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION
DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE
LOCATED WITHIN GWB SOFFITS.
11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
A R
E A
C
DLF
12822611
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE113
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - AREA C
3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
6 OVERHEAD COILING DOOR HOOD
7 METAL ALTERNATING TREAD STAIR SYSTEM - REFER TO STRUCTURAL FOR
INTERMEDIATE LANDING
10 UNIT HEATER - REFER TO MECHANICAL
14 DO NOT MOUNT CANOPY TO SIDE WALL
17 OVERHEAD COILING DOOR MOTOR
21 PLATFORM, SEE PLAN ON AE103 - REFER TO STRUCTURAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
OS OS
OS
S
S
SS
S
S
JAN.
TOILET
TOILET
LOCKER
ROOM
(DIRTY)
DECONTAMINATION
WASH RACK
STORAGE
CENTRAL
CHEMICAL
STORAGE
SOLVENT
STORAGE
COMM.
FIRE
PROTECTION
WATER
TREATMENT
SYSTEM
WASH RACK
(PROCESS)
WASH RACK
BAY
EXP
EXP
EXP
EXP
EXP
EXP
MATCHLINE
AE113
29'-10"
9'-0"
9'-0" 11'-8"
11'-8"
EXP
EXP
EXP
EXP
ELEC.
11'-0"
WASH RACK
EQUIPMENT
42'-8"
EXP
TYP
C2
A1
A1
B2 A2
TYP
29'-10"
'-8
/4
C3
1. REFER TO SHEET A-001 FOR RCP LEGEND
2. REFER TO SHEET AE511 AND AE512 FOR CEILING DETAILS.
3. HVAC & LIGHTING FIXTURES SHOWN ARE FOR GRAPHIC PURPOSES ONLY.
GC TO REFER TO P,M,E DRAWINGS AND SPRINKLER PIPING SHOP
DRAWINGS AND SHOULD NOTIFY ARCHITECT IMMEDIATELY OF ANY
CONFLICTS OR DISCREPANCIES.
4. GENERAL CONTRACTOR TO COORDINATE ALL SOFFIT/ BULKHEAD
FRAMING WITH FINAL LIGHTING FIXTURES & HVAC DIFFUSER LOCATIONS.
5. GENERAL CONTRACTOR TO FIELD VERIFY CEILING HEIGHTS SHOWN ON
RCP DRAWINGS PRIOR TO INSTALLATION OF ALL MECHANICAL
DUCTWORK, SPRINKLER PIPING, ELECTRICAL EQUIPMENT, CONDUITS,
ETC. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
6. GENERAL CONTRACTOR TO INSTALL WIRE HANGERS @ ALL CORNERS OF
LIGHT FIXTURES, REGISTERS, & GRILLES.
7. ALL RECESSED LIGHTING SHALL BE CENTERED WITHIN THE SOFFIT
DIMENSIONS, UON.
8. WHERE ACT IS LOCATED, ALL FIXTURES INCLUDING BUT NOT LIMITED TO
MOTION DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS, ARE TO
BE LOCATED IN THE CENTER OF THE TILE.
9. WHERE GWB SOFFITS SPAN LONGER THAN 30'-0", CONTROL JOINTS
SHOULD BE LOCATED IN GWB SOFFIT EVERY 30'-0". ALIGN WITH CONTROL
JOINTS IN GWB WALLS WHERE PRESENT. SEE DETAILS A4/AE511 AND
B4/AE511.
10. IN CORRIDOR 131, NO FIXTURES INCLUDING BUT NOT LIMITED TO MOTION
DETECTORS, FIRE ALARM DEVICES, & SPRINKLER HEADS ARE TO BE
LOCATED WITHIN GWB SOFFITS.
11. REFER TO SHEET AE507 FOR PRECAST DUCT PENETRATION DETAILS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAW ING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAW FORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L
A N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P
A
IN
T F
A C
IL
IT
Y
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
A R
E A
D
DLF
12822612
CJL SRN/NRS
SDS/RSF
N O
R F
O
LK
, V
IR
G
IN
IA
N
A V
A L
S T
A T
IO
N
N O
R F
O
LK
EJA
DJD
DSN
AE114
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - AREA D
AREA
A
AREA
B
AREA
D
AREA C
V-147
3 HANGER ROD SUPPORTED CANOPY. SEE DETAIL A1/AE503 FOR LOCATIONS
IN PRECAST CONCRETE WALL PANEL AND B1/AE503 FOR LOCATIONS IN
CMU WALL.
4 APPROXIMATE OUTLINE OF LARGEST AIRCRAFT IN BAY
5 RIGID RAIL FOR AIRCRAFT HANGAR WITH TROLLEY SYSTEM - REFER TO
STRUCTURAL FOR BEAM INFORMATION
8 LOW ROOF ACCESS - METAL LADDER
9 WALL MOUNTED AIR CONDITIONER UNIT - REFER TO MECHANICAL
10 UNIT HEATER - REFER TO MECHANICAL
12 METAL SOFFIT PANELS
13 INTAKE LOUVER PENTHOUSE - REFER TO MECHANICAL
16 MTL PLATE CLOSURE BY SLIDING HANGAR DOOR MFR
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENER…