1614720dwg14of16_Electrical.pdf
PDF 10 MB Posted
- Solicitation number
- N4008521R2507
About this file
This document provides details on a federal solicitation notice for an indefinite-delivery, indefinite-quantity multiple award construction contract for facilities in the Hampton Roads Area of Responsibility in Virginia. The solicitation was issued by the Naval Facilities Engineering Command seeking design-build and design-bid-build construction services on an as-needed basis. Offerors will be eligible to compete for both small and large projects, including new construction, repairs, and renovations of buildings and structures. The multiple award contracts have no defined limits and will be in effect for five years if all options are exercised. This represents an opportunity for construction firms to assist the Navy in meeting facilities requirements for military installations in the Hampton Roads region of the state.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LED LIGHTING FIXTURE ( INDICATES BRACKET, WALL MOUNTED
FIXTURES). ( INDICATES DIRECTION THROW OF LIGHTING FIXTURE.)
"ST" INDICATES A FIXTURE ON OPTIONAL STANDBY POWER.
EXIT LIGHTING FIXTURE. ARROW, WHEN USED, INDICATES DIRECTION.
( INDICATES BRACKET, WALL MOUNTED FIXTURES). FILLED IN QUADRANT(s)
OF SYMBOL INDICATES NUMBER AND ORIENTATION OF ILLUMINATED FACES.
(SEE LEGEND NOTE 4)
DUPLEX CONVENIENCE RECEPTACLE, 20 A, 125 VAC, MOUNT +
18" AFF UON. SUBSCRIPTS INDICATED BELOW, WHEN USED,
INDICATES THE FOLLOWING:
GFI = INTERNAL GROUND FAULT PROTECTION TYPE
WP = WEATHERPROOF TYPE IN WEATHERPROOF
WHILE-IN-USE ENCLOSURE
WR = WEATHER-RESISTANT TYPE
C = CONTROLLED PLUG LOAD TYPE. SEE CONTROL
DIAGRAM ON SHEET EL602.
DESCRIPTIONSYMBOL
LIGHTINGPROVIDE
POWER DEVICES
SPECIAL PURPOSE RECEPTACLE. NEMA CONFIGURATION, RATING
AND MOUNTING HEIGHT AS INDICATED.
DESCRIPTIONSYMBOL
QUADRUPLEX CONVENIENCE RECEPTACLE MOUNTED IN TWO-GANG
OUTLET BOX - EACH RATED 20A, 125 VOLTS WITH SINGLE COVER
PLATE, MOUNT 18" AFF, UON. "C" INDICATES CONTROLLED PLUG
LOAD TYPE. SEE CONTROL DIAGRAM ON SHEET EL602.
SINGLE OUTLET - 20A, 125 VAC, NEMA 5-20.
LIGHTING FIXTURE TYPE, SEE LIGHTING FIXTURE SCHEDULE
ON SHEET EL601.
LED EMERGENCY LIGHTING FIXTURE ( INDICATES BRACKET,
WALL MOUNTED FIXTURES) CONNECTED TO INVERTER UON. (SEE
LEGEND NOTE 4.)
EMERGENCY BATTERY POWERED LIGHTING UNIT. SEE LEGEND NOTE 4.
PROVIDEEXISTING EXISTING
DLZ
DAYLIGHTING ZONE, FIXTURES WITHIN THIS ZONE ARE CONTROLLED
BY DAYLIGHT SENSOR.
EXTERIOR RATED LIGHTING CONTACTOR. SEE EXTERIOR
LIGHTING CONTACTOR WIRING DIAGRAM ON SHEET EL602.
C
LIGHTING INVERTER. SEE SPECIFICATION 265100 2.6.5.
INV-1 IS 2100VA.
INV-2 IS 400VA.
INV
D LOW VOLTAGE DIMMING SWITCH. 0-10V DIMMING. MOUNT 48" AFF UON.
DH
LOW VOLTAGE DIMMING SWITCH. 0-10V DIMMING. RATED FOR
HAZARDOUS LOCATIONS. CLASS AND DIVISION NOTED ON PLANS.
MOUNT 48" AFF UON.
A
EQUIPMENT CONNECTIONS
EQUIPMENT CONNECTION AS NOTED. SEE LEGEND NOTE 6.
JUNCTION BOX. SEE LEGEND NOTE 6.
MOTOR RATED SWITCH. SEE LEGEND NOTE 6.
DISCONNECT SWITCH, 600 VOLT IN NEMA ENCLOSURE, UON.
3P = INDICATES NUMBER OF POLES
60 = SWITCH RATING
* = INDICATES TO PROVIDE RATED FUSES IN ACCORDANCE
WITH MANUFACTURER'S NAMEPLATE DATA ON
EQUIPMENT BEING PROVIDED.
4 = INDICATES NEMA ENCLOSURE RATING TYPE OTHER
THAN NEMA 1.
E
J
M
MOTOR CONTROLLER OR CONTACTOR PROVIDED WITH
EQUIPMENT
M
MOTOR CONNECTION AS NOTED. SUBSCRIPT SHOWN
INDICATES HORSEPOWER RATING. SEE LEGEND NOTE 6.
3P
PANELBOARD - 208Y/120V
LIGHTNING PROTECTION (SEE LEGEND NOTE 7)
LIGHTNING PROTECTION SYSTEM AIR TERMINAL. SEE "AIR
TERMINAL DETAIL "A" ON SHEET ELP501.
A
LIGHTNING PROTECTION SYSTEM ROOF CONDUCTOR.
LIGHTNING PROTECTION SYSTEM DOWN CONDUCTOR.
R
D
DRIVEN GROUND ROD - 3/4" DIA X 10' LONG.
DRIVEN GROUND ROD WITH INSPECTION PIT. SEE "GROUND
ROD INSPECTION DETAIL" ON SHEET ELP502.
34.5 UNDERGROUND ELECTRIC AS DESCRIBED ON PLANS. NUMBER
TEXT, WHEN SHOWN, INDICATES VOLTAGE.
UC UNDERGROUND COMMUNICATIONS.
SITE LUMINAIRE, FIXTURE TYPE AS INDICATED.
SITE
LIGHTNING PROTECTION SYSTEM DIRECT BURIED GROUND
RING CONDUCTOR.
G
UGE UNDERGROUND LIGHTING - DIRECT BURIED.
UP
UC
MANHOLE OR HANDHOLE - AS DESCRIBED. SUBSCRIPT, WHEN
SHOWN, INDICATES TYPE AND UNIQUE DESIGNATOR FOR
REFERENCE ONLY TO THIS PROJECT.
MH-1 = MANHOLE, TYPE 2 - SEE DETAIL "UG-1" ON SHEET EP502.
HH-1 = HANDHOLE, TYPE 1 - SEE DETAIL "UG-4" ON SHEET EP502.
MH-1
TRANSFORMER - AS INDICATED.T
PANELBOARD - 480Y/277V
RISER AND ONE-LINE
TRANSFORMER - AS DESCRIBED.
EARTH GROUND
MOLDED CASE CIRCUIT BREAKER
SWITCH - AS DESCRIBED
K KIRK-KEY INTERLOCK
MEDIUM VOLTAGE CABLE TERMINATION.
CABLE OR BUS, TYPE AND CHARACTERISTICS AS
INDICATED.
PT
POTENTIAL TRANSFORMER
LINE VOLTAGE PUSH BUTTON SWITCH. MOUNT 48" AFF UON.
3 3-WAY LINE VOLTAGE PUSH BUTTON SWITCH. MOUNT 48" AFF UON.
H LINE VOLTAGE SWITCH. RATED FOR HAZARDOUS LOCATIONS.
CLASS AND DIVISION NOTED ON PLANS. MOUNT 48" AFF UON.
LIGHTING CONTROL SCHEDULE SYMBOL. SEE DESCRIPTION OF
OPERATION SHEET EL602.
VS VACANCY SENSOR. MOUNT 48" AFF UON.
11.5
G GROUNDING CONDUCTOR - DIRECT BURIED.
PAD MOUNTED SF6 SWITCH - 38KV CLASS. SEE POWER RISER
DIAGRAM FOR DESCRIPTION AND SHEET EP501 FOR PAD DETAIL.
PAD MOUNTED TRANSFORMER. SEE POWER RISER DIAGRAM FOR
DESCRIPTION AND SHEET EP501 FOR PAD DETAIL.
INDICATES FRONT OF TRANSFORMER.
3R OR 4
P EXTERIOR RATED PHOTOCELL. MOUNT ON ROOF ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS.
GENERAL
NOTE REFERENCE - TYPICALLY LOCATED ON SAME SHEET
WHERE SYMBOL IS USED.
POINT OF CONNECTION NEW-TO-EXISTING (SEE LEGEND
NOTE 3).
POINT OF DEMOLITION. SEE DEMOLITION NOTES THIS
SHEET.
ROOM NUMBER.
CROSS HATCHING INDICATES REMOVE INDICATED DEVICE OR
CIRCUIT. (SEE LEGEND NOTE 3 AND DEMOLITION NOTES THIS
SHEET)
S
#1/0
INDICATES DUCTBANK SECTION DESIGNATION"A"
HATCHING INDICATES DUCTS WITH CONDUCTORS.
"S" INDICATES SPARE DUCT
HEAVY LINE INDICATES BOTTOM OF DUCT
TYPICAL DUCTBANK SECTION DETAIL. SEE SHEET EP503.
INDICATES TYPE OF CONDUCTORS IN DUCT. SEE SHEET
EP702 FOR SCHEDULE.
#1/0 CONDUCTOR TAG. SEE SHEET EP702 FOR SCHEDULE.
SYMBOL
PROVIDEEXISTING
DESCRIPTION
DISTRIBUTION
WIRE, CONDUIT AND RACEWAY (SEE LEGEND NOTE 1)
BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT RUN
CONCEALED IN CEILING, WALL, FLOOR OR ABOVE SUSPENDED
CEILING. DEFAULT WIRING IS 2#12, 1#12 GND IN 3/4"CONDUIT.
CONDUIT LARGER THAN 3/4"AND WIRE LARGER THAN #12
SHALL BE INDICATED.
HOMERUNS TO PANEL. PANEL AND CIRCUIT DESIGNATIONS AS
INDICATED. PROVIDE 1-POLE OR 3-POLE CIRCUIT BREAKER
CONNECTION AS INDICATED IN PANEL SCHEDULES.
L2-3
OS
PS
DAYLIGHT SENSOR. CEILING MOUNTED. INSTALL ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS.
OCCUPANCY SENSOR. CEILING MOUNTED.
3H 3-WAY LINE VOLTAGE SWITCH. RATED FOR HAZARDOUS LOCATIONS.
CLASS AND DIVISION NOTED ON PLANS. MOUNT 48" AFF UON.
UNDERGROUND ELECTRIC - DEMOLISHUP X XX X
UNDERGROUND TELECOMMUNICATIONS - DEMOLISHUC X XX X
WP LINE VOLTAGE. WEATHER-PROOF. MOUNT 48" AFF UON.
4 4-WAY LINE VOLTAGE PUSH BUTTON SWITCH. MOUNT 48" AFF UON.
CIRCUIT LENGTH LIMITS
BRANCH CIRCUIT MAXIMUM VOLTAGE DROP SHALL NOT EXCEED 3 PERCENT. WHERE
CIRCUIT HOMERUNS EXCEED THE LENGTH INDICATED BELOW, UTILIZE THE NEXT
LARGER CONDUCTOR SIZE FOR THAT CIRCUIT HOMERUN. WHERE THE CONDUCTOR
SIZE IS INCREASED, CORRDINATE CONDUIT SIZE WITH NEC CHAPTER 9 FILL CHARTS
AND INCREASE AS NECESSARY FOR CONDUCTORS CONTAINED THEREIN. INCREASE
THE GROUND CONDUCTOR SIZE PROPORTIONALLY WHERE THE PHASE CONDUCTOR
SIZE IS INCREASED.
WIRE (AWG)
120V (LF)
208V, 1PH (LF)
277V (LF)
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P A
IN
T
F A
C
IL
IT
Y
E
LE
C T
R
IC
A L
LE
G
E N
D
G E
N E
R A
L N
O
TE
S
JLC
12822745
RTK MSW
SDS/RSF
N O
R
FO
LK
, V
IR
G
IN
IA
N A
V A
L S
TA
T
IO
N
N O
R
FO
LK
EJA
NBJ
DSN
E-001
LEGEND NOTES
GENERAL NOTES
A. WIRING SHALL BE IN CONDUIT, MINIMUM SIZE ONE-HALF (1/2) INCH WITH
LARGER SIZES AS INDICATED OR REQUIRED BY NEC.
B. WIRE AND CABLE SHALL BE #12 AWG MINIMUM.
C. OPENINGS CREATED IN A FIRE OR SMOKE RATED WALL OR FLOOR BY
PROVISION OF ANY ELECTRICAL DEVICE OR CONDUIT, SHALL BE SEALED
AFTER THE WORK IS COMPLETED WITH A UL APPROVED FIRE/SMOKE
SEALANT APPROPRIATE TO RE-ESTABLISH THE PREVIOUS RATING OF
THE WALL OR FLOOR. SEE ARCHITECTURAL PLANS FOR FIRE RATED
WALLS/FLOORS AND THEIR RATING.
D. COORDINATE EXACT LOCATION OF CEILING MOUNTED LIGHTING
FIXTURES AND SPEAKERS WITH ARCHITECTURAL REFLECTED CEILING
PLANS.
E. MC TYPE CONDUIT IS PERMITTED FOR BRANCH CIRCUIT WIRING ONLY IN
THE FOLLOWING DRY LOCATIONS; CONCEALED IN WALL OR ATTIC
SPACES.
F. SURFACE MOUNT CONDUIT AND DEVICES IN UNFINISHED SPACES.
G. COORDINATE EXACT LOCATION OF LIGHTING FIXTURES AND DEVICES
WITH MECHANICAL, FIRE PROTECTION, AND PLUMBING, ETC.
H. FOR PHOTOCELL AND DAY LIGHTING FC LEVEL CONTROL SETTING
REFER TO SPECIFICATION SECTIONS 26-51-00 AND 26-56-00.
I. CONDUIT HOMERUNS SHALL BE ROUTED PARALLEL ALONG PERIMETER
WALLS. DO NOT ROUTE HOMERUNS SUSPENDED HORIZONTALLY WITHIN
OPEN SPACES.
1. WIRE AND CONDUIT FOR MOTOR AND EQUIPMENT LOADS SHALL BE
CONTINUOUS IN SIZE AND COUNT FROM SOURCE TO FINAL CONNECTION.
SIZE AND COUNT SHALL BE AS INDICATED ON THE CIRCUIT HOMERUN
UNLESS OTHERWISE NOTED.
2. WHERE BRANCH CIRCUIT HOMERUNS ARE LABELED "SPLIT CIRCUIT" (SC),
THE BRANCH CIRCUIT NUMBER INDICATED HAS BEEN USED ON MORE
THAN ONE HOMERUN INDICATOR. INSTALL ONLY ONE CONDUCTOR PER
CIRCUIT BREAKER POLE WITHIN THE PANELBOARD ENCLOSURE.
SPLICES NECESSARY TO COMPLY WITH THIS REQUIREMENT SHALL BE
MADE IN A SEPARATE SPLICE BOX OUTSIDE THE PANELBOARD
ENCLOSURE.
3. WHERE A NEW-TO-EXISTING CONNECTION IS INDICATED, PROVIDE
MATERIALS AND LABOR REQUIRED TO MAKE THE CONNECTION.
4. BRANCH CIRCUIT WIRING TO EXIT LIGHT FIXTURES AND TO THE BATTERY
INVERTERS WITHIN FIXTURES WITH INTEGRAL BATTERY UNITS SHALL BE
UNSWITCHED, CONNECTED AHEAD OF ANY CONTROL SWITCHES.
5. SUBSCRIPT, WHEN SHOWN, INDICATES SWITCH TO FIXTURE CONTROL
RELATIONSHIP.
6. WHEN SHOWN AS EQUIPMENT CONNECTION, SEE "EQUIPMENT
CONNECTION SCHEDULE" FOR DESCRIPTION.
7. SEE SHEETS ELP501 AND ELP502 FOR ADDITIONAL TYPICAL LIGHTNING
PROTECTION DETAILS.
DEMOLITION NOTES
A. WHERE EXISTING EQUIPMENT IS INDICATED FOR REMOVAL, ALL
ASSOCIATED CONDUIT AND WIRING SHALL BE REMOVED BACK TO THE
NEAREST REMAINING ACTIVE OUTLET OR DEVICE. WHERE CONDUIT IS
RUN CONCEALED, THE CONDUCTORS SHALL BE REMOVED AND THE
CONDUIT MAY BE ABANDONED IN PLACE.
B. WHERE DEMOLITION WORK FOR BUILDING SERVICE(S) IS SHOWN, ALL
WORK RELATED TO SERVICE INTERUPTIONS/OUTAGES SHALL BE
COORDINATE IN ADVANCE WITH EACH OF THE BASE FACILITIES
RESPECTIVE SERVICE(S). PROVIDE IN ADVANCE, DETAILED AND
SCHEDULED TIME FRAME OF WORK FOR SERVICE INTERUPTION(S) FROM
START TO COMPLETION OF THE WORK INTENDED AND MUST BE
SUBMITTED IN WRITING A MINIMUM OF 3 WEEKS IN ADVANCE. APPROVAL
FROM BASE FACILITIES MUST BE OBTAINED PRIOR TO START OF
DEMOLITION WORK.
ELECTRICAL ABBREVIATIONS
ELECTRICAL LEGEND
A A/C
AF
AFF
AFG
AHU
AT
AWG
BG
BLDG
BRKR
C OR COND
CB
CCT
DES
DF
DISC SW
DLZ
DT
DWG
EA
EC
EF
EGC
ELEC
EMT
EQUIP
ETR
EWC
EXIST
EXP
FACP
FC
FCU
FLA
FT
GFI
G OR GND
GRS
HH
HID
HP
IC
KAIC
KCMIL
KVA
KWH
L
LED
AMPERE
AIR CONDITIONING
AMPERE FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE TRIP
AMERICAN WIRE GAUGE
BELOW GRADE
BUILDING
BREAKER
CONDUIT
CIRCUIT BREAKER
CIRCUIT
DESIGNATION
DEMAND FACTOR
DISCONNECT SWITCH
DAY LIGHTING ZONE
DRY TYPE
DRAWING
EACH
EMPTY CONDUIT
EXHAUST FAN
ELECTRICAL GROUNDING CONDUCTOR
ELECTRICAL
ELECTRICAL METALLIC TUBING
EQUIPMENT
EXISTING TO REMAIN
ELECTRIC WATER COOLER
EXISTING
EXPLOSION PROOF EQUIPMENT
FIRE ALARM CONTROL PANEL
FOOTCANDLE
FAN COIL UNIT
FULL LOAD AMPS
FEET
GROUND FAULT INTERRUPTER
GROUND
GALVANIZED RIGID STEEL
HANDHOLE
HIGH INTENSITY DISCHARGE
HORSEPOWER
INSULATION CONTACT
THOUSAND AMP CAPACITY, RMS SYMMETRICAL
THOUSAND CIRCULAR MILS
KILOVOLT AMPERE
KILOWATT HOUR
LINE
LIGHT EMITTING DIODE
LTG
MCB
MH
MLO
MT
MTD
MTG HT
N OR NEU
N/C N/O
NCTAMS
NEC
NESC
NF
NIC
NL
NTS
OC
P
PH
PNL
PVC
QTY
RECEPT
REQ'D
RM
S/N
SC
SE
SF
SPD
SW
TTB
TV
TYP
UG
UH
UON
UP
V
VDC
W
WH
WP
XFMR
Ø
LIGHTING
MAIN CIRCUIT BREAKER
MANHOLE
MAIN LUG ONLY
MOUNT
MOUNTED
MOUNTING HEIGHT
NEUTRAL
NORMALLY CLOSED
NORMALLY OPEN
NAVAL COMPUTER AND TELECOMMUNICATIONS
AREA MASTER STATION
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL SAFETY CODE
NON FUSIBLE
NOT IN CONTRACT
NIGHT LIGHT
NOT TO SCALE
OCCUPANCY SENSOR
POLE
PHASE
PANEL
POLYVINYL CHLORIDE CONDUIT
QUANTITY
RECEPTACLE
REQUIRED
ROOM
SOLID NEUTRAL
SPLIT CIRCUIT (SEE LEGEND NOTE 2)
SERVICE ENTRANCE
SUPPLY FAN
SURGE PROTECTIVE DEVICE
SWITCH
TELEPHONE TERMINAL
TELEVISION
TYPICAL
UNDERGROUND
UNIT HEATER
UNLESS OTHERWISE NOTED
UNDERGROUND POWER
VOLTAGE OR VOLTS
VOLTS DIRECT CURRENT
WIRE
WATER HEATER
WEATHERPROOF
TRANSFORMER
PHASE
BID OPTIONS
1. APRON SHOW MELTING SYSTEMS FOR PMB, PAINT BAY AND WASH
RACK HANGAR DOORS (NOT SHOWN ON PLANS): SEE
SPECIFICATION SECTION 22 13.00 20.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
GRAPHIC SCALE(S)
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 07 AUG 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
UNCLASSIFIED
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
NO
RF
OL
K, V
A
NA
VA
L
ST
AT
IO
N
NO
RF
O
LK
NO
RF
O
LK
, V
IR
G
IN
IA
P-
C
O
RR
O
SI
O N
CO
NT
RO
L
PA
IN
T
FA
CI
LI
TY
1614720
N40085-19-D-9041
757.455.5800 FAX 757.455.5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SUITE 1400
VIRGINIA BEACH, VA 23462
SDS/RSF
DSN
CO
MM
ON
WEA
LTH OF VIRGINIA
PROFESSIONAL EN
GI
NE
ER
SCOTT PARKER SCHWERIN
Lic. No. 37431
14 Sept 2020
EJA
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
ESD101
GENERAL NOTES
1. EXISTING UNDERGROUND 4" COMMUNICATION DUCT WITH 100 PAIR
COPPER CABLE - REMOVE.
2. EXISTING UNDERGROUND MEDIUM VOLTAGE CONCRETE ENCASED DUCT
WITH ABANDONED CONDUCTORS - REMOVE.
DEMOLITION NOTES
MATCH LINE - SEE SHEET ESD102
DEMOLITION PLAN
SCALE: 1" = 30'
1. SEE "GENERAL COMMUNICATIONS DEMOLITION NOTES" ON SHEET T-001
FOR PHASING NOTES PRIOR TO START OF COMMUNICATIONS RELATED
DEMOLITION.
2. NAVAL COMPUTER AND TELECOMMUNICATIONS AREA MASTER STATION
(NCTAMS) CONTACT IS RAMON MARTINEZ, P.E. WITH NAVFAC MIDLANT
UTILITY AND ENERGY MANAGEMENT (UEM) BUILDING P-65, ROOM 112A.
PHONE 757-341-1174.
CO
BM
FO
FO G
G G
G G
G G
G G
G G
G G
G G
G G
G G
G
G G
G G
G G
G G
G G
G G
G G
G G
G G
GG
D
D
D
D
D
CB
CB
CB
CB
D
D
D D
CB
CB
CB
CB
CB
CB
CB
CB
FO
CO
EM
EXISTING-TO-REMAIN COMMUNICATION
MANHOLE MH-U14
EXISTING ELECTRIC
MANHOLE - REMOVE
TH
IR
D
AV
E
BELLINGER BLVD
EXISTING-TO-REMAIN ELECTRIC MANHOLE
EXISTING COMMUNICATION
MANHOLE V52 - REMOVE
AutoCAD SHX Text
ELECTRICAL SITE - DEMOLITION
AutoCAD SHX Text
RTK
AutoCAD SHX Text
MSW
AutoCAD SHX Text
SPS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text 12822746
AutoCAD SHX Text 60'
AutoCAD SHX Text 0'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 30'
AutoCAD SHX Text N
AutoCAD SHX Text
EM
AutoCAD SHX Text
6"CC
AutoCAD SHX Text
L/P POST (ADBND.)
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
ASPHALT PARKING LOT
AutoCAD SHX Text
ASPHALT PARKING LOT
AutoCAD SHX Text
ASPHALT PARKING LOT
AutoCAD SHX Text
6"CC
AutoCAD SHX Text
6"CC
AutoCAD SHX Text
FO
AutoCAD SHX Text
FO
AutoCAD SHX Text
CONC. PARKING LOT
AutoCAD SHX Text
GV
AutoCAD SHX Text
RIPRAP
AutoCAD SHX Text W
AutoCAD SHX Text W
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 07 AUG 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
UNCLASSIFIED
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
NO
RF
OL
K, V
A
NA
VA
L
ST
AT
IO
N
NO
RF
O
LK
NO
RF
O
LK
, V
IR
G
IN
IA
P-
C
O
RR
O
SI
O N
CO
NT
RO
L
PA
IN
T
FA
CI
757.455.5800 FAX 757.455.5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SUITE 1400
VIRGINIA BEACH, VA 23462
SDS/RSF
DSN
CO
MM
ON
WEA
LTH OF VIRGINIA
PROFESSIONAL EN
GI
NE
ER
SCOTT PARKER SCHWERIN
Lic. No. 37431
14 Sept 2020
EJA
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
ESD102
GENERAL NOTES
1. EXISTING UNDERGROUND 4" COMMUNICATIONS DUCT WITH 100 PAIR
COPPER CABLE - REMOVE
2. EXISTING UNDERGROUND MEDIUM VOLTAGE CONCRETE ENCASED DUCT
WITH ABANDONED CONDUCTORS - REMOVE
3. EXISTING TO REMAIN - 11.5kV MEDIUM VOLTAGE FEED FOR EXISTING
BUILDING V-64. TERMINATE AND OR SPLICE CONDUCTORS AS REQUIRED
TO MAINTAIN MEDIUM VOLTAGE FEED TO EXISTING BUILDING V-64.
DEMOLITION NOTES
DEMOLITION PLAN
SCALE: 1" = 30'
MATCH LINE - SEE SHEET ESD101
1. SEE "GENERAL COMMUNICATIONS DEMOLITION NOTES" ON SHEET T-001
FOR PHASING NOTES PRIOR TO START OF COMMUNICATIONS RELATED
DEMOLITION.
2. NAVAL COMPUTER AND TELECOMMUNICATIONS AREA MASTER STATION
(NCTAMS) CONTACT IS RAMON MARTINEZ, P.E. WITH NAVFAC MIDLANT
UTILITY AND ENERGY MANAGEMENT (UEM) BUILDING P-65, ROOM 112A.
PHONE 757-341-1174.
AC
MW
T
CB
CB
CB
AC
EM
EM
EM
EM
EM CO
EXISTING
BUILDING V-64
EXISTING-TO-REMAIN
COMMUNICATIONS MANHOLE V51A.
EXISTING-TO-REMAIN
ELECTRIC MANHOLE.
AutoCAD SHX Text
ELECTRICAL SITE - DEMOLITION
AutoCAD SHX Text
RTK
AutoCAD SHX Text
MSW
AutoCAD SHX Text
SPS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text 12822747
AutoCAD SHX Text 60'
AutoCAD SHX Text 0'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 30'
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
PIV
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
ASPHALT PARKING LOT
AutoCAD SHX Text
ASPHALT PARKING LOT
AutoCAD SHX Text
WVAULT
AutoCAD SHX Text
WMH
N
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 07 AUG 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
UNCLASSIFIED
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
NO
RF
OL
K, V
A
NA
VA
L
ST
AT
IO
N
NO
RF
O
LK
NO
RF
O
LK
, V
IR
G
IN
IA
P-
C
O
RR
O
SI
O N
CO
NT
RO
L
PA
IN
T
FA
CI
757.455.5800 FAX 757.455.5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SUITE 1400
VIRGINIA BEACH, VA 23462
SDS/RSF
DSN
CO
MM
ON
WEA
LTH OF VIRGINIA
PROFESSIONAL EN
GI
NE
ER
SCOTT PARKER SCHWERIN
Lic. No. 37431
14 Sept 2020
EJA
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
ES101
GENERAL NOTES
1. PAD MOUNT GENERATOR.
2. SF6 PAD MOUNT SWITCHGEAR. SEE SHEET EP501 FOR PAD DETAIL.
3. SEE "POWER RISER DIAGRAM" ON SHEET EP701 FOR ADDITIONAL
INFORMATION.
4. EXISTING COMMUNICATIONS MANHOLE "U14". SEE "GENERAL
COMMUNICATIONS DEMOLITION NOTES" ON SHEET T-001 FOR NEW COPPER
REQUIREMENTS.
5. 3-WAY CONCRETE ENCASED DUCTBANK WITH 4" DUCTS. (1) 4" DUCT WITH 25
PAIR, OSP COPPER CONDUCTOR AND (1) 4" DUCT WITH (1) 12 STRAND, OSP
FIBER CONDUCTOR. OTHER 4" DUCT IS FOR FUTURE SPARE.
6. PROVIDE (3) #750KCMIL MEDIUM VOLTAGE CONDUCTORS AND (1) #4/0 CU
600V INSULATED GROUND IN EXISTING AVAILABLE DUCTS.
7. PROVIDE (3) #750KCMIL MEDIUM VOLTAGE CONDUCTORS AND (1) #4/0 CU
600V INSULATED GND IN 3-WAY CONCRETE ENCASED DUCTBANK WITH 6"
DUCTS.
8. STUB UP CONDUITS UP INTO CABLE WELL SECTION OF SF6 PAD MOUNT
SWITCHGEAR.
9. LIGHT POLE, CONDUIT, CONDUCTORS AND ASSOCIATED APPURTENANCES
ARE INCLUDED AS PART OF POLES AND POLE MOUNTED LUMINAIRES AT
PEDESTRIAN SIDEWALK BID OPTION .
10. HANDHOLE FOR LOCAL CABLE SERVICE PROVIDERS CABLING.
11. 2" PVC WITH PULLWIRE. DIRECT BURY 18" BELOW FINISHED GRADE AND STUB
UP INTO MAIN TELECOMMUNICATIONS ROOM. SEE SHEET TT401 FOR
LOCATION.
12. CONNECT TO CIRCUIT HL-10 IN ELECTRICAL ROOM 110. PROVIDE 2#10 1#10 G
IN 1" DIRECT BURIED CONDUIT. CONNECT TO LIGHTING CONTACTOR
OUTSIDE ROOM 110 AND UTILIZE CONTROL OPERATION 8 AS INDICATED IN
LIGHTING CONTROL SCHEDULE ON SHEET EL602.
CONSTRUCTION NOTES#
ELECTRICAL SITE PLAN
SCALE: 1" = 30'
MATCH LINE - SEE SHEET ES102
MATCH LINE - SEE SHEET ES102
1. SEE "GENERAL COMMUNICATIONS DEMOLITION NOTES" ON SHEET T-001 FOR
PHASING NOTES PRIOR TO START OF COMMUNICATIONS RELATED
DEMOLITION.
2. NAVAL COMPUTER AND TELECOMMUNICATIONS AREA MASTER STATION
(NCTAMS) CONTACT IS RAMON MARTINEZ, P.E. WITH NAVFAC MIDLANT
UTILITY AND ENERGY MANAGEMENT (UEM) BUILDING P-65, ROOM 112A.
PHONE 757-341-1174.
H
CO
FO
5 5
BUILDING MAIN TELECOMMUNICATIONS
ROOM 140.
HH3
HH2
HH1
BUILDING MAIN
ELECTRICAL ROOM 110
2 1
Z1
Z1
Z1
Z1
Z1
Z1
Z1
Z1
Z1 Z1
Z1 Z1
Z1 Z1
EXISTING ELECTRIC
MANHOLE MH3455
EXISTING ELECTRIC
MANHOLE MH3423A
NEW ELECTRIC
MANHOLE ,
UG-1 (TYPE 2)
BELLINGER BLVD
TH
IR
D
AV
E
EXISTING
BUILDING
V147
Z1 Z1
ES401
A1
MH
MH1
MH
MH
Z1
MH2
NEW ELECTRIC
MANHOLE, UG-1
(TYPE 2)
"A" 34.5
"A"
34.5
EXISTING
MANHOLE MH-U14
FRONT OF
BUILDING
BUILDING
P-1035
HH4
AutoCAD SHX Text
ELECTRICAL SITE PLAN
AutoCAD SHX Text
RTK
AutoCAD SHX Text
MSW
AutoCAD SHX Text
SPS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text 12822748
AutoCAD SHX Text 60'
AutoCAD SHX Text 0'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 30'
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
EM
AutoCAD SHX Text
6"CC
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
ASPHALT PARKING LOT
AutoCAD SHX Text E
AutoCAD SHX Text
FO
AutoCAD SHX Text
FO
AutoCAD SHX Text
CONC. PARKING LOT
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 07 AUG 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
UNCLASSIFIED
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
NO
RF
OL
K, V
A
NA
VA
L
ST
AT
IO
N
NO
RF
O
LK
NO
RF
O
LK
, V
IR
G
IN
IA
P-
C
O
RR
O
SI
O N
CO
NT
RO
L
PA
IN
T
FA
CI
757.455.5800 FAX 757.455.5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SUITE 1400
VIRGINIA BEACH, VA 23462
SDS/RSF
DSN
CO
MM
ON
WEA
LTH OF VIRGINIA
PROFESSIONAL EN
GI
NE
ER
SCOTT PARKER SCHWERIN
Lic. No. 37431
14 Sept 2020
EJA
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
ES102
GENERAL NOTES
1. NEW CONCRETE ENCASED 4" CONDUIT WITH PF-89, 100 PAIR COPPER
CABLING TO REFEED EXISTING BUILDING V-64.
2. SEE "DEMOLITION NOTES" ON SHEET T-001 FOR TELECOM RELATED
CABLING REQUIREMENTS.
3. EXISTING MEDIUM VOLTAGE SF6 GAS SWITCH "SW-220".
4. SEE "POWER RISER DIAGRAM" ON SHEET EP701 FOR ADDITIONAL
INFORMATION.
5. PROVIDE (3) #750KCMIL MEDIUM - VOLTAGE CONDUCTORS AND (1) #4/0 CU
600V INSULATED GND IN EXISTING AVAILABLE DUCTS.
6. PROVIDE A NEW-T0-EXISTING SPLICE FOR 100 PAIR COPPER CABLE TO
REESTABLISH SERVICE TO EXISTING BUILDING V-64.
7. EXISTING TELECOMMUNICATIONS DUCTBANK WITH PF-80, 100 PAIR
COPPER CABLING BY NAVAL COMPUTER AND TELECOMMUNICATIONS AREA
MASTER STATION (NCTAMS).
CONSTRUCTION NOTES#
MATCH LINE - SEE SHEET ES101
ELECTRICAL SITE PLAN
SCALE: 1" = 30'
MATCH LINE - SEE SHEET ES101
1. SEE "GENERAL COMMUNICATIONS DEMOLITION NOTES" ON SHEET T-001 FOR
PHASING NOTES PRIOR TO START OF COMMUNICATIONS RELATED
DEMOLITION.
2. NAVAL COMPUTER AND TELECOMMUNICATIONS AREA MASTER STATION
(NCTAMS) CONTACT IS RAMON MARTINEZ, P.E. WITH NAVFAC MIDLANT
UTILITY AND ENERGY MANAGEMENT (UEM) BUILDING P-65, ROOM 112A.
PHONE 757-341-1174.
ES
ES
CO
M M
CO
M
M
EXISTING ELECTRIC
MANHOLE
4 5
TH
IR
D
AV
E
MH
AC
MW
CO
M
EXISTING COMMUNICATION
MANHOLE T9
EXISTING COMMUNICATION
MANHOLE T5
EXISTING COMMUNICATION
MANHOLE V33
EXISTING COMMUNICATION
MANHOLE V51A - TO REMAIN
EXISTING
BUILDING
V-64
1 2
TH
IR
D
AV
E
MH
MH
MH V33
MH
MH
V51A
EXISTING POWER
MANHOLE - TO REMAIN
T5
T9
MH
EXISTING POWER MANHOLE -
TO REMAIN
AutoCAD SHX Text
ELECTRICAL SITE PLAN
AutoCAD SHX Text
RTK
AutoCAD SHX Text
MSW
AutoCAD SHX Text
SPS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text 12822749
AutoCAD SHX Text 60'
AutoCAD SHX Text 0'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 30'
AutoCAD SHX Text
SAN
AutoCAD SHX Text
ONLY
AutoCAD SHX Text
ONLY
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
ASPHALT PARKING LOT
AutoCAD SHX Text
ASPHALT PARKING LOT
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 07 AUG 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
UNCLASSIFIED
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
NO
RF
OL
K, V
A
NA
VA
L
ST
AT
IO
N
NO
RF
O
LK
NO
RF
O
LK
, V
IR
G
IN
IA
P-
C
O
RR
O
SI
O N
CO
NT
RO
L
PA
IN
T
FA
CI
757.455.5800 FAX 757.455.5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SUITE 1400
VIRGINIA BEACH, VA 23462
SDS/RSF
DSN
CO
MM
ON
WEA
LTH OF VIRGINIA
PROFESSIONAL EN
GI
NE
ER
SCOTT PARKER SCHWERIN
Lic. No. 37431
14 Sept 2020
EJA
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
ES401
GENERAL NOTES
1. SF6 PAD MOUNT SWITCHGEAR. SEE SHEET EP501 FOR PAD DETAIL.
2. STUB UP CONDUITS UP INTO CABLE WELL SECTION OF SF6 PAD MOUNT
SWITCHGEAR.
3. FRONT OF GENSET.
4. NEMA 4, DOUBLE-GANG JUNCTION BOX FOR 120V CONTROL POWER.
5. CONNECTION FOR GENERATOR BLOCK HEATER.
6. CONNECTION FOR GENERATOR BATTERY CHARGER.
7. NEMA 4, DOUBLE-GANG JUNCTION BOX WITH COVER FOR FUTURE SF6
SWITCH AUTOMATION CONTROLS. SURFACE MOUNT TO REAR OF SWITCH
ENCLOSURE.
8. FRONT OF SF6 SWITCH.
9. 2" CONDUIT FOR BATTERY CHARGER, BLOCK HEATER AND 120V CONTROL
POWER.
10. SEE PAD MOUNTED TRANSFORMER DETAIL ON SHEET EP501 FOR
ADDITIONAL CONDUITS INTO FACILITY.
11. #4/0 BARE GROUNDING COPPER CONDUCTOR. DIRECT BURY MINIMUM 24"
BELOW FINISHED GRADE.
12. TO MAIN SYSTEM GROUNDING BAR LOCATED IN ROOM 110. SEE SHEET
EP401.
13. 1" CONDUIT RUN TO MECHANICAL ROOM 124 FOR METERING. STUB
CONDUITS TO DDC CONTROL PANEL. DIRECT BURY 18" BELOW FINISHED
GRADE.
14. 1" CONDUIT FOR GENERATOR CONTROL WIRING. DIRECT BURY 18" BELOW
FINISHED GRADE.TERMINATE CONDUIT TO GENERATOR ATS PER EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS.
15. NEMA 4, DOUBLE GANG JUNCTION BOX FOR GENERATOR LOW VOLTAGE
CONTROLS.
16. 2#12, 1#12 GND IN 3/4" CONDUIT. DIRECT BURY 18" BELOW FINISHED GRADE.
17. PROVIDE FREE STANDING, RIGID MOUNT 18" ABOVE FINISHED CONCRETE
PAD FOR RECEPTACLE.
CONSTRUCTION NOTES#
1. SEE SHEET EP702 FOR FEEDER DESIGNATION SIZES AND SHEET EP503 FOR
DUCTBANK DETAILS.
2. SEE SHEETS EG701 AND EP701 FOR ELECTRICAL GROUNDING DETAIL AND
POWER RISER DIAGRAM.
PARTIAL ENLARGED SITE PLAN
SCALE: 1" = 5'A1
34.5
PAD MOUNT
TRANSFORMER
"T1"
GENERATOR
GENERATOR
INTAKE END
EL-9
EL-11
EL-13
5 4
MAIN ELECTRICAL ROOM 110
MH2
NEW ELECTRIC MANHOLE
1/0M
1/0M
"B"
1/0M
"B"
3000S
"C"
34.5
"A"
"E"
L1-5
G
G
G G
G G
G
G
G
PAD MOUNT
TRANSFORMER
"T2"
10 10
"D"
"D"
3000S
L1-1616
WP/WR
GFI
G G
G G
G
G
AutoCAD SHX Text
ENLARGED ELECTRICAL SITE PLAN
AutoCAD SHX Text
RTK
AutoCAD SHX Text
MSW
AutoCAD SHX Text
SPS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text 12822750
AutoCAD SHX Text 10'
AutoCAD SHX Text 0'
AutoCAD SHX Text 1"=5'
AutoCAD SHX Text 5'
AutoCAD SHX Text J
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
V S
3 3
DH
DH
DH
DH
OS
OS
OS
OS OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
H3
OS
OS
WP
ELEC.
WOMEN'S
LOCKER
ROOM
(CLEAN)
PMB BAY
(PROCESS)
114B
PMB BAY
PMB BAY
(PROCESS)
114A
COMPRESSOR
ROOM
BLAST
MEDIA
RECOVERY
BLAST
MEDIA
STORAGE
CORR.
S1
E2 E2
E2
E2
X2E1E1
E2
P4
P4
E2
P4
E2
A2
A2
X1
X1
V1
P4
A1
L1 X2
PMB
STORAGE
E1E1 E1 X2L1
D1
D4
D4
AIR DRY
S1 W1
W1
W1
H4 H4
H4 H4H4H4H4
W1
F1
F1
F1
FILTER
STORAGE
PMB BAY
EXHAUST
AIR
PLENUM
CORR.
E2
X1
MATCHLINE
EL102
P2
P2
COMM.
P2
JAN.
LOCKER
ROOM
(DIRTY)
F2
F2
A2
L1
MEN'S
LOCKER
ROOM
(CLEAN)
INV-1
V1 V1V1
H6
H6
H6
H6
Y1
Y1
Y1
Y1
Y1
S1
3 4
X2
HL-6
HL-15
HL-13 (SC)
+11'-0" AFG
+25'-0" AFG
+25'-0" AFG
+25'-0" AFG
+8'-6" AFG
W1
E1
P
HL-12
HL-3
HL-5
HL-13
HL-9
EL401
A1
EL401
A3
HL-11
EL401
B1
+12'-0" AFF (TYP FOR
P4 THIS SPACE)
+15'-0" AFG (TYP
FOR P4 THIS SPACE)
W2 W2
+8'-0" AFF
+8'-0" AFF
W1
HL-6 (SC)
EH-33 (SC)
HL-15
EH-21 (SC)
HL-17
UP TO
PLATFORM
UP TO PLATFORMS
H2
TYP. THIS
SPACE
TYP
TYPTYP
TYP
TYP
TYP
TYP
TYP
X2
TYP
TYP
TYP
TYP
TYP
TYP
TYP
HAZARDOUS LOCATION
LISTED AREA
D3
A1
L1
8'-6" AFF
W2
7'-0" AFF
D3
D1
D1 D1 D1
D1
Y2
Y2 7'-8" A.F.F.
+21'-0" AFF
W2
X1
E1
ST ST
ST
ST
ST ST
ST ST
+8'-6" AFG
C
EH-19 (SC)
EH-19 (SC)
EH-19 (SC)EH-19 (SC)
Y2 Y2
E1
H4H4
+6'-8"
AFG
W1
Y3 Y3
Y3
Y3
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P A
IN
T
F A
C
IL
IT
Y
LI
G
H
TI
N G
P
LA
N
A R
E A
A
JLC
12822751
RTK MSW
SDS/RSF
N O
R
FO
LK
, V
IR
G
IN
IA
N A
V A
L S
TA
T
IO
N
N O
R
FO
LK
EJA
NBJ
DSN
EL101
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
SCALE: 1/8" = 1'-0"
LIGHTING PLAN - AREA A
1 AREA ELECTRICALLY CLASSIFIED AS HAZARDOUS CLASS II, DIVISION 1
PER NEC ARTICLE 500.5 AND GROUP G PER NEC ARTICLE 500.6. PROVIDE
APPROPRIATE LISTED ELECTRICAL DEVICES AND CONDUIT SEALS WITHIN
THIS AREA.
2 CONNECT CIRCUIT TO LIGHTING CONTACTOR LOCATED IN ELECTRICAL
ROOM 110. SEE SHEET EL602 FOR CONTACTOR DIAGRAM.
3 CIRCUIT CONNECTED TO LIGHTING INVERTER LOCATED IN ELECTRICAL
ROOM 110.
4 TWO ROWS OF FIXTURES. MOUNT LOWER ROW OF FIXTURES AT 8'-0" AFF
AND UPPER ROW OF FIXTURES AT 16'-0" AFF.
5 MOUNT PHOTOCELL TO ROOF PER MANUFACTURER'S
RECOMMENDATIONS AND CONNECT TO LIGHTING CONTACTOR LOCATED
IN ELECTRICAL ROOM 110
(THIS SHEET ONLY)
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
DH
H
H
DH
DH
H
DH
D
OS
OS
OS
PS
OS
PS
OS
D
H
MEN'S
LOCKER
ROOM
(CLEAN)
CORR.
BREAK
PAINT BAY
PAINT BAY
EXHAUST
AIR
PLENUM
PAINT BAY
(PROCESS)
120B
PAINT BAY
(PROCESS)
120A
E1 E1 E1 X2 X2
A2A2
A1
E1
E1
E1
D4
D4
H4
H4
W1
W1
MECH
104A
H2
F1
X1
A2
MATCHLINE
EL101
MATCHLINE
EL103
P2
P2
PAINT BAY
STORAGE
120C
ISSUE
AIR LOCK
X2
D3
E1 E1E1
F2
F2
H2
H2 H2
H2 H2
H2 H2
H2
H2
Y1
Y1
Y1
H6
H6
H6
H6
H6
H6
EH-33 (SC)
W1
+35'-0" AFG
+35'-0" AFG
+35'-0" AFG
F1
E1
A1 L1
HL-14
HL-2
AIR LOCK
120E
HL-19 (SC)
H6
H1
EH-31
HL-21
HL-23
H6
EH-33 (SC)
TYP
TYP
X1
TYP
TYP
TYP
TYP
TYP
H6
H6
TYP
TYP
H6 TYP
TYP
TYP
TYP
HAZARDOUS LOCATION
LISTED AREA
U1 TYP. FOR 4
+11'-6" AFF
+14'-0" AFF +14'-0" AFF
+14'-0" AFF
+14'-0" AFF +14'-0" AFF +14'-0" AFF
Y2
Y2
ST
ST
ST
ST ST
ST
HL-25
X2
DLZ
Y2 Y2
EH-23 (SC)
EH-23 (SC)
EH-23 (SC)
EH-23 (SC)
Y3
Y3
Y3
Y3
HL-27
HL-29
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P A
IN
T
F A
C
IL
IT
Y
LI
G
H
TI
N G
P
LA
N
A R
E A
B
JLC
12822752
RTK MSW
SDS/RSF
N O
R
FO
LK
, V
IR
G
IN
IA
N A
V A
L S
TA
T
IO
N
N O
R
FO
LK
EJA
NBJ
DSN
EL102
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
SCALE: 1/8" = 1'-0"
LIGHTING PLAN - AREA B
1 AREA ELECTRICALLY CLASSIFIED AS HAZARDOUS CLASS I, DIVISION 1 PER
NEC ARTICLE 500.5 AND GROUP C PER NEC ARTICLE 500.6. PROVIDE
APPROPRIATE LISTED ELECTRICAL DEVICES AND CONDUIT SEALS WITHIN
THIS AREA.
2 TWO ROWS OF FIXTURES. MOUNT LOWER ROW OF FIXTURES AT 10'-0" AFF
AND UPPER ROW OF FIXTURES AT 20'-0" AFF.
3 CIRCUIT CONNECTED TO LIGHTING INVERTER INV-1 LOCATED IN
ELECTRICAL ROOM 110.
(THIS SHEET ONLY)
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
OS
OS
OS
PS
OS
PS
OS
OS
OS OS OS
VS
V S
V S
H H
3H
3H
OS
OS
OS
3H
W P
ADMIN
TOOL CRIB
MATERIAL
STORAGE
PAINT
STORAGE
EQUIPMENT
CLEANING
PAINT
MIXING
CORR.
STENCIL
ROOM
MECHANICAL
ROOM
CORR.
P4
A2
X1
A2 X1
X1
X1
X2
W2
H4
H4
H4
L1
P4P4
L1
X1
D4 D4
A2
ADMIN
CLOSET
101A
MOTHER'S
ROOM
W1
D4
A2
W1
W1
A2 A2
MATCHLINE
EL102
MATCHLINE
EL104
P3
Y1
Y1
Y1
EH-33 (SC)
EH-33 (SC)
+25'-0" AFF
TYP. THIS
SPACE
H4
D1
HL-1
HL-4
HL-8
HL-13
+7'-0" AFG
+7'-0" AFG
+7'-0" AFG
+7'-0" AFG
+8'-6" AFG
+15'-0" AFF
UP TO
ROOF
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
D1
TYP.
EH-35
HL-14
TYP
TYP
TYP
HAZARDOUS LOCATION
LISTED AREA
ST
ST
ST
+11'-0" AFF THIS
SPACE UON
W2
9'-6" AFF
TYP. THIS
SPACE
FOR WALL
MOUNT
ST
ST
ST
ST
DLZ
HL-7
1 8
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P A
IN
T
F A
C
IL
IT
Y
LI
G
H
TI
N G
P
LA
N
A R
E A
C
JLC
12822753
RTK MSW
SDS/RSF
N O
R
FO
LK
, V
IR
G
IN
IA
N A
V A
L S
TA
T
IO
N
N O
R
FO
LK
EJA
NBJ
DSN
EL103
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
SCALE: 1/8" = 1'-0"
LIGHTING PLAN - AREA C
1 CONNECT CIRCUIT TO LIGHTING CONTACTOR LOCATED IN ELECTRICAL
ROOM 110. SEE SHEET EL602 FOR CONTACTOR DIAGRAM.
2 AREA ELECTRICALLY CLASSIFIED AS HAZARDOUS CLASS I, DIVISION 1 PER
NEC ARTICLE 500.5 AND GROUP C PER NEC ARTICLE 500.6. PROVIDE
APPROPRIATE LISTED ELECTRICAL DEVICES AND CONDUIT SEALS WITHIN
THIS AREA.
3 CIRCUIT CONNECTED TO LIGHTING INVERTER INV-1 LOCATED IN
ELECTRICAL ROOM 110.
(THIS SHEET ONLY)
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
H H
DH
DH
D H
DH
DH
H
D H
V S
V S
VS 3
OS
OS
D
H
DH
D H
DH
H
TOILET
WATER
TREATMENT
SYSTEM
COMM.
WASH
RACK
STORAGE
WASH
RACK BAY
W1
X2
X2
W1
E1
W1
X2
E1
E1
H3
E1
E1
H3
E1
X2
H6
D2
V1 L1
V1
D2
H2
D4
H4
H4
CENTRAL
CHEMICAL
STORAGE
SOLVENT
STORAGE
FIRE
PROTECTION
ELEC.
DECONTAMINATION
W1
W1
W1
E1
F1 F1 F1
P4
P4
MATCHLINE
EL103
P3
P1
WASH
RACK
EQUIPMENT
D4
W1
Y1
H4 H4
H4
Y2
Y2
Y2
Y2
E1
E1
X2
H6
H6
H6
F1
EH2-25 (SC)
WASH
RACK
(PROCESS)
JAN.
TOILET
LOCKER
ROOM
(DIRTY)
HL2-9
HL-7
EH2-25 (SC)
EH2-27 (SC)
H4
EH2-27 (SC)
EH2-25 (SC)
EH2-27 (SC)
HL2-11
EH2-27 (SC)
HL2-3
HL2-5
TYP
TYP
EH2-25 (SC)
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
W1
EH-33 (SC)
TYP. FOR 6
TYP
HAZARDOUS LOCATION
LISTED AREA
E1
EH2-25 (SC)
E1
E1
ST
ST
11'-0" AFF
TYP. FOR 8
E1
E1
E1
E1
E1
E1 E1
EH2-25 (SC)
+28'-0" AFF
H5
H5
H5
H5
H5
H5
H5
H4
H4
S
Y2
Y2
+11'-0" AFF
+11'-0" AFF
EH2-27 (SC)
EH2-27 (SC)
INV-2
E1
ST
ST
ST
ST
ST
ST
ST
ST
STST
HL2-1
+8'-6" AFG
+8'-6" AFG
+8'-6" AFG
+8'-6" AFG
+10'-0" AFF
+10'-0" AFF
+10'-0" AFF
+10'-0" AFF
HL-13 2
+12'-0" AFF TYP
THIS SPACE UON
+10'-0" AFF
+10'-0" AFF
HL2-7
+28'-0" AFF
Y3
+32'-6"
AFF
+32'-6"
AFF
+32'-6"
AFF
+32'-6"
AFF
+32'-6"
AFF
+32'-6"
AFF
+31'-0"
AFF
+31'-0"
AFF
+31'-0"
AFF
+31'-0"
AFF
+31'-0"
AFF
+31'-0"
AFF
+33'-6"
AFF
+33'-6"
AFF
Y3
+33'-6"
AFF
+33'-6"
AFF
+31'-0"
AFF
+31'-0"
AFF
+31'-0"
AFF
+31'-0"
AFF
H3 H3
+31'-0"
AFF TYP
E1
E1
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P A
IN
T
F A
C
IL
IT
Y
LI
G
H
TI
N G
P
LA
N
A R
E A
D
JLC
12822754
RTK MSW
SDS/RSF
N O
R
FO
LK
, V
IR
G
IN
IA
N A
V A
L S
TA
T
IO
N
N O
R
FO
LK
EJA
NBJ
DSN
EL104
1/8" = 1' - 0"
0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
AREA
A
AREA
B
AREA
D
AREA C
V-147
SCALE: 1/8" = 1'-0"
LIGHTING PLAN - AREA D
1 AREA ELECTRICALLY CLASSIFIED AS HAZARDOUS CLASS I, DIVISION 1
PER NEC ARTICLE 500.5 AND GROUP C PER NEC ARTICLE 500.6. PROVIDE
APPROPRIATE LISTED ELECTRICAL DEVICES AND CONDUIT SEALS
WITHIN THIS AREA. PROVIDE CONDUIT APPROVED FOR WET LOCATION
APPLICATION WITHIN THIS AREA.
2 CONNECT CIRCUIT TO LIGHTING CONTACTOR LOCATED IN ELECTRICAL
ROOM 110. SEE SHEET EL602 FOR CONTACTOR DIAGRAM.
3 CIRCUIT CONNECTED TO LIGHTING INVERTER INV-2 LOCATED IN
ELECTRICAL ROOM 145.
(THIS SHEET ONLY)
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
F
A
MOUNT 7'-0" ABOVE
PLATFORM
MOUNT 7'-0" ABOVE
PLATFORM
W3
HL-6 (SC)
TYP
A
B
MOUNT FIXTURES
11'--6" ABOVE
PLATFORM
HL-6 (SC)
P4 TYP
2 3 4 5
D
E
MECHANICAL
ROOM
+8'-0" ABOVE
FINISHED ROOF
DECK TYPICAL
THIS SPACE
W3
MOUNT 7'-0" ABOVE
PLATFORM OR
TREADS
W1 W1 W1
W1
W1
W1
W3 W3
HL-8
DOWN TO
MECH ROOM
SWITCH FOR
MECHANICAL ROOM
LIGHTS BELOW
A
FIXTURE CONTROLLED BY SWITCH BELOW
FIXTURES MOUNTED 6'-0"
ABOVE PLATFORM. TYPICAL
THIS VIEW.
HL-6 (SC)
W3 TYP
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P A
IN
T
F A
C
IL
IT
Y
E N
LA
R
G E
D L
IG
H
TI
N
G P
LA
N
S
JE
12822755
JE JE
SDS/RSF
N O
R
FO
LK
, V
IR
G
IN
IA
N A
V A
L S
TA
T
IO
N
N O
R
FO
LK
EJA
NBJ
DSN
EL401
1/4" = 1' - 0" 0 5' 10' 15'1'
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
# KEY NOTES
NOT TO SCALE (EL101)A1
ENLARGED LOWER PLATFORM LIGHTING PLAN
NOT TO SCALE (EL101)A3
ENLARGED PLATFORM LIGHTING PLAN
SCALE: 1/8" = 1'-0"C1 FLOOR PLAN - AREA C - ROOF EQUIPMENT PLATFORM
NOT TO SCALE (EL101)B1 ENLARGED UPPER PLATFORM LIGHTING PLAN
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
TYPE
DIRECT/INDIRECT LED TROFFER
REVISED: MARCH 2020 NL-1LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, WITH ONE-PIECE LOWER REFLECTOR
HAVING TEXTURED, HIGH REFLECTANCE, WHITE POLYESTER POWDER-COATED FINISH.
SIZE 2FT x 4FT.
2. LIGHT SOURCE - DOWNWARD-FACING LEDS WITH DIFFUSE LENS. 4000K COLOR
TEMPERATURE UON, MAXIMUM BINNING TOLERANCE OF A 4-STEP MACADAM ELLIPSE,
MINIMUM EFFICACY OF 90 LUMENS/WATT, WITH A MINIMUM CRI OF 80. INITIAL
LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE
3. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED IN LUMINAIRE
SCHEDULE.
4. CERTIFICATION - UL 1598, DLC QUALIFIED, IC RATED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS.
5. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
6. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
LED RECESSED DOWNLIGHT
REVISED: MARCH 2020 NL-19LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, OR FORGED ALUMINUM WITH HEAT
SINK. DRIVER MUST BE ACCESSIBLE FROM BOTTOM OF LUMINAIRE. PROVIDE T-BAR
HANGERS FOR INSTALLATION IN ACOUSTICAL TILE CEILINGS OR TABS WHEN MOUNTING
IN HARD CEILINGS.
2. REFLECTOR AND TRIM - SPECIFICATION GRADE, LOW IRRIDESCENT, SPECULAR
ALUMINUM REFLECTOR WITH PAINTED TRIM RING..
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 90 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, WET LOCATION, DLC QUALIFIED, AND ROHS
COMPLIANT. COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - RECESSED IN GYPSUM OR ACOUSTICAL TILE CEILING OR OVERHEAD CANOPY.
7. OPTIONS - WALL-WASH TRIM, IC RATED FOR DIRECT CONTACT WITH INSULATION,
VARIOUS APERTURE DIAMETERS, AND VARIOUS GLASS LENSES.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
A1 A2 TYPE D1 D2 D3
LED RECESSED DOWNLIGHT
REVISED: MARCH 2020 NL-19LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, OR FORGED ALUMINUM WITH HEAT
SINK. DRIVER MUST BE ACCESSIBLE FROM BOTTOM OF LUMINAIRE.
2. REFLECTOR AND TRIM - SPECIFICATION GRADE, LOW IRRIDESCENT, SPECULAR
ALUMINUM REFLECTOR WITH METALLIC TRIM RING..
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 90 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, WET LOCATION, DLC QUALIFIED, AND ROHS
COMPLIANT. COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - RECESSED IN OVERHEAD CANOPY.
7. OPTIONS - IC RATED FOR DIRECT CONTACT WITH INSULATION.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
TYPE D4
1.
2. OPTICAL LENS - PYREX. LED OPTICAL ASSEMBLY - TWO MR16 LED LAMPS
LUMINAIRE REQUIREMENTS:
HOUSING - HEAVY GAUGE, CORROSION RESISTANT, COPPER-FREE CAST ALUMINUM WITH
GASKETED COVERS AND HEAVY CAST ALUMINUM LIGHTING HEAD FIXTURES.
3.
4.
5. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER'S PREFERENCE.
EMERGENCY BATTERY UNIT - HAZARDOUS LOCATION
CERTIFICATION - UL AND/OR ETL LISTED FOR WET LOCATIONS AS INDICATED, AND RoHS COMPLIANT. ELECTRICALLY CLASSIFIED CLASS I, DIVISION I HAZARDOUS LOCATION LISTED.
TYPE E1
1.
LED EMERGENCY BATTERY UNIT
HOUSING - UV STABILIZED THERMOPLASTIC BODY
2. FINISH - FINISHED WITH POLYESTER POWDER COAT. STANDARD FINISH IS WHITE.
LED OPTICAL ASSEMBLY - TWO 5.4W ADJUSTABLE HIGH OUTPUT LIGHT HEADS. 550 LUMENS PER
HEAD.
LUMINAIRE REQUIREMENTS:
3.
4.
OTHER - THE ABOVE SKETCH IS A NON-PROPRIETY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER'S PREFERENCE.
TYPE E2
LED FLOODLIGHT
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM WITH LENS FRAME. HOUSING AND OPTICAL UNIT ARE SEALED
WITH HIGH TEMPERATURE SILICON GASKET. ALL MOUNTING HARDWARE IS STAINLESS STEEL.
2. FINISH - FINISHED WITH POLYESTER POWDER COAT. STANDARD FINISH IS BRONZE.
3. LED DRIVER - CLASS 1, CONSTANT CURRENT 120-277V WITH BUILT-IN SURGE PROTECTION.
OPERATING FREQUENCY OF 50/60 HZ, POWER FACTOR GREATER THAN 0.9, AND THD LESS THAN
20% AT FULL LOAD. MINIMUM EFFICACY SHALL BE 60 LUMENS/W.
4. LED OPTICAL ASSEMBLY - CLEAR TEMPERED OPTICAL GRADE FLAT GLASS LENS SEALED TO THE OPTICAL HOUSING FOR IP67 RATING PROVIDED FOR MULTIPLE HIGH-POWERED LEDS WITH HIGH EFFICIENCY REFLECTORS PRODUCING WIDETHROW DISTRIBUTION OR AS OTHERWISE INDICATED.
BUG UPLIGHT RATING OF U0, WITH GLARE RATING AS DETERMINED BY LIGHTING ZONE INSTALLED.
MINIMUM COLOR RENDERING INDEX (CRI) SHALL BE 80 FOR CORRELATED COLOR TEMPERATURE
(CCT) OF 4000 DEGREES K.
5. CERTIFICATION - UL AND/OR ETL LISTED FOR WET LOCATIONS AS INDICATED, AND RoHS
COMPLIANT.
6. OPTIONS - VARIOUS LUMEN OUTPUT RATING AS INDICATED.
7. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER'S PREFERENCE.
LED NOTIFICATION LIGHT
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM WITH LENS FRAME. HOUSING AND OPTICAL UNIT ARE SEALED
WITH HIGH TEMPERATURE SILICON GASKET. ALL MOUNTING HARDWARE IS STAINLESS STEEL OR
ELECTRO - ZINC PLATED STEEL. NEMA TYPE 4X ENCLOSURE. WALL MOUNTED.
3. LED DRIVER - CLASS 1, CONSTANT CURRENT 120-277V WITH BUILT-IN SURGE PROTECTION.
OPERATING FREQUENCY OF 50/60 HZ, POWER FACTOR GREATER THAN 0.9, AND THD LESS THAN
20% AT FULL LOAD. MINIMUM EFFICACY SHALL BE 60 LUMENS/W.
4. LED OPTICAL ASSEMBLY - CLEAR TEMPERED OPTICAL GRADE FLAT GLASS LENS SEALED TO THE OPTICAL HOUSING FOR 1P67 RATING PROVIDED FOR MULTIPLE HIGH-POWERED LEDS WITH HIGH EFFICIENCY REFLECTORS PRODUCING WIDETHROW DISTRIBUTION OR AS OTHERWISE INDICATED.
5. CERTIFICATION - UL AND/OR ETL LISTED FOR WET LOCATIONS AS INDICATED, AND RoHS
COMPLIANT.
6. OPTIONS - RED LENS.
7. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER'S PREFERENCE.
2. FINISH - BLACK BASE.
TYPE F1 TYPE F2
LED EXPLOSION PROOF RECESSED TROFFER
TYPE
LUMINAIRE REQUIREMENTS:
1. HOUSING - COPPER-FREE ALUMINUM SEALED CASE, RESISTANT TO HIGH VIBRATION,
HIGH HUMIDITY, AND HIGH TEMPERATURES.
2.
3. LIGHT SOURCE - LEDS WITH MINIMUM OPERATING LIFESPAN OF 150,000 HOURS, MINIMUM 80 CRI, 4000K CCT; INITIAL LUMEN OUTPUT AS INDICATED ON FIXTURE SCHEDULE.
4. DRIVER - INTEGRATED ELECTRONIC 120-277 V, 50/60 HZ, MINIMUM .9 PF
5. CERTIFICATION - IP67 WATERPROOF, ELECTRICALLY CLASSIFIED I DIV I AND CLASS II DIV I HAZARDOUS
LOCATIONS
LENS - WIDE AREA OPTICAL LENS FOR MAXIMUM AREA DISTRIBUTION
THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
6.
H1
EMERGENCY PACK - SOLID-STATE, CONSTANT-CURRENT TYPE BATTERY
CHARGER WITH MAINTENANCE-FREE, NICKEL-CADMIUM BATTERY, AC-ON
INDICATOR LAMP AND TEST SWITCH. 90 MINUTE REQUIREMENT. UL924 LISTED.
EMERGENCY PACK - SOLID-STATE, CONSTANT-CURRENT TYPE BATTERY
CHARGER WITH MAINTENANCE-FREE, NICKEL-CADMIUM BATTERY, AC-ON
INDICATOR LAMP AND TEST SWITCH. 90 MINUTE REQUIREMENT.
5.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
N40085-19-D-9041
1614720
1 2 3 4 5
Approved by Brett D. Ingle, Captain, USN, Commander, with Fleet Readiness Center
Mid-Atlantic, via Email.
14 Sept 2020
P -1
C
O R
R O
S
IO
N C
O N
T R
O L
P A
IN
T
F A
C
IL
IT
Y
LI
G
H
TI
N G
D E
TA
IL
S
JLC
12822756
RTK MSW
SDS/RSF
N O
R
FO
LK
, V
IR
G
IN
IA
N A
V A
L S
TA
T
IO
N
N O
R
FO
LK
EJA
NBJ
DSN
EL501
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
GASKET SEALED DIRECT LED FLAT PANEL
REVISED: MARCH 2020 NL-9LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, HEAVY GAUGE STEEL, HINGED DOOR WITH INTERIOR GASKET
TRIM. WELDED CONSTRUCTION. OPTIONAL DIE-FORMED ALUMINUM AND STAINLESS
STEEL. SIZES OF 2' X 4' AND 1' X 4'
2. LENS - ACRYLIC PRISMATIC OR WHITE OPAL TO PROVIDE EVEN ILLUMINATION AND TO
ELIMINATE PIXILATION FROM LED LIGHT SOURCE.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 90 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, IP65 RATED, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
TYPE L1
LED EXPLOSION PROOF RECESSED TROFFER
LUMINAIRE REQUIREMENTS:
1. HOUSING - COPPER-FREE ALUMINUM SEALED CASE, RESISTANT TO HIGH VIBRATION,
HIGH HUMIDITY, AND HIGH TEMPERATURES.
2.
3. LIGHT SOURCE - LEDS WITH MINIMUM OPERATING LIFESPAN OF 150,000 HOURS, MINIMUM 80 CRI, 4000K CCT; INITIAL LUMEN OUTPUT AS INDICATED ON FIXTURE SCHEDULE.
4. DRIVER - INTEGRATED ELECTRONIC 120-277 V, 50/60 HZ, MINIMUM .9 PF
5. CERTIFICATION - IP67 WATERPROOF, ELECTRICALLY CLASSIFIED CLASS I DIV I AND CLASS II DIV I
HAZARDOUS LOCATIONS
LENS - WIDE AREA OPTICAL LENS FOR MAXIMUM AREA DISTRIBUTION
THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
6.
TYPE H2
LED EXPLOSION PROOF DOWNLIGHT PENDANT
LUMINAIRE REQUIREMENTS:
1. HOUSING - COPPER-FREE ALUMINUM SEALED CASE, RESISTANT TO HIGH VIBRATION,
HIGH HUMIDITY, AND HIGH TEMPERATURES.
2.
3. LIGHT SOURCE - LEDS WITH MINIMUM OPERATING LIFESPAN OF 150,000 HOURS, MINIMUM 80 CRI, 4000K CCT; INITIAL LUMEN OUTPUT AS INDICATED ON FIXTURE SCHEDULE.
4. DRIVER - INTEGRATED ELECTRONIC 120-277 V, 50/60 HZ, MINIMUM .9 PF
5. CERTIFICATION - IP67 WATERPROOF, ELECTRICALLY CLASSIFIED CLASS I DIV I AND CLASS II DIV I
HAZARDOUS LOCATIONS
LENS - WIDE AREA OPTICAL LENS FOR MAXIMUM AREA DISTRIBUTION
THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
6.
TYPE H3 H5
LED EXPLOSION PROOF STRIP
LUMINAIRE REQUIREMENTS:
1. HOUSING - COPPER FREE ALUMINUM SEALED CASING RESISTANT TO HIGH VIBRATION, HIGH HUMIDITY, AND HIGH TEMPERATURE LOCATIONS
2.
3. DRIVER - 120-277V, 50/60HZ, MINIMUM .9 PF AND MAXIMUM 15% THD. 0 -10V DIMMING CONTROLS DIMMABLE TO 10% OF MAXIMUM LUMEN OUTPUT. INITIAL LUMEN OUTPUT AS INDICATED ON SCHEDULE.
4.
5.
CERTIFICATION - CLASS I, DIV I AND CLASS II, DIV II HAZARDOUS RATING. IP66 SPLASH RATED. MEETS
UL STANDARDS.
FIXTURE LENGTH -
TYPE H4 = 4' VERSION
TYPE H6 = 2' VERSION
LIGHT SOURCE - 4000K CCT, MINIMUM 80 CRI, RATED FOR AT LEAST 150,000 OPERATIONAL HOURS.
INITIAL LUMEN OUTPUT AS INDICATED ON FIXTURE SCHEDULE.
6. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER'S PREFERENCE. ALL DIMENSIONS ARE NOMINAL AND VARY PER
MANUFACTURER.
TYPE H4 H6
LED INDUSTRIAL STRIP
REVISED: MARCH 2020 NL-7LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .