This solicitation is for design-build construction services for the P-381 Multi-Mission Dry Dock #1 project located at Portsmouth Naval Shipyard in Kittery, Maine. The scope of work includes constructing two new dry dock bays labeled DD1N and DD1W of sufficient size and depth to support maintenance and overhaul of Virginia Class submarines. Additional requirements are concrete floors, walls and a center wall separating the bays; new pump well systems and a pump station building; portal crane rails; mooring hardware; mechanical and electrical utilities; utility tunnels; and all other appurtenances to ensure operational dry docks. Modifications will also be made to the existing dry dock basin closure wall, Berths 1 and 11 to prevent undermining and allow fully dewatered conditions. The existing DD1 pump well will be connected to the new system and interior modified. The solicitation is issued by the Department of the Navy Naval Facilities Engineering Command.

View the file

Other files

File Type Posted
AMENDMENT 0015.pdf PDF
Amendment 14 - 25 00 00.00 22.pdf PDF
Amendment 14 - Electrical dwgs.pdf PDF
AMENDMENT 0014.pdf PDF
Amendment 14 - Mechanical Dwgs.pdf PDF
Amendment 14 - Electrical One Line.pdf PDF
Amendment 14 - Fire Protection One Line.pdf PDF
Amendment 14 - Henderson Point Dwgs.pdf PDF
Amendment 14 - Nitrogren Overall Plan.pdf PDF
Amendment 14 - Panelboards.pdf PDF
Amendment 14 - 32 31 13.53.pdf PDF
Amendment 14 - Raychem RHW 2-hour fire-rated power cable.pdf PDF
Amendment 14 - Civil Site Dwgs.pdf PDF
Amendment 14 - 25 00 00.00 22_ASW_Control.pdf PDF
Amendment 14 - General Dwgs.pdf PDF
Amendment 13 - Hendersen Pt Site Dwgs.pdf PDF
Amendment 13 - General Dwgs.pdf PDF
Amendment 13 - Electrical Dwgs.pdf PDF
Amendment 13 - Mechanical Dwgs.pdf PDF
Amendment 13 - Structural Dwgs.pdf PDF
Amendment 13 - Geotech dwgs.pdf PDF
AMENDMENT 0013.pdf PDF
Amendment 0013 - Price Proposal Form (rev).pdf PDF
Amendment 13 - Civil Dwgs.pdf PDF
Amendment 13 - 40 95 00 App B - IO List.pdf PDF
Amendment 13 - Process dwgs.pdf PDF
AMENDMENT 0012.pdf PDF
Amendment 12 - Structural Drawings.pdf PDF
Amendment 12 - General Drawings.pdf PDF
Amendment 12 - 40 95 00 App B - IO List.pdf PDF
Amendment 12 - LightFixt_BOD_1_5_2021.pdf PDF
Amendment 12 - Pump Station and Utility Enclosure.pdf PDF
Amendment 12 - Electrical drawings.pdf PDF
Amendment 0011.pdf PDF
Amendment 10 - General dwgs.pdf PDF
Amendment 10 - Drydock 1 existing pumpwell valve arrangements drawings.pdf PDF
Amendment 10 - Geotech- Structural dwgs.pdf PDF
Amendment 10 - Architectural dwgs.pdf PDF
Amendment 10 - Electrical dwgs.pdf PDF
Amendment 10 - Mechanical.dwgs.pdf PDF
AMENDMENT 0010.pdf PDF
Amendment 10 - Civil dwgs.pdf PDF
Amendment 0009.pdf PDF
Amendment 8 - Structural.pdf PDF
01 50 00.00 22.pdf PDF
Amendment 8 - Geotech.pdf PDF
23 81 23.00 20.pdf PDF
Amendment 8 -Civil.pdf PDF
Amendment 8 -Structural Bld.pdf PDF
21 13 13.00 20.pdf PDF
Show 40 more

Latest 50 of 123 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAVD 88 Level 0.0

EL 0.00

UTILITY BUILDING

TUNNEL

EL -8.28

B3 M-316

A5 M-317

10"x16" SA

3/4" COND

EL: -10.97

14"ø SA

EL: -14.21

10"x16" SA

AHU-2

AHU-1

3/4" NI

4" WHCFSP

TYPICAL

4" WH

EL: 3.31

3/4" NI

EL: 3.46 1 1/4" CA

1" REF(V)

3/4" REF(L)

EL: 2.67

3/4" COND

EL: -15.41

EL: 3.43

1 1/4" CA

1" HPS

1" HPS8" ASWS

EL: 3.15

EL: 1.33

EL: 0.93

8" FW

FIRE

HYDRANT

EL: 1.25

SECTION GENERAL NOTES

1. PROVIDE LOW POINT DRAINS AND HIGH POINT

VENTS FOR ALL PIPING SYSTEMS. CONTRACTOR

MUST PROVIDE LOCATION OF ALL LOWER POINT

DRAINS AND HIGH POINT VENTS ON SHOP

DRAWINGS FOR REVIEW.

2. FINAL PIPE ELEVATIONS MUST BE DETERMINED BY

INSTALLATION CONTRACTOR AND MUST BE

PROVIDED ON AS-BUILT DRAWINGS AFTER FIELD

INSTALLATION.

NAVD 88 Level 0.0

EL 0.00

UTILITY BUILDING

TUNNEL

EL -8.28

C2 M-314

A3 M-317

16"ø SA

EL: -14.29

20"ø SA

EL: 1.08

4" WH

6" FW

3" CR

8" ASWR

2" PW

AHU-1

3/4" COND18"x20" RA 22"ø SA

20" X 18" RA 14"ø SA

EL: 3.87

EL: 2.45

1" HPA

3/4" NI8" ASWS

3/4" NI

1" HPA

8" HPS

3" CR

6" CA

TO DD1E TUNNEL

TO DD1E TUNNEL

6" FW

EL: -2.12

EL: 1.55

EL: 1.96

EL: 2.69

KI

TT

ER

Y, M

AI

N E

PO

R

TS

M

O U

TH

N

AV

AL

S H

IP

YA

R D

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

CA

PI

TA

L I

MP

RO

VE

ME

NT

C

OR

E

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

, V

IR

GI

NI

A

P-

M

U

LT

I-M

IS

SI

O

N D

R Y

D O

C K

#1

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C

LA

SS

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

Richard Powers, C980 10/15/20

C

U s er s\ Pu b l ic

\D oc u m en ts \L oc a l_ Re v i t_

Fil es

\D

RY

D S

W T R

-1

5 9

-M _d a rn ol d

.rv t

/3

0/

2 :

:0

PM

D D

1E P

U M

P W

EL

L

SE

C

TI

O

N S

- S H

EE

T

O

F

M-317

TJE DFA VAK

12823848 885 1029

SCALE: 1/4" = 1'-0" A3SECTION THRU PUMP WELL - LOOKING WEST

SCALE: 1/4" = 1'-0" A5

SECTION THRU SOUTHWEST CORNER OF PUMP

WELL - LOOKING SOUTH

AM

E N D

M

EN

T

/1 6/

VM

G

A4 M-301

C2 M-301

B2 M-301

DD1N TUNNEL

OUTLINE

IN TUNNEL

ROUTED

THROUGH

PUMP WELL

EXISTING

PUMP WELL

BELOW GRADE

IN TUNNELCENTER WALL

TUNNEL OUTLINE

C2 M-308

A2 M-308

6" FW

8" FW

8" FW

6" FW

6" FW

3" FW

M F1

M

F1

6" FW6" FW

REFER TO M-401

PUMPWELL

PARTIAL PLANS

6" FW

EXISTING

EXISTING 6" FW

REFER TO V-105

FOR

CONTINUATION

B2 M-303

B5 M-303

A2 M-313

C2 M-313

A5 M-313

6" FW

6" FW

10" FRESH WATER

FROM SITE - REFER

TO DWG CF102 FOR

CONTINUATION

C2 M-314

A4 M-314

A5 M-312

A2 M-3149

6" FW

A5 M-314

DD1N FW UTILITY

SERVICE CONNECTION 5

DD1N FW

UTILITY SERVICE

CONNECTION 6

DD1W FW

UTILITY SERVICE

CONNECTION 6

EXISTING DD1E FW

UTILITY SERVICE

CONNECTION 2

IN TUNNEL

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVE

ISOLATION

VALVE

ISOLATION

VALVE

ISOLATION

VALVE

B4 M-308

A4 M-308

M-405 A4

6" FW

UTILITY ENCLOSURE

REFER TO ASSOCIATED PLANS

HB-2

HB-1

HB-1

8" FW

ISOLATION

VALVE

6" FW

6" FW

KEY PLAN KI

TT

ER

Y, M

AI

N E

PO

R

TS

M

O U

TH

N

AV

AL

S H

IP

YA

R D

CHECK GRAPHIC SCALE BEFORE USING

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

GRAPHIC SCALE

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

CA

PI

TA

L I

MP

RO

VE

ME

NT

C

OR

E

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

, V

IR

GI

NI

A

P-

M

U

LT

I-M

IS

SI

O

N D

R Y

D O

C K

#1

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C

LA

SS

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

Richard Powers, C980 10/15/20

C

U s er s\ Pu b l ic

\D oc u m en ts \L oc a l_ Re v i t_

Fil es

\D

RY

D S

W T R

-1

5 9

-M _d a rn ol d

.rv t

/3

0/

2 :

:4

PM

FR

ES

H W

AT

ER

P

LA

N

D D

1N A

N D

C

EN

TE

R

W

AL

L

- E

AS

T

MF102

TJE DFA VAK

12823746 783 1029

PLAN NORTH

SCALE: 1/16" = 1'-0"

FRESH WATER PLAN - DD1N AND CENTER WALL - EAST 4' 0' 8' 16' 32' 64'

4' 12' 1/16" = 1'-0"

KEYNOTES

PROVIDE 6" FRESH WATER SERVICE WITH 6" AND 2-1/2"

CONNECTIONS. SEE DETAIL ON M-504.

PROVIDE 3" FW SERVICE WITH 2-1/2" AND 1-1/2"

CONNECTIONS. SEE DETAIL ON M-505.

TIE INTO EXISTING 6" FW WITHIN UTILITY TUNNEL WITH 6"

FW LINE. PROVIDE VALVE AT TIE IN. ROUTE MAIN THROUGH

PUMP WELL TO SERVE AS A CROSS CONNECTION BETWEEN

WITH THE UTILITY ENCLOSURE, CENTER WALL AND NORTH

SIDE OF DD1N.

ROUTE 8" FRESH WATER LINE FROM UTILITY ENCLOSURE.

REFER TO UTILITY ENCLOSURE DRAWINGS. THIS 8" LINE IS

INTENDED TO PROVIDE THE FW SERVICE TO THE CENTER

WALL FROM A 10" FW MAIN BELOW THE UTILITY ENCLOSURE.

PROVIDE 6" BYPASS AND VALVE BETWEEN 6" RPZs FOR

REDUNDANCY.

PROVIDE 6" REDUCED PRESSURE ZONE BACKFLOW

PREVENTER, FOR FW SERVICE CONNECTIONS. COORDINATE

MOUNTING OF BACKFLOW PREVENTER WITH

MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE

REQUIREMENTS. ROUTE DISCHARGE OF RPZ DIRECTLY

OVER THE NEAREST GUTTER DRAIN PIPE CONNECTION.

6" EXISTING FRESH WATER LINE UNDER WHARF STRUCTURE.

CORE DRILL THROUGH CONCRETE TO TRAVERSE 6" FW PIPE

MAIN FROM THE EXISTING DD1E TUNNEL INTO THE EXISTING

PUMPWELL. PROVIDE DOUBLE LINK SEAL AT ENTRY AND

EXIT WITHIN THE CONCRETE.

PROVIDE ISOLATION VALVE WITHIN TUNNEL FOR FRESH

WATER SERVICE CONNECTION IN HOT BOX. PROVIDE 3/4"

LOW POINT DRAIN AFTER VALVE.

PROVIDE 3/4" LOW POINT DRAIN AFTER RPZ IN TUNNEL.

CAP FRESH WATER PIPING AT VALVE WITHIN MANHOLE.

PROVIDE HYDRANT REFER TO CIVIL DRAWING CF102 FOR

MORE INFORMATION.

AM

E N D

M

EN

T

/1 6/

FE

M

FT

AO

BAS

BERTH 2

SHORE CONNECTIONS

EXISTING

DRY DOCK 1N

DRY DOCK 1W DRY DOCK 1E

6"-FW

8"-FW

6"-FW

8"-FW

BERTH 11C

SHORE CONNECTIONS

8"-FW

FROM SITE

6"x2-1/2"

8"x2-1/2"

6"-FW

12"-FW

8"x6"

6"-FW

8"x2-1/2" 8"x2-1/2"8"x4"

4" ASW

CONNECTION

6"x2-1/2" 6"x2-1/2"

12"x8"

12"x6"12"x8"

"-F

W

8" -F

W

6" -F

W

8"-FW

6" RPZ4" RPZ

8"x6"

6" RPZ

8"x6" 8"x6"

8"x6"

6" RPZ

8"x4" 8"x6"

6" RPZ

8"x3"

2-1/2"x3"

RPZ

8"x3"

2-1/2"x3"

RPZ

wHYD #36 w

8" -F

W

TO BERTH 12

FROM

SITE

FROM SITE

TO SITE

6"x3"

RPZ

2- 1/

2"

1- 1/

2"

6"x4"

RPZ

6"x3"

RPZ

DRY DOCK 1N

UTILITY SERVICE

CONNECTION 1

DRY DOCK 1N

UTILITY SERVICE

CONNECTION 2

DRY DOCK 1N

UTILITY SERVICE

CONNECTION 4

DRY DOCK 1N

UTILITY SERVICE

CONNECTION 5

DRY DOCK 1N

UTILITY SERVICE

CONNECTION 6

DRY DOCK 1W

UTILITY SERVICE

CONNECTION 2

DRY DOCK 1W

UTILITY SERVICE

CONNECTION 4

DRY DOCK 1W

UTILITY SERVICE

CONNECTION 6

DRY DOCK 1E

SERVICE GALLERY 1

EXISTING

DRY DOCK 1E

SERVICE GALLERY 3

EXISTING

DRY DOCK 1W

UTILITY SERVICE

CONNECTION 3

DRY DOCK 1W

UTILITY SERVICE

CONNECTION 5

DRY DOCK 1E

SERVICE GALLERY 4

EXISTING

DRY DOCK 1E

SERVICE GALLERY 5

EXISTING

DRY DOCK 1E

SERVICE GALLERY 6

EXISTING

DRY DOCK 1W

UTILITY SERVICE

CONNECTION 1

DRY DOCK 1E

SERVICE GALLERY 2

EXISTING

6"x3"

RPZ

8"x6"

8"-FW

6" -F

W

2- 1/

2"

8"x6"

8"-FW

6"x3"

RPZ

6"x3"

RPZ

6"x3"

RPZ

8"x6"

6"x3"

RPZ

6"x4"

RPZ

6"x3"

RPZ

BERTH 11B SHORE

CONNECTION

10" FW

SERVICE

10"-FW

4"

UM710

UE FRESH WATER SCHEMATIC

TO UTILITY ENCLOSURE

8"x6"

2- 1/

2"

1- 1/

2"

2- 1/

2"

1- 1/

2"

2- 1/

2"

2- 1/

2" 4"

1- 1/

2"

2- 1/

2"

2- 1/

2"

10"x12"

2- 1/

2"

1- 1/

2"

2- 1/

2"

1- 1/

2"

4" 2- 1/

2"

1- 1/

2"

6"6"

3"x8"

6"

6" FW FOR

ASW BACKUP

6" FW FOR

ASW BACKUP

6" FW FOR

ASW BACKUP

6"

6" FW FOR

ASW BACKUP 4" FW FOR

GENERATOR

TESTING

4" FW FOR

GENERATOR

TESTING

3"x2"

2" RPZ

TO PUMP

STATION

SEE PM102

10"x8"

4" RPZ

DRY DOCK 1N

UTILITY SERVICE

CONNECTION 3

4" 1- 1/

2"

2- 1/

2"

6"x4"

6"x4"

NC

6" -F

W

PUMP STATION

BOUNDARY

UTILITY

ENCLOSURE

BOUNDARY

HYDRANT

10"x8"

8" -F

W

6"

NC

6"

GENERAL NOTES

1. REFER TO M-001 FOR SYMBOLS AND ABBREVIATIONS.

2. NOT ALL COMPONENTS ARE SHOWN. REFER TO DETAILS

AND SPECIFICATIONS FOR FURTHER REQUIREMENTS.

KI

TT

ER

Y, M

AI

N E

PO

R

TS

M

O U

TH

N

AV

AL

S H

IP

YA

R D

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

CA

PI

TA

L I

MP

RO

VE

ME

NT

C

OR

E

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

, V

IR

GI

NI

A

P-

M

U

LT

I-M

IS

SI

O

N D

R Y

D O

C K

#1

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C

LA

SS

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

Richard Powers, C980 10/15/20

C

U s er s\ Pu b l ic

\D oc u m en ts \L oc a l_ Re v i t_

Fil es

\D

RY

D S

W T R

-1

5 9

-M _d a rn ol d

.rv t

/3

0/

2 :

:3

PM

FR

ES

H W

AT

ER

S C

H

EM

AT

IC

MF701

TJE DFA VAK

12823751 788 1029

N.T.S.

A4FRESH WATER SCHEMATIC

AM

E N D

M

EN

T

/1 6/

1 2

4"ø

6"ø

4"ø

/1

15 15

8' - 0"

7' - 3"

13 13

16 4"ø 4"ø

7' - 3"

4"ø

10 10 1011

16SCALE: 3/8" = 1'-0" MH101 C3

1 - UTILITY TUNNEL SECTION

SCALE: 3/4" = 1'-0" A2

2 - PLAN VIEW OF HOSE MANIFOLD

DETAIL

SEE DETAIL A2 BELOW

SCALE: 1/2" = 1'-0" A3

3 - ELEVATION VIEW OF HOSE

MANIFOLD

KEYNOTES

FINISHED FLOOR OF

UTILITY TUNNEL

GRADE OF CENTERWALL

GRADE OF

CENTERWALL

CEILING OF UTILITY TUNNEL

EDGE OF CENTERWALL

8 - INCH DRYDOCK NORTH MANIFOLD MAIN

8 - INCH DRYDOCK WEST MANIFOLD MAIN

HEATED ENCLOSURE. REFER TO THE SCHEDULE ON THIS

DRAWING AND MECHANICAL DRAWINGS FOR FURTHER

INFORMATION.

PROVIDE 2-INCH SCHEDULE 40 BLACK STEEL PIPING FROM

FP-HTX OUTLET TO 4-INCH BY 2-INCH TEE DOWNSTREAM

OF FIRST BRANCH CHECK VALVE. REFER TO MH701 FOR

CONNECTION ORDER.

PROVIDE 2-INCH SCHEDULE 40 BLACK STEEL PIPING TO

FP-HTX PUMP INLET FROM 4-INCH BY 2-INCH REDUCER OR

TEE DOWNSTREAM OF LAST CHECK VALVE. REFER TO

MH701 FOR CONNECTION ORDER.

SPRINKLER PIPING. SEE SHEET MH100 FOR PIPE

CONTINUATION.

4 - INCH CHECK VALVE

6 - INCH CHECK VALVE

FIRE PROTECTION FREEZE PROTECTION HEAT

EXCHANGER, FP-HTX. REFER TO MECHANICAL DRAWINGS

FOR MORE DETAILS.

BUTTERFLY VALVE

2.5 - INCH FIRE HOSE CONNECTION

4 - INCH TEMPORARY FIRE MAIN CONNECTION

PROVIDE DRAIN VALVE. PIPE TO NEAREST TUNNEL FLOOR

DRAIN, SEE SHEET MR102 FOR FLOOR DRAIN LOCATIONS.

2 - INCH CHECK VALVE

PROVIDE LOW POINT DRAIN. SEE SHEET MR102 FOR

FLOOR DRAIN LOCATIONS.

PROVIDE MANUAL AIR VENT AT SYSTEM HIGH POINT

PROVIDE PIPE

SUPPORT WITH

STEEL SADDLE

AND STEEL CLAMP

TYPICAL

12823756

793 1056

THESE ARROWS

INDICATE FLOW DIRECTION

ALL PENETRATIONS SEALS

TO HAVE LINK SEAL

ALL PENETRATION SEALS TO

HAVE LINK SEAL

HOT BOX ENCLOSURE SCHEDULE

HOT BOX IDENTIFICATION LOCATION SYSTEM CONNECTIONS (NUMBER AND SIZE) BOX INTERNAL DIMENSIONS INSULATION ACCESS PANELS UNIT HEATERS HOSE MANIFOLD HOT BOX A-D CENTERWALL (1) 2 1/2" (2) 4" 7'-0"(L) 3'-0"(W) 5'-1"(H) 1.5" (2) 33" x 56" H (2)1900W 120V 1PH HOSE MANIFOLD HOT BOX E-F CENTERWALL (1) 2 1/2" (3) 4" 7'-0"(L) 3'-0"(W) 5'-1"(H) 1.5" (2) 22" x 56" H (2)1900W 120V 1PH

PROVIDE PIPE

SUPPORT WITH

STEEL SADDLE

AND STEEL CLAMP

TYPICAL

PROVIDE PIPE

SUPPORT WITH

STEEL SADDLE

AND STEEL CLAMP

TYPICAL

1/4" FILLET WELD ALL AROUND

4" DIAMETER SCHEDULE 40

PIPE GALVANIZED

GALVANIZED

PLATE 8"X8"X1/2"

WITH (4) 3/4"

DIAMETER

EXPANSION

ANCHORS. 4"

MINIMUM

EMBEDMENT

KEY

K

IT

T E

R Y

M

A

IN

E P

O R

T S

M O

U T

H N

A V

A L S

H

IP

Y A

R D

CHECK GRAPHIC SCALE BEFORE

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E

INFO

S Y

M D

E S

C R

IP

T

IO

N

D A

T A

P P

SHEE

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

GRAPHIC

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

C A

P

IT

A L I

M P

R O

V E

M E

N T

C O

R E

N A

V A

L S

T A

T

IO

N N

O R

F O

L K

V

IR

G

IN

IA

P -3

M

U L T

I- M

IS

S

IO

N

D R

Y D

O C

K

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C L A S S

IF

IE

D

UNCLASSIFIED

EJA

DSN

NBJ

LBT/LBL

1604959

DES DRW CHK

CONSTR. CONTR. NO.

SCALE: AS SHOWN

Richard Powers, C980 10/15/20

Y

S h a re d

Le g a c y

U S

W K

F D

P ro j\

J e n s e n H u g h e s\ K u rt

R u c h a la

K A

R

.0

P

N S Y

P -3

D ry

D o c k

D ra w in g s\

R e v it

D R

Y D

S W

TR

-1

-F

- 1

-2

.r v t

/6 /2

:2

:2

A

M

F

IR

E P

R O

T E

C T

IO

N

S E

C T

IO

N

S A

N D

D E

T A

IL

S

MH301

MRD MRD KAR

D a te

/1

/2

V M

G

1KAR00083.000

Am en dm en t 0

GROUND LEVEL

EL 12.00

UTILITY BUILDING

TUNNEL

EL -8.28

4" VENT UP

THROUGH

UTILITY

ENCLOSURE

ROOF

8" ASWS

8" ASWR

B3 M-316

UE-CRU-1

4" SS

10" FW

2 1/2" VENT

8"x8" SA

8"x8" SA

1/2" HPS

UE-PRV-02

1 1/2" HPS

1 1/2" HPS

1 1/2" CR

3/4" HPC

2" LPC

4" VENT

1 1/2" CR

10"x10" SA

6" FW

1 1/2" CR

2" HPS

3" CR

2" PW

3" DR

6" CA

ACCU-2

4" SS

4" VENT

8" HPS

3" CR

8" ASWS

FP8"ø

6" SS

4" SS

SECTION GENERAL NOTES

1. PROVIDE LOW POINT DRAINS AND HIGH POINT

VENTS FOR ALL PIPING SYSTEMS. CONTRACTOR

MUST PROVIDE LOCATION OF ALL LOWER POINT

DRAINS AND HIGH POINT VENTS ON SHOP

DRAWINGS FOR REVIEW.

2. FINAL PIPE ELEVATIONS MUST BE DETERMINED BY

INSTALLATION CONTRACTOR AND MUST BE

PROVIDED ON AS-BUILT DRAWINGS AFTER FIELD

INSTALLATION.

KI

TT

ER

Y, M

AI

N E

PO

R

TS

M

O U

TH

N

AV

AL

S H

IP

YA

R D

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

CA

PI

TA

L I

MP

RO

VE

ME

NT

C

OR

E

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

, V

IR

GI

NI

A

P-

M

U

LT

I-M

IS

SI

O

N D

R Y

D O

C K

#1

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C

LA

SS

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

Richard Powers, C980 10/15/20

C

U s er s\ Pu b l ic

\D oc u m en ts \L oc a l_ Re v i t_

Fil es

\D

RY

D S

W T R

-1

5 9

-M _d a rn ol d

.rv t

/3

0/

2 :

:5

PM

U

TI

LI

TY

E N

C

LO

SU

R

E

- S

EC

TI

O N

SH

EE

T

O

F

UM304

TJE DFA VAK

12823622 659 1029

SCALE: 3/8" = 1'-0" A3

UTILITY ENCLOSURE - TUNNEL SECTION

LOOKING EAST

KEYNOTES

REFER TO DRAWING M-501 FOR ADDITIONAL INFORMATION

REGARDING PIPE PENETRATION THROUGH WALL.

AM

EN

D

M

EN

T

/1 6/

PI

PI

FE

FT

PI

TCV

ZC

PI

M

M

ST

ST

UM711

LPS SCHEMATIC

SAFETY SHOWER/

EYEWASH

MV-1

UE-WH-1

MS703

ASW SCHEMATIC DD1W

MF701

FRESH WATER SCHEMATIC

10" FW MAKE

UP TO FP

ASSEMBLY

10" FW

" F

W

10" FW

10"x4"

4" FW

4"x2"

RPZ-1

4" RPZ FOR

MECHANICAL

MAKE UP

RPZ-2

2" RPZ FOR

DOMESTIC NON-

POTABLE WATER

UTILITY ENCLOSURE

THIRD FLOOR

UTILITY ENCLOSURE

SECOND FLOOR

UTILITY ENCLOSURE

GROUND FLOOR

UTILITY ENCLOSURE

TUNNEL

UE-SK-1

3/4" LPC

UM711

LPS SCHEMATIC

4" F

W

4" F

W

2 1/2" LPS

PLATE AND

FRAME HEAT

EXCHANGER

2" F

W

2" F

W

3/4" FW 1/2" FW

1/ 2"

F W

UE-ESS-1

PLATE AND FRAME HEAT EXCHANGER SKID - UE-HEX-1

INTEGRAL

MIXING VALVE

1/ 2"

F W

2" F

W

1" FW

1-1/2" FW

CONTROL

PANEL

1/ 2"

F W

1" F

W

1-1/4" FW

1" FW

3/4" FW 3/4" FW

UE-TP-1

UE-FS-1UE-FS-1

1/2" FW

UE-TP-1

1/2" FW

UE-FS-1UE-FS-1

3/4" FW

1" FW

UE-TP-1

1/2" FW

UE-FS-1UE-FS-1

3/4" FW

UE-TP-1

1/2" FW

UE-FS-1

3/4" FW

UE-TP-1

1/2" FW

UE-FS-1

3/4" FW

UM712

PW GENERATION SCHEMATIC

1 1

GENERAL NOTES

1. REFER TO UM003 FOR SYMBOLS AND

ABBREVIATIONS.

2. REFER TO UM103 FOR BID OPTION REQUIREMENTS.

KI

TT

ER

Y, M

AI

N E

PO

R

TS

M

O U

TH

N

AV

AL

S H

IP

YA

R D

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

CA

PI

TA

L I

MP

RO

VE

ME

NT

C

OR

E

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

, V

IR

GI

NI

A

P-

M

U

LT

I-M

IS

SI

O

N D

R Y

D O

C K

#1

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C

LA

SS

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

Richard Powers, C980 10/15/20

C

U s er s\ Pu b l ic

\D oc u m en ts \L oc a l_ Re v i t_

Fil es

\D

RY

D S

W T R

-1

5 9

-M _d a rn ol d

.rv t

/3

0/

2 :

:4

PM

U

TI

LI

TY

E N

C

LO

SU

R

E

- F

R

ES

H W

AT

ER

S C

H

EM

AT

IC

UM710

TJE DFA VAK

12823644 681 1029

N.T.S.

A4

UTILITY ENCLOSURE FRESH WATER

SCHEMATIC

UM710 CONTROL POINTS LIST

ABBREVIATION NUMBER POINT DESCRIPTION ASSOCIATED EQUIPMENT P&ID NUMBER SIGNAL TYPE

SOFTWARE POINTS

COMMENT

SALARM TREND

SCADA

MONITORING

FT 01 UE FRESH WATER METER UE FRESH WATER METER UM710 AI No Yes No ZC 01 LPS VALVE POSITION CONTROL UE WATER HEATER HEAT EXCHANGER UM710 AO No Yes Yes

AM

EN

D

M

EN

T

/1 6/

D

D.4 E F

5.3

A2

UM303

A3

UM304

6"Ø SS TO

SITE/CIVIL

CONNECTION

C

A3 M-317

4"Ø PUMPED

SS TO

SITE/CIVIL

CONNECTION

CO

CO

6"Ø SS FROM

LEVEL ABOVE

4" SS

4"Ø SS FROM

LEVEL ABOVE

UE-CRU-1

8" FW

4" SS

8" FW

3" DR

6" SS

6"Ø ST FROM

LEVEL ABOVE

6"Ø ST TO

SITE/CIVIL

CONNECTION

3" DR

3" DR

UE-FD-1

B4 M-308

A4 M-308

M-401

3" DR

8" FW

BOP: 13' - 9"

BOP: 13' - 9"

SLOPE AT MINIMUM OF 1%

BOP: 13' - 9"

4" SS

10" FW

BOP: 7' - 8"

BOP: 12' - 11"

BOP: -2' - 8"

BOP: 12' - 2"

BOP: 12' - 1"

BOP: 14' - 0"

BOP: 14' - 3"

BOP: 7' - 0"

BOP: 9' - 6"BOP: 12' - 11"

BOP: 8' - 6"

BOP: 8' - 6"

BOP: 7' - 11"

BOP: 11' - 11"

ISOLATION

VALVE

ISOLATION

VALVE

GENERAL NOTES

1. BOD AND BOP ELEVATIONS ARE

RELATIVE TO THE ASSOCIATED

FLOOR ELEVATION.

KEY PLAN KI

TT

ER

Y, M

AI

N E

PO

R

TS

M

O U

TH

N

AV

AL

S H

IP

YA

R D

CHECK GRAPHIC SCALE BEFORE USING

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

GRAPHIC SCALE

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

CA

PI

TA

L I

MP

RO

VE

ME

NT

C

OR

E

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

, V

IR

GI

NI

A

P-

M

U

LT

I-M

IS

SI

O

N D

R Y

D O

C K

#1

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C

LA

SS

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

Richard Powers, C980 10/15/20

C

U s er s\ Pu b l ic

\D oc u m en ts \L oc a l_ Re v i t_

Fil es

\D

RY

D S

W T R

-1

5 9

-M _d a rn ol d

.rv t

/3

0/

2 :

:5

PM

U

TI

LI

TY

E N

C

LO

SU

R

E

- T

U N

N

EL

P

LU

M

BI

N G

P

LA

N

UP101

TJE DFA VAK

12823655 692 1029

PLAN NORTH

SCALE: 1/4" = 1'-0"

UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN

KEYNOTES

10"Ø FW UP

3"Ø PIPING RUNNING BELOW SLAB.

PIPING CONTINUATION TO TUNNEL. REFER TO M-801.

6"Ø FW UP TO HYDRANT AT GRADE. REFER CIVIL DRAWING,

CF102 FOR MORE INFORMATION.

PROVIDE GEAR OPERATED BUTTERFLY VALVE. VALVE

SHALL BE PREWIRED WITH A TAMPER SWITCH FOR FIRE

ALARM MONITORING. VALVE MUST BE FM APPROVED AND

RATED FOR POTABLE WATER SERVICE. REFER TO FIRE

PUMP ROOM RISER DIAGRAM ON UR701 FOR FURTHER

INFORMATION.

4' 0' 4' 8' 1/4" = 1'-0"

AM

EN

D

M

EN

T

/1 6/

A3

UM301

D

D.4 E F

3.3

5.3

WHEELER

4"Ø ST TO

DAY LIGHT

6"Ø ST TO

DAY LIGHT

6"Ø ST UP

AND DOWN

3"Ø ST TO DAY LIGHT

3" ST

6" ST

C

C4

UM303

A4

UM303

2"Ø SS FROM

LEVEL ABOVE

UE-FD-1

4" SS

4"Ø SS DOWN,

3"Ø SS VENT

UP

6"Ø SS

DOWN

6"Ø SS FROM

LEVEL ABOVE

6" SS

6" SS4" SS

2" SS

4" SS

4" SS

3" SS

3"Ø ST FROM

LEVEL ABOVE

3"Ø SS

VENT UP CO

3" SS

3" SS

CO

10"Ø FW TO FIRE PUMP.

SEE DRAWING UF301

FOR CONTINUATION

4"Ø FW UP

2"Ø FW

UP

4"Ø FW

VALVE AND

CAP FOR

FUTURE

6"Ø ST FROM

LEVEL ABOVE

CO

4"Ø ST FROM

LEVEL ABOVE

4"Ø SS PIPING

RUN IN SLAB

UE-FD-1

CO

GENERAL NOTES

1. BOD AND BOP ELEVATIONS ARE

RELATIVE TO THE ASSOCIATED

FLOOR ELEVATION.

KEY PLAN KI

TT

ER

Y, M

AI

N E

PO

R

TS

M

O U

TH

N

AV

AL

S H

IP

YA

R D

CHECK GRAPHIC SCALE BEFORE USING

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

GRAPHIC SCALE

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

CA

PI

TA

L I

MP

RO

VE

ME

NT

C

OR

E

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

, V

IR

GI

NI

A

P-

M

U

LT

I-M

IS

SI

O

N D

R Y

D O

C K

#1

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C

LA

SS

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

Richard Powers, C980 10/15/20

C

U s er s\ Pu b l ic

\D oc u m en ts \L oc a l_ Re v i t_

Fil es

\D

RY

D S

W T R

-1

5 9

-M _d a rn ol d

.rv t

/3

0/

2 :

:0

PM

U

TI

LI

TY

E N

C

LO

SU

R

E

- G

R O

U N

D F

LO

O

R P

LU

M

BI

N

G P

LA

N

UP102

TJE DFA VAK

12823656 693 1029

PLAN NORTH

SCALE: 1/4" = 1'-0"

UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN

KEYNOTES

3"Ø SS FROM UE-FD-1 ON LEVEL ABOVE.

6"Ø SS FROM UE-FS-1 ON LEVEL ABOVE.

ULTRASONIC FLOW METER.

PROVIDE 4" GEAR OPERATED BUTTERFLY VALVE IN THE

VERTICAL FOR BUILDING ISOLATION.

4' 0' 4' 8' 1/4" = 1'-0"

AM

EN

D

M

EN

T

/1 6/

M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
Sheets
G-144 - ENLARGED DECK PLAN - UTILITY ENCLOSURE AREA
M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
MF701 - FRESH WATER SCHEMATIC
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
Sheets
G-144 - ENLARGED DECK PLAN - UTILITY ENCLOSURE AREA
M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
MF701 - FRESH WATER SCHEMATIC
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
MF701 - FRESH WATER SCHEMATIC
Sheets
G-144 - ENLARGED DECK PLAN - UTILITY ENCLOSURE AREA
M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
MF701 - FRESH WATER SCHEMATIC
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
MH301 - FIRE PROTECTION SECTIONS AND DETAILS
Sheets
MH301 - FIRE PROTECTION SECTIONS AND DETAILS
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
Sheets
G-144 - ENLARGED DECK PLAN - UTILITY ENCLOSURE AREA
M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
MF701 - FRESH WATER SCHEMATIC
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
Sheets
G-144 - ENLARGED DECK PLAN - UTILITY ENCLOSURE AREA
M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
MF701 - FRESH WATER SCHEMATIC
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
Sheets
G-144 - ENLARGED DECK PLAN - UTILITY ENCLOSURE AREA
M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
MF701 - FRESH WATER SCHEMATIC
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
Sheets
G-144 - ENLARGED DECK PLAN - UTILITY ENCLOSURE AREA
M-317 - DD1E PUMP WELL SECTIONS - SHEET 2 OF 2
MF102 - FRESH WATER PLAN - DD1N AND CENTER WALL - EAST
MF701 - FRESH WATER SCHEMATIC
UM304 - UTILITY ENCLOSURE - SECTION - SHEET 4 OF 4
UM710 - UTILITY ENCLOSURE - FRESH WATER SCHEMATIC
UP101 - UTILITY ENCLOSURE - TUNNEL PLUMBING PLAN
UP102 - UTILITY ENCLOSURE - GROUND FLOOR PLUMBING PLAN
2020-12-07T13:19:56-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:20:46-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:21:12-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:21:38-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:22:03-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:22:27-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:23:12-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:23:38-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:24:34-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:24:52-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:24:55-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:24:58-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:25:01-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:25:04-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:25:07-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-12-07T13:25:10-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.

File details come from the government source that posted it. Updated .