Amendment 14 - Fire Protection One Line.pdf

PDF 182 KB Posted

Attached to
P-381 MULTI-MISSION DRY DOCK #1, PORTSMOUTH NAVAL SHIPYARD (PNSY), KITTERY MAINE
Solicitation number
N4008520R0021
Issued by

About this file

This document contains a schematic drawing amendment and related federal contract opportunity solicitation. The schematic drawing amendment shows revisions to the fire protection system for the P-381 Multi-Mission Dry Dock #1 project at the Portsmouth Naval Shipyard in Kittery, Maine. The federal contract opportunity solicitation is for the design-bid-build construction of the P-381 Multi-Mission Dry Dock #1 project. The project scope includes constructing a partitioned addition to Dry Dock #1 within the superflood basin area consisting of two bays labeled Dry Dock #1 North and Dry Dock #1 West. The existing Dry Dock #1 will be renamed Dry Dock #1 East. The addition will support maintenance and overhaul of Virginia Class submarines. The solicitation is issued by the Department of the Navy Naval Facilities Engineering Command for offers due by the response date specified.

View the file

Other files

File Type Posted
AMENDMENT 0015.pdf PDF
Amendment 14 - 25 00 00.00 22.pdf PDF
Amendment 14 - Electrical dwgs.pdf PDF
AMENDMENT 0014.pdf PDF
Amendment 14 - Mechanical Dwgs.pdf PDF
Amendment 14 - Electrical One Line.pdf PDF
Amendment 14 - Henderson Point Dwgs.pdf PDF
Amendment 14 - Nitrogren Overall Plan.pdf PDF
Amendment 14 - Panelboards.pdf PDF
Amendment 14 - 32 31 13.53.pdf PDF
Amendment 14 - Raychem RHW 2-hour fire-rated power cable.pdf PDF
Amendment 14 - Civil Site Dwgs.pdf PDF
Amendment 14 - 25 00 00.00 22_ASW_Control.pdf PDF
Amendment 14 - General Dwgs.pdf PDF
Amendment 13 - Hendersen Pt Site Dwgs.pdf PDF
Amendment 13 - General Dwgs.pdf PDF
Amendment 13 - Electrical Dwgs.pdf PDF
Amendment 13 - Mechanical Dwgs.pdf PDF
Amendment 13 - Structural Dwgs.pdf PDF
Amendment 13 - Geotech dwgs.pdf PDF
AMENDMENT 0013.pdf PDF
Amendment 0013 - Price Proposal Form (rev).pdf PDF
Amendment 13 - Civil Dwgs.pdf PDF
Amendment 13 - 40 95 00 App B - IO List.pdf PDF
Amendment 13 - Process dwgs.pdf PDF
AMENDMENT 0012.pdf PDF
Amendment 12 - Structural Drawings.pdf PDF
Amendment 12 - General Drawings.pdf PDF
Amendment 12 - 40 95 00 App B - IO List.pdf PDF
Amendment 12 - LightFixt_BOD_1_5_2021.pdf PDF
Amendment 12 - Pump Station and Utility Enclosure.pdf PDF
Amendment 12 - Electrical drawings.pdf PDF
Amendment 0011.pdf PDF
Amendment 10 - General dwgs.pdf PDF
Amendment 10 - Drydock 1 existing pumpwell valve arrangements drawings.pdf PDF
Amendment 10 - Geotech- Structural dwgs.pdf PDF
Amendment 10 - Architectural dwgs.pdf PDF
Amendment 10 - Electrical dwgs.pdf PDF
Amendment 10 - Mechanical.dwgs.pdf PDF
AMENDMENT 0010.pdf PDF
Amendment 10 - Civil dwgs.pdf PDF
Amendment 0009.pdf PDF
Amendment 8 - Structural.pdf PDF
Amendment 8 -mechanical.pdf PDF
01 50 00.00 22.pdf PDF
Amendment 8 - Geotech.pdf PDF
23 81 23.00 20.pdf PDF
Amendment 8 -Civil.pdf PDF
Amendment 8 -Structural Bld.pdf PDF
21 13 13.00 20.pdf PDF
Show 40 more

Latest 50 of 123 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10" DEDICATED SUPPLY

FROM 12" YARD MAIN

6" FP

6" FP

F P

1-1/2" FP

F P

JOCKEY

PUMP

1-1/2" FP

JOCKEY

PUMP

FIRE PUMP A

6" FP

FIRE PUMP B

8" FP

F P

F P

TEST HEADER

1-1/2" FP

1-1/2" FP

RPZ

8" FP

8" FP

TO SPRINKLER SYSTEMS

4" FP

FDC - PS & UE

6" FP

4" FP

8" FP

8" FP

UTILITY ENCLOSURE FIRE PUMP ROOM

FDC - DD1N

4" FP

FDC - DD1W

4" FP

F P

F P

8" FP

8" FP

2" FP

8" FP

8" FP

4" FP

F P

R E

T U

R N

H O

S E

F P

S U

P P

L Y

H O

S E

SHIPBOARD

FIRE SERVICE

SHIPBOARD

FIRE SERVICE

SHIPBOARD

FIRE SERVICE

4" FP

NOTE:

LIGHT GREY COMPONENTS ARE THE

SCOPE OF CODE 230 TEMPORARY

SERVICES. WHAT IS SHOWN IS FOR

ILLUSTRATIVE PURPOSES ONLY.

NOTE:

LIGHT GREY COMPONENTS ARE THE

SCOPE OF CODE 230 TEMPORARY

SERVICES. WHAT IS SHOWN IS FOR

ILLUSTRATIVE PURPOSES ONLY.

TEMPORARY SB HOSE LOOP ONLY

ILLUSTRATED ON DD1N FOR CLARITY

F P

F P

2" FP

F P

F P

TEMPORARY DD HOSE LOOP ONLY

ILLUSTRATED ON DD1W FOR CLARITY

F P

TEMPORARY DD HOSE LOOP ONLY

ILLUSTRATED ON DD1W FOR CLARITY

F P

SPARE UTILITY CONNECTION

DRYDOCK

FIRE

SERVICE

DRYDOCK

FIRE

SERVICE

DRYDOCK

FIRE

SERVICE

DRYDOCK

FIRE

SERVICE

8" FP

HEATED WET

UTILITY

ENCLOSURE

HEATED WET

UTILITY

ENCLOSURE

FM

F P

TEMPERATURE

GAUGE

VACUUM

BREAKER

TO TUNNEL

CONDENSATE

PRESSURE

RELIEF VALVE

FM

FROM

TUNNEL HPS

TEMPERATURE

GAUGE

FP FREEZE PROTECTION HEAT EXCHANGER SKID

F P

TEMPERATURE

GAUGE

VACUUM

BREAKER

TO TUNNEL

CONDENSATE

PRESSURE

RELIEF VALVE

FM

FROM

TUNNEL HPS

TEMPERATURE

GAUGE

FP FREEZE PROTECTION HEAT EXCHANGER SKID

F P

TEMPERATURE

GAUGE

VACUUM

BREAKER

TO TUNNEL

CONDENSATE

PRESSURE

RELIEF VALVE

FM

FROM

TUNNEL HPS

TEMPERATURE

GAUGE

FP FREEZE PROTECTION HEAT EXCHANGER SKID

TEMPERATURE

GAUGE

VACUUM

BREAKER

TO TUNNEL

CONDENSATE

PRESSURE

RELIEF VALVE

FROM

TUNNEL HPS

TEMPERATURE

GAUGE

2" FP

FP FREEZE PROTECTION HEAT EXCHANGER SKID

FM

TEMPERATURE

GAUGE

VACUUM

BREAKER

TO TUNNEL

CONDENSATE

PRESSURE

RELIEF VALVE

FROM

TUNNEL HPS

TEMPERATURE

GAUGE

FP FREEZE PROTECTION HEAT EXCHANGER SKID

FM

TEMPERATURE

GAUGE

VACUUM

BREAKER

TO TUNNEL

CONDENSATE

PRESSURE

RELIEF VALVE

FROM

TUNNEL HPS

TEMPERATURE

GAUGE

FP FREEZE PROTECTION HEAT EXCHANGER SKID

-1

/2

F P

F P

2" FP

F P

F P

2" FP

-1

/2

F P

2-1/2" FP

-1

/2

-1

/2

2" FP

F P

2" FP

-1

/2

F P

2-1/2" FP

2" FP

F P

2" FP

-1

/2

F P

2-1/2" FP

MANUAL AIR VENT

HEATED WET

UTILITY

ENCLOSURE

MANUAL AIR VENT

HEATED WET

UTILITY

ENCLOSURE

MANUAL AIR VENT

MANUAL AIR VENT MANUAL AIR VENT MANUAL AIR VENT

GENERAL NOTES

1. REFER TO M-001 FOR SYMBOLS AND ABBREVIATIONS.

2. NOT ALL COMPONENTS ARE SHOWN. REFER TO DETAILS

AND SPECIFICATIONS FOR FURTHER REQUIREMENTS.

K

IT

T E

R Y

M

A

IN

E P

O R

T S

M O

U T

H N

A V

A L S

H

IP

Y A

R D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

C A

P

IT

A L

I M

P R

O V

E M

E N

T C

O R

E N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

V

IR

G

IN

IA

P -3

M

U L T

I- M

IS

S

IO

N

D R

Y D

O C

K

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C L A S S

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

C

U se rs

P u b lic

D o c u m e n ts

L o c a l_ R e v it

F ile s\ D

R Y

D S

W

TR

-1

-M te n v id

.r v t

/1

/2

:3

:3

P

M

F

IR

E P

R O

T E

C T

IO

N

S C

H E

M A

T

IC

MH701

TJE DFA VAK

12823757

794 1029N.T.S.

A5

FIRE PROTECTION SCHEMATIC

A

M E

N D

M E

N T

/1 /2

V

M G

Sheets
MH701 - FIRE PROTECTION SCHEMATIC
MN100 - NITROGEN OVERALL PLAN

File details come from the government source that posted it. Updated .