Amendment 10 - Geotech- Structural dwgs.pdf
PDF 15 MB Posted
- Solicitation number
- N4008520R0021
About this file
This document provides details on a federal contract solicitation for construction services. The solicitation is for the design and construction of a partitioned addition to Dry Dock #1 at the Portsmouth Naval Shipyard in Kittery, Maine. The addition will include two new dry dock bays labeled Dry Dock #1 North and Dry Dock #1 West, with the existing dry dock being renamed Dry Dock #1 East. The new construction will involve concrete floors, walls and center wall; new pump well systems and a pump station building; portal crane rails; mooring hardware; and mechanical and electrical utilities to create two operational dry docks capable of supporting maintenance and overhaul of Virginia Class submarines. Modifications will also be made to the existing dry dock closure wall and berths. Bids are due by the Department of the Navy Naval Facilities Engineering Command for this design-build project located at the Portsmouth Naval Shipyard in Kittery, Maine.
View the file
Other files
Show 40 more
Latest 50 of 123 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0+
2+
3+
4+
5+
6+
0+
2+
3+
4+
5+
6+
20+00
21+00
22+00
23+00
23+351+75
2+00
3+00
4+00
4+75
0+
1+
2+
3+
4+
5+
1+
6+
1+
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
FI
LE
N
AM
E:
U s0
4-pp fs s0 1\ sh ar ed _p ro je ct s\
4\
.0 _s ha re d_ bi m \d w g\
EX
C
AV
AT
IO
N
D R
AW
IN
G S\
BY
1.
dw g L
AY
O
U T
N
AM
E:
B
Y1
P
LO
TT
ED
: W ed ne sd ay , D ec em be r 1
6,
- 1 0:
pm
U
SE
R : c ni co la e
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
EPROJECT NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
SEAL
OF
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
DRAWFORM REVISION: 07 AUG 2018
CHECK GRAPHIC SCALE BEFORE USING
P-
- M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1KEY PLAN
GRAPHIC SCALE 1604959
DRWDES CHK
CONSTR. CONTR. NO.
SCALE:
A / E INFO
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
KI
TT
ER
Y, M
AI
N E
AS SHOWN
PLAN
NORTH
DRY DOCK DRILLED SHAFTS - PLAN
SCALE: 1"=30'-0"
1" = 30' 30' 0 30' 60'
D R
Y D
O C
K D
R
IL
LE
D
S H
AF
TS
P
LA
N
67.00'
DD1W ENTRANCE
STRUCTURE
405.36'
BERTH 1
EXISTING
DD1E101.00'
SOUTH CLOSURE WALL
CL DD1W
CL CENTER WALL
CL DD1N
EXISTING
PUMPWELL
6'-6" DIA DRILLED SHAFT (TYP)
BY101
39.00' 15.75'
.5
0'
.0
0'
.0 0'
1.17'
2.50'
A
B
C
D
E
F
G
H
J
K
0.511.522.533.544.555.566.577.588.599.51010.51111.51212.51313.51414.515.51616.51717.5181920
34 SPACES @ 13.75' = 467.50'
EA
EC
ED
EE
.5
0'
.5 0'
.2
5'
4.
4.
12.31'
28.32'
PUMPWELL AND UTILITY ENCLOSURE
DRILLED SHAFTS (SEE BY102)
.0
0'
.0
0'
8.
.0 0'
14.00'
.0
0'
EB
.7
6'
.5
0'
.5
0'
.7
5'
OUTER EXTENT
OF PIT (TYP, 4)
'A'
'D' 'C'
'C'
'D'
'B'
'A'
'B'
REFERENCE DRAWINGS:
WORK THIS DRAWING WITH BY102, BY501, YS506 THRU YS508,
AND YS528
M
.7
5'
20.38'
7'-0" DIA DRILLED SHAFT (TYP)
31.75'
9'-0" DIA DRILLED SHAFT (TYP)
.5
0'
7.13' 13.25'
2.
12823081
6'-0" DIA DRILLED SHAFT (TYP)
N13 .0
0'
18.34'
COLUMN NUMBER
ROW DESIGNATION
DEMONSTRATION SHAFT
WITH BDSLT (NOTE 2)
APPROXIMATE EXTENTS
OF ROCK AT BASE OF
EXCAVATION
APPROXIMATE EXTENTS
OF P-310 BLASTING OPTION
ROCK EXCAVATION
LEGEND:
A
NOTES:
1. ONLY PERMANENT DRILLED SHAFTS ARE SHOWN IN THE
LAYOUT BELOW, ANY LEVELING SHAFTS USED FOR
PRECAST FLOAT-IN MONOLITH PLACEMENT TO BE
DESIGNED AND LOCATION DETERMINED BY THE
CONTRACTOR.
2. PERFORM BDSLT ON IDENTIFIED DEMONSTRATION SHAFTS
IN ACCORDANCE WITH SPECIFICATION SECTION 31 63 26.01.
DEMONSTRATION SHAFTS SHALL BE INSTALLED PRIOR TO
INSTALLATION OF OTHER DRY DOCK SHAFTS. TEST SHAFTS
SHALL BE TESTED TO CONFIRM THE DESIGN UPLIFT
CAPACITY OF 2500 KIPS. MAXIMUM TESTING LOAD SHALL BE
1.33 TIMES THE DESIGN UPLIFT CAPACITY OR 3325 KIPS.
3. SEE BE101 AND BE103 FOR BASIS OF ROCK EXTENTS
SHOWN HERE. 1
AM
EN
D M
EN
T
/1
8/
VM
G
Us
-p p fs s0
1\ sh ar ed
_p ro je ct s\
4\
.0
_s ha re d_ bi m
\d w g\
EX
C A
V A
TIO
N
D
RA
W
IN
G S\
BY
1.
dw g, B
Y1
, 1 2/
/2
:4
7:
P M
FE
W X
W X
W X
W X
W X
W X
W X
(T Y
P
99' - 0"
PS301
C2
PS301
C3
D2
PS401
W X
W18X35
W
W
W
W
W
J K
12" PRECAST
LOAD - BEARING
SHEAR WALLS
(TYP.)
REFER TO PS501 FOR
ADDITIONAL INFORMATION
4" HOUSEKEEPING
PADS TYP.
8" CMU WALLS TO
UNDERSIDE OF DECK
REFER TO
HANDRAIL REFER
TO TYPICAL
DETAILS
OPEN OPEN OPEN
O P
E N
OH DOOR OPENING.
SEE ARCH. FOR
OPENING SIZE AND
LOCATION (TYP.)
1' - 0"
1' - 2" EDGE OF DECK
5' - 8 1/2" 24' - 10"
16' - 1 3/4"
7 1/2" EDGE OF DECK
O F
D E
C K
E D
G E
7 5/8" EDGE OF DECK
PS201
A2
PS201
B3
ROOF ACCESS LADDER
REFER TO TYPICAL DETAILS
18' - 8 3/4" 6' - 7 5/8"
PS401
B2 17' - 3"
3' - 9 1/4" 19' - 0 5/8"
W X
W
21' - 0"
W
0"
22' - 9 3/4"3' - 1 1/4"
W18X35
/8
/8
/4
/8
97' - 0"
/C2 PS504
MECH. UNIT HUNG BELOW
REFER TO MECH. DWGS
WT. = 500#
3' - 8 1/2"
PS201
A4
1' - 10" +/-
ELEC. UNIT ON PAD
REFER TO ELEC. DWGS
WT. = 30,000#
ELEC. UNIT ON PAD
REFER TO ELEC. DWGS
WT. = 30,000#
PS201
C3
(2) ELEC. UNITS ON PAD
REFER TO ELEC. DWGS
WT. = 2,500# EACH1 1/4" x 3/16" W-7-4 SS GRATING WITH
L1-1/2x1-1/2x1/4" WELDED ANGLE FRAME.
FRAME TO HAVE A CLEAR OPENING OF 20" x
30" AND 1/2" DIA. HEADED STUDS WITHIN 6" OF
EACH CORNER. COORDINATE LOCATION WITH
MECH. DWGS. (TYP. 2 LOCS.)
NOTES:
1. DENOTES 6" CONCRETE SLAB ON 1 1/2", 18 GA. COMPOSITE GALVANIZED METAL DECK SPAN WITH 6x6-W2.9xW2.9 WWF
2. GROUND LEVEL = ELEV. 12'-0"
3. T.O. CONCRETE SLAB = ELEV. 24'-8"
4. T.O.S. ELEVATION = ELEV. 24'-2" (TYP. U.N.O.)
5. W10 = W10X12 (TYP. U.N.O.)
6. BEAMS EQUALLY SPACED UNLESS NOTED OTHERWISE IN PLAN.
J K
PS201
B3
PS201
A4
A5
PS503
W8X10 W8X10
PUMP RAIL SUPPORTS
WITH INTERMEDIATE GUIDE
BAR. SEE DETAIL A5/PS503
UNDER SLAB HOIST BEAM
FOR DRAINAGE PUMPS.
T.O.S. ELEV. = 8'-11 1/4" +/-
SEE SECTION FOR
SUPPORT INFO AND PARTIAL
GROUND FLOOR LEVEL PLAN
FOR CONFIGURATION
PS401
C2
SEE NOTE 4
STEEL FLOOR HATCH
REFER TO YS104
C3
PS501
6" CONCRETE HOUSKEEPING
PAD. REFER TO SIMILAR
DETAIL /C2 PS503
STEEL HATCH
REFER TO YS103
PS402
B5
12" THICK PRECAST
CONC. PANELS
97' - 0"
PS201
C3
REFER TO FOR PARTIAL
PLAN OF LOWER STAIR ENCLOSURE
/C2 PS401
PS301
B5
PS301
B5
PS401
C4
/C3 PS502
(4) REMOVABLE PLATES
1/2" DIAMOND PL
W/ REINF. ANGLES,
SEE PS402
NOTES:
1. INDICATES 1/2" THICK S.S. DIAMOND PLATE (REMOVABLE BY HOIST)
2. COORDINATE REQUIRED HOIST CHAIN LENGTHS WITH RESPECTIVE TRADE DRAWINGS.
3. GROUND LEVEL T.O.C. = ELEV. 12'-0"
4. SEE SHEET YS104 FOR SIZE AND LOCATION OF ADDITIONAL GROUND FLOOR OPENINGS.
J
8' - 8"
2' - 6" R
7' - 6"
2' - 9"
20' - 0"
/8
22' - 9 5/8" 9' - 9" +/-
2' - 0"
4' - 0" 4' - 0" 4' - 0" 4' - 0"
HOUSEKEEPING
PAD FOR MECH.
REFER TO TYP.
DETAILS
3' - 0"
4' - 0"
1' - 0"
EQ
EQ
33' - 9 1/2"
2' - 9"
6" CONCRETE
HOUSKEEPING PAD.
REFER TO SIMILAR
DETAIL /C2 PS503
KEY PLAN
K
IT
T E
R Y
M
A
IN
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
CHECK GRAPHIC SCALE BEFORE USING
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
GRAPHIC SCALE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
C A
P
IT
A L I
M P
R O
V E
M E
N T
C O
R E
N A
V A
L S
T A
T
IO
N N
O R
F O
L K
V
IR
G
IN
IA
P -3
M U
L T
I- M
IS
S
IO
N
D R
Y D
O C
K
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C L A S S
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
C
U se rs
P u b lic
D o c u m e n ts
L o c a l_ R e v it F i le s\ D
R Y
D S
W
TR
-1
-A lu c a s.
o liv e rJ K
K A
E .r v t
:2 :2
A
M
P U
M P
S T
A T
IO
N
E
Q U
IP
M
E N
T P
L A
T F
O R
M F
R A
M
IN
G P
L A
N
PS101
ST LO MJS
12823415
452 1056
PLAN NORTH
SCALE: 1/8" = 1'-0"
EQUIPMENT PLATFORM
FRAMING PLAN
4' 0' 4' 8' 12' 16'
1/8" = 1'-0"
PLAN NORTH
SCALE: 1/8" = 1'-0"
GROUND LEVEL FLOOR PLAN
PLAN NORTH
SCALE: 1/8" = 1'-0"
PARTIAL GROUND LEVEL FLOOR
PLAN
A m e n d m e n t
-1
-2
V
M G
CMU PARTITION WALL TO
UNDERSIDE OF DECK
SEE ARCH. DRAWINGS
FOR LOCATIONS.
NOTES:
STEEL DECK
SEE PLAN
L4x4x1/4 x 2'-0" LONG
CENTERED AND WELDED TO
BOTTOM BEAM FLANGE.
EACH SIDE.
STEEL BEAM
SEE PLAN
1. PROVIDE 1" MINIMUM GAP BETWEEN MASONRY WALL AND STRUCTURE ALL AROUND. FILL GAP WITH FIRE-SAFING AS SPECIFIED.
2. REINFORCE ALL MASONRY PARTITON WALLS PER PARTITON WALL REINFORCING SCHEDULE UNLESS NOTED OTHERWISE ON PLANS OR
DETAILS.
3. PARTITON WALL BRACING MAY BE ELIMINATED ONLY WHERE INTERSECTING PARTITION WALLS ARE A MAXIMUM OF 10 FEET APART. ALL
WALLS NOT MEETING THIS CRITERIA SHALL BE BRACED.
4. REFER TO ARCHITECTURAL DRAWINGS FOR TOP OF WALL BRACING ON ALL MASONRY WALLS THAT DO NOT EXTEND TO UNDERSIDE OF
FLOOR OR ROOF STRUCTURE.
5. INTENT IS FOR BOND BEAM TO BE PLACE AT AN ELEVATION SO IT MAY BE CONTINOUS THROUGHOUT, TYP.
M
IN
T
Y P
CMU PARTITION WALL TO
UNDERSIDE OF DECK
SEE ARCH. DRAWINGS FOR
LOCATIONS.
STEEL DECK
SEE PLAN
M
IN
T
Y P
. STEEL BEAM
OR TRUSS
SEE PLAN
BOND BEAM
REINFORCED
WITH (2) #5 CONT.
CUT CMU AT
ANGLE TO
CONFORM TO
ROOF SLOPE
WHERE OCCURS
3/16
TYP.
L2x2x1/4 AT 5'-0" O.C.
- ALTERNATE
L3x3x1/4 AT 5'-0" O.C.
CONT. L4x4x1/4 EVERY OTHER FRAME
3/16
BOND BEAM
REINFORCED
WITH (2) #5 CONT.
FOUNDATION
DOWELS TO
MATCH VERTICALS-TYP.
(3) #5 VERT. BARS 8'-0"<OPNG<12'-0"
(2) #5 VERT. BARS 4'-0"<OPNG<8'-0"
REINFORCE
CELLS WITH
(1) #5 VERT. BAR
0'-0"<OPNG<4'-0"
NOTES:
1. FULLY GROUT ALL REINFORCED CELLS -TYPICAL.
2. MATCH VERTICAL REINFORCING SIZE AND QUANTITY WHERE
BARS LARGER THAN #5 ARE SPECIFIED ON PLANS AND
DETAILS.
WALL OPENING: SEE PLAN
NOTES:
1. FULLY GROUT ALL REINFORCED CELLS -TYPICAL.
2. MATCH VERTICAL REINFORCING SIZE AND QUANTITY WHERE
BARS LARGER THAN #5 ARE SPECIFIED ON PLANS AND DETAILS.
3. DETAIL APPLIES AT BOTH INSIDE AND OUTSIDE CORNERS.
REINFORCE CELLS WITH (1) #5 BAR
CONTINUOUS. FOUNDATION DOWELS
TO MATCH VERTICALS
EPOXY GROUTED W/
9" EMB. MIN. - TYP.
ALL REINFORCED CELLS
SHALL BE FULLY GROUTED-TYP.
STEEL BEAM
SEE PLAN
PARTIAL WALL SECTION PARTIAL WALL SECTION AT WALL OPENING
MASONRY WALL.
GROUT SOLID
AS INDICATED
MASONRY WALL.
GROUT SOLID TO
FOUNDATION LEVEL
NOTES:
U.N.O.
TYP.
(2) HEADED STUDS
3/4" NON-SHRINK GROUT
PARTIAL BEAM BEARING WALL ELEVATION
MASON IN POCKET
AFTER BEAM ERECTIONANGLE WALL
ANCHORS
SEE DETAIL
BEARING
PLATE
6"x8"x1/2"
B. PLATE
BEAM: SEE PLAN
BEAM: SEE PLAN
MASONRY
WALL
5"
3/167 1/2"6"
U.N.O.
USE L 2 1/2 x 2 1/2 x 1/4
WHEN WALL
WIDTH IS 8"
ANGLE WALL ANCHORS
WELD OR BOLT L4x4x3/8 x 3" LG.
LONG TYPICAL TOP & BOTTOM,
BOTH SIDES
U
N D
E R
O
V E
R
3' - 9 1/2" +/-
NOTE:
TYP. EACH WAY
AT CORNER
M
IN
0' - 0 1/2" GAP MAX NO GAP TYP.
EQ
EQ
3/8" DIA S.S. EXP.
ANCHOR, MIN. 3" EMB. TYP.
L2-1/2X2-1/2X3/16 x 4"
LONG @ 32" MAX O.C., TYP
NOTE:
1. COORDINATE DETAIL WITH UNREINFORCED CMU SPANNING TO DECK IN CENTER WALL
MAX. UNREINFORCED HEIGHT = 15'-3"
BOND BEAM LINTEL SCHEDULE
WALL
THICKNESS
(NON-LOADBEARING MASONRY PARTITION WALLS ONLY)
UP TO 4'-0"
8" BEARING EACH END
4'-0" TO 8'-0"
8" BEARING EACH END
8"
8" HIGH BOND BEAM
W/ (2) #5 BARS
8" HIGH BOND BEAM
W/ (2) #5 BARS
NOTES:
1. LINTELS NOT SHOWN ON STRUCTURAL PLANS
2. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATION.
3. FOR SPECIAL CONDITIONS SEE ARCHITECTURAL SCHEDULES OR SECTIONS.
K
IT
T E
R Y
M
A
IN
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
C A
P
IT
A L I
M P
R O
V E
M E
N T
C O
R E
N A
V A
L S
T A
T
IO
N N
O R
F O
L K
V
IR
G
IN
IA
P -3
M U
L T
I- M
IS
S
IO
N
D R
Y D
O C
K
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C L A S S
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
C
U se rs
P u b lic
D o c u m e n ts
L o c a l_ R e v it F i le s\ D
R Y
D S
W
TR
-1
-A lu c a s.
o liv e rJ K
K A
E .r v t
:3
:1
P
M
P U
M P
S T
A T
IO
N
T
Y P
IC
A
L D
E T
A
IL
S
PS504
ST LO MJS
12823426
463 1056
SCALE: N.T.S. C2
TYPICAL INTERIOR NON-BEARING
CMU PARTITION WALL TO
UNDERSIDE OF METAL DECK
BRACING DETAIL
SCALE: N.T.S. C4
TYPICAL MASONRY DETAIL AT JAMBS
AND OPENINGS
SCALE: N.T.S. C5
TYPICAL MASONRY REINFORCING
DETAIL AT CORNER
SCALE: N.T.S. A5
TYPICAL BEAM BEARING ON
MASONRY WALL DETAILS
SCALE: 1 1/2" = 1'-0" B4
TYPICAL CMU WALL BRACING
DETAIL, UNDERSIDE OF CONCRETE
SLAB
SCALE: N.T.S. B5
TYPICAL LINTEL SCHEDULE
A m e n d m e n t
-1
-2
V
M
C D
E
3' - 1 1/8" 11' - 7 1/4"
/2
/4
SEE DETAIL
FOR BASE PLATE
/A3 US400
SEE DETAIL
FOR BASE PLATE
/A4 US400
T.O.C. FIN. FLR.
ELEV. = 12'-0"
HSS6X6X3/8
TYP. (4) LOCATIONS
MAX. TYP.
8' - 0" O.C.
CONCRETE WALL MOUNTED PIPE SUPPORT
REFER TO DETAILS ON US512
T.O.C. ELEV. = 9.70'
C X
.7
S T
R
IN
G E
R
C X
.7
S T
R
IN
G E
R
C8X11.5
US400
B5
GUARD RAIL TYP.
STAIRS UP
US400
B5
6" EQUIPMENT PAD.
COORDINATE
LOCATION WITH MEP
DRAWINGS. REFER
TO DETAIL
US200
C3
8' - 10 1/8"
/A2 US501
D2
US513
23' - 0" 15' - 0"
PIPING TO BE SUPPORTED,
REFER TO MEP DWGS. TYP.
C8X11.5
C8X11.5
3' - 0"
/4
C.6 C
C12X20.7
C X
.7
C X
.5
4' - 9 7/8"9 3/8"
T.O.C. FIN. FLR.
ELEV. = 12' - 0"
HSS3X3X5/16 W/
1/2" BASE PL.
AND (2) 3/4" DIA.
EXP. ANCHORS
T.O.C. ELEV. = 9.70'
US400
B5
C12X20.7
INDICATES SPAN OF GRATING
L4x4x5/16 W/ 1/2" DIA.
EXP. ANCHORS @
3'-0" O.C.
C D E
C12X20.7
C12X20.7
C12X20.7
C12X20.7 C12X20.7 STRINGER
C12X20.7 STRINGER
C X
.5
C X
.5
H S
S
X X
/8
C X
.5
C X
.5
H S
S
X X
/8
C X
.5
L4X 4X5/1
BR
A C E B
R A C E
A2
US400
US400
B5
L4X 4X5/16
B4
US400
INTERMEDIATE LANDING
T.O.S. ELEV. = 22' - 9"
T.O.S. ELEV.
= 24' - 10"
L3X3X1/4 BRACE TYP.
23' - 0" 15' - 0"
3' - 1 1/8" 11' - 7 1/4"
EQ EQ
(+4")
(+4")
2' - 0" TYP.
16' - 6"
DENOTES 1 1/2"X3/16" 19-W-4
GALVANIZED SERRATED GRATING
C.6
HSS COLUMN
SEE PLAN
HSS SEE PLAN
1/4" CAP PL. TYP.
BRACING, SEE PLAN
(TYP.)
1/4 3
TYP.
STRINGERS,
SEE PLAN (TYP.)
1/4 6
BEAM
SEE PLAN
1/4
GUARDRAILS TO BE
WELDED TO TOP
FLANGE OF STRINGERS
(TYP.)
SEE PLAN
PROVIDE 5/16" SHEAR
TAB FOR WELDED BRACE
CONNECTION TYP.
CLR
3' - 0"
GALV STRINGER
SEE PLAN
CONCRETE SLAB
3/8" GALV END PL.
WELD AND GRIND
FLUSH (TYP.)
GALV L3x3x1/4 x 6" LONG
W/ (2) 3/4" DIA.
GALV EXP. BOLTS
COORD.
REQUIRMENTS W/
ARCH. DWGS. TYP.
/2
1" 1"
HSS COLUMN SEE PLAN
3/4" THICK GALV.
BASE PL. W/ (4)
1/2" DIA. EXP.
BOLTS W/ 3 1/4"
MIN. EMBEDMENT
1/4
TYP.
EDGE OF CONCRETE
MIN. 3/4" NON-SHRINK GROUT
US400
HSS COLUMN SEE PLAN
3/4" THICK GALV.
BASE PL. W/ (4)
1/2" DIA. EXP.
BOLTS W/ 3 1/4"
MIN. EMBEDMENT
1 1/4"
7 1/4"
/4 " 1
1/4
TYP.
EDGE OF CONCRETE
MIN. 3/4" NON-SHRINK GROUT
US400
SECOND FLOOR
EL 25.00
C
C12 STRINGER
SEE PLAN
C12 SEE PLAN
C8 SEE PLAN
SERRATED GRATING TREAD, TYP.
5/16" SHEAR TAB W/ (2)
3/4" DIA. BOLTS IN
SHORT SLOTTED
HORIZ. HOLES TYP.
HSS COL.
K
IT
T E
R Y
M
A
IN
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
C A
P
IT
A L I
M P
R O
V E
M E
N T
C O
R E
N A
V A
L S
T A
T
IO
N N
O R
F O
L K
V
IR
G
IN
IA
P -3
M U
L T
I- M
IS
S
IO
N
D R
Y D
O C
K
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C L A S S
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
C
U se rs
P u b lic
D o c u m e n ts
L o c a l_ R e v it F i le s\ D
R Y
D S
W
TR
-1
-A lu c a s.
o liv e rJ K
K A
E .r v t
:2 :2
A
M
U T
IL
IT
Y E
N C
L O
S U
R E
P
L A
T F
O R
M P
L A
N S
A N
D D
E T
A
IL
S
US400
ST LO MJS
12823552
589 1056
SCALE: 1/4" = 1'-0" US101 C2
PARTIAL PLAN AT EXTERIOR
PLATFORM
SCALE: 1/4" = 1'-0" US101 C5
PARTIAL PLAN AT EXTERIOR STAIR
SCALE: 1/4" = 1'-0" US102 B3
PARTIAL PLAN AT EXTERIOR STAIR
4' 0' 4' 8'
1/4" = 1'-0"SCALE: 1/2" = 1'-0" US400 A2
SECTION AT WALKWAY
SCALE: 3/4" = 1'-0" US400 B5
GROUND LEVEL CONNECTION AT
STAIR STRINGER
SCALE: 1 1/2" = 1'-0" A3
COLUMN BASE PLATE DETAIL
SCALE: 1 1/2" = 1'-0" A4
COLUMN BASE PLATE DETAIL
NOTES:
1. ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED
2. STAIR LANDING AND STEPS SHALL BE SERRATED GRATING
3. T.O.S. AT INTERMEDIATE LANDING ELEVATION = 22' - 7 1/2" (TYP. U.N.O.)
NOTE:
1. ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED
2. SEE A3/US401, B3/US501 AND A5/US401 FOR CHANNEL CONNECTIONS
NOTE:
1. ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED
2. STAIR LANDING AND STEPS SHALL BE SERRATED GALVANIZED GRATING TYP.
3. SEE A3/US401, B3/US401, AND A5/US401 FOR CHANNEL CONNECTIONS
SCALE: 3/4" = 1'-0" US400 B4
SECTION AT INTERMEDIATE STAIR
A m e n d m e n t
-1
-2
V
M G
1. CONCRETE CONSTRUCTION AND DETAILING SHALL CONFORM TO THE LATEST EDITION OF ACI 318 OR
ACI 350, AS APPLICABLE, AND ACI 301.
2. CONCRETE MIX DESIGN AND STRENGTH SHALL BE PER THE FOLLOWING TABLE:
CONCRETE:
* WITHIN THE CENTER WALL PRECAST MONOLITHS, NON-MARINE STRUCTURAL CONCRETE SHALL BE
USED AS INFILL WITHIN THE FOLLOWING LIMITS:
MONOLITH B1: BETWEEN ELEVATIONS -31.50 AND -16.50;
MONOLITHS B2-B5: BETWEEN EL. -31.50 AND EL. -5.28;
MONOLITH B6: BETWEEN EL. -27.00 AND EL. -5.28;
MONOLITHS B7 - B9: NON-MARINE STRUCTURAL CONCRETE SHALL NOT BE USED.
WITHIN THE CLOSURE PLACEMENTS BETWEEN CENTER WALL MONOLITHS, ONLY MARINE CONCRETE
SHALL BE USED.
3. EXPOSED CONCRETE EDGES SHALL HAVE A 3/4" CHAMFER OR THE GEOMETRY OF THE EXISTING
ADJACENT CORNERS, UNLESS OTHERWISE NOTED.
4. CONCRETE PLACED IN-THE-DRY SHALL BE MOIST CURED FOR A PERIOD OF 7-DAYS. CURING
SHALL BEGIN IMMEDIATELY AFTER FINISHING CONCRETE PLACEMENT. FOLLOWING THE 7-DAY
MOIST CURE, APPLY AN APPROVED CONCRETE CURING COMPOUND FOR AN ADDITIONAL 14 DAYS.
TOTAL CURING PERIOD SHALL BE 21 DAYS. CONCRETE CAN BE PLACED OVER OR AGAINST
PREVIOUSLY PLACED IN-THE-DRY CONCRETE AT ANY TIME DURING THE INTIAL CURING PERIOD.
5. REVIEW DRAWINGS FROM OTHER DISCIPLINES AND COORDINATE OPENINGS AND EMBEDDED
ITEMS SUCH AS SLEEVES, ANCHORS, INSERTS, CONDUITS, ETC. THAT WILL BE INCORPORATED
INTO THE CONCRETE WORK.
6. THE FABRICATOR IS FULLY RESPONSIBLE FOR THE DESIGN OF THE PRECAST CONCRETE LIFTING DEVICES AND METHODS WHICH SHALL BE IN ACCORDANCE WITH ACI, AISC AND AWS STANDARDS.
7. THE USE OF POWDER-ACTUATED TOOLS ON CONCRETE MEMBERS WILL NOT BE PERMITTED.
8. CONSTRUCTION JOINTS OTHER THAN THOSE SHOWN ON THE DRAWINGS SHALL BE SHOWN ON
THE CONTRACTOR'S CONCRETE LIFT DRAWINGS FOR APPROVAL. CONSTRUCTION JOINTS SHALL
NOT BE PROVIDED WHERE THE STRENGTH OF THE STRUCTURAL MEMBER IS IMPAIRED.
9. CONSTRUCTION JOINTS SHALL BE CLEANED OF SURFACE LAITANCE, INFERIOR CONCRETE,
EXPOSED LOOSE AGGREGATE, CURING COMPOUND AND OTHER FOREIGN MATERIALS BEFORE
PLACING FRESH CONCRETE AGAINST THE SURFACE OF THE JOINT. FOR CONCRETE PLACED IN-
THE-DRY, CONSTRUCTION JOINTS SHALL BE FLUSHED WITH FRESH WATER AND ALLOWED TO
DRY TO A SURFACE DRY CONDITION PRIOR TO PLACING CONCRETE.
10. FINISHED CONCRETE SURFACES ON DECK SHALL POSITIVELY DRAIN TO DRAIN LOCATIONS
WITHOUT PONDING. DEFICIENT AREAS WILL BE REJECTED. REWORK SHALL INCLUDE SAW
CUTTING AND MINIMUM REPLACEMENT OF TOP 3” OF CONCRETE.
11. CONCRETE PLACEMENT PLAN SHALL CLEARLY OUTLINE ANTICIPATED LIFT PLACEMENT FOR EACH
PLACEMENT LOCATION. PROVIDE CALCULATIONS, SIGNED AND STAMPED BY A LICENSED
ENGINEER, INDICATING FORMWORK IS DESIGNED FOR ANTICIPATED LIFT HEIGHT.
12. THIS PROJECT REQUIRES A SPECIALIZED MIX DESIGN, BATCHING AND PLACEMENT TECHNIQUES, TEMPERATURE INSTRUMENTATION, MONITORING AND CONCRETE TEMPERATURE CONTROLS.
13. CONCRETE TEMPERATURES SHALL BE CONTROLLED TO MEET THE REQUIREMENTS IN
SPECIFICATION 03 31 29, PARAGRAPH 1.8.7.
LOCATION / ELEMENT
14. CLOSURE PLACEMENTS SHOULD BE COMPLETED WHEN TEMPERATURES DUE TO HEAT OF HYDRATION OF
ADJACENT CONCRETE SECTIONS HAVE COMPLETELY DISSIPATED.
15. SURFACE PREPARATION SHALL BE CONDUCTED IN STRICT ACCORDANCE WITH THE SPECIFICATIONS.
CONCRETE SURFACES SHALL BE ROUGHENED TO A FULL AMPLITUDE OF 0.25 INCH.
16. CONCRETE ELEVATIONS ARE IN FEET, USING NAVD88 DATUM.
17. CONCRETE DIMENSIONS ARE IN FEET AND INCHES.
18. PROVIDE TOOLED EDGES FOR CONSTRUCTION, CONTRACTION AND EXPANSION JOINTS ON SURFACES
WHERE FLOAT OR STEEL TROWEL FINISH IS REQUIRED.
19. CONCRETE SURFACES EXPOSED TO THE FLOW OF WATER MUST BE SMOOTH AND FREE FROM SPALLS, HONEYCOMBS AND/OR POCKETS.
20. WATERSTOPS SHALL BE TYPE A AND CONTINUOUS, UNLESS OTHERWISE NOTED ON THE DRAWINGS.
WATERSTOP JOINTS AT SPLICES AND CORNERS SHALL BE BONDED. A CONTINUOUS TYPE A WATERSTOP SHALL BE PROVIDED IN EACH VERTICAL CONSTRUCTION JOINT BELOW EL 12.0, UNLESS OTHERWISE NOTED ON THE DRAWINGS. TWO CONTINUOUS TYPE C OR E WATERSTOPS SHALL BE PROVIDED IN EACH EXPANSION
JOINT AND CONTRACTION JOINT AS SHOWN ON THE DRAWINGS.
21. PROVIDE V-GROOVE JOINTS AS DETAILED ON DRAWING YS502 AT CONTRACTION JOINTS, CONSTRUCTION
JOINTS AND CONTROL JOINTS PERMANENTLY EXPOSED TO VIEW.
22. FLOORS AND SLABS SHALL HAVE A U4 FINISH AND GUTTER INVERTS SHALL HAVE A U3 FINISH, UNLESS
OTHERWISE NOTED ON THE DRAWINGS.
23. FOR CONCRETE PLACED IN-THE-DRY, SAMPLING OF FRESH CONCRETE SHALL BE PERFORMED AT THE POINT OF PLACEMENT. IF THE CONCRETE AT THE POINT OF PLACEMENT DOES NOT HAVE THE REQUIRED SLUMP AND TEMPERATURE, THE CONCRETE WILL BE REJECTED AT NO ADDITIONAL COST TO THE CONTRACTING OFFICER. RE-TEMPERING OF THE CONCRETE WITH WATER TO ACHIEVE THE REQUIRED SLUMP WILL NOT BE PERMITTED. ADDITION OF WATER-REDUCING ADMIXTURE FOR RE-MIXING CONCRETE AT THE POINT OF
PLACEMENT WILL BE PERMITTED ONLY UPON APPROVAL OF THE CONTRACTING OFFICER.
24. ADDITIONAL CONCRETE CYLINDERS WILL BE REQUIRED FOR ALL DRY DOCK FLOOR, WALL, CURB AND ENTRANCE STRUCTURE CONCRETE PLACEMENTS FOR FUTURE RADCON TESTING. SAMPLE CONTAINERS WILL BE PROVIDED BY THE GOVERNMENT. THE QUANTITY OF SAMPLES FOR RADCON TESTING WILL NOT
EXCEED 10 SAMPLES PER CONCRETE PLACEMENT.
25. CONCRETE WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE CONCRETE TOLERANCES IN THE CONTRACT SPECIFICATIONS, PCI MNL-135, ACI 117 AND THE FOLLOWING TOLERANCES FOR THE INDIVIDUAL CONCRETE ELEMENTS AND THE ENTIRE DRY DOCK COMPLEX AS A COHERENT WHOLE. THE FOLLOWING TOLERANCES ARE APPLICABLE TO THE PRIMARY CONTROL SURFACES, INCLUDING THE TOP OF THE DRY DOCK FLOOR TOPPING SLAB, INSIDE FACE OF DRY DOCK WALLS AND TOP FACE OF DRY DOCK WALLS AND
ENTRANCE STRUCTURE:
A. OVERALL PLAN DIMENSIONS OF PRECAST FLOOR MONOLITHS: 1/2-IN
B. HORIZONTAL DIMENSIONS AND LOCATION OF PRECAST STARTER WALLS: 1/4-IN
C. OVERALL PLAN DIMENSIONS OF PRECAST CENTER WALL MONOLITHS: 1/2-IN
D. HORIZONTAL DIMENSIONS AND LOCATION OF EXTERIOR FACES OF PRECAST CENTER WALL: 1/4-IN
E. HORIZONTAL DIMENSIONS AND LOCATION OF OPENINGS IN PRECAST FLOOR MONOLITHS FOR
6-FT AND 9-FT DIA DRILLED SHAFT CONNECTIONS: 1/2-IN
F. HORIZONTAL LOCATION OF VERTICAL REINFORCEMENT IN DRILLED SHAFTS: 1/2-IN
G. HORIZONTAL LOCATION OF PRECAST MONOLITHS AFTER SET-DOWN AND LEVELING: 1-IN
H. TOP ELEVATIONS OF PRECAST MONOLITHS: 1/2-IN
I. TOP ELEVATION OF PRECAST MONOLITHS AFTER SET-DOWN AND LEVELING: 1-IN
J. ELEVATION OF TOPPING SLAB: 1/4-IN
26. ALL STEEL SHAPES, PLATES AND HARDWARE THAT ARE REMOVABLE AND NOT EMBEDDED IN CONCRETE SHALL BE HOT-DIPPED GALVANIZED. ALL EXPOSED STEEL SHAPES, PLATES AND HARDWARE THAT ARE EMBEDDED IN CONCRETE AND NOT REMOVABLE SHALL BE STAINLESS STEEL. ALL STEEL SHAPES, PLATES
AND HARDWARE THAT ARE NOT EXPOSED OR ARE USED FOR TEMPORARY FEATURES DURING
CONSTRUCTION SHALL BE SHOP-PRIMED ONLY.
ADDITIONAL NOTES FOR TREMIE CONCRETE:
MIX DESIGN 28-DAY STRENGTH, PSI
DRILLED SHAFTS MARINE CONCRETE 6,000
DRY DOCK FLOOR SLABS, WALLS* AND
REMOVABLE CONCRETE COVERS
MARINE CONCRETE 6,000
ENTRANCE STRUCTURE MARINE CONCRETE 6,000
CONNECTION BETWEEN CENTER
WALL AND EXISTING PUMPWELL AND
UTILITY ENCLOSURE
MARINE CONCRETE 6,000
CONCRETE BACKFILL NON-MARINE BACKFILL
CONCRETE
3,000
BERTH 1 AND BERTH 11
CONNECTING DECK SLABS MARINE CONCRETE 6,000
SECANT PILES, SUPPORT OF
EXCAVATION
NON-MARINE STRUCTURAL
CONCRETE
6,000
1. TREMIE CONCRETE SHALL MEET THE REQUIREMENTS IN SPECIFICATION SECTION 03 31 29
MARINE CONCRETE AND HAVE A 28-DAY STRENGTH OF 6,000 PSI. CONTRACTOR TO
FOLLOW THE RECOMMENDATIONS IN THE GUIDE TO TREMIE CONCRETE FOR DEEP
FOUNDATIONS BY THE DEEP FOUNDATION INSTITUTE/EUROPEAN FEDERATION OF
FOUNDATION CONTRACTORS.
2. SAMPLING OF FRESH TREMIE CONCRETE SHALL BE PERFORMED AT THE POINT OF
PLACEMENT. IF THE CONCRETE AT THE POINT OF PLACEMENT DOES NOT HAVE THE
REQUIRED SLUMP FLOW, THE CONCRETE WILL BE REJECTED AT NO ADDITIONAL COST TO
THE CONTRACTING OFFICER. RE-TEMPERING OF THE CONCRETE WITH WATER TO ACHIEVE
THE REQUIRED SLUMP FLOW WILL NOT BE PERMITTED. ADDITION OF WATER-REDUCING
ADMIXTURE FOR RE-MIXING CONCRETE AT THE POINT OF PLACEMENT WILL BE PERMITTED
ONLY UPON APPROVAL OF THE CONTRACTING OFFICER.
3. TREMIE CONCRETE SHALL BE PLACED IN A CONTINUOUS OPERATION UNTIL THE
PLACEMENT REACHES THE TOP OF THE PLACEMENT.
4. TREMIE CONCRETE SHALL BE PLACED UNIFORMLY ACROSS THE WIDTH OF THE
PLACEMENT.
5. IF MULTIPLE TREMIE PIPES ARE USED, CONCRETE SHALL BE FED ALTERNATELY INTO
ADJACENT TREMIE PIPES SUCH THAT A 2-FOOT MAXIMUM DIFFERENTIAL IS MAINTAINED
ACROSS THE ENTIRE CONCRETE PLACEMENT AND THAT ALL OF THE TREMIE PIPES REMAIN
ALWAYS IMMERSED AT THE SAME DEPTH BELOW AT LEAST 5-FEET OF FRESH CONCRETE.
6. THE NUMBER OF TREMIE PIPES USED FOR EACH PLACEMENT SHALL BE ADJUSTED TO LIMIT
THE HORIZONTAL DISTANCE OF CONCRETE TRAVEL AND TO ENSURE UNIFORMLY LEVEL
UPWARD FLOW OF CONCRETE (MAINTAIN 2-FOOT MAXIMUM DIFFERENTIAL ACROSS THE
ENTIRE CONCRETE PLACEMENT) AND CONCRETE FLOW AROUND EMBEDMENTS. THE
MAXIMUM HORIZONTAL DISTANCE OF CONCRETE TRAVEL SHALL NOT EXCEED 10 FEET.
7. DRILLED SHAFT CONCRETE PLACEMENT RATE SHALL NOT EXCEED 10-FEET OF CONCRETE
RISE PER MINUTE.
8. UNDER NO CIRCUMSTANCES SHALL THE TREMIE PIPES BE RAISED OR LOWERED TO
CONTROL OR CHANGE THE CONCRETE PLACEMENT RATE.
9. EMPLOY MEANS TO PREVENT WATER FROM GETTING INTO THE TREMIE PIPE PRIOR TO
INITIATION OF CONCRETE PLACEMENT, TO AVOID WATER CONTAMINATION OF THE
CONCRETE.
10. PROVIDE NECESSARY MEASURES TO PREVENT POTENTIAL WASH-OUT OF FRESH
CONCRETE DUE TO HYDRAULIC GRADIENTS.
11. TREMIE CONCRETE SHALL NOT BE VIBRATED.
12. TREMIE CONCRETE PLACEMENT SHALL BE COMPLETED IN SUCH A MANNER AND WITHIN
SUCH TIME THAT THE CONCRETE ABOVE THE BASE OF THE TREMIE PIPE REMAINS
WORKABLE UNTIL CONCRETING IS COMPLETE.
13. THE TREMIE PIPES SHALL BE LOWERED TO THE BOTTOM OF THE PLACEMENT THEN RAISED
4 INCHES ABOVE THE BOTTOM OF THE PLACEMENT PRIOR TO BEGINNING TREMIE
CONCRETE DELIVERY.
14. AFTER CONCRETE PLACEMENT HAS STARTED, THE TREMIE PIPES SHALL ALWAYS REMAIN
IMMERSED BELOW AT LEAST 5-FEET OF FRESH CONCRETE.
15. SINCE THE TOP OF THE TREMIE CONCRETE PLACEMENT MAY NOT BE OF THE SPECIFIED
PROPERTIES AND REQUIRED QUALITY, AT LEAST 36" OF TREMIE CONCRETE SHALL BE
PLACED ABOVE THE TOP OF THE PLACEMENT NEAT LINE SHOWN ON THE DRAWINGS. IF
THE DEPTH OF POOR QUALITY CONCRETE AT THE TOP OF TREMIE CONCRETE PLACEMENTS
CAN BE CONSISTENTLY SHOWN BY THE CONTRACTOR THAT IT IS LESS THAN 36" IN SIMILAR
TRIAL PLACEMENTS USING THE APPROVED TREMIE CONCRETE MIX, THE GOVERNMENT MAY
CONSIDER REDUCING THE REQUIRED DEPTH OF OVERPOURING.
16. PRIOR TO PLACING CONCRETE ON TOP OF A PREVIOUSLY PLACED TREMIE CONCRETE LIFT, REMOVE THE TREMIE CONCRETE PLACED PREVIOUSLY DOWN TO THE NEAT LINE FOR THE
PREVIOUS PLACEMENT SHOWN ON THE DRAWINGS. SHOULD CONCRETE LAITANCE BE
OBSERVED AT THE PREVIOUS PLACEMENT NEAT LINE, REMOVE CONCRETE LAITANCE
EXPOSING CONCRETE MEETING THE SPECIFIED REQUIREMENTS. REMOVAL SHALL BE
COMPLETED USING EQUIPMENT AND METHODS THAT DO NOT DISTURB OR DAMAGE THE
CONCRETE OR REINFORCEMENT TO REMAIN.
17. DEFECTS SHALL BE REMOVED AT NO ADDITIONAL COST AND IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS AND THE METHOD APPROVED BY THE CONTRACTING OFFICER.
SECANT PILES UNDER UTILITY
ENCLOSURE MARINE CONCRETE 6,000
PRECAST MONOLITHS:
1. CONTRACTOR SHALL CONSIDER THE RECOMMENDATIONS OF ACI 357.2R-10, REPORT
ON FLOATING AND FLOAT-IN CONCRETE STRUCTURES IN THE CONTRACTOR'S DESIGN
DETAILS FOR FLOATING IN AND FOR SETTING DOWN OF THE PRECAST MONOLITHS.
KI
TT
ER
Y, M
AI
N E
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
P-
M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C
LA
SS
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
Richard Powers, C980 10/15/20
C
U s er s\ Pu b l ic
\D oc u m en ts \L oc a l_ Re v i t_
Fil es
\D
RY
D S
W T R
-1
5 9
-S 1_ nd y o co _r em ot e.
rv t
/1 8/
2 :
:1
PM
ST
R
U C
TU
R
AL
N
O
TE
S
- S
H
EE
T
O F
Y-002
DAM NJD ZRM
12823194 231 1056
AM
EN
DM
E N T
1 2 /1
8/
VM
G
1. REINFORCING STEEL SHALL CONFORM TO ASTM A615 OR ASTM A706, GRADE 60 UNLESS NOTED
OTHERWISE. GRADE 75 REINFORCING STEEL SHALL CONFORM TO ASTM A615. EPOXY-COATED
REINFORCING STEEL SHALL CONFORM TO ASTM A775.
2. REINFORCING STEEL SHALL BE FULLY SUPPORTED ON APPROVED PLASTIC CHAIRS AND/OR
COATED STEEL. WHERE REINFORCING STEEL IS IN CONTACT WITH FORMS, SUPPORTS SHALL BE
PLASTIC OR STAINLESS STEEL.
3. HOOKS SHALL BE STANDARD 90 DEGREE HOOKS UNLESS INDICATED OTHERWISE.
4. SPLICING OF REINFORCING STEEL OVER 20 FEET IS PERMITTED. STAGGER SPLICES ONE SPLICE
LENGTH MINIMUM. UNLESS OTHERWISE NOTED, NO MORE THAN 50 PERCENT OF THE
REINFORCING STEEL SHALL BE SPLICED AT EACH LOCATION.
5. BAR DEVELOPMENT AND LAP SPLICE LENGTHS FOR UNCOATED REINFORCING BARS SHALL BE AS
FOLLOWS:
REINFORCING STEEL:
BAR
DESIGNATION
#3 #4 #5 #6 #7 #8 #9 #10 #11 #14 #18
OTHER BAR
"TOP" BAR
"TOP" BAR
OTHER BAR
LENGTHS ARE IN INCHES.
"TOP" BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE CAST DIRECTLY
BELOW THE BARS.
TABLE VALUES ARE BASED ON BAR SPACING OF 6 INCHES AND CONCRETE COVER OF 3 INCHES.
OTHERWISE, THE PROVISIONS OF ACI 318 SHALL BE USED.
6. WELDING OF REINFORCEMENT IS NOT ALLOWED FOR ASTM A615 BARS.
7. WELDING OF REINFORCING, WHEN APPROVED BY THE CONTRACTING OFFICER, FOR THE ASTM
A706 BARS SHALL BE IN ACCORDANCE WITH AWS D1.4.
8. LAP SPLICES SHALL NOT BE USED IN LOCATIONS OF MAXIMUM MOMENTS, UNLESS OTHERWISE
PERMITTED ON THE DRAWINGS. LAP SPLICES SHALL NOT BE PERMITTED IN DRILLED SHAFTS.
9. WHEN BARS OF DIFFERENT SIZE ARE LAP SPLICED IN COMPRESSION, SPLICE LENGTH SHALL BE
THE LARGER OF: DEVELOPMENT LENGTH OF LARGER BAR OR SPLICE LENGTH OF SMALLER BAR.
10. MECHANICAL COUPLERS SHALL BE DESIGNED FOR 125 PERCENT OF YIELD STRENGTH OF
REINFORCING STEEL FY 80 KSI.
11. BAR DEVELOPMENT AND LAP SPLICE LENGTHS FOR EPOXY COATED BARS WITH COVER LESS
THAN 3 TIMES THE BAR DIAMETER OR CLEAR SPACING LESS THAN 6 TIMES THE BAR DIAMETER SHALL BE 1.5 TIMES LONGER THAN THE VALUES IN THE ABOVE TABLE AND 1.2 TIMES LONGER FOR
ALL OTHER EPOXY COATED BARS.
12. PER THE CONTRACTOR'S MEANS AND METHODS, BUNDLED BARS SHALL BE ARRANGED WITHIN
THE BUNDLE TO FACILITATE CONCRETE PLACEMENT AND CONSOLIDATION IN CONGESTED
AREAS.
1. REINFORCEMENT DETAILING AND PLACEMENT SHALL CONFORM TO THE LATEST EDITION OF ACI
318, OR ACI 350, AS APPLICABLE, AND ACI 117 UNLESS OTHERWISE NOTED.
2. SUBMIT DETAILED REINFORCING DRAWINGS INCLUDING BAR AND BENDING SCHEDULES TO THE
CONTRACTING OFFICER FOR REVIEW AND APPROVAL PRIOR TO FABRICATION OF REINFORCING
STEEL.
GENERAL NOTES FOR REINFORCEMENT:
REINFORCEMENT SHALL HAVE A MINIMUM CONCRETE COVER AS FOLLOWS, EXCEPT AS OTHERWISE
NOTED OR SHOWN ON THE DRAWINGS.
CONCRETE COVER FOR REINFORCEMENT:
DRILLED SHAFTS:
BOTTOM OF FOUNDATIONS AND FOOTINGS:
BACKFILLED SURFACES AND SURFACES SUBJECT TO SUBMERGENCE:
#18 BARS AND SMALLER
EXTERIOR BEAMS AND COLUMNS NOT SUBJECT TO SUBMERGENCE:
EXTERIOR WALLS AND SLABS NOT SUBJECT TO SUBMERGENCE:
#11 BARS AND SMALLER
#14 BARS
#18 BARS
INTERIOR BEAMS AND COLUMNS:
INTERIOR WALLS AND SLABS:
#11 BARS AND SMALLER
#14 AND #18 BARS
6" 6"
6" 3"
3" 3 1/2" 4 1/2" 1 1/2"
1 1/2" 2 1/2"
BAR DEVELOPMENT LENGTH LAP SPICE LENGTH
WHERE,
LAP SPLICE NOT PERMITTED
LAP SPLICE NOT PERMITTED
1. MATERIALS NOT SPECIFIED ON THE DRAWINGS SHALL BE IN ACCORDANCE WITH THE
SPECIFICATIONS.
2. WELDED CONSTRUCTION SHALL BE USED.
3. EXPOSED STEEL (NON-STAINLESS) SHALL BE PAINTED OR GALVANIZED IN ACCORDANCE WITH
THE SPECIFICATIONS.
4. STEEL (NON-STAINLESS) SURFACES EMBEDDED IN CONCRETE SHALL NOT BE PAINTED.
5. ALUMINUM SURFACES IN CONTACT WITH STEEL OR CONCRETE SHALL BE PAINTED WITH ONE
COAT OF ZINC CHROMATE PRIMER, UNLESS OTHERWISE RECOMMENDED BY THE ALUMINUM
PRODUCT MANUFACTURER.
6. STEEL PIPE RAILINGS AND LADDERS SHALL BE GALVANIZED AND SHALL CONFORM TO OSHA
STANDARDS. IN ADDITION, RAILINGS SHALL COMPLY TO THE REQUIREMENTS OF THE
AMERICANS WITH DISABILITIES ACT (ADA) LATEST EDITION.
7. GRATINGS AND NON-EMBEDDED FRAMES SHALL BE GALVANIZED AFTER FABRICATION. FRAMES
OR SUPPORTS EMBEDDED IN CONCRETE SHALL BE STAINLESS STEEL. PROVIDE DIELECTRIC
ISOLATION BETWEEN DISSIMILAR METALS, INCLUDING THROUGH THICKNESS OF PARTS.
8. SHEARED EDGES SHALL BE GROUND SMOOTH.
9. WELDS SHALL BE 3/16" CONTINUOUS FILLET WELDS, E70XX ELECTRODE, UNLESS OTHERWISE
SHOWN ON THE DRAWINGS.
10. CORNERS OF FRAMES SHALL BE MITERED AND WELDED IN ACCORDANCE WITH APPROVED
SHOP PRACTICE. GRIND WELDS SMOOTH ON BEARING AND EXPOSED SURFACES.
11. FURNISH EXPANSION ANCHORS AND CONNECTION BOLTS WHERE SUCH ARE REQUIRED.
DIAMETER OF HOLES FOR ANCHORS AND BOLTS SHALL BE 1/16" LARGER THAN DIAMETER OF
ANCHORS/BOLTS INDICATED.
12. ANCHOR BOLTS SHALL CONFORM TO ASTM A193, GRADE B8 CLASS 2 STAINLESS STEEL, UNLESS
OTHERWISE SPECIFIED ON THE DRAWINGS.
13. CONNECTION BOLTS SHALL CONFORM TO ASTM F3125, GRADE A325.
14. STEEL PIPE RAILINGS SHALL CONFORM TO ASTM A53, SCHEDULE 40 AND 80 AS SHOWN ON THE
DRAWINGS.
15. EXPOSED STEEL EMBEDMENTS SHALL BE STAINLESS STEEL.
16. STAINLESS STEEL SHALL MEET THE REQUIREMENTS OF SPECIFICATION SECTION 05 12 00 AND 05 50 13.
17. STEEL COMPONENTS CAPABLE OF CATCHING AND RETAINING WATER MUST HAVE A 1/4" MIN.
DRAIN HOLE AT THE LOWEST POINT.
18. PROVIDE AN OSHA COMPLIANT PERSONAL FALL ARREST SYSTEM ON ALL LADDERS TALLER
THAN 24 FEET.
MISCELLANEOUS METALS:
1. MOORING HARDWARE SHALL BE IN ACCORDANCE WITH SPECIFICATION
SECTION 05 30 00.01 "MOORING HARDWARE".
2. MOORING HARDWARE SHALL HAVE THE FOLLOWING MINIMUM WORKING
CAPACITIES:
A. CLEATS: 20 TONS (0 TO 180 DEGREES HORIZONTAL & 0 TO 45
DEGREES VERTICAL)
3. FITTINGS SHALL BE CAST STEEL ASTM A-27, GRADE 65-35, HOT-DIPPED
GALVANIZED, AND COATED IN ACCORDANCE WITH THE SPECIFICATIONS.
4. BOLT POCKETS SHALL BE FILLED WITH POLYURETHANE SEALANT.
5. GROUT FOR ANNULUS AND GROUT BED SHALL BE NON-SHRINK, NON-METALLIC
HIGH PERFORMANCE CEMENTITIOUS GROUT HAVING A MINIMUM 28 DAY
COMPRESSIVE STRENGTH OF 7,500 PSI. GROUT SHALL CONFORM TO ASTM
C-1107, GRADE C.
6. ANCHOR BOLTS SHALL CONFORM TO ASTM A193, GR. B8. NUTS SHALL
CONFORM TO A194, GR. 8. WASHERS SHALL BE 304 STAINLESS STEEL
CONFORMING TO ASTM A276. DIELECTRIC ISOLATION WASHERS/SLEEVES
SHALL BE USED BETWEEN DISSIMILAR METALS.
7. ANCHOR BOLT TESTING SHALL BE COMPLETED BY AN INDEPENDENT TESTING
AGENCY. SUBMIT EXPERIENCE AND QUALIFICATIONS FOR THE ANCHOR BOLT
TESTING PERSONNEL. ONE ANCHOR BOLT FROM EACH MOORING FITTING
BATCH SHALL BE TESTED IN TENSION UTILIZING THE INCREMENTAL LOAD
APPLICATION TEST IN ACCORDANCE WITH ASTM E488 TENSION TESTING.
PROOF LOAD SHALL BE MAINTAINED FOR A MINIMUM OF 10 MINUTES.
8. TESTED ANCHOR BOLTS SHALL BE TESTED TO 90% OF THE ANCHOR BOLT YIELD
STRENGTH. ANCHOR BOLTS THAT FAIL TESTING SHALL BE REMOVED AND
REINSTALLED AT NO COST TO THE CONTRACTING OFFICER. FAILURE IS
CONSIDERED ONE OF THE FOLLOWING:
A. FAILURE TO REACH PROOF LOAD OF 90% YIELD STRENGTH.
B. A PERMANENT SET REMAINS AFTER LOAD IS RELEASED.
C. DISPLACEMENT GREATER THAN ELASTIC STRETCH OF THE
MATERIAL UNDER REQUIRED LOAD.
9. AFTER AN ANCHOR BOLT TEST FAILURE THE NEXT 5 ANCHOR BOLTS OR MORE
SHALL BE TESTED. SUBMIT TESTING REPORTS TO THE CONTRACTING OFFICER
WITHIN 24 HOURS OF TEST COMPLETION.
MOORING HARDWARE:
FIBERGLASS REINFORCED PLASTIC (FRP) GRATING:
1. FRP GRATING SHALL MEET THE FOLLOWING REQUIREMENTS:
A. ONE-PIECE MOLDED CONSTRUCTION COMPOSED OF CONTINUOUS ROVING FIBERLASS REINFORCEMENT AND ISOPHTHALIC
POLYESTER RESIN WITH A 65% TO 35% RESIN TO GLASS RATIO;
B. MINIMUM FLEXURAL STRENGTH OF 30,000 PSI PER ASTM D790;
C. MINIMUM SHEAR STRENGTH OF 4,500 PSI PER ASTM D2344;
D. MINIMUM TENSILE STRENGTH OF 30,000 PSI PER ASTM D638;
E. MINIMUM LOAD CAPACITY OF 600 PSF UNIFORM LOAD AND 2,000 PLF CONCENTRATED LINE LOAD;
F. FLAME SPREAD RATING OF 25 OR LESS PER ASTM E84 TUNNEL TEST AND AN EXTENT OF BURN RATE OF LESS THAN OR EQUAL
TO 10 MILLIMETERS PER ASTM D635 WHEN TESTED FOR A BURN TIME OF LESS THAN 30 SECONDS;
G. UV, CORROSION AND IMPACT RESISTANT; NON-CONDUCTIVE; AND FREE OF INTERLAMINAR VOIDS, POROSITY, DRY SPOTS, CRACKS, FIBER ORIENTATION IRREGULARITIES, UNREINFORCED AREAS AND EXPOSED GLASS FIBERS;
H. ALL CUT OR SANDED SURFACES ARE SEALED WITH RESIN PRIOR TO INSTALLATION;
I. GRATING BAR INTERSECTIONS ARE PROVIDED WITH A MINIMUM FILLET RADIUS OF 1/16 INCH;
J. TOP LAYER OF REINFORCEMENT IS NO MORE THAN 1/8 INCH BELOW THE TOP SURFACE OF THE GRATING;
K. TOPS AND BOTTOMS OF BEARING AND CROSS BARS ARE IN THE SAME PLANE; AND
L. GRATING BARS ARE PROVIDED WITH A NON-SLIP, GRIT SURFACE.
2. GRATING PANELS SHALL BE PROVIDED OF UNIFORM LENGTH, SIZED TO MINIMIZE THE NUMBER OF PANELS, WITH A MAXIMUM PANEL
WEIGHT OF 50 POUNDS.
3. GRATING PANELS SHALL BE FASTENED TO SS THREADED STUDS WELDED TO SS SUPPORT ANGLES WITH A MINIMUM OF (4) TYPE M, STAINLESS STEEL, HOLD-DOWN CLIPS PER PANEL.
4. GRATING PANELS SHALL BE SPACED WITH A 3/8 INCH MAXIMUM GAP BETWEEN ADJACENT PANELS.
5. GRATING PANELS SHALL BE PROVIDED IN A GRAY COLOR.
6. CONTRACTOR SHALL SUBMIT PRODUCT DATA AND TEST REPORTS SHOWING THE FRP GRATING MEETS THE ABOVE REQUIREMENTS.
7. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING THE FRP GRATING PANEL DETAILS, LAYOUT, FASTENERS, COLOR, NON-
SLIP SURFACE, ETC.
8. CONTRACTOR SHALL HANDLE ALL MATERIALS TO PREVENT ABRASION, CRACKING, CHIPPING, TWISTING, OTHER DEFORMATIONS AND
OTHER TYPES OF DAMAGE.
9. CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND TAKE ALL FIELD MEASUREMENTS NECESSARY FOR PROPER SIZING AND FIT- UP BEFORE FABRICATION. INCLUDE ALL MATERIALS AND PARTS NECESSARY TO COMPLETE EACH ITEM, EVEN THOUGH SUCH WORK IS NOT DEFINITELY SHOWN OR SPECIFIED. PERFORM CUTTING, DRILLING, AND FITTING REQUIRED FOR INSTALLING GRATINGS IN THE SHOP TO THE GREATEST EXTENT POSSIBLE. SET GRATING UNITS AND SUPPORT ANGLES ACCURATELY IN LOCATION, ALIGNMENT, AND ELEVATION; MEASURED FROM ESTABLISHED LINES AND LEVELS; AND FREE OF RACK AND WOBBLE. COMPLY WITH RECOMMENDATIONS OF BAR GRATING STANDARDS, INCLUDING INSTALLATION CLEARANCES AND STANDARD ANCHORING DETAILS.
KI
TT
ER
Y, M
AI
N E
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
P-
M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C
LA
SS
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
Richard Powers, C980 10/15/20
C
U s er s\ Pu b l ic
\D oc u m en ts \L oc a l_ Re v i t_
Fil es
\D
RY
D S
W T R
-1
5 9
-S 1_ nd y o co _r em ot e.
rv t
/1 7/
: 3
0:
A M
ST
R
U C
TU
R
AL
N
O
TE
S
- S
H
EE
T
O F
Y-003
DAM NJD ZRM
12823195 232 1056
AM
EN
DM
E N T
1 2 /1
8/
VM
FE
A3
YS322
A3
YS327
A3
YS328
ST
A
5+
.3
CENTER WALLCL
5 + 00 4 + 50 4 + 00
6'-0" DIA OPENING
FOR PUMP SHAFT (YS514,TYP)
CL
DD1N ENTRANCE
STRUCTURE
M
AT
C H
LI
N
E (S
EE
Y
S1
PRECAST
CONCRETE
MONOLITH B9
D D
1N E
N
TR
AN
C
E
ST
R U
C
TU
R E
EXISTING DD1W ENTRANCE
STRUCTURE (P-310)
49' - 0"
FLOOR
ACCESS DOOR
CJ AND WS
TYPE A (TYP)
FIXED LADDER
(YS519)
A3
YS323
D D
1W E
N
TR
AN
C
E
ST
R U
C
TU
R E
(P -3
UP
8' - 0" 1' - 6"
5' - 9" 1' - 6" 20' - 0" 1' - 6"
13' - 10 3/8" 10' - 6" 10' - 6" 10' - 6" 10' - 4 5/8" 7 5/8"
FIXED LADDER
(YS519)
FIXED LADDER
(YS519)
YS522
A2
YS522
B4
YS519
A3
UT-100.1
BOLTED COVER
PLATE SUBJECT TO
RIVER PRESSURE
(YS514)
1'-4" DIA
OPENING
FOR PUMP
SHAFT (TYP)
CL
YS514
B2
YS519
A4
EL -3.00
12%
SLOPE
PRECAST
CONCRETE
MONOLITH B8
3' - 0" 4' - 0" 49' - 0" 6' - 0" 49' - 0" 6' - 0"
1'
6"
7'
0"
1'
6" 1'
6"
1'
0"
1'
6" 5'
2"
2'
4" 7'
6"
3'
0"
8"
" 3'
0"
25' - 6 3/8"
2" DEEP X
4" WIDE,
GUTTER
(TYP)
HANDRAIL
(YS518, TYP)
HANDRAIL
(YS518, TYP)
PROVIDE ANTI-SKID
SAFETY COATING
ON RAMP (TYP)
5'
0" 5'
0"
31' - 0"
2' - 8 1/2"
3'
0"
9'
0"
7'
1/
4"
/4
3'
0"
WATER CHAMBER BELOW
3'
6" 3'
6"
6'
0"
27' - 3"
6' - 11 5/8" 23' - 4 3/4"
6'
3/
4" 7'
0"
CJ AND WS
TYPE A (TYP)
CJ AND WS TYPE A,
ALL AROUND (TYP)
EXCEL BRACING WALL
ANCHORS @ 8'-0" OC AT EL 9.57
AND EL -15.43 (YS512) 8' - 0"
8' - 0"
EXCEL BRACING WALL
ANCHORS @ 8'-0" OC AT EL 9.57
AND EL -15.43 (YS512)
CJ AND WS TYPE A,
CONTINUOUS ALL
AROUND
(T
YP
EQ
(T Y P
EQ
CJ
9' - 6" 4' - 6" 4' - 9" 4' - 6"
2' - 6"
6' - 3"
LEGEND:
FLOAT-IN PRECAST CONCRETE
MONOLITHS
EXISTING
CAST-IN-PLACE CONCRETE
TREMIE CONCRETE
KEY PLAN
KI
TT
ER
Y, M
AI
N E
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
CHECK GRAPHIC SCALE BEFORE USING
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
GRAPHIC SCALE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
P-
M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C
LA
SS
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
Richard Powers, C980 10/15/20
C
U s er s\ Pu b l ic
\D oc u m en ts \L oc a l_ Re v i t_
Fil es
\D
RY
D S
W T R
-1
5 9
-S 1_ nd y o co _r em ot e.
rv t
/1 7/
: 5
3:
P M
C
EN
TE
R
W
AL
L
- C
O N
C R
ET
E
- P
LA
N S
SH
EE
T
O F
YS107
DAM NJD ZRM
12823199 267 1056
PLAN NORTH
SCALE: 1/8" = 1'-0"
PLAN EL -3.00
8' 0 8' 16' 1/8" = 1'-0"
NOTES:
1. FOR PARTITION TYPE AND DOOR TYPE DETAILS SEE
ARCHITECTURE DRAWING UA601 AND PA601. FOR
STRUCTURAL DETAILS, SEE PS503, PS504, US508 AND
US513.
AM
EN
DM
E N T
1 2 /1
8/
VM
A3
YS324
A3
YS329
A2
YS331
M
AT
C H
LI
N
E (S
EE
Y
S1
M
AT
C H
LI
N
E (S
EE
Y
S1
COLUMN
3'-0" x 3'-0"
(TYP)
CENTER
WALL
CL
3 + 504 + 00 3 + 00
PRECAST
CONCRETE
MONOLITH B7
49' - 0"49' - 0"
CONCRETE COVER
(4 EQUAL PANELS,
YS511)
A3
YS330
ELECTRICAL
UTILITY TUNNEL
MECHANICAL
UTILITY TUNNEL
FIXED
LADDER
(YS519, TYP)
ST
A
2+
.3
ST
A
3+
.8
STEEL FLOOR HATCH
& FIXED LADDER
BELOW (YS519)
M08
M08M08M08
M08 M08
12% SLOPE
EL -5.28
6' - 0" 49' - 0" 6' - 0" 49' - 0" 6' - 0"
PRECAST
CONCRETE
MONOLITH B6
18' - 4" 18' - 4" 18' - 4" 18' - 4" 18' - 4" 18' - 4" 18' - 4"25' - 6 3/8"
3'
0"
3'
0"
2'
0"
2'
0"
9'
6"
9'
6"
PRECAST
CONCRETE
MONOLITH B8
PRECAST
CONCRETE
MONOLITH B5
EL -5.28
19' - 0" 8' - 9" 8' - 9" 8' - 9" 8' - 9"
6" 6"
2" DEEP X 4" WIDE,
GUTTER (TYP)
ELECTRICAL MANHOLE
AC-523
(7'-8" DEEP)
HANDRAIL
(YS518, TYP)
HANDRAIL
(YS518, TYP)
5' - 10" 8' - 0"
6'
0" 2'
0"
8"
5'
0"
6"
6'
0"
6"
FLOOR ACCESS
DOOR (YS519)
2' - 10" 3' - 0"
CJ AND WS
TYPE A (TYP)
CJ AND WS
TYPE A (TYP)
EXCEL BRACING WALL
ANCHORS @ 8'-0" OC AT EL 9.57
AND EL -15.43 (YS512)
EXCEL BRACING WALL
ANCHORS @ 8'-0" OC AT EL 9.57
AND EL -15.43 (YS512) CJ AND TYPE A,
CONTINUOUS ALL
AROUND (TYP)
CJ AND WS TYPE A,
CONTINUOUS ALL
AROUND (TYP)
(T
YP
EQ
(T Y P
EQ
(T Y P
EQ
(T Y P
EQ
3' - 0"
3'
0" 3'
6"
3'
0" 1
LEGEND:
FLOAT-IN PRECAST CONCRETE
MONOLITHS
EXISTING
CAST-IN-PLACE CONCRETE
TREMIE CONCRETE
KEY PLAN
KI
TT
ER
Y, M
AI
N E
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
CHECK GRAPHIC SCALE BEFORE USING
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
GRAPHIC SCALE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
P-
M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C
LA
SS
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
Richard Powers, C980 10/15/20
C
U s er s\ Pu b l ic
\D oc u m en ts \L oc a l_ Re v i t_
Fil es
\D
RY
D S
W T R
-1
5 9
-S 1_ nd y o co _r em ot e.
rv t
/1 7/
: 5
7:
P M
C
EN
TE
R
W
AL
L
- C
O N
C R
ET
E
- P
LA
N S
SH
EE
T
O F
YS108
DAM NJD ZRM
12823200 268 1056
PLAN NORTH
SCALE: 1/8" = 1'-0"
PLAN EL -5.28
8' 0 8' 16' 1/8" = 1'-0"
NOTES:
1. FOR PARTITION TYPE AND DOOR TYPE DETAILS SEE
ARCHITECTURE DRAWING UA601 AND PA601. FOR
STRUCTURAL DETAILS, SEE PS503, PS504, US508 AND
US513.
AM
EN
DM
E N T
1 1 /1
6/
VM
G
AM
EN
DM
E N T
1 2 /1
8/
A2
YS332
A3
YS325
COLUMN
3'-0" x 3'-0" (TYP)
CENTER WALLCL
M
AT
C H
LI
N
E (S
EE
Y
S1
M
AT
C H
LI
N
E (S
EE
Y
S1
2 + 50 2 + 00 1 + 50
49' - 0"
PRECAST
CONCRETE
MONOLITH B5
6' - 0"
18' - 4"18' - 4"
(TYP)
ELECTRICAL
UTILITY TUNNEL
MECHANICAL
UTILITY TUNNEL
FIXED LADDER
(YS519, TYP)
DD1N SW STAIR
SLOPE
SLOPE
ELECTRICAL
MANHOLE AC-522
(7'-8" DEEP)
18' - 4" 18' - 4" 18' - 4" 18' - 4" 18' - 4" 18' - 4" 18' - 4"
EL -5.28
EL -5.28
6' - 0" 49' - 0" 6' - 0" 49' - 0"
2'
0" 5'
6"
5'
6" 2'
0"
M08 M08
2" DEEP X 4" WIDE,
GUTTER (TYP)
7' - 6" 8' - 0"
2'
0" 6'
0"
FLOOR ACCESS
DOOR (YS519)
PRECAST
CONCRETE
MONOLITH B4
PRECAST
CONCRETE
MONOLITH B3
CJ AND WS
TYPE A (TYP)
CJ AND WS
TYPE A (TYP)
CJ AND WS TYPE A,
CONTINUOUS ALL
AROUND (TYP)
EXCEL BRACING
WALL ANCHORS @
8'-0" OC AT EL 9.57
AND EL -15.43 (YS512)
EXCEL BRACING WALL
ANCHORS @ 8'-0" OC AT EL 9.57
AND EL -15.43 (YS512)
(T
YP
EQ
(T Y P
EQ
DD1W NW STAIR
3'
6" 3'
0"
3' - 0"
LEGEND:
FLOAT-IN PRECAST CONCRETE
MONOLITHS
EXISTING
CAST-IN-PLACE CONCRETE
TREMIE CONCRETE
KEY PLAN
KI
TT
ER
Y, M
AI
N E
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
CHECK GRAPHIC SCALE BEFORE USING
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
GRAPHIC SCALE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
P-
M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C
LA
SS
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
Richard Powers, C980 10/15/20
C
U s er s\ Pu b l ic
\D oc u m en ts \L oc a l_ Re v i t_
Fil es
\D
RY
D S
W T R
-1
5 9
-S 1_ nd y o co _r em ot e.
rv t
/1 7/
: 0
5:
P M
C
EN
TE
R
W
AL
L
- C
O N
C R
ET
E
- P
LA
N S
SH
EE
T
O F
YS109
DAM NJD ZRM
12823201 269 1056
8' 0 8' 16' 1/8" = 1'-0"
PLAN NORTH
SCALE: 1/8" = 1'-0"
PLAN EL -5.28
NOTES:
1. FOR PARTITION TYPE AND DOOR TYPE DETAILS SEE
ARCHITECTURE DRAWING UA601 AND PA601. FOR
STRUCTURAL DETAILS, SEE PS503, PS504, US508 AND
US513.
AM
EN
DM
E N T
1 1 /1
6/
VM
G
AM
EN
DM
E N T
1 2 /1
8/
A2
YS333
A3
YS326
CENTER WALLCL
ST
A
0+
.0
0 + 00
M
AT
C H
LI
N
E (S
EE
Y
S1
1 + 00
HEAD END WALL
49' - 0"
PRECAST
CONCRETE
MONOLITH B2
A3
YS334
1" EXPANSION JOINT
ELECTRICAL
UTILITY TUNNEL
MECHANICAL
UTILITY TUNNEL
18' - 4" CONNECTING STRUCTURE
TO EXISTING PUMPWELL
FIXED
LADDER
(YS519, TYP)
A3
YS335
DD1N SE STAIR
DN
UP
UP
1/ 8"
/8
M08
M08
M08
ELECTRICAL
MANHOLE
AC-524 (7'-8"
DEEP)
FIXED
LADDER
(YS519, TYP)
EL -5.28
EL -5.28
EL -8.28
EL -8.28
18' - 4" 18' - 4" 18' - 4" 18' - 4" 18' - 4" 16' - 3"
2'
0" 5'
6"
5'
6" 2'
0"
5'
8"
5'
4"
6'
5" 4'
7"
6' - 0" 49' - 0" 6' - 0" 40' - 4" 18' - 8"
PRECAST
CONCRETE
MONOLITH B1
5' - 7 1/2" 8' - 1 1/4" 22' - 3 1/4"
7'
1/
2" 7'
6"
EL -15.95
EL -22.96
EL -2.62
2" DEEP X 4" WIDE,
GUTTER (TYP)
M08
PROVIDE ANTI-SKID
SAFETY COATING
ON RAMP (TYP)
1/ 8"
21' - 7 3/4"
18' - 7 1
/4"
4' - 2" 5' - 2"
2'
0" 6'
0"
FLOOR ACCESS
DOOR (YS519)
1" EXPANSION JOINT
EXCEL BRACING
WALL ANCHORS @
8'-0" OC AT EL 9.57
AND EL -15.43 (YS512)
EXCEL BRACING WALL
ANCHORS @ 8'-0" OC AT EL 9.57
AND EL -15.43 (YS512)
1" EXPANSION
JOINT BELOW
2'
1/
2" 3'
0"
7'
1/
2"
FILLING CULVERT
GATE SLOT
1" EXPANSION JOINT WITH
EXISTING ENTRANCE STRUCTURE
20' - 8"
CJ AND WS
TYPE A (TYP)
CJ AND WS
TYPE A (TYP)
(T
YP
EQ
(T Y P
EQ
DD1W NE STAIR
CJ (TYP) 3'
6" 3'
0"
3' - 0"
/8
8" 9'
7/ 8"
4' - 6"
2' - 5 3/4"
LEGEND:
FLOAT-IN PRECAST CONCRETE
MONOLITHS
EXISTING
CAST-IN-PLACE CONCRETE
TREMIE CONCRETE
KEY PLAN
KI
TT
ER
Y, M
AI
N E
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
CHECK GRAPHIC SCALE BEFORE USING
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
GRAPHIC SCALE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
P-
M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C
LA
SS
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
Richard Powers, C980 10/15/20
C
U s er s\ Pu b l ic
\D oc u m en ts \L oc a l_ Re v i t_
Fil es
\D
RY
D S
W T R
-1
5 9
-S 1_ nd y o co _r em ot e.
rv t
/1 7/
: 1
6:
P M
C
EN
TE
R
W
AL
L
- C
O N
C R
ET
E
- P
LA
N S
SH
EE
T
O F
YS110
DAM NJD ZRM
12823202 270 1056
8' 0 8' 16' 1/8" = 1'-0"
PLAN NORTH
SCALE: 1/8" = 1'-0"
PLAN EL -5.28
NOTES:
1. FOR PARTITION TYPE AND DOOR TYPE DETAILS SEE
ARCHITECTURE DRAWING UA601 AND PA601. FOR
STRUCTURAL DETAILS, SEE PS503, PS504, US508 AND
US513.
AM
EN
DM
E N T
1 1 /1
6/
VM
G
AM
EN
DM
E N T
1 2 /1
8/
VM
YS336
0 + 00
T/ CURB
EL 13.00
T/ WALL
EL 12.00
CONNECTING
STRUCTURE
TO EXISTING
PUMPWELL
CURB
1' - 0"
UP
CL CENTER
WALL
CJ
2'
9"
NORTH DOCKWALL
4'
3"
1'
0"
SCUPPER
(YS503, TYP)
HEAVY DUTY
FLOOR
ACCESS DOOR
(YS519)
10' - 0"
EL 9.70
WATER LEVEL
MARKER BOARD
(YS505)
EL 9.70
WATER LEVEL
MARKER BOARD
(YS505)
EL -15.95
5' - 8"
C U
R B
1'
0"
1" EXPANSION
JOINT WITH
WS TYPE E
4'
8"
4'
8"
3'
7/
8"
2' - 6"
11' - 11 5
/8"
3' - 5 3/4" 3' - 1"
2' - 6" 21' - 2 3/4"
2'
3'
1"
WINCH AND
CONCRETE PAD
(YS504)
DD1NCL
1" EXPANSION
JOINT
WINCH
CONTROLLER
8' - 9"
/2
FIXED LADDER
(YS519, TYP)
HEAVY DUTY
FLOOR ACCESS
DOOR (YS519)
A3
YS336
0 + 00
CL CENTER
WALL
EL 2.09
NORTH DOCKWELL
FIXED LADDER
(YS519, TYP)
EL -8.28
EL -8.28
M08
UT-100.3
SHIPS LADDER
2' - 0" 6' - 0" 2' - 0"
EL -2.62
EL -5.28
EL -8.28
EL -8.28
EL -3.61
10' - 0"
4' - 0" 3' - 0"
WATER LEVEL
MARKER
BOARD (YS505)
HANDRAIL
(YS523, TYP)
1" EXPANSION
JOINT WITH WS
TYPE E
FIXED LADDER
(YS519, TYP)
SLOPE
/4
5'
0"
/2
1" EXPANSION
JOINT WITH
WS TYPE E
2'
0" 6'
0"
2'
0"
UP
UP
DN
UP
4' - 0" 3' - 1"
DN
EL -18.20
3'-0 x 3'-0"
COLUMN (TYP)
EL -18.20
EL -5.28
GUTTER
EL -8.28
WATER LEVEL
MARKER BOARD
(YS505)
EL -15.95
CJ
FLOOR
ACCESS DOOR
(YS519, SIM)
FLOOR
ACCESS DOOR
(YS519, SIM)
SHIPS LADDER
ELECTRICAL
MANHOLE TC-6
ELECTRICAL
MANHOLE
AC-521
ELECTRICAL
MANHOLE TC-6
3'
0"
WS TYPE E
1" EXPANSION JOINT
WITH WS TYPE C, ALL
AROUND CULVERT
CONNECTIONS
1' - 4 1/2" 3' - 0"
1' - 4 1/2"
2'
1/
4"
3'
0"
/8
6'
5" 2'
3/ 4"
2'
6" 1'
1/
2"
2' - 8 1/4" 2' - 6" 9 3/4"
4' - 6"2
/8
8" 9'
7/ 8"2
A3
YS336
0 + 00
PRECAST
CONCRETE
SLAB A1
CL CENTER
WALL
5'-0" x 6'-0"
DRAINAGE/
DEWATERING
CULVERT
FROM DD1E
T/ TOPPING SLAB
EL -36.43
PRECAST
CONCRETE
MONOLITH B1
6'-0" DIA
DRILLED SHAFT
1" EXPANSION JOINT
WITH WS TYPE E, ALL
AROUND CULVERTCJ
CJ
WATER LEVEL
MARKER BOARD
(YS505)
T/ FLOOR
EL -36.43
NORTH
DOCKWALL
WS TYPE A
(TYP)
LEGEND:
FLOAT-IN PRECAST CONCRETE
MONOLITHS
EXISTING
CAST-IN-PLACE CONCRETE
TREMIE CONCRETE
KI
TT
ER
Y, M
AI
N E
PO
R
TS
M
O U
TH
N
AV
AL
S H
IP
YA
R D
CHECK GRAPHIC SCALE BEFORE USING
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
GRAPHIC SCALE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
C
AP
IT
AL
IM
PR
O
VE
M
EN
T C
O R
E N
AV
AL
S
TA
TI
O
N N
O R
FO
LK
, V
IR
G
IN
IA
P-
M
U
LT
I-M
IS
SI
O
N D
R Y
D O
C K
#1
DRAWFORM REVISION: 07 AUG 2018
UNCLASSIFIED
U N C
LA
SS
IF
IE
D
UNCLASSIFIED
EJA
DSN
NBJ
LBT/LBL
1604959
DES DRW CHK
CONSTR. CONTR. NO.
SCALE: AS SHOWN
Richard Powers, C980 10/15/20
C
U s er s\ Pu b l ic
\D oc u m en ts \L oc a l_ Re v i t_
Fil es
\D
RY
D S
W T R
-1
5 9
-S 1_ nd y o co _r em ot e.
rv t
/1 7/
: 2
0:
P M
D D
1N H
EA
D
E N
D W
AL
L
- C O
N C
R
ET
E
- P
LA
N
S
YS117
DAM NJD ZRM
12823209 277 1056
PLAN NORTH
SCALE: 1/8" = 1'-0"
PLAN EL 12.00
PLAN NORTH
SCALE: 1/8" = 1'-0"
PLAN EL 2.09
PLAN NORTH
SCALE: 1/8" = 1'-0"
PLAN EL -36.43 8' 0 8' 16'
1/8" = 1'-0"
NOTES:
1. THE SCUPPERS WITH INLINE CHECK VALVES AROUND
DD1W AND THE SCUPPERS WITHOUT INLINE CHECK VALVES
AROUND DD1N.
2. FOR PARTITION TYPE AND DOOR TYPE DETAILS SEE
ARCHITECTURE DRAWING UA601 AND PA601. FOR
STRUCTURAL DETAILS, SEE PS503, PS504, US508 AND
US513.
AM
EN
DM
E N T
1 1 /1
6/
VM
G
AM
EN
DM
E N T
1 2 /1
8/
VM
YS340
A3
YS338
CENTER WALLCL
EXISTING PUMPWELL
DD1W EXISTING DD1E
EL -15.95
EL -3.00
EL -8.28
0 + 00
1" EXPANSION
JOINT
A3
YS341
A3
YS342
A3
YS339
SEE UTILITY
ENCLOSURE
DRAWINGS
(TYP)
EL -22.96
DD1N
2' - 0" 6' - 0" 2' - 0"
EL -8.28
HEAD END WALL
3'-0" DIA DRILLED SHAFT
/2
SAWCUT 12' -7 1/2"
OPENING
IN EXISTING WALL
2' - 6"
M08
M08
UT-100.3
UT-100.2
10' - 3" 22' - 4 1/8" 5' - 2 1/8"
10' - 5" 10' - 6" 17' - 8" 13' - 0"
UTILITY ENCLOSURE
SLAB ABOVE
ENCASE EXISTING
ANCHOR IN CONCRETE
WALL (TYP)
M08
M08
M08
STEEL FLOOR
HATCH FOR
MANHOLE BELOW
4'
0"
/8
1' - 6"
3'-0" DIA DRILLED SHAFT
2'-6" DIA DRILLED SHAFT
2'-0" DIA DRILLED SHAFT
3'-0" DIA
DRILLED
SHAFT
2'-6" DIA DRILLED
SHAFT
10' - 6"
10' - 6"
BOTTOM SLAB OF
ELECTRICAL MANHOLE
EL -8.28
EL -8.28
2'
0"
/8
5' - 0"
4' - 9"
14' - 3" 30' - 1 1/4"
NON-MARINE
BACKFILL CONCRETE
ABOVE SECANT PILES
EL -8.28
TYPE C WS (TYP)
/8
3/ 8"
5'
1/
8" 8'
6"
/2
(T Y P
1'
6"
1'
6"
1'
3/
8"
3'
4" 5'
8"
5' - 0" 8' - 8" 2' - 0"
2'
7/
8"
B5
YS340
1" EXPANSION
JOINT
DRAINAGE/FILLING CULVERT
SLUICE GATE SLOT
1" EXPANSION JOINT WITH DOUBLE WS, TYPE C, ALL
AROUND CULVERT AND TUNNEL CONNECTIONS,
REMOVE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .