Amendment 14 - Nitrogren Overall Plan.pdf

PDF 1 MB Posted

Attached to
P-381 MULTI-MISSION DRY DOCK #1, PORTSMOUTH NAVAL SHIPYARD (PNSY), KITTERY MAINE
Solicitation number
N4008520R0021
Issued by

About this file

This document contains plans for modifications and additions to Dry Dock #1 at Portsmouth Naval Shipyard in Kittery, Maine. The project involves constructing two new dry dock bays, labeled DD1N and DD1W, within the existing superflood basin to support maintenance and overhaul of Virginia Class submarines. New construction will include concrete floors, walls and a center wall separating the bays, new pump well systems, a pump station building, portal crane rails, mooring hardware, mechanical and electrical utilities, utility tunnels and all necessary appurtenances. Modifications will also be made to the existing basin closure wall and Berths 1 and 11. The existing DD1 pump well will be connected to the new system and interior modified. The Department of the Navy, Naval Facilities Engineering Command is the agency managing this design-bid-build project.

View the file

Other files

File Type Posted
AMENDMENT 0015.pdf PDF
Amendment 14 - 25 00 00.00 22.pdf PDF
Amendment 14 - Electrical dwgs.pdf PDF
AMENDMENT 0014.pdf PDF
Amendment 14 - Mechanical Dwgs.pdf PDF
Amendment 14 - Electrical One Line.pdf PDF
Amendment 14 - Fire Protection One Line.pdf PDF
Amendment 14 - Henderson Point Dwgs.pdf PDF
Amendment 14 - Panelboards.pdf PDF
Amendment 14 - 32 31 13.53.pdf PDF
Amendment 14 - Raychem RHW 2-hour fire-rated power cable.pdf PDF
Amendment 14 - Civil Site Dwgs.pdf PDF
Amendment 14 - 25 00 00.00 22_ASW_Control.pdf PDF
Amendment 14 - General Dwgs.pdf PDF
Amendment 13 - Hendersen Pt Site Dwgs.pdf PDF
Amendment 13 - General Dwgs.pdf PDF
Amendment 13 - Electrical Dwgs.pdf PDF
Amendment 13 - Mechanical Dwgs.pdf PDF
Amendment 13 - Structural Dwgs.pdf PDF
Amendment 13 - Geotech dwgs.pdf PDF
AMENDMENT 0013.pdf PDF
Amendment 0013 - Price Proposal Form (rev).pdf PDF
Amendment 13 - Civil Dwgs.pdf PDF
Amendment 13 - 40 95 00 App B - IO List.pdf PDF
Amendment 13 - Process dwgs.pdf PDF
AMENDMENT 0012.pdf PDF
Amendment 12 - Structural Drawings.pdf PDF
Amendment 12 - General Drawings.pdf PDF
Amendment 12 - 40 95 00 App B - IO List.pdf PDF
Amendment 12 - LightFixt_BOD_1_5_2021.pdf PDF
Amendment 12 - Pump Station and Utility Enclosure.pdf PDF
Amendment 12 - Electrical drawings.pdf PDF
Amendment 0011.pdf PDF
Amendment 10 - General dwgs.pdf PDF
Amendment 10 - Drydock 1 existing pumpwell valve arrangements drawings.pdf PDF
Amendment 10 - Geotech- Structural dwgs.pdf PDF
Amendment 10 - Architectural dwgs.pdf PDF
Amendment 10 - Electrical dwgs.pdf PDF
Amendment 10 - Mechanical.dwgs.pdf PDF
AMENDMENT 0010.pdf PDF
Amendment 10 - Civil dwgs.pdf PDF
Amendment 0009.pdf PDF
Amendment 8 - Structural.pdf PDF
Amendment 8 -mechanical.pdf PDF
01 50 00.00 22.pdf PDF
Amendment 8 - Geotech.pdf PDF
23 81 23.00 20.pdf PDF
Amendment 8 -Civil.pdf PDF
Amendment 8 -Structural Bld.pdf PDF
21 13 13.00 20.pdf PDF
Show 40 more

Latest 50 of 123 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F

F

F F

F

F

F F

D

D

EXISTING

3/4" NITROGEN

IN TUNNEL

3/4" NITROGEN

IN TUNNEL

EXISTING

3/4" NITROGEN

IN TUNNEL

EXISTING

1/2" NITROGEN

DIRECT BURIED

EXISTING 3/4" NITROGEN

SERVICE CONNECTION

AT BERTH 2

EXISTING

NITROGEN STORAGE

3/4" NITROGEN

IN TUNNEL

3/4" NITROGEN

IN TUNNEL

3/4" NITROGEN

IN TUNNEL

EXISTING NITROGEN

STORAGE 900 GALLON

LIQUID N2 TANKS

DD1E EXISTING

TUNNEL OUTLINE

CENTER WALL

TUNNEL OUTLINE

DD1W EXISTING

TUNNEL OUTLINE

BERTH 2 EXISTING

TUNNEL OUTLINE

EXISTING PUMP WELL

BELOW GRADE

UTILITY

ENCLOSURE

NITROGEN BULK

TANKS

DD1N N2

UTILITY SERVICE

CONNECTION 2

DD1N N2 UTILITY

SERVICE CONNECTION 1

DD1N N2

UTILITY SERVICE

CONNECTION 4

DD1N N2 UTILITY

SERVICE CONNECTION 3

DD1N N2 UTILITY

SERVICE CONNECTION 5

DD1N N2

UTILITY SERVICE

CONNECTION 6

DD1W N2

UTILITY SERVICE

CONNECTION 2

DD1W N2

UTILITY SERVICE

CONNECTION 1

DD1W N2

UTILITY SERVICE

CONNECTION 4

DD1W N2

UTILITY SERVICE

CONNECTION 3

DD1W N2

UTILITY SERVICE

CONNECTION 5

DD1W N2

UTILITY SERVICE

CONNECTION 6

EXISTING DD1E

SERVICE

GALLERY 1

EXISTING DD1E

SERVICE

GALLERY 5

EXISTING DD1E N2

UTILITY SERVICE

CONNECTION 3

K

IT

T E

R Y

M

A

IN

E P

O R

T S

M O

U T

H N

A V

A L S

H

IP

Y A

R D

CHECK GRAPHIC SCALE BEFORE USING

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

SHEET

NAVFAC DRAWING NO.

OF

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

GRAPHIC SCALE

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

C A

P

IT

A L

I M

P R

O V

E M

E N

T C

O R

E N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

V

IR

G

IN

IA

P -3

M

U L T

I- M

IS

S

IO

N

D R

Y D

O C

K

DRAWFORM REVISION: 07 AUG 2018

UNCLASSIFIED

U N C L A S S

IF

IE

D

UNCLASSIFIED

LBT/LBL

NBJ

EJA

DSN

SCALE: AS SHOWN

CHKDRWDES

CONSTR. CONTR. NO.

EPROJECT NO.: 1604959

C

U se rs

P u b lic

D o c u m e n ts

L o c a l_ R e v it

F ile s\ D

R Y

D S

W

TR

-1

-M te n v id

.r v t

/1

/2

:3

:0

P

M

N

IT

R O

G E

N O

V E

R A

L L P

L A

N

MN100

TJE DFA VAK

12823758

795 1029

PLAN NORTH

SCALE: 1" = 60'-0"

NITROGEN OVERALL PLAN

60' 0 60' 120'

1" = 60'

A

M E

N D

M E

N T

/1 /2

V

M G

Sheets
MH701 - FIRE PROTECTION SCHEMATIC
MN100 - NITROGEN OVERALL PLAN

File details come from the government source that posted it. Updated .