This solicitation is for the completion of the Joint Air Defense Operations Center permanent facility as the second phase of construction. The project will construct a two-story facility including a concrete slab-on-grade foundation with spread footings, structural steel frame, concrete masonry unit shear walls, and roofing system. Additional requirements include pavements, all utilities, site improvements, passive force protection measures, security fencing, and diverse communication routing. The facility must meet Intelligence Community Directive/Intelligence Community Standard 705 for Controlled Space and Joint Base Anacostia Bolling architectural design standards. It will be designed as permanent construction according to the Department of Defense Unified Facilities Criteria 1-200-01 and comply with Department of Defense antiterrorism/force protection requirements per Unified Facility Criteria 4-010-01. The solicitation was issued by the Naval Facilities Engineering Command on behalf of the Department of the Navy.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TRAINING
VTC
STORAGE
241B
TRAINING
COMM
241A
EQUIPMENT/COMM
ROOM
251B
CONTROLLED
SPACE VTC
251A
CONTROLLED
SPACE
RADIO/
ANTENNA
ROOM
OFFICE 3P
OFFICE 4P
OFFICE 2P
OFFICE 2P
OPEN
OFFICE
OFFICE
281OFFICE
OFFICE 3P
OFFICE 3P
PLANNING
ROOM
VTC
OFFICE
OFFICE 2P
PRINTER
OFFICE 3P
OFFICE 3P
OFFICE 2P
COMM
CHAPLAIN
OFFICE
OFFICE
BN CDR
BN XO
CSM
OFFICE
OFFICE
OFFICE
288BREAK
ROOM
MEN
294A
WOMEN
294B
MOTHER'S
RM
JAN
COMM
STAIR "C"
200C
ADA/DMO
TRAINING
SUITE
PLUMBING
CLOSET
290C
COR.
COR.
COR.
COR.
COR.
COR.
CLOSET
I-402 A2
I-202
D3
I-402 A1
I-201
I-202
B2
B3
A1
I-201
A1
275A
VEST
251C
VEST
290A
VEST
290B
I-201 C2 I-205
D2
I-205
D1
I-201
C1 C3
B1
I-202D1 I-202
I-202D4
D2
I-202
I-202
I-202
C1
C2
C3
I-202
C4
I-202
C4SIM
I-202
D2
SIM
I-202C2
SIM
I-202 B1I-202B1
SIM
I-202B1
SIM
I-202B1
SIM
I-202 B1I-202 B1
SIM
I-202 B1I-202 B1
I-202
B2
I-202
B3
I-202
A1
SIM
I-202A2
I-202
A4
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERW ISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL W ALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERW ISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
N
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
4:
P M
I-1
-S E
C O
N D
F
LO
O R
IN
TE
R
IO
R E
LE
VA
TI
O
N P
LA
N
I-109 302153
W
AS
H
IN
GT
O N D
.C
13134622
1673850
SAK SAK AB
SE
C O N D
FL
O O R
IN
TE
RI
O R
EL
EV
AT
IO
N P
LA
N
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
1/8" = 1'-0"A1 SECOND FLOOR INTERIOR ELEVATION PLAN
GENERAL NOTES
GRAPHIC SCALE(S)
KEY PLAN
GRAPHIC SCALE 1/8" = 1'-0"
24'4' 8' 16'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N40080-21-R-3502
EQEQ
A07
HOLD SPACE FOR
WALL MOUNTED
MONITOR
3'
- 6
CT-3
CT-5
CT-4
CT-8
OPEN
BEYOND
3" 4'
- 6
CT-6
CT-8
CT-3
CT-5
CT-4
PT-4
3" 4'
- 6
PT-4
CT-3
CT-6
CT-4
CT-8
CT-5
PT-4
PT-4
1 1
6" 4'
- 6
3"
PT-4
CT-4
CT-6
CT-3
CT-8
CT-5
4'
- 6
3"
PT-4
CT-4
CT-6
CT-3
CT-8
CT-5
OPEN BEYOND PT-4
3" 4'
- 6
CT-4
CT-6
CT-3
CT-8
CT-5
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERW ISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL W ALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERW ISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.3'
- 6
EQEQ
A07
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
3'
- 6
7' - 0" 6' - 0"
TY
P.
6'
- 0
TYP.
1' - 6"
A01
A07 A07
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
6" 4'
- 6
3"
CT-3
CT-4
CT-5
CT-6
CT-8
PT-4 OPEN
BEYOND
CT-3
CT-4
CT-5
CT-8
CT-3
CT-4
CT-5
CT-8
CT-3
CT-4
CT-5
CT-8
3" 4'
- 6
6"
CT-3
CT-4
CT-5
CT-6
CT-8
PT-4
CT-3
CT-4
CT-5
CT-8
4'
- 0
3"
CT-6
PT-4
CT-3
CT-4
CT-5
CT-6
CT-8
4'
- 0
3"
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
5:
P M
I-2
-I N
TE
R
IO
R
E
LE
V A
TI
O
N S
I-200 302154
W
AS
H
IN
GT
O N D
.C
13134623
1673850
SAK SAK AB
IN
TE
RI
O R
EL
EV
AT
IO
N S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3/8" = 1'-0"D1 171B FIELD ENGINEERING OPS & PLANNING - SOUTH
3/8" = 1'-0"C1 192, 193, 194 SHOW ER - TYP.
3/8" = 1'-0"C2 192, 193, 194 SHOW ER - TYP
3/8" = 1'-0"C3 192, 193, 194 SHOW ER/TOILET - TYP
3/8" = 1'-0"C4 192, 193, 194 SHOW ER/TOILET - TYP
3/8" = 1'-0"B1A 192, 193, 194 TOILET - TYP
3/8" = 1'-0"B1B 192, 193, 194 TOILET - TYP
GENERAL NOTES
GRAPHIC SCALE(S)
KEYED NOTES#
GRAPHIC SCALE 3/8" = 1'-0"
8'2' 4'1'
3/8" = 1'-0"D2 171B FIELD ENGINEERING OPS & PLANNING - NORTH
3/8" = 1'-0"D3 171B FIELD ENGINEERING OPS & PLANNING - EAST
3/8" = 1'-0"B2 195, 196 ACCESSIBLE SHOW ER/TOILET - TYP.
3/8" = 1'-0"B3 195, 196 ACCESSIBLE SHOW ER - TYP.
3/8" = 1'-0"B4 195, 196 ACCESSIBLE SHOW ER - TYP.
3/8" = 1'-0"A1 195, 196 ACCESSIBLE SHOW ER - TYP.
3/8" = 1'-0"A2 195, 196 ACCESSIBLE SHOW ER/TOILET - TYP.
3/8" = 1'-0"A3 195, 196 ACCESSIBLE SHOW ER/TOILET - TYP.
3/8" = 1'-0"A4 195, 196 ACCESSIBLE SHOW ER/TOILET - TYP.
1. PROVIDE (TS1) TRANSITION STRIP AT VERTICAL EXPOSED EDGE OF TILE.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
EQ. 8' - 0" EQ.
A07 A07
4'
- 6
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERW ISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL W ALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERW ISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
EQ EQ
A01
A07
TYP.
1' - 6"
4'
- 6
3'
- 6
6' - 0"
ST02
A07
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
TYP.
1' - 5 7/8"
TY
P.
6'
- 0
5' - 0 1/8" 6' - 0"
ST07 ST07
ST02
A01
1' - 7"
4'
- 0
4'
- 6
3' - 0"
A12 A11
5' - 4"
4'
- 6
A13
8' - 4"
A07
4'
- 6
4'
- 6
A07
A01
TYP.
1' - 6"
TY
P.
6'
- 0
A07 A07
7' - 0" 6' - 6"
A01
4' - 0"
4'
- 6
7' - 0"6' - 6"
3'
- 6
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
A07 A07A07A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
5:
P M
I-2
-I N
TE
R
IO
R
E
LE
V A
TI
O
N S
I-201 302155
W
AS
H
IN
GT
O N D
.C
13134624
1673850
SAK SAK AB
IN
TE
RI
O R
EL
EV
AT
IO
N S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3/8" = 1'-0"D1 197 ARMY DESK DUTY OFFICE - EAST
GENERAL NOTES
GRAPHIC SCALE(S)
KEYED NOTES#
GRAPHIC SCALE 3/8" = 1'-0"
8'2' 4'1'
3/8" = 1'-0"D3 197 ARMY DUTY DESK OFFICE - W EST
3/8" = 1'-0"C1 241 ADA / DMO TRAINING SUITE
3/8" = 1'-0"C2 251 CONTROLLED SPACE - EAST
3/8" = 1'-0"C3 251 CONTROLLED SPACE - SOUTH
3/8" = 1'-0"B1 251 CONTROLLED SPACE - W EST
3/8" = 1'-0"B2 251A CONTROLLED SPACE VTC - NORTH
3/8" = 1'-0"B3 251A CONTROLLED SPACE VTC - SOUTH
3/8" = 1'-0"A1 252 VTC - NORTH
3/8" = 1'-0"1 252 VTC - SOUTH
1. FURNITURE IN GRAY SHOWN FOR REFERENCE ONLY, NOT IN CONTRACT.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERWISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL WALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL WALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERWISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL WALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
3'
EQ EQ
A12
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
A12
A01
3' - 9"
3'
TYP.
1' - 6"
T Y
P
6'
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
4'
EQ.12' - 0"EQ.
ST06 ST06 ST06
ST02
1 1 1
3' - 2"
3'
A13
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
EQ EQ
3'
A12
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
8' - 0"
4'
A07
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
3'
2' - 4"
A13
EQEQ
4'
A12
6' - 3" 5' - 3"
3'
A07
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
HOLD
3' - 3"
3'
3' - 8"
TYP.
1' - 6"
T Y
P
6'
A01
A07
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
3' - 6"
3'
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
TYP.
1' - 6"
T Y
P
6'
A12
A01
EQ.8' - 0"EQ.
A07 A07
TYP.
1' - 6"
T Y
P
6'
4' - 6"
3'
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
A01
A07
EQ.
12' - 0"
EQ.
ST02
ST01 ST01 ST01 ST01 ST01 ST01 4'
ST06 ST06 ST06
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
T H E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2
/2
:1 :1
P
M
I-
IN
T E
R
IO
R E
L E
V A
T
IO
N S
I-202 302156
W
AS
H
IN
G
TO
N
D .C
13134625
1673850
SAK SAK AB
IN
TE
R
IO
R
E
LE
VA
TI
O N S
JO
IN
T B
AS
E
AN
AC
O S
TI
A B O
LL
IN
G
P -5
J A
D O
C P
H A
S E
I I
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
W
A S
H
IN
G T
O N
D .C
W A S H
IN
G
TO
N
D .C
TH
E
N
AV
Y
YA
R D
GENERAL NOTES
GRAPHIC SCALE(S)
KEYED NOTES#
GRAPHIC SCALE 3/8" = 1'-0"
8'2' 4'1'
3/8" = 1'-0" D1
253 OFFICE 2P
3/8" = 1'-0" D2
254 OFFICE
3/8" = 1'-0" D3
256 PRINTER
3/8" = 1'-0" D4
262 OFFICE 3P
3/8" = 1'-0" C2
264 OFFICE 3P
3/8" = 1'-0" C1
263 OFFICE 4P
3/8" = 1'-0" C3
266 OFFICE 2P
3/8" = 1'-0" C4
271 & 273 OFFICE 2P
3/8" = 1'-0" B1
PRIVATE OFFICE TYPICAL
3/8" = 1'-0" B2
276 BN CDR
3/8" = 1'-0" B3
283 OFFICE
3/8" = 1'-0" A1
295 PLANNING ROOM
3/8" = 1'-0" A2
295 PLANNING ROOM - WEST
1. FURNITURE IN GRAY SHOWN FOR REFERENCE ONLY, NOT IN CONTRACT.
3/8" = 1'-0" A4
297A PRINT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
HOLD
EQ. 3' - 0"
HOLD
EQ.
3'
- 0
1'
- 6
1' - 6"
TRASH
1' - 6"
A1 I-504
A2 I-504
A3 I-504
PL-2
QZ-1
PL-1
B1 I-504
A1 I-504
C3 I-504
C2 I-505
C1 I-505
C1 I-506
A1 I-506
PL-2
PL-1
PL-1
QZ-1
CT-7E05
E05
E06
E07
PL-2
2' - 4"
(7) EQ. PANELS
7' - 8"2' - 4"
HOLD
2' - 5 13/16"
3'
- 0
1'
- 6
2'
- 1
0"
E05
E14
15' - 6"
7' - 6" 8' - 0"
2'
- 1
0"
A2 I-504
C2 I-504
4 5 5555 QZ-1
PL-1
4' - 9" 1' - 0"
A1 I-505
A3 I-505
A3 I-505
SIM
PL-1 PL-1
QZ-1
CT-7
2'
- 1
0" 9 1
/2"
8' - 0"
A1 I-505
A3 I-505
A3 I-505
SIM
QZ-1
CT-7
PL-1
9 1 /2"
2'
- 1
0"
8' - 0"
7PL-1
QZ-1
QZ-1
2'
- 1
0" 9 1
/2"
1' - 8" 4 7/8"
A1 I-504
C3 I-505
B1 I-505
C2 I-506
PL-1
SS-1
PL-2
3'
- 0
2'
- 0
2'
- 1
0"
UC FRIDGE
2' - 0"2' - 0"1' - 4 7/8"
E10
(4) EQ. PANELS
5' - 4 7/8"
1. PROVIDE (TS1) TRANSITION STRIP AT VERTICAL EXPOSED EDGE OF TILE.
2. PROVIDE AND INSTALL 1 1/2" DIA GROMMET WITH PLUG WHERE NOTED.
INTENT FOR GROMMET COLOR TO MATCH QUARTZ COUNTERTOP.
3. PROVIDE SILICON SEAL W HERE QUARTZ COUNTER TOP MEETS WALL.
4. DESIGN INTENT FOR COUNTER TOP TO ALIGN W ITH WINDOW SILL. PROVIDE
SILICON SEAL WHERE QUARTZ COUNTER TOP MEETS WALL AND WINDOW
SILLS.
5. PROVIDE SOLID SURFACE (SS-2) W INDOW SILL.
6. PROVIDE SILICON SEAL W HERE SOLID SURFACE BACKSPLASH MEETS
WALL.
7. PROVIDE SILICON SEAL W HERE COUNTERTOP MEETS BACKSPLASH.
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERW ISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL W ALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERW ISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
CT-3
CT-4
CT-5
CT-6
CT-8
PT-4
3" 4'
- 0
CT-6
CT-3
CT-5
CT-4
CT-8
PT-4
3" 4'
- 0
CT-6
CT-3
CT-4
CT-5
CT-8
3" 4'
- 0
6"
PT-4 PT-4
PT-4
PT-4
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
6:
P M
I-2
-I N
TE
R
IO
R
E
LE
V A
TI
O
N S
I-203 302157
W
AS
H
IN
GT
O N D
.C
13134626
1673850
SAK SAK AB
IN
TE
RI
O R
EL
EV
AT
IO
N S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3/8" = 1'-0"C2 288 BREAK ROOM - EAST
3/8" = 1'-0"C1 288 BREAK ROOM - NORTH
3/8" = 1'-0"C3 288 BREAK ROOM - SOUTH
3/8" = 1'-0"B1 288 BREAK ROOM - ISLAND (FRONT)
3/8" = 1'-0"B2 288 BREAK ROOM - ISLAND (REAR)
3/8" = 1'-0"B3 288 BREAK ROOM - ISLAND SECTION
3/8" = 1'-0"B4 296 MOTHER'S RM
GENERAL NOTES
GRAPHIC SCALE(S)
KEYED NOTES#
GRAPHIC SCALE 3/8" = 1'-0"
8'2' 4'1'
3/8" = 1'-0"A1 292 MEN - DIVIDER NORTH
3/8" = 1'-0"A2 292 MEN - URINAL SIDE W ALL
3/8" = 1'-0"A3 292 MEN - EAST
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PT-4
PT-4
CT-3
CT-4
CT-5
CT-6
CT-8
3" 4'
- 0
CT-6
CT-3
CT-4
CT-5
CT-8
PT-4
CT-6
CT-3
CT-5
CT-4
CT-8
PT-4
PL-1
SS-1
PT-4
3" 4'
- 0
C3 I-506
CT-6
CT-3
CT-5
CT-4
CT-8
PT-4
PT-4
PT-4
SS-1
PL-1
6" 4'
- 0
3"
CT-6
CT-3
CT-4
CT-5
CT-8
PT-4
SS-1
PL-1
PT-4
2'
- 1
0"
CT-6
CT-3
CT-4
CT-5
CT-8
PT-4
PT-4
PT-4
TP-1
SS-1
PL-1
6" 4'
- 0
3"
CT-6
CT-3
CT-4
CT-5
CT-8
PT-4
6" 4'
- 0
3"
CT-6
CT-3
CT-4
CT-5
CT-8
PT-4
3" 4'
- 0
5' - 0"PT-4
CT-6
CT-3
CT-4
CT-5
CT-8
4'
- 0
3"
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERW ISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL W ALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERW ISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
PT-4
CT-3
CT-4
CT-5
CT-6
CT-8 6"
4'
- 0
3"
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
6:
P M
I-2
-I N
TE
R
IO
R
E
LE
V A
TI
O
N S
I-204 302158
W
AS
H
IN
GT
O N D
.C
13134627
1673850
SAK SAK AB
IN
TE
RI
O R
EL
EV
AT
IO
N S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3/8" = 1'-0"D3 292 MEN - NORTH
3/8" = 1'-0"C2 292 MEN - TOILET ELEVATION
3/8" = 1'-0"D2 292 MEN - W EST
3/8" = 1'-0"D1 292 MEN - SOUTH
3/8" = 1'-0"C3 294 W OMEN - NORTH
3/8" = 1'-0"B4 294 W OMEN - EAST
3/8" = 1'-0"B1 294 W OMEN - SOUTH
3/8" = 1'-0"B2 294 W OMEN - W EST
3/8" = 1'-0"B3 294 W OMEN - TOILET ELEVATION
GENERAL NOTES
GRAPHIC SCALE(S)
KEYED PLAN#
GRAPHIC SCALE 3/8" = 1'-0"
8'2' 4'1'
3/8" = 1'-0"C1 292 MEN - DIVIDER SOUTH
1. PROVIDE SOLID SURFACE (SS-2) WINDOW SILL.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
A06 - QTY 1
CE
NT
ER
LI
NE
4'
- 0
EQ EQ
A06 - QTY 2
CE
NT
ER
LI
NE
4'
- 0
1' - 2" 8" 1' - 2"
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERW ISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL W ALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERW ISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
3' - 6"
TY
P.
6'
- 0
6' - 6" 3' - 5"
3'
- 6
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
A07 A07
A01
HOLD SPACE
FOR WALL
MOUNTED
MONITOR
3' - 5" 6' - 6"
3'
- 6
A07 A07
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
6:
P M
I-2
-I N
TE
R
IO
R
E
LE
V A
TI
O
N S
I-205 302159
W
AS
H
IN
GT
O N D
.C
13134628
1673850
SAK SAK AB
IN
TE
RI
O R
EL
EV
AT
IO
N S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
GENERAL NOTES
GRAPHIC SCALE(S)
0 2'
GRAPHIC SCALE 3/4" = 1'-0"
6" 1' 4'
3/4" = 1'-0"A1 MOUNTING HT - DOOR HOOK TYP.
3/4" = 1'-0"A2 MOUNTING HT -DOUBLE DOOR HOOK TYP.
GRAPHIC SCALE 3/8" = 1'-0"
8'2' 4'1'
3/8" = 1'-0"D1 299 TRAINING VTC - NORTH
3/8" = 1'-0"D2 299 TRAINING VTC - SOUTH
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
T05 T05
T05 T05
T05 T05
T05 T05
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02CH02
CH02
T05
CH02
T05
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02
T05T05
CH02
CH02
T05
CH02
CH02
T05
CH02
CH02
CH02
T05
CH02
T05
T05
T05
T05
CH02
CH02
T05
CH02
CH02
T05
CH02
CH02
CH02
CH02
T05ST05
ST05
ST02
CH04 CH04 CH04 CH04 CH04 CH04
A02
CH04CH04CH04CH04CH04
A02
CH05
TRAINING/
VTC
ADA/DMO
TRAINING
SUITE
STORAGE
241B
CLOSET
(X5)
(X54)
A01
MAX. STACK
(3) HIGH
A01
CH04
A07 A07
A07A07 A07
T05 T05
T05 T05
T05 T05
T05 T05
CH02
CH02
CH02
CH02
CH02
CH02
CH02
CH02CH02
CH02
T05
CH02
T05
CH02
CH02
CH02
CH02
CH02
ST05
ST02
A02 A02
TRAINING/
VTC
ADA/DMO
TRAINING
SUITE
STORAGE
241B
ST05
(X18)
CLEAR SPACE
FOR FOLDING
TABLE STORAGE
T09 (X9)
CH02 CLEAR SPACE FOR FOLDING
TABLE STORAGE T09 (X3)
CH02
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
04 CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
05 CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
A01 A01
CH
CH
CH
CH
CH
A07 A07
A07 A07
A07
FURNITURE PLAN LEGEND:
EXAMPLE:
CH 01
FURNISHING ITEM
FURNISHING CATEGORY
ABBREVIATIONS:
A ACCESSORIES
CH SEATING (ALL TYPES)
E EQUIPMENT
PO CASEGOODS
ST STORAGE
T TABLES
WS WORKSTATIONS
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERWISE NOTED.
4. FURNITURE LAYOUT IS FOR INFORMATION AND COORDINATION ONLY.
5. REFER TO THE FF&E SPECIFICATION PACKAGE FOR COMPLETE
SPECIFICATIONS AND REQUIREMENTS OF ALL FURNITURE ITEMS AND
QUANTITIES. PROVIDE ALL COMPONENTS REQUIRED TO FULFILL THE DESIGN
INTENT OUTLINED IN THE FF&E PACKAGE. INSTALL PER MANUFACTURER'S
WRITTEN INSTRUCTIONS.
6. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
7. DESIGNER OF RECORD (DOR) MUST BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT W OULD REQUIRE CHANGES TO THE LAYOUT AS SHOWN.
8. COORDINATE ELECTRICAL, PLUMBING, AND AUDIO-VISUAL REQUIREMENTS
WITH FURNITURE SPECIFCATIONS.
9. GENERAL CONTRACTORS ARE RESPONSIBLE FOR ELECTRICAL AND TELECOM
CONNECTIONS.
10. REFER TO SHEET I-900 FOR TYPICAL WORKSTATION LAYOUTS.
11. TYPICAL MOUNTING HEIGHT FOR A01 W ALL CLOCK IS 6'-0" AFF AND 1'-6" ON
CENTER FROM CLOSEST DOOR FRAME, UNLESS OTHERWISED NOTED.
12. TYPICAL MOUNTING HEIGHT FOR A07 MARKERBOARD IS 4'-0" AFF ON CENTER,
UNLESS OTHERW ISE NOTED.
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
6:
P M
I-4
-E N
LA
R
G E
D F
U R
N
IT
U R
E P
LA
N
S
I-400 302160
W
AS
H
IN
GT
O N D
.C
13134629
1673850
SAK SAK AB
EN
LA
RG
ED
F
U
RN
IT
U R E
PL
AN
S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
GENERAL NOTES
GRAPHIC SCALE(S)
KEY PLAN
KEYED NOTES#
1/4" = 1'-0"C1 TRAINING FURNITURE PLAN - OPTION 1
1/4" = 1'-0"A2 TRAINING FURNITURE PLAN - OPTION 2
GRAPHIC SCALE 1/4" = 1'-0"
2' 4' 8' 12'
N
N
1. PROVIDE (2) (A08) WASTE/RECYCLING RECEPTACLE - BINS IN EVERY (A02)
WASTE/RECYCLING RECEPTACLE.
2. FURNITURE IN GRAY SHOWN FOR REFERENCE ONLY, NOT IN CONTRACT.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
MOTHER'S
RM
WOMEN
294B
JAN
MEN
294A
CT-1
RWB-1
PT-1/3
GYP/PT-6
CT-1
RWB-1
PT-1
GYP/PT-5
CT-1
CT-8
CT3-6/PT-4
GYP/PT-6
CT-1
CT-8
CT3-6/PT-4
GYP/PT-6
EP-1
TS-2
CT-3/PT-4
EXP/PT-7
CPT-2
RWB-1
PT-1
ACT-1
PLUMBING
CLOSET
290C
EP-1
RWB-1
PT-1
EXP/PT-7
QZ-1/PL-1
SS-2
4 8
QZ-1/PL-1
SS-2
SS-1/PL-1
SS-2
CT-1 CPT-3
PT
-3
VEST
290A
VEST
290B
4 8 1 2
TILE (CT-1)
INSTALLATION
STARTING POINT
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERWISE NOTED.
4. REFER TO SHEET I-601 AND I-602 FOR INTERIOR FINISH KEY, INTERIOR FINISH
SCHEDULE AND MATERIAL CODE LEGEND.
5. ALL FLOOR TRANSITIONS BETWEEN ROOMS TO OCCUR AT CENTERLINE OF
DOOR UNLESS OTHERWISE NOTED. TRANSITIONS ARE NOT REQUIRED
BETWEEN MATERIALS OF SAME THICKNESS.
6. ALL WALLS TO BE PAINTED (PT-1) UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601 & I-602,
FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL FINISH IN A
'NON-VOC' PAINT UNLESS OTHERWISE NOTED. PROVIDE (1) PRIME COAT AND
(2) FINISH COATS OF PAINT.
7. ALL WALLS TO RECEIVE WALL BASE (RWB-1) UNLESS OTHERWISE NOTED.
8. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
9. REFER TO REFLECTED CEILING PLAN SHEETS A-151 AND A-152 FOR CEILING
DETAILS.
10. ALL WINDOW SILLS TO BE (SS-2), UNLESS OTHERWISE NOTED.
11. CORNER GUARDS TO BE INSTALLED ON ALL EXTERIOR CORNERS, UNLESS
OTHERWISE NOTED.
12. ALL METAL DOOR AND WINDOW FRAMES TO BE PAINTED (PT-5), UNLESS
OTHERWISE NOTED.
ACCESSIBLE
SHOWER/TOILET
ACCESSIBLE
SHOWER/TOILET
ACCESSIBLE
SHOWER/TOILET
ACCESSIBLE
SHOWER/TOILET
ACCESSIBLE
SHOWER/TOILET
JAN
STOR.
CT-1/CT-9
CT-8
CT3-6/PT-4
GYP/PT-6
CT-1/CT-9
CT-8
CT3-6/PT-4
GYP/PT-6
CT-1/CT-9
CT-8
CT3-6/PT-4
GYP/PT-6
CT-1/CT-9
CT-8
CT3-6/PT-4
GYP/PT-6
CT-1/CT-9
CT-8
CT3-6/PT-4
GYP/PT-6
VCT-1
RWB-1
PT-1
EXP/PT-7
EP-1
TS-2
CT-3/PT-4
GYP/PT-6
2 4
2 4
2 4
2 4
2 4
3 9
CT-1
CT-9
CT-9
CT-1
CT-1
CT-9
CT-1
CT-9
CT-9
CT-1
TILE (CT-1) INSTALLATION
STARTING POINT, TYP.
(ROOM 192, 193, 194)
TILE (CT-9) INSTALLATION
STARTING POINT, TYP.
(ROOM 192, 193, 194)
TILE (CT-1) INSTALLATION
STARTING POINT, TYP.
(ROOM 195, 196)
TILE (CT-9) INSTALLATION
STARTING POINT, TYP.
(ROOM 195, 196)
MILLWORK,
COUNTER TOP / CABINETRY
SYMBOL LEGEND
SINGLE PAINT FINISH
INTERIOR FINISH PLAN SYMBOLS
XX
XX/XX
ROOM FINISH TAGFLOOR
BASE
WALL
CEILING
SYMBOL LEGEND
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
6:
P M
I-4
-E N
LA
R
G
ED
F
IN
IS
H
P
LA
N S
I-401 302161
W
AS
H
IN
GT
O N D
.C
13134630
1673850
SAK SAK AB
EN
LA
R
GE
D F
IN
IS
H P
LA
N S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
1/4" = 1'-0"B2 292, 294, 296 - ENLARGED FINISH PLAN
GENERAL NOTES
GRAPHIC SCALE(S)
KEY PLAN
KEYED NOTES#
GRAPHIC SCALE 1/4" = 1'-0"
2' 4' 8' 12'
1/4" = 1'-0"B1 192, 193, 194, 195, 196 - ENLARGED FINISH PLAN
1. PROVIDE SOLID SURFACE WINDOW SILL (SS-2) WHERE NOTED. REFER TO
A2/A-311 AND A3/A-311 FOR DETAILS.
2. REFER TO I-200, I-201, AND I-204 FOR TOILET ROOM ELEVATIONS.
3. INSTALL CT-3 UP TO 5'-0", TOP WITH SCHLUTER TRANSITION STRIP (TS-1).
4. REFER TO INTERIOR FINISH SCHEDULE ON I-602 FOR W ALL FINISH
TRANSITIONS.
5. PROVIDE SCHLUTER TRANSITION STRIP BETWEEN TILE AND CARPET.
INSTALL BELOW TILE TO CREATE FINISHED EDGE (TS-4).
6. PROVIDE SCHLUTER TRANSITION STRIP REDUCER BETW EEN FLOORING
TYPES (TS-3).
7. IN AREAS WITH EXPOSED CEILING, PAINT WALL PAINT UP TO 8'-10" AFF.
START EXPOSED CEILING PAINT AT 8'-10" AFF TRANSITION AND EXTEND TO
DECK.
8. ALL WINDOW S TO RECEIVE WINDOW SHADE (WS-1). REFER TO W INDOW
DETAILS ON A-601 FOR DIMENSIONS. FIELD MEASURE AS NEEDED.
9. PROVIDE SCHLUTER COVE TRANSITION STRIP (TS-2) BETWEEN CERAMIC
WALL TILE AND EPOXY FLOORING. SEAL WITH SILICON AS NEEDED.
10. CERAMIC TILE (CT-9) TO BE INSTALLED ON SHOWER FLOOR ONLY. CUT AND
ANGLE AS NEEDED FOR SLOPING DRAIN.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
I-200A4
A2
B2
A3
I-200A1
B4
B3
ACCESSIBLE
SHOWER/TOILET
ACCESSIBLE
SHOWER/TOILET
I-200
B4
B3A1
I-200A4
A3
B2
A2
I-200B1B
C3
B1A
C4I-200C2 C1
ACCESSIBLE
SHOWER/TOILET
ACCESSIBLE
SHOWER/TOILET
ACCESSIBLE
SHOWER/TOILET
I-200 C1C2
I-200
C4
C3
B1B B1A
I-200B1B
C3
B1A
C4 I-200C2 C1
I-203
I-204B2
B1
B4
C3
B4
I-204
B3
I-204D2
D1 I-203
A1
I-204
D3
C1
I-204
C2
MOTHER'S
RM
WOMEN
294B
MEN
294A
A2
I-203 A3
I-203
I-203
C3
C2
I-203
C1
I-203B3
I-203
I-203
B1
B2 BREAK
ROOM
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
2. NOT ALL KEYED NOTES ON THIS SHEET ARE UTILIZED.
3. DIMENSIONS INDICATED ARE FROM FACE OF GYPSUM BOARD, UNLESS
OTHERW ISE NOTED.
4. REFER TO I-600 FOR INTERIOR FURNITURE AND EQUIPMENT SCHEDULES.
5. DESIGNER OF RECORD (DOR) TO BE NOTIFIED OF ANY DISCREPANCIES OR
INTERFERANCE THAT WOULD REQUIRE CHANGES TO THE LAYOUT AS
SHOWN.
6. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
7. REFER TO INTERIOR FINISH KEY ON SHEET I-601 FOR MATERIAL
DESCRIPTIONS AND INSTALLATION METHODS.
8. ALL W ALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. REFER TO
FINISH PLANS AND ROOM FINISH SCHEDULE SHEETS, I-102, I-104, I-601, &
I-602, FOR ACCENT PAINT LOCATIONS. ALL WALLS TO HAVE EGGSHELL
FINISH IN A 'NON-VOC' PAINT UNLESS OTHERW ISE NOTED. PROVIDE (1)
PRIME COAT AND (2) FINISH COATS OF PAINT.
9. ALL W ALLS TO RECEIVE WALL BASE RWB-1 UNLESS OTHERWISE NOTED.
10. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION
INSTRUCTIONS. PREP ALL SURFACES AS REQUIRED.
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
6:
P M
I-4
-E N
LA
R
G E
D
IN
TE
R
IO
R
E
LE
V
AT
IO
N
P
LA
N S
I-402 302162
W
AS
H
IN
GT
O N D
.C
13134631
1673850
SAK SAK AB
EN
LA
RG
ED
I N
TE
RI
O R E
LE
VA
TI
O N P
LA
N S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
1/4" = 1'-0"C1 195, 196 ACCESSIBLE SHOW ER / TOILET - ENLARGED PLAN
1/4" = 1'-0"C2 192, 193, 194 SHOW ER/ TOILET - ENLARGED PLAN
1/4" = 1'-0"A1 292 MEN, 294 W OMEN, 296 MOTHER'S RM - ENLARGED PLAN
1/4" = 1'-0"A2 288 BREAK ROOM - ENLARGED PLAN
GENERAL NOTES
GRAPHIC SCALE(S)
KEY PLAN
GRAPHIC SCALE 1/4" = 1'-0"
2' 4' 8' 12'
N N
N
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
Personnel Name / Title
Personnel Name
8"
8"
3/8
1 1 /2"
1"
3/4"
1"
1/2
1"
3/4
1/4"
SQUARE END CAP
ABS COLORED
PLAQUE
CLEAR ACRYLIC INSERT PANEL
WITH PAPER INSERTS
BRAILLE
1 1/2" TACTILE
ROOM NUMBER,
HELVETICA NEUE
55 ROMAN
Personnel Name
Personnel Name
Personnel Name
8"
3/4"
3/8
1 1 /2"
1"
8"
1" 1/4
1" 1/4
1" 1/4
1/4"
SQUARE END CAP
CLEAR ACRYLIC INSERT PANEL
WITH PAPER INSERTS
ABS COLORED
PLAQUE
BRAILLE
1 1/2" TACTILE
ROOM NUMBER,
HELVETICA NEUE
55 ROMAN
Personnel Name3"
8"
3/4
1" 3/4
1/4"
SQUARE END CAP
CLEAR ACRYLIC INSERT PANEL
WITH PAPER INSERTS
ABS COLORED
PLAQUE
Personnel Names
ROOM
3/8
1 1 /2"
1"
3/4"
8"
8"
3"
1/2
1/4"
SQUARE END CAP
CLEAR ACRYLIC INSERT PANEL
WITH PAPER INSERTS
ABS COLORED
PLAQUE
BRAILLE
3/4
ROOM DESIGNATION: UPPER CASE HELVETICA NEUE 55 ROMAN
3/4" CAPITAL LETTER HEIGHT, CENTERED,
ACCOMPANIED BY GRADE TWO BRAILLE
1 1/2" TACTILE
ROOM NUMBER,
HELVETICA NEUE
55 ROMAN
ROOM
3/8
1 1 /2"
1"
3/4"
8"
8"
3/8 "1
3/4"
1/4"
SQUARE END CAP
ABS COLORED
PLAQUE
BRAILLE
ROOM DESIGNATION: UPPER CASE HELVETICA NEUE 55 ROMAN
1" CAPITAL LETTER HEIGHT, CENTERED,
ACCOMPANIED BY GRADE TWO BRAILLE
1 1/2" TACTILE
ROOM NUMBER,
HELVETICA NEUE
55 ROMAN
Personnel Names
8"
3/4"
3/8
1 1 /2"
1"
8"
1/4"
3"
1/2
SQUARE END CAP
CLEAR ACRYLIC INSERT PANEL
WITH PAPER INSERTS
ABS COLORED
PLAQUE
BRAILLE
1 1/2" TACTILE
ROOM NUMBER,
HELVETICA NEUE
55 ROMAN
W OMEN
3/4" 6" 3/4"
4 1 /2"
3/4
1" 3/8
1/2
8"
8"
1/4"
SQUARE END CAP
ABS COLORED
PLAQUE
USE
INTERNATIONAL
PICTOGRAM
1" TACTILE ROOM DESCTIPTION WITH
BRAILLE, HELVETICA NEUE 55 ROMAN
MEN
3/4" 6" 3/4"
4 1 /2"
3/4
1" 3/8
1/2
1/4"
8"
8"
SQUARE END CAP
ABS COLORED
PLAQUE
USE
INTERNATIONAL
PICTOGRAM
1" TACTILE ROOM DESCTIPTION WITH
BRAILLE, HELVETICA NEUE 55 ROMAN
UNISEX
3/4" 6" 3/4"
4 1 /2"
3/4
1" 3/8
1/2
1/4"
8"
8"
SQUARE END CAP
ABS COLORED
PLAQUE
USE
INTERNATIONAL
PICTOGRAM
1" TACTILE ROOM DESCTIPTION WITH
BRAILLE, HELVETICA NEUE 55 ROMAN
UNISEX
1 1/2" 4 1/2" 1 1/2" 4 1
/2" 3/4
1" 3/8
1/2
1/4"
8"
8"
SQUARE END CAP
ABS COLORED
PLAQUE
USE
INTERNATIONAL
PICTOGRAM
1" TACTILE ROOM DESCTIPTION WITH
BRAILLE, HELVETICA NEUE 55 ROMAN
STAIR C
1/4"
1'
- 1
8"
SQUARE END CAP
ABS COLORED
PLAQUE
EXIT
3" 7 1
/2" 2"
1" 1/2
1 1
/2" 1/2
6" SYMBOL
1 1/2" TACTILE
STAIR
IDENTIFICATION
WITH BRAILLE,
HELVETICA NEUE
55 ROMAN
1" TACTILE EXIT
IDENTIFICATION
WITH BRAILLE,
HELVETICA NEUE
55 ROMAN
STAIR D
1/4"
1'
- 1
8"
SQUARE END CAP
ABS COLORED
PLAQUE
EXIT
3" 7 1
/2" 2"
1" 1/2
1 1
/2" 1/2
6" SYMBOL
1. VERIFY AND COORDINATE ALL SIGNAGE TYPES, ROOM NAMES AND ROOM
NUMBERS WITH GOVERNMENT PRIOR TO FABRICATION.
2. REFER TO SHEET I-500 AND I-501 FOR SIGNAGE TYPICALS.
3. REFER TO SHEET I-502 AND I-503 FOR MOUNTING HEIGHTS.
4. REFER TO SHEET I-603 FOR SIGNAGE SCHEDULE.
5. ALL SIGN TYPES TO MATCH EXISTING SIGNAGE FINISHES WITHIN JADOC I
EXISTING BUILD OUT. REFER TO EXISTING SIGNAGE FOR COLOR
SELECTIONS.
6. ALL SIGNS TO BE GRAPHIC BLAST RAISED COPY CONSTRUCTION. REFER TO
EXISTING SIGNAGE IN JADOC I FOR REFERENCE.
7. SIGNAGE TO COMPLY WITH REQUIREMENTS OF ADAAG, ADA ACCESSIBILITY
AND AFSA, UNIFORM FEDERAL ACCESSIBILITY STANDARDS.
8. ALL SIDES THAT ARE WALL MOUNTED NEXT TO A DOOR WILL BE MOUNTED
ON THE LATCH SIDE OF THE DOOR, UNLESS NOTED OTHERWISE.
9. PRESSURE SENSITIVE ADHESIVE MOUNTING FOR ALL SIGNS ON SMOOTH,
HARD SURFACES.
10. SCREW-ON MOUNTING PER SIGN SYSTEM MANUFACTURER'S DIRECTIONS
ON TEXTURED SURFACES.
11. BRAILLE SHOWN FOR REPRESENTATION PURPOSES ONLY. VERIFY
APPROPRIATE CHARACTERS AND LOCATIONS PRIOR TO FABRICATION.
12. ALL SIGNS THAT ARE MOUNTED TO GLASS, PROVIDE LAMINATE BACK
PANEL TO MATCH SIGNAGE FACE.
13. ALL EXTERIOR SIGNAGE AT BUILDING TO BE EXTERIOR GRADE, 1 5/8" THICK.
1'
- 0
1' - 3"
FACILITY NAME: XXXXX
1" 1' - 0 1/2" 1"
APPLIED RECOGNITION: XXXXX
XXXXX
DATE OF OCCUPANCY: XXXXX
THIRD PARTY CERTIFICATION:
XXXXX
USING ACTIVITY C.O.
BUILDING C.O.
FACILITY C.O.
PRIME CONTRACTOR: XXXXX
ARCHITECT / ENGINEER: XXXXX
3/4
3/4
1/4 " T
YP
FACILITY RECOGNITION PLAQUE: UPPER CASE TIMES NEW ROMAN
1/2" CAPITAL LETTER HEIGHT, LEFT JUSTIFIED, TYPICAL 1/4" GAP
BETWEEN LINES OF TEXT, TYPICAL 3/4" GAP BETWEEN TEXT AND
PLAQUE BORDER
1/4"
RECOGNITION PLAQUE COMMEMORATING THE OPENING OF THE FACILITY AND RECOGNIZING THE
LEADERSHIP PARTICIPANTS WITH THE PROJECT. PLAQUE TO INCLUDE THE FOLLOWING
INFORMATION:
• FACILITY NAME
• IDENTIFY ANY RECOGNITION APPLIED TO THE FACILITY OR PERSON FOR WHICH THE FACILITY
HAS BEEN DEDICATED
• DATE AND OCCUPANCY (MONTH/YEAR)
• THIRD PARTY CERTIFICATION ACHIEVED
• USING ACTIVITY COMMANDER / COMMANDING OFFICER
• BASE COMMANDER / COMMANDING OFFICER
• NAVFAC COMPONENT COMMADER / FACILITY ENGINERRING COMPONENT COMMANDING
OFFICER
• PRIME CONTRACTOR
• ARCHITECT / ENGINEER (MAIN FACILITY DESIGNER)
CONFIRM CONTENT MESSAGE AND MOUNTING WITH CONTRACTING OFFICER PRIOR TO
FABRICATION. THE NAMES ON THE PLAQUE MUST BE DETERMINED AT THE END OF PROJECT
DURATION TO ASSURE CURRENT PARTITIPANTS CAN BE IDENTIFIED AND RECOGNIZED.
1/4" SATIN BRONZE
FLAT BAND STRAIGHT
EDGE BORDER
BAS RELIEF DARK BRONZE
BACKGROUND, LEATHER
TEXTURE
1/2" SATIN BRONZE
TIMES NEW ROMAN
CAPITAL
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
6:
P M
I-5
-S
IG
N A
G E
T
YP
IC
A
LS
I-500 302163
W
AS
H
IN
GT
O N D
.C
13134632
1673850
SAK SAK AB
SI
GN
AG
E
TY
P
IC
AL
S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3" = 1'-0"D2 SIGN TYPE A2 - OFFICE SIGN / 2P OFFICE
3" = 1'-0"D3 SIGN TYPE A3 - OFFICE SIGN 3P3" = 1'-0"D1 SIGN TYPE A1 - W ORKSTATION SIGN
3" = 1'-0"C1 SIGN TYPE A5 - OFFICE SIGN ID & MULTI USER
3" = 1'-0"C2 SIGN TYPE B1 - ROOM ID
3" = 1'-0"D4 SIGN TYPE A4 - OFFICE SIGN 4P
3" = 1'-0"C3 SIGN TYPE D1 - PUBLIC TOILET, W OMEN
3" = 1'-0"C4 SIGN TYPE D2 - PUBLIC TOILET, MEN
3" = 1'-0"B1 SIGN TYPE D3 - PUBLIC TOILET
3" = 1'-0"B2 SIGN TYPE D3A - TOILET
3" = 1'-0"A1 SIGN TYPE E1A - STAIRS
3" = 1'-0"A2 SIGN TYPE E1B- STAIRS
GENERAL NOTES
GRAPHIC SCALE(S)
0 6" 1'
GRAPHIC SCALE 3" = 1'-0"
3"
3" = 1'-0"A3 SIGN TYPE P1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
STAIR D
1' - 2"
1'
- 7
1/ 2"
LEVEL
FLOORS 1 TO 2
EXIT THIS LEVEL
1/4
2" 1"
1/2 " 1"
1/2 " 1"
1 1 /2"
5" 2"
1" 1"
1 1 /2"
1" 1/4
" 1/4"
BRAILLE ONE LINE
STAIR DESIGNATION: UPPER CASE HELVETICA NEUE 65 MEDIUM
1-1/2" CAPITAL LETTER HEIGHT, CENTERED
FLOOR NUMBER: HELVETICA NEUE 65 MEDIUM, 5" TEXT HEIGHT,
CENTERED
TEXT: UPPER CASE HELVETICA NEUE 55 ROMAN, 1" CAPITAL LETTER
HEIGHT, CENTERED, ACCOMPANIED BY GRADE TW O BRAILLE
ROOF ACCESS
STAIR C
1' - 2"
1'
- 7
1/ 2"
LEVEL
NO ROOF ACCESS
1/4
2" 1"
1/2 " 1"
1/2 " 1"
1 1 /2"
5" 2"
1" 1"
1 1 /2"
1" 1/4
" 1/4"
BRAILLE ONE LINE
STAIR DESIGNATION: UPPER CASE HELVETICA NEUE 65 MEDIUM
1-1/2" CAPITAL LETTER HEIGHT, CENTERED
FLOOR NUMBER: HELVETICA NEUE 65 MEDIUM, 5" TEXT HEIGHT,
CENTERED
TEXT: UPPER CASE HELVETICA NEUE 55 ROMAN, 1" CAPITAL LETTER
HEIGHT, CENTERED, ACCOMPANIED BY GRADE TWO BRAILLE
FLOORS 1 TO 2
EXIT ON LEVEL 1
STAIR D
1' - 2"
1'
- 7
1/ 2"
LEVEL
FLOORS 1 TO 2
1/4
2" 1"
1/2 " 1"
1/2 " 1"
1 1 /2"
5" 2"
1" 1"
1 1 /2"
1" 1/4
" 1/4"
BRAILLE ONE LINE
STAIR DESIGNATION: UPPER CASE HELVETICA NEUE 65 MEDIUM
1-1/2" CAPITAL LETTER HEIGHT, CENTERED
FLOOR NUMBER: HELVETICA NEUE 65 MEDIUM, 5" TEXT HEIGHT,
CENTERED
TEXT: UPPER CASE HELVETICA NEUE 55 ROMAN, 1" CAPITAL LETTER
HEIGHT, CENTERED, ACCOMPANIED BY GRADE TWO BRAILLE
EXIT ON LEVEL 1
ROOF ACCESS
1. VERIFY AND COORDINATE ALL SIGNAGE TYPES, ROOM NAMES AND ROOM
NUMBERS WITH GOVERNMENT PRIOR TO FABRICATION.
2. REFER TO SHEET I-500 AND I-501 FOR SIGNAGE TYPICALS.
3. REFER TO SHEET I-502 AND I-503 FOR MOUNTING HEIGHTS.
4. REFER TO SHEET I-603 FOR SIGNAGE SCHEDULE.
5. ALL SIGN TYPES TO MATCH EXISTING SIGNAGE FINISHES WITHIN JADOC I
EXISTING BUILD OUT. REFER TO EXISTING SIGNAGE FOR COLOR
SELECTIONS.
6. ALL SIGNS TO BE GRAPHIC BLAST RAISED COPY CONSTRUCTION. REFER TO
EXISTING SIGNAGE IN JADOC I FOR REFERENCE.
7. SIGNAGE TO COMPLY WITH REQUIREMENTS OF ADAAG, ADA ACCESSIBILITY
AND AFSA, UNIFORM FEDERAL ACCESSIBILITY STANDARDS.
8. ALL SIDES THAT ARE WALL MOUNTED NEXT TO A DOOR WILL BE MOUNTED
ON THE LATCH SIDE OF THE DOOR, UNLESS NOTED OTHERWISE.
9. PRESSURE SENSITIVE ADHESIVE MOUNTING FOR ALL SIGNS ON SMOOTH,
HARD SURFACES.
10. SCREW-ON MOUNTING PER SIGN SYSTEM MANUFACTURER'S DIRECTIONS
ON TEXTURED SURFACES.
11. BRAILLE SHOWN FOR REPRESENTATION PURPOSES ONLY. VERIFY
APPROPRIATE CHARACTERS AND LOCATIONS PRIOR TO FABRICATION.
12. ALL SIGNS THAT ARE MOUNTED TO GLASS, PROVIDE LAMINATE BACK
PANEL TO MATCH SIGNAGE FACE.
13. ALL EXTERIOR SIGNAGE AT BUILDING TO BE EXTERIOR GRADE, 1 5/8" THICK.
STAIR C
1' - 2"
1'
- 7
1/ 2"
LEVEL
FLOORS 1 TO 2
EXIT THIS LEVEL
1/4
2" 1"
1/2 " 1"
1/2 " 1"
1 1 /2"
5" 2"
1" 1"
1 1 /2"
1" 1/4
" 1/4"
BRAILLE ONE LINE
STAIR DESIGNATION: UPPER CASE HELVETICA NEUE 65 MEDIUM
1-1/2" CAPITAL LETTER HEIGHT, CENTERED
FLOOR NUMBER: HELVETICA NEUE 65 MEDIUM, 5" TEXT HEIGHT,
CENTERED
TEXT: UPPER CASE HELVETICA NEUE 55 ROMAN, 1" CAPITAL LETTER
HEIGHT, CENTERED, ACCOMPANIED BY GRADE TWO BRAILLE
NO ROOF ACCESS
1' - 0"
8"
1/4
1/4 " 2"
5" 1/4
1/4
" 1/4"
BRAILLE TWO LINE
5/8" MESSAGE TEXT
HEIGHT, HELVETICA
NEUE 55 ROMAN
W ARNING
IN CASE OF APPLINANCE FIRE,
USE THIS EXTINGUISHER
AFTER FIXED SUPRESSION
SYSTEM HAS BEEN ACTIVATED
SQUARE END CAP
ABS COLORED
PLAQUE
9"
3"
1/2
1/4
3/4
1/4"
BRAILLE ONE LINE 3/4" MESSAGE TEXT
HEIGHT, HELVETICA
NEUE 55 ROMAN
EXIT
SQUARE END CAP
ABS COLORED
PLAQUE
1/2
1/4
1/2
1/4
IN CASE OF FIRE,
USE EXIT STAIRS UNLESS
OTHERW ISE INSTRUCTED
1/4"
1'
- 5
1' - 0"SQUARE END CAP
ABS COLORED
PLAQUE
4" 1'
- 0 1/
2"
5/8" MESSAGE TEXT,
HELVETICA NEUE 55
ROMAN
CLEAR ACRYLIC
INSERT PANEL
REPLACABLE
EVACUATION MAP
10"
1'
- 2
1. PLAQUE TO BE MOUNTED ON W ALL.
2. SEMI-RIGID 1MM PVC PLASTIC, UV-STABLE INK
3. SIGN COMFORMS TO OSHA 29 CFR 1910.145
STANDARD FOR HEADER STYLE, TEXT FORMAT
AND HEADER COLOR
1' - 2"
1. PLAQUE TO BE MOUNTED ON W ALL.
2. SEMI-RIGID 1MM PVC PLASTIC, UV-STABLE INK
3. SIGN COMFORMS TO OSHA 29 CFR 1910.145
STANDARD FOR HEADER STYLE, TEXT FORMAT AND
HEADER COLOR
8"
4"
1. PLAQUE TO BE MOUNTED ON W ALL.
2. RED COLOR 1/16" ADA ACRYLIC CORE W ITH 1/32"
PRECISION CUT TOP COLOR LAYER. MATTE FINISH
FOR IMPROVED VISIBILITY. GRADE 2 BRAILLE
3. SIGN COMFORMS TO ADA/ADAAG GUIDELINES
4"
1'
- 2
1. PLAQUE TO BE MOUNTED ON WALL.
2. SEMI-RIGID PVC PLASTIC, PRINTED
W ITH UV-STABLE INK.
1' - 2"
1. PLAQUE TO BE MOUNTED ON WALL.
2. SEMI-RIGID 1MM PVC PLASTIC, UV-STABLE INK
3. SIGN COMFORMS TO OSHA 29 CFR 1910.145 STANDARD FOR
HEADER STYLE, TEXT FORMAT AND HEADER COLOR
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
7:
P M
I-5
-S
IG
N A
G E
T
YP
IC
A
LS
I-501 302164
W
AS
H
IN
GT
O N D
.C
13134633
1673850
SAK SAK AB
SI
GN
AG
E
TY
P
IC
AL
S
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3" = 1'-0"C1 SIGN TYPE E2A
3" = 1'-0"C3 SIGN TYPE E2B
GENERAL NOTES
GRAPHIC SCALE(S)
0 6" 1'
GRAPHIC SCALE 3" = 1'-0"
3"
3" = 1'-0"C4 SIGN TYPE E2C
3" = 1'-0"C2 SIGN TYPE E2D
3" = 1'-0"B1 SIGN TYPE F1 - TYPE K FIRE EXTINGUISHER
3" = 1'-0"B2 SIGN TYPE F2 - EXIT DOOR
3" = 1'-0"A4 SIGN TYPE F3 -EGRESSS SIGN
3" = 1'-0"A1 SIGN TYPE F4A - EYEW ASH/SHOW ER
3" = 1'-0"A2 SIGN TYPE F5 - RESTRICTED AREA
3" = 1'-0"B3 SIGN TYPE F6B - FIRE EXTINGUISHER
3" = 1'-0"A3 SIGN TYPE F6A - FIRE EXTINGUISHER
3" = 1'-0"B4 SIGN TYPE F4B - EYEW ASH
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
EQ EQ
MO
UN
TI
NG
H
EI
GH
T
5'
- 0
SIGN TYPE F5
3"
MO
UN
TIN
G
HE
IG
HT
5'
- 0
CE
NT
ER
LI
NE
4'
- 0
SIGN TYPE VARIES
CARD READER, WHERE APPLICABLE,
REFER TO AV PACKAGE FOR MORE
INFORMATION EQ. EQ.
MO
UN
TIN
G
HE
IG
HT
5'
- 0
SIGN TYPE B
1. VERIFY AND COORDINATE ALL SIGNAGE TYPES, ROOM NAMES AND ROOM
NUMBERS WITH GOVERNMENT PRIOR TO FABRICATION.
2. REFER TO SHEET I-500 AND I-501 FOR SIGNAGE TYPICALS.
3. REFER TO SHEET I-502 AND I-503 FOR MOUNTING HEIGHTS.
4. REFER TO SHEET I-603 FOR SIGNAGE SCHEDULE.
5. ALL SIGN TYPES TO MATCH EXISTING SIGNAGE FINISHES WITHIN JADOC I
EXISTING BUILD OUT. REFER TO EXISTING SIGNAGE FOR COLOR
SELECTIONS.
6. ALL SIGNS TO BE GRAPHIC BLAST RAISED COPY CONSTRUCTION. REFER TO
EXISTING SIGNAGE IN JADOC I FOR REFERENCE.
7. SIGNAGE TO COMPLY WITH REQUIREMENTS OF ADAAG, ADA ACCESSIBILITY
AND AFSA, UNIFORM FEDERAL ACCESSIBILITY STANDARDS.
8. ALL SIDES THAT ARE WALL MOUNTED NEXT TO A DOOR WILL BE MOUNTED
ON THE LATCH SIDE OF THE DOOR, UNLESS NOTED OTHERWISE.
9. PRESSURE SENSITIVE ADHESIVE MOUNTING FOR ALL SIGNS ON SMOOTH,
HARD SURFACES.
10. SCREW-ON MOUNTING PER SIGN SYSTEM MANUFACTURER'S DIRECTIONS
ON TEXTURED SURFACES.
11. BRAILLE SHOWN FOR REPRESENTATION PURPOSES ONLY. VERIFY
APPROPRIATE CHARACTERS AND LOCATIONS PRIOR TO FABRICATION.
12. ALL SIGNS THAT ARE MOUNTED TO GLASS, PROVIDE LAMINATE BACK
PANEL TO MATCH SIGNAGE FACE.
13. ALL EXTERIOR SIGNAGE AT BUILDING TO BE EXTERIOR GRADE, 1 5/8" THICK.
3"
MO
UN
TIN
G
HE
IG
HT
5'
- 0
SIGN TYPE VARIES
MO
UN
TIN
G
HE
IG
HT
, M
ID
PO
IN
T
5'
- 0
SIGN TYPE F4A, F4B, F6B
MO
UN
TIN
G
HE
IG
HT
, M
ID
PO
IN
T
5'
- 0
8"
SIGN TYPE F6B
SIGN TYPE F1
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
7:
P M
I-5
-T
YP
IC
A
L S
IG
N
A G
E M
O U
N
TI
N G
H E
IG
H
TS
I-502 302165
W
AS
H
IN
GT
O N D
.C
13134634
1673850
SAK SAK AB
TY
PI
C
AL
S
IG
N
AG
E M O U N
TI
N G
H
EI
GH
TS
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3/4" = 1'-0"A2 MOUNTING HT - SIGN TYPE F5
3/4" = 1'-0"C2 MOUNTING HT - SIGN TYPE A & CARD READER
3/4" = 1'-0"C3 MOUNTING HT - SIGN TYPE B W ITH SIDELIGHT
GENERAL NOTES
GRAPHIC SCALE(S)
0 2'
GRAPHIC SCALE 3/4" = 1'-0"
6" 1' 4'
3/4" = 1'-0"C1 MOUNTING HT - SIGN TYPE A, B, D, E, F2, F3
3/4" = 1'-0"A1 MOUNTING HT - SIGN TYPE F4A, F4B, F6B
3/4" = 1'-0"A3 MOUNTING HT - SIGN TYPE F6B W ITH F1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
SIGN TYPE A53"
EQ
EQ
MO
UN
TI
NG
H
EI
GH
T
4'
- 1
1"
1. VERIFY AND COORDINATE ALL SIGNAGE TYPES, ROOM NAMES AND ROOM
NUMBERS WITH GOVERNMENT PRIOR TO FABRICATION.
2. REFER TO SHEET I-500 AND I-501 FOR SIGNAGE TYPICALS.
3. REFER TO SHEET I-502 AND I-503 FOR MOUNTING HEIGHTS.
4. REFER TO SHEET I-603 FOR SIGNAGE SCHEDULE.
5. ALL SIGN TYPES TO MATCH EXISTING SIGNAGE FINISHES WITHIN JADOC I
EXISTING BUILD OUT. REFER TO EXISTING SIGNAGE FOR COLOR
SELECTIONS.
6. ALL SIGNS TO BE GRAPHIC BLAST RAISED COPY CONSTRUCTION. REFER TO
EXISTING SIGNAGE IN JADOC I FOR REFERENCE.
7. SIGNAGE TO COMPLY WITH REQUIREMENTS OF ADAAG, ADA ACCESSIBILITY
AND AFSA, UNIFORM FEDERAL ACCESSIBILITY STANDARDS.
8. ALL SIDES THAT ARE WALL MOUNTED NEXT TO A DOOR WILL BE MOUNTED
ON THE LATCH SIDE OF THE DOOR, UNLESS NOTED OTHERWISE.
9. PRESSURE SENSITIVE ADHESIVE MOUNTING FOR ALL SIGNS ON SMOOTH,
HARD SURFACES.
10. SCREW-ON MOUNTING PER SIGN SYSTEM MANUFACTURER'S DIRECTIONS
ON TEXTURED SURFACES.
11. BRAILLE SHOWN FOR REPRESENTATION PURPOSES ONLY. VERIFY
APPROPRIATE CHARACTERS AND LOCATIONS PRIOR TO FABRICATION.
12. ALL SIGNS THAT ARE MOUNTED TO GLASS, PROVIDE LAMINATE BACK
PANEL TO MATCH SIGNAGE FACE.
13. ALL EXTERIOR SIGNAGE AT BUILDING TO BE EXTERIOR GRADE, 1 5/8" THICK.
6'
- 0
8"
SIGN TYPE F6AEQ EQ
EXTINGUISHER
CABINET
4'
- 0
1'
- 0
SIGN TYPE F6B
EQ EQ FIRE
EXTINGUISHER
5'
- 0
SIGN TYPE P1
1' - 3"
1'
- 0
EQ EQ
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
7:
P M
I-5
-T
YP
IC
A
L S
IG
N
A G
E M
O U
N
TI
N G
H E
IG
H
TS
I-503 302166
W
AS
H
IN
GT
O N D
.C
13134635
1673850
SAK SAK AB
TY
PI
C
AL
S
IG
N
AG
E M O U N
TI
N G
H
EI
GH
TS
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
3/4" = 1'-0"C1 MOUNTING HT - W ORKSTATION SIGNAGE A5
GENERAL NOTES
GRAPHIC SCALE(S)
0 2'
GRAPHIC SCALE 3/4" = 1'-0"
6" 1' 4'
3/4" = 1'-0"C2 MOUNTING HT - SIGN TYPE F6A
3/4" = 1'-0"C3 MOUNTING HT - SIGN TYPE F6B
3/4" = 1'-0"A1 MOUNTING HT - SIGN TYPE P1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
2' - 0"
RE
FE
R
TO
E
LE
VA
TI
ON
S
1 1 /2"
SCHEDULED FLOORING
SCHEDULED BASE
APPLIED TO MILLWORK
TOEKICK
4"
SCHEDULED PULL
DRAWER FRONT,
P.LAM ALL SIDES
DRAWER INTERIOR,
P.LAM
CABINET INTERIOR,
P.LAM
CABINET INTERIOR, P.LAM
CABINET INTERIOR, P.LAM
CABINET INTERIOR, P.LAM
SPECIFIED HINGE
SPECIFIED PULL
SCHEDULED W ALL FINISH
SCHEDULED COUNTERTOP
& EDGE
SILICON SEAL WHERE
WALL MEETS
COUNTERTOP
1'
- 3
1'
- 3
1'
- 1
1 1 /2"
1' - 8"
CL
EA
R
IN
SI
DE
H
EI
GH
T
1'
- 2
VE
RI
FY
W
IT
H
EQ
UI
PM
EN
T
SP
EC
S.
1'
- 1
5/ 8"
DOOR FRONT, P.LAM ALL SIDES
3"
2' - 0"
RE
FE
R
TO
E
LE
VA
TI
ON
S
SILICONE SEAL WHERE WALL MEETS
COUNTER TOP
SCHEDULED TOP & EDGE
1 1 /2"
STEEL TUBE COUNTER SUPPORT
HIDDEN IN WALL COUNTER
TOP SUPPORT
SCHEDULED W ALL AND BASE
SCHEDULED FLOORING
CABINET INTERIOR, P.LAM
CABINET INTERIOR, P.LAM
SPECIFIED HINGE
SPECIFIED PULL
3'
- 0
1' - 3"
DOOR FRONT, P.LAM ALL SIDES
2"
UNDER CABINET LIGHTING
AQJUSTABLE SHELVES (QTY. 3)
2' - 0"
RE
FE
R
TO
E
LE
VA
TI
ON
S
1 1 /2"
SCHEDULED FLOORING
SCHEDULED BASE
APPLIED TO MILLWORK
TOEKICK
4"
SCHEDULED COUNTERTOP
& EDGE
SCHLUTER COVE TRANSISITON STRIP
WHERE BACKSPLASH MEETS
COUNTER TOP, SILICON SEAL WHERE
COUNTER TOP MEETS WALL
3"
SCHEDULED PULL
DOOR FRONT,
P.LAM ALL SIDES
CABINET INTERIOR,
P.LAM
ADJ. SHELF, P.LAM
SCHEDULED HINGE
2' - 0"
RE
FE
R
TO
E
LE
VA
TI
ON
S
1 1 /2"
SCHEDULED FLOORING
SCHEDULED BASE
APPLIED TO MILLWORK
TOEKICK
4"
SCHEDULED PULL
DRAWER FRONT,
P.LAM ALL SIDES
DRAWER INTERIOR,
P.LAM
SCHEDULED COUNTERTOP
& EDGE
SILICON SEAL WHERE
WALL MEETS
COUNTERTOP
3"
SCHEDULED PULL
DOOR FRONT,
P.LAM ALL SIDES
CABINET INTERIOR,
P.LAM
ADJ. SHELF, P.LAM
SCHEDULED HINGE
7"
2' - 0"
RE
FE
R
TO
E
LE
VA
TI
ON
S
1 1 /2"
SCHEDULED FLOORING
SCHEDULED BASE
APPLIED TO MILLWORK
TOEKICK
4"
SCHEDULED COUNTERTOP
& EDGE
SILICON SEAL WHERE COUNTER TOP
MEETS WALL
3"
SCHEDULED PULL
DRAWER FRONT,
P.LAM ALL SIDES
CABINET INTERIOR,
P.LAM
8"
CLEAR
1' - 10"
A03, QTY 1
1. REFER TO GENERAL SHEET G-003 FOR GENERAL NOTES, ABBREVIATIONS,
SYMBOLS AND STANDARD CONSTRUCTION DETAILS.
A
B
C
D
1 2 3 4 5
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE 10/27/2021
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
D E P A R T M E N T
O F
TH
E
N A V Y
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DRAWFORM REVISION: 10 MARCH 2009
<<PM-DM>> MDR/MLR
BRANCH MANAGER GR
CHIEF ENG/ARCH TC
FIRE PROTECTION JG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
AS NOTED
1 2 3 4 5
Approved by AFCEC via email
FOUO
FOUO
/2 2/
:3
7:
P M
I-5
-M
IL
LW
O
R K
D E
TA
IL
S
I-504 302167
W
AS
H
IN
GT
O N D
.C
13134636
1673850
SAK SAK AB
M
IL
LW
O
RK
D
ET
AI
LS
JO
IN
T B
AS
E
AN
AC
O
ST
IA
B O
LL
IN
G
P-
JA
D
O C
P H
AS
E
II
N A
VA
L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D , W
AS
H
IN
G
TO
N
D .C
W
AS
H
IN
GT
O N D
.C
TH
E
N
AV
Y
YA
RD
1 1/2" = 1'-0"B1 MICROW AVE BASE AND UPPER CABINETS
1 1/2" = 1'-0"C2 COUNTER TOP W ITH IN W ALL SUPPORT AT W INDOW
1 1/2" = 1'-0"A1 UPPER CABINETS
1 1/2" = 1'-0"C3 BASE CABINET W / DOOR
1 1/2" = 1'-0"A2 BASE CABINET W / DOOR & DRAW ER
1 1/2" = 1'-0"A3 BASE CABINET W / PULL OUT TRASH (1 BIN)
GENERAL NOTES
GRAPHIC SCALE(S)
0 2'
GRAPHIC SCALE 1 1/2" = 1'-0"
6" 1'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
FE
R
TO
E
LE
VA
TI
ON
S
1 1 /2"
SCHEDULED FLOORING
SCHEDULED BASE
APPLIED TO MILLWORK
TOEKICK
4"
SCHEDULED COUNTERTOP
& EDGE
SCHLUTER COVE TRANSISITON STRIP
WHERE…
This is the start of the file's text. The full file is on GovTribe.