Attachment_03_-_Meeting_List_150319.docx
DOCX document 51 KB Posted
- Attached to
- Amphibious Combat Vehicle 1. 1 Federal contract opportunity
- Solicitation number
- M67854-15-R-0001
- Issued by
- United States Marine Corps
About this file
Attachment 03 - Meeting List 150319
View the file
Other files for this federal contract opportunity
Show all 50
Amphibious Combat Vehicle 1. 1 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M67854-15-R-0001 Section J
Attachment 03 Meeting List 19 Mar 2015
| M67854-15-R-0001 |
| Section J |
Attachment 03 – Meeting List
| Type of Activity |
| Paragraph/ |
Attachment Number
| Location |
| Meeting Duration |
| Deliverable |
| Meeting Date |
| Program Protection Review Meetings |
| 3.1.4.1 |
| Contractor Facility |
| 1 day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) #1: 285 calendar days after contract award.
#2: 520 calendar days after contract award #3: 780 calendar days after contract award
| Program Management Reviews (Government Led) |
| 3.1.4.2, 3.2.2.3 |
| Government Facility |
| 1 day |
| Minutes (CDRL A008); Deliverables per SOW |
| For EMD, within 67-72 calendar days after execution of the EMD Vehicle Build CLINS and quarterly thereafter. For LRIP/FRP, 60 days after execution of the LRIP/FRP Build CLINS (Options, if Exercised) and quarterly thereafter, until the delivery of the last LRIP vehicle |
| Post Award Conference (PAC) for the EMD Vehicle Build CLINS (Government Led) |
| 3.2.2.1.1 |
| Government |
Facility
| No more than 1 day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) Within 20 calendar days after contract award
Contract Option Post Award Conference for LRIP/FRP Build CLINs. (Government Led)
| 3.2.2.1.2 |
| Government |
Facility
| No more than 1 day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) Within 20 calendar days after option exercise
| Cost and Software Data Reporting Post Award Conference |
| 3.2.8.1 |
| Government Facility |
| 1 day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) Within 20 days after contract award in conjunction with the Post Award Conference
| System Requirements Review-II |
| 3.3.1.1 |
| Government Facility |
| 1 day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) One (1) calendar day following the Post Award Conference
Preliminary Design Review (PDR)/Critical Design Review (CDR)
3.3.1.2, 3.4.2.1
| Government Facility |
| 2 days |
| CDRL A007: Conference Presentation Materials, and SOW |
| No sooner than 100 days after contract award, but no later than 114 days after contract award |
| Vehicle Acceptance Review |
| 3.3.1.3 |
| Government Facility |
| 1 day |
| CDRLs defined by the SOW |
| No later than 30 days prior to the start of Government Developmental Testing |
System Verification Review (SVR)
| 3.3.1.4 |
| Government Facility |
| 1 day |
| CDRL A109: System Verification Review, and SOW |
| 70-80 days after completion of the last system verification test |
| Production Readiness Review |
| 3.3.1.5 |
| Contractor Facility |
| 2 days |
| CDRL A110 – PRR Presentation |
| 10 Months Prior to |
MS C
| Physical Configuration Audit (PCA) Planning Meeting |
| 3.3.10.3 |
| Contractor Facility |
| 2 days |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) No later than 210 days after LRIP Option 1 Contract Modification
| PCA Kick-Off Meeting |
| 3.3.10.3 |
| Contractor Facility |
| 1 day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) No later than 15 days after PCA vehicle completes Acceptance Test
| PCA Close-Out Meeting |
| 3.3.10.3 |
| Contractor Facility |
| 1 day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) No later than 30 days after completion of the vehicle physical audit
| Government Safety Reviews and Audits |
| 3.3.14.2 |
| Government Facility |
| 1 day |
| Per MIL-STD-882E. Task 104: 104.1-104.2.2 |
| Two (2) Weapon System Explosive Safety Review Board (WSESRB) Conferences |
One (1) Laser Safety Review Board (if required during EMD Phase)
| Vulnerability Model Reviews |
| 3.3.21.2 |
| Government Facility |
| No more than 1 day |
| Minutes (CDRL A008) |
| Within 60 days after Contract award, |
Within 60-180 days after Contract award, & Within 45 Days after last system verification, identified in the Government IMS
| Failure Prevention Review Board Meeting |
| 3.3.33 |
| Government Facility |
| No more than 1 day |
| N/A |
| No later than 30 days after completion of PCA and monthly thereafter until the end of the LRIP (Lot 2) (Option, if exercised) |
| MRA MS C Capstone Meeting |
| 3.4.2.2 |
| CONUS Location |
| 2 Days |
| Assessment according to CDRL: Manufacturing Readiness Self-Assessment |
| Six (6) months prior to MS C approval |
| MRA FRP Capstone Meeting |
| 3.4.2.3 |
| CONUS Location |
| 2 Days |
| Assessment according to CDRL: Manufacturing Readiness Self-Assessment |
| FRP: Eight (8) months prior to FRP (Option, if Exercised) |
Acceptance Test Readiness Review
(ATRR)
| 3.4.7.6 |
| Contractor Facility |
| 2 Days |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) 30 days prior to initiation of the AT for the first vehicle that completes EMD production and 30 days prior to initiation of the AT for the first vehicle that completes LRIP (Lot 1) production (Option, if exercised)
| Government Developmental Test (GDT) Readiness Review (DTRR) #2 |
| 3.5.1.8.1 |
| Contractor Facility |
| 1 day |
| Agenda (CDRL A006), |
Minutes (CDRL A008), Test Readiness Review (CDRL A090), and SOW 60 days prior to first GDT event
| DTRR #3 |
| 3.5.1.8.1 |
| Government |
Facility
| 1 day |
| Agenda (CDRL A006), |
Minutes (CDRL A008), Test Readiness Review (CDRL A090), and SOW 30 days prior to first GDT event
| LFT&E IPT Meeting |
| 3.5.1.8.2 |
| Government Facility |
| 1 day |
| N/A |
| 120 DAC and then monthly until completion of FUSL |
| Government Live Fire Test Readiness Review |
| 3.5.1.8.3 |
| Government Facility |
| 1 day |
| Documentation per SOW |
| 60 and 30 calendar days prior to the start of each Live Fire Event |
| Pre-Logistics Demonstration Planning Meeting |
| 3.5.3.1.3 |
| Government Facility |
| 1 day |
| Logistics Demonstration Support Plan (CDRL A103) |
| 150 days prior to the Logistics Demonstration |
| Logistics Program Management Meetings |
| 3.6.1 |
| Government Facility |
| 1 Day |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) One (1) Day After PAC, and One (1) Day after LRIP and FRP (Options if exercised)
| Logistics Program Management Meetings |
| 3.6.1 |
| Contractor Facility |
| 2 Days |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) 60 days after CLIN 1004 is exercised
| Provisioning Guidance Conference (PGC) |
| 3.6.4.2 |
| Contractor Facility |
| 1 day |
| Contractor’s Provisioning Requirements Statement (CDRL A093), Agenda (CDRL A006) & |
Minutes (CDRL A008) Two (2) Times:
60 Days after LRIP and 60 Days after FRP (Options, if exercised),
| Provisioning Technical Conference (PTCs) |
| 3.6.4.2 |
| Government Facility |
| 3 Days Each |
| Agenda (CDRL A006) & |
Minutes and Action Items (CDRL A008) Three (3) Times:
12 and 24 months after LRIP (Option, if exercised)
12 months after FRP (Option, if exercised)
| In-Process Review |
| 3.6.6.3 |
| Contractor’s Facility |
| No more than 2 days Each |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) Eight (8) Times:
7, 14, 21, and 28 months after Contract award
12 and 24 months after LRIP and FRP (Options, if exercised)
| Technical Manual Guidance Conference |
| 3.6.7.2 |
| Contractor’s Facility |
| 2 Days Each |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) Three (3) Times:
60 Days after CLIN 1004 is exercised
60 Days after LRIP and FRP (Options, if exercised)
Technical Manual In-Process Reviews (IPRs)
| 3.6.7.2 |
| Contractor’s Facility |
| 1 Day Each |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) Eight (8) Times:
16, and 24 months after Contract Award
8, 16, and 24 months after LRIP and FRP (Options, if exercised)
FOR PLANNING PURPOSES ONLY. To be finalized at Technical manual Guidance Conferences
| TDP Guidance Conference |
| Attachment 17 |
| Contractor’s Facility |
| No more than 2 days |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) One Time: 90 DAC of FRP Option 3 Execution
| TDP In-Process Review |
| Attachment 17 |
| Contractor’s Facility |
| No more than 5 days each – TBD at TDP Guidance Conference |
| Agenda (CDRL A006) & |
Minutes (CDRL A008) As Required to Complete TDP Review
ACV-SPE-02003 v0.X Page A-5
File details come from the government source that posted it. Updated .