S4-02_-_ENLARGED_PARTIAL_PLANS.pdf

PDF 123 KB Posted

Attached to
Restack of the William J. Green Federal Building
Solicitation number
GS-03-P-16-AZ-C-7004
Issued by

About this file

Drawing S4 02 Enlarged Partial Plans

View the file

Other files

File Type Posted
Amendment_0007.pdf PDF
Ta4.26_-_02_Enlarged_Plans_-_Conference_Room_05.pdf PDF
Amendment_0006.pdf PDF
Flow_Test.pdf PDF
23_0900_INSTRUMENTATION_AND_CONTROL_FOR_HVAC._-_Add__2.pdf PDF
Amendment_0005.pdf PDF
Specification_-_Table_of_Contents.pdf PDF
10_2240_Folding_Glass-Panel_Partitions.pdf PDF
MS-502.pdf PDF
09_5113_acoustical_panel_ceilings.pdf PDF
23_2113_HYDRONIC_PIPING_-_Add__2.pdf PDF
MP-405.pdf PDF
01_1030_TELECOMMUNICATIONS_SYSTEMS_OVERVIEW.pdf PDF
08_8713_Window_Film_Type_01.pdf PDF
01_ARCHITECTURAL_-_Addendum_02.pdf PDF
Addendum_No_02_-_Cover_Sheet.pdf PDF
09_3033_stone_tiling.pdf PDF
10_1423_Panel_Signage.pdf PDF
MD-124.pdf PDF
MP-103_2.pdf PDF
M-001.pdf PDF
09_6813_tile_carpeting.pdf PDF
S3-01_-_TYPICAL_DETAILS.pdf PDF
MP-104.pdf PDF
MS-501.pdf PDF
10_2226_Operable_Partitions.pdf PDF
MD-123.pdf PDF
08_8713_Window_Film_Type_02.pdf PDF
09_3000_ceramic_tile.pdf PDF
10_2241_Vertically_Folding_Panel_Doors.pdf PDF
MD103.pdf PDF
MD501.pdf PDF
Pre-Alteration_Asbestos_Assessment.pdf PDF
Specification_-_23_0529_HANGERS_AND_SUPPORTS_FOR_HVAC_PIPING_AND_EQUIPMENT-Addendum__1.pdf PDF
Ty6-00.pdf PDF
Specification_-_09_6513_RESILIENT_BASE_AND_ACCESSORIES.pdf PDF
Specification_-_01_1000_SUMMARY.pdf PDF
MH104.pdf PDF
Amendment_0004.pdf PDF
Construction_Sequencing_Diagrams.pdf PDF
Addendum_No_01_-_Cover_Sheet.pdf PDF
01_ARCHITECTURAL_-_Addendum_01.pdf PDF
MH103.pdf PDF
Specification_-_01_2400_OPTIONS.pdf PDF
Specification_-_Table_of_Contents.pdf PDF
Specification_-_09_5113_ACOUSTICAL_PANEL_CEILINGS.pdf PDF
MD104.pdf PDF
Amendment_0003.pdf PDF
Amendment_0002.pdf PDF
02_STRUCTURAL.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H

H

J

J

K

K

W24X84

W24X84

W

X

W

X

W12X40

W12X40

W

X

W

X

W

X

E X

IS

T

IN

G

W

X

E X

IS

T

IN

G

W

X

EXISTING

W24X104

EXISTING

W24X104

EXISTING

W8

EXISTING

W8

W8X31

1 1/2" x 3/16 STEEL BAR

GRATING WITH A 100 PSF

LIVE LOAD CAPACITY WITH

CROSS BARS AT 2"oc

STEEL STAIR BY STEEL

FABRICATOR

STEEL STAIR BY STEEL

FABRICATOR

1 1/2" x 3/16 STEEL BAR

GRATING WITH A 100 PSF

LIVE LOAD CAPACITY WITH

CROSS BARS AT 2"oc

NOTES: 1. TOP OF STEEL ELEVATION IS 5'-4" ABOVE EXISTING ROOF SLAB. STEEL ELEVATION TO MATCH EXISTING DUNNAGE. CONTRACTOR TO VERIFY IN FIELD PRIOR TO FABRICATION.

2. ALL EXTERIOR STEEL TO BE GALVANIZED.

© 2015 Erdy McHenry Architecture, LLC

DRAWN BY:

Erdy McHenry Architecture, LLC 915 North Orianna Street Philadelphia, Pennsylvania 19123 ph: 215.925.7000 fax: 215.925.1990 web: http://www.em-arc.com

Architect:

SCOTT A. ERDY, AIA

DAVID S. MCHENRY, AIA

emArchitecture

SCALE:

PROJECT NO:

DATE:

SHEET NUMBER:

P lo tte d:

GSA Building No.

GSA Project No.

GSA Contract No.

GSA Solicitation No.

S

E N

S

IT

IV

E

B U

T U

N C

L A

S S

IF

IE

D

S B

U

P

R O

P E

R T

Y O

F

T

H E

U N

IT

E

D S

T A

T E

S G

O V

E R

M E

N T

F o r o ff ic a l u s e o n ly

C o p y in g d is s e m in a ti o n o r d is tr ib u ti o n o f th is d o c u m e n t to u n a u th ri z e d r e c ip ie n ts i s p ro h ib it e d D o n o t re m o v e t h is n o ti c e

P ro p e rl y d e s tr o y o r re tu rn d o c u m e n ts w h e n n o l o n g e r n e e d e d

PA0277

VPA00027

GS-03P-15-AZ-C-1020

GS-03P-14-AZ-C-0020

1/4" = 1'-0"

S4.02

ENLARGED

PARTIAL

PLANS

1158.00Author

03/28/16

CONSOLIDATION PROJECT

GREEN FEDERAL BUILDING

190 Witherspoon Street Princeton, PA 19106

Studi Hillier 190 Witherspoon Street Princeton, NJ 08542

Program + Strategy Consultant

Greenman - Peterson, Inc. (GPI) 50 Glenmaura National BLVD.

Suite 12 Scranton, PA 18505

MEP Engineer

Antis Veterans Engineering and Technical Services 2074 Cobblestone Lane Reston, VA 20191

Structural Engineer

TCT Cost Consultants, LLC 1090 Vermont Avenue NW Suit 230 Wahington, DC 20005

Cost Specialist

Praxis Building Solutions. LLC 2401 Walnut Street Suite 102 Philadelphia, PA 19103

Green Building Consultant

Beam, Ltd 428 West Waverly Road Glenside, PA 19038

Lighting Consultant

Cerami & Associates 404 Fifth Avenue New York, NY 10018

Acoustical Consultant

Weidlinger Associates 1825 K Street Avenue NW Suite 350 Washington, DC 2006

Security + Blast

Drawing Issue Date Issued for Core & Shell Package 05-06-16

Addendum #1 06-10-16

Scale: 1/4" = 1'-0"1

ROOF DUNNAGE EXPANSION

File details come from the government source that posted it. Updated .