M-001.pdf

PDF 125 KB Posted

Attached to
Restack of the William J. Green Federal Building
Solicitation number
GS-03-P-16-AZ-C-7004
Issued by

About this file

Drawing m-001

View the file

Other files

File Type Posted
Amendment_0007.pdf PDF
Ta4.26_-_02_Enlarged_Plans_-_Conference_Room_05.pdf PDF
Amendment_0006.pdf PDF
Flow_Test.pdf PDF
23_0900_INSTRUMENTATION_AND_CONTROL_FOR_HVAC._-_Add__2.pdf PDF
S4-02_-_ENLARGED_PARTIAL_PLANS.pdf PDF
Amendment_0005.pdf PDF
Specification_-_Table_of_Contents.pdf PDF
10_2240_Folding_Glass-Panel_Partitions.pdf PDF
MS-502.pdf PDF
09_5113_acoustical_panel_ceilings.pdf PDF
23_2113_HYDRONIC_PIPING_-_Add__2.pdf PDF
MP-405.pdf PDF
01_1030_TELECOMMUNICATIONS_SYSTEMS_OVERVIEW.pdf PDF
08_8713_Window_Film_Type_01.pdf PDF
01_ARCHITECTURAL_-_Addendum_02.pdf PDF
Addendum_No_02_-_Cover_Sheet.pdf PDF
09_3033_stone_tiling.pdf PDF
10_1423_Panel_Signage.pdf PDF
MD-124.pdf PDF
MP-103_2.pdf PDF
09_6813_tile_carpeting.pdf PDF
S3-01_-_TYPICAL_DETAILS.pdf PDF
MP-104.pdf PDF
MS-501.pdf PDF
10_2226_Operable_Partitions.pdf PDF
MD-123.pdf PDF
08_8713_Window_Film_Type_02.pdf PDF
09_3000_ceramic_tile.pdf PDF
10_2241_Vertically_Folding_Panel_Doors.pdf PDF
MD103.pdf PDF
MD501.pdf PDF
Pre-Alteration_Asbestos_Assessment.pdf PDF
Specification_-_23_0529_HANGERS_AND_SUPPORTS_FOR_HVAC_PIPING_AND_EQUIPMENT-Addendum__1.pdf PDF
Ty6-00.pdf PDF
Specification_-_09_6513_RESILIENT_BASE_AND_ACCESSORIES.pdf PDF
Specification_-_01_1000_SUMMARY.pdf PDF
MH104.pdf PDF
Amendment_0004.pdf PDF
Construction_Sequencing_Diagrams.pdf PDF
Addendum_No_01_-_Cover_Sheet.pdf PDF
01_ARCHITECTURAL_-_Addendum_01.pdf PDF
MH103.pdf PDF
Specification_-_01_2400_OPTIONS.pdf PDF
Specification_-_Table_of_Contents.pdf PDF
Specification_-_09_5113_ACOUSTICAL_PANEL_CEILINGS.pdf PDF
MD104.pdf PDF
Amendment_0003.pdf PDF
Amendment_0002.pdf PDF
02_STRUCTURAL.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DUCTWORK SYMBOLS

MISCELLANEOUS

SUPPLY DIFFUSER 1-WAY BLOW

SUPPLY DIFFUSER 2-WAY BLOW

SUPPLY DIFFUSER 3-WAY BLOW

SUPPLY DIFFUSER 4-WAY BLOW

SUPPLY DUCT (SECTION)

RETURN, EXHAUST, OR TRANSFER

DUCT (SECTION)

EXHAUST DUCT (SECTION)

DRAWING SYMBOLS

DETAIL DESIGNATION OR ENLARGED PLAN

X

X HVAC DRAWING NUMBER WHERE DETAIL IS SHOWN

X

XX

SECTION DESIGNATION

HVAC DRAWING NUMBER WHERE SECTION IS SHOWN

HVAC DRAWING NUMBER WHERE TAKEN FROM

X X

EQUIPMENT TAG

TAG NUMBER

FIN RADIATION

FIN LENGTH

FIN RADIATION TAG NUMBER

FR

XX

POINT OF NEW CONNECTION

POINT OF DISCONNECTION

X-X

T

S

THERMOSTAT

TEMPERATURE SENSOR

XXX

GRILLE/REGISTER/DIFFUSER

GRILLE/REGISTER/DIFFUSER TAG

GRILLE/REGISTER/DIFFUSER NUMBER

BALANCING CFM

AIR FLOW DIRECTION

UNIT HEATER UH

X

DUCTWORK SYMBOLS

DOUBLE LINE SINGLE LINE

DUCT WIDTH x DEPTH

ACOUSTICAL DUCT LINING

AC ALTERNATING CURRENT

ACC AIR COOLED CONDENSER

ACU AIR CONDITIONING UNIT

AD ACCESS DOOR

ADJ ADJUSTABLE

AF AIR FOIL

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFR ABOVE FINISHED ROOF

AFS AIR FLOW STATION

AHU AIR HANDLING UNIT

AP ACCESS PANEL

ARCH ARCHITECTURE

ATC AUTOMATIC TEMPURATURE CONTROL

ATM ATMOSPHERE

AUX AUXILIARY

AVG AVERAGE

AWG AMERICAN WIRE GAUGE

B BOILER

BB BASEBOARD

BC BACKWARD CURVE

BDD BACKDRAFT DAMPER

BF BOILER FEED

BHP BRAKE HORSEPOWER

BI BACKWARD INCLINED

BOD BOTTOM OF DUCT

BOJ BOTTOM OF JOIST

BOS BOTTOM OF STEEL

BTU BRITISH THERMAL UNIT

BTUH BTU PER HOUR

C CONVECTOR

CAV CONSTANT AIR VOLUME

CC COOLING COIL

CCW COUNTER CLOCKWISE

CFM CUBIC FEET PER MINUTE

CH CHILLER

C&I CONTROLS AND INSTRUMENTATION

CLG CEILING

CMU CONCRETE MASONARY UNIT

COND CONDENSATE

CONN CONNECTION

CONT CONTINUATION

CORR CORRIDOR

CT COOLING TOWER

CU CONDENSING UNIT

CUH CABINET UNIT HEATER

CV CONTROL VALVE

CU FT CUBIC FEET

CVS CONTROL VALVE STATION

CVT CONVERTER

CW CLOCKWISE

D DIFFUSER OR REGISTER

dB DECIBEL, RE 10 WATT

DBT DRY BULB TEMPURATURE (°F)

DDC DIRECT DIGITAL CONTROL

DEG DEGREE FAHRENHEIT (°F)

DIA DIAMETER

DIM DIMENSION

DN DOWN

DP DEW POINT TEMPURATURE (°F)

DX DIRECT EXPANSION

DWG DRAWING

E EXHAUST

EA EXHAUST AIR

EAT ENTERING AIR TEMPURATURE (°F)

EC ELECTRICAL CONTRACTOR

EDH ELECTRICAL DUCT HEATER

EDR EQUIVALENT DIRECT RADIATION

EER ENERGY EFFICIENCY RATIO

EF EXHAUST FAN

EFF EFFICIENCY

ELEV ELEVATION

EMS ENERGY MANAGEMENT SYSTEM

ERU ENERGY RECOVERY UNIT

ESP EXTERNAL STATIC PRESSURE

ET EXPANSION TANK

EWT ENTERING WATER TEMPURATURE (°F)

F FILTER

F&T FLOAT AND THERMOSTATIC

FA FACE AREA

FC FORWARD CURVE

FCU FAN COIL UNIT

FLR FLOOR

FP FIRE PROTECTION

FPM FEET PER MINUTE

FR FINNED RADATION

FRP FIBERGLASS REINFORCED POLYMER

FT FEET

FVEL FACE VELOCITY

GA GAUGE OR GAGE

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GH GRAVITY HOOD

GPD GALLONS PER DAY

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

H HUMIDIFIER

HC HEATING COIL

HG MERCURY

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HR HOUR

HVU HEATING AND VENTILATION UNIT

HX HEAT EXCHANGER

IB INVERTED BUCKET

ID INSIDE DIAMETER

IFB INTEGRAL FACE AND BYPASS

IGV INLET GUIDE VANES

IN INCH

IPS IRON PIPE SIZE

IU INDUCTION UNIT

KW KIOWATTS

KWH KILOWATT HOUR

LAT LEAVING AIR TEMPURATURE (°F)

LBS POUNDS

LCP LOCAL CONTROL PANEL

LD LINEAR DIFFUSER

LF LINEAR FEET

LWT LEAVING WATER TEMPURATURE (°F)

M MOTOR OPERATED

MAU MAKEUP AIR UNIT

MAX MAXIMUM

MB MIXING BOX

MBH 1000 BTUH

MC MECHANICAL CONTRACTOR

MCC MOTOR CONTROL CENTER

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MMBH 1,000,000 BTUH

NA NOT APPLICABLE

NC NOISE CRITERIA, dB RE 20 uPa

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NPS NOMINAL PIPE SIZE

NPT NOMINAL PIPE THREAD

NTS NOT TO SCALE

OA OUTSIDE AIR

OAD OUTSIDE AIR DAMPER

OBD OPPOSED BLADE DAMPER

OD OUTSIDE DIAMETER

OZ OUNCE

P PUMP

PBD PARALLEL BLADE DAMPER

PC PLUMBING CONTRACTOR

PD PRESSURE DROP

PDI PRESSURE DIFFERENTIAL INDICATOR

PDV PRESSURE DIFFERENTIAL VALVE

PH PHASE

PHC PREHEAT COIL

PPM PART PER MILLION

PROP PROPELLER

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIA PSI, ABSOLUTE

PSIATM PSI, ATMOSPHERE

PSIG PSI, GAUGE

QTY QUANTITY

R REGISTER

RA RETURN AIR

RC ROOM CRITERIA, dB RE 20 uPa

RF RETURN/RELIEF AIR FAN

RH RELATIVE HUMIDITY

RHC REHEAT COIL

RPM REVOLUTIONS PER MINUTE

S SMOKE DETECTOR

SA SUPPLY AIR

SAF SUPPLY AIR FAN

SC SENSIBLE COOLER

SCFM CFM, STANDARD CONDITIONS

SEER SEASONAL ENERGY EFFICIENY RATIO

SENS SENSIBLE

SF SQUARE FEET

SP STATIC PRESSURE (IN.WG.)

SPEC SPECIFICATION

SPS STATIC PRESSURE SENSOR

SQ SQUARE

STD STANDARD

SS STAINLESS STEEL

SV SOLENOID VALVE

T THERMOSTAT

TA TRANSFER AIR

TD TEMPURATURE DIFFERENCE (°F)

TEMP TEMPURATURE

TG TRANSFER GRILL

TOD TOP OF DUCT

TOP TOP OF PIPE

TOS TOP OF STEEL

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

TYP TYPICAL

UC UNDERCUT

UH UNIT HEATER

UL UNDERWRITERS LABORATORY

UV UNIT VENTILATOR

V VALVE

VA VOLD-AMPERE

VAV VARIABLE AIR VOLUME

VAVR VAV, WITH REHEAT

VD VOLUME DAMPER

VEL VELOCITY

VFD VARIABLE FREQUENCY DRIVE

VFV VAV, WITH FAN VOL VOLUME

VP VACUUM PUMP

VVT VARIABLE VOLUME VARIBLE TEMPURATURE

W WATT

WB WET BULB TEMPURATURE (°F)

WC WATER COLUMN

WG WATER GAUGE

WMS WIRE MESH SCREEN

WSHP WATER SOURCE HEAT PUMP

W/ WITH

MECHANICAL ABBREVIATIONS PIPING SYMBOLS

GENERAL

(NAME) E

(NAME)

EXISTING PIPE

ROUND DUCT

INCLINED RISE, IN DIRECTION

OF AIR FLOWR

R

D D

INCLINED DROP, IN DIRECTION

OF AIR FLOW

FLEXIBLE DUCT CONNECTION

ELBOW WITH TURNING VANES

STANDARD RADIUS ELBOW

DAMPER IN WALL

OR FLOORX

SUPPLY REGISTER, DIFFUSER,

OR GRILLE (WALL TYPE)

RETURN GRILLE/REGISTER

RUNOUT TO ROUND SUPPLY

DIFFUSER

RUNOUT TO SQUARE SUPPLY

DIFFUSER

BOD

BOD

BACKDRAFT DAMPER

DUCT HEATING COIL

ELECTRIC DUCT HEATING COIL

WITH CONTROL BOX

MOTOR OPERATED DAMPER

M M

MANUAL VOLUME DAMPER

VD

VD

S

S

SMOKE DETECTOR FURNISHED

AND WIRED BY THE E.C.,

INSTALLED BY THE M.C

X

F

S

FS

FIRE

SMOKE

FIRE/SMOKE

EXISTING PIPE TO BE REMOVED

DIRECTION OF FLOW

HEATING

A

ATV

COMPRESSED AIR

ATMOSPHERIC VENT

BOILER BLOW DOWNBBD

FOD

FOG

FOR

FOS

FOV

FUEL OIL DISCHARGE

FUEL OIL GAUGE

FUEL OIL RETURN

FUEL OIL SUCTION

FUEL OIL TANK VENT

PC

VPD

MU

VAC

HWS HOT WATER SUPPLY

VACUUM AIR

MAKE-UP WATER (COLD WATER FILL)

VACUUM PUMP DISCHARGE

PUMPED CONDENSATE

HWR

MTWS

MTWR

HOT WATER RETURN

MEDIUM TEMPURATURE HOT WATER SUPPLY

MEDIUM TEMPURATURE HOT WATER RETURN

HPS

MPS

LPS

HPC

MPC

LPC

HIGH PRESSURE STEAM

MEDIUM PRESSURE STEAM

LOW PRESSURE STEAM

HIGH PRESSURE CONDENSATE

MEDIUM PRESSURE CONDENSATE

LOW PRESSURE CONDENSATE

AIR CONDITIONING & REFRIGERATION

BS

BR

CS

CR

CHS

CHR

D

FILL

HPWS

HPWR

RL

RS

BRINE SUPPLY

BRINE RETURN

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

CHILLED WATER SUPPLY (FAN COIL AND AIR HANDLING UNITS)

CHILLED WATER RETURN (FAN COIL AND AIR HANDLING UNITS)

DRAIN LINE

FILL LINE

HEAT PUMP WATER SUPPLY

HEAT PUMP WATER RETURN

REFRIGERANT LIQUID

REFRIGERANT SUCTION

SYSTEM SPECIALTIES

TRAP, FLOAT

TRAP, THERMOSTATIC

TRAP, FLOAT & THERMOSTATIC

TRAP, INVERTED BUCKET

RS

T

VALVES

BALL

BUTTERFLY

GATE

GLOBE

PLUG

CALIBRATED BALANCE/FLOW MEASURE

CHECK VALVE (ARROW INDICATED DIRECTION

OF FLOW)

RELIEF (R) OR SAFETY (S)

PRESSURE REDUCING

DRAIN VALVE W/ HOSE CONNECTION

AND SEAL CAP

ATC, TWO-WAY

SOLENOID

ATC, THREE-WAY

REFRIGERANT EXPANSION, AUTOMATIC

REFRIGERANT EXPANSION, MANUAL

REFRIGERANY EXPANSION,

ELECTRIC

FLOW CONTROL VALVE

(A=AUTOMATIC, M= MANUAL)

S

M

F A

PIPING SYMBOLS

PIPING SPECIALTIES & FITTINGS

ANCHOR

PIPE GUIDES

FLEXIBLE CONNECTION

FINNED RADIATION

MANUAL AIR VENT

CONCENTRIC REDUCER OR INCREASER

AUTOMATIC AIR VENT

ECCENTRIC REDUCER OR INCREASER

TOP CONNECTION, 45 DEG OR 90 DEG

BOTTOM CONNECTION, 45 DEG OR 90 DEG

SIDE CONNECTION OR TEE FITTING

CAPPED OUTLET

CHANGE IN ELEVATION OF PIPE

PIPE RISE OR ELBOW TURNED UP

PIPE DROP OR ELBOW TURNED DOWN

UNION OR FLANGE

STRAINER

STRAINER W/ BLOWDOWN AND HOSE END CONNECTION

THERMOMETER

PRESSURE GAUGE

THERMOMETER WELL

NEEDLE VALVE

FLOW SWITCH

PRESSURE SWITCH

WATER FLOW MEASURING DEVICE

TEST/PLUG

PUMP

SIGHT GLASS

BLIND FLANGE

HOSE END CONNECTION

AV

FS

PS

P/T

1. CODES AND STANDARDS LISTED IN SPECIFICATIONS AND DRAWINGS ARE MINIMUM STANDARDS. WHERE REQUIREMENTS ON THE DRAWINGS OR SPECIFICATIONS EXCEED THE MINIMUM CODE REQUIREMENTS, THE DRAWINGS OR SPECIFICATIONS SHALL GOVERN.

2. THE POWER RATING OF MOTORS AND OTHER MECHANICAL EQUIPMENT AND THE ELECTRICAL CHARACTERISTICS OF ELECTRICAL SYSTEMS SERVING THEM HAVE BEEN ESTABLISHED AS MINIMUMS WHICH ALLOW THAT EQUIPMENT TO FUNCTION PROPERLY TO PRODUCE THE REQUIRED CAPACITIES. POWER RATINGS INCLUDE REASONABLE SAFETY FACTORS TO ACCOMMODATE COMMON DIFFERENCES BETWEEN DESIGN PARAMETERS AND FIELD CONSTRUCTION PRACTICES. EQUIPMENT WITH POWER RATINGS LESS

THAN THOSE INDICATED ON THE DRAWINGS SHALL NOT BE PERMITTED.

3. REASONABLE EFFORTS HAVE BEEN MADE TO COORDINATE ELECTRICAL REQUIREMENTS OF MECHANICAL EQUIPMENT WITH THE ELECTRICAL SYSTEMS SERVING THAT EQUIPMENT. DIFFERENCES AMONG MANUFACTURERS OF MECHANICAL EQUIPMENT MAKE IT IMPOSSIBLE TO PRODUCE A SINGLE ELECTRICAL DESIGN WHICH WILL SATISFY THE VARYING ELECTRICAL REQUIREMENTS OF THE THOSE MANUFACTURERS. CONSEQUENTLY, THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL REQUIREMENTS OF THE MECHANICAL EQUIPMENT ACTUALLY FURNISHED ON THIS PROJECT WITH THE EQUIPMENT ACTUALLY FURNISHED ON THIS PROJECT AND PROVIDE ELECTRICAL SYSTEMS REQUIRED BY THAT EQUIPMENT. THIS COORDINATION EFFORT SHALL BE COMPLETED PRIOR TO THE INSTALLATION OF EITHER THE MECHANICAL EQUIPMENT OR THE ELECTRICAL SYSTEMS SERVING THAT EQUIPMENT.

ELECTRICAL SYSTEM REVISIONS REQUIRED TO COORDINATE WITH THE MECHANICAL EQUIPMENT ACTUALLY FURNISHED SHALL BE

PROVIDED AT NO ADDITIONAL COST TO THE OWNER.

4. DRAWINGS INDICATE GENERAL LOCATIONS OF FIXTURES, APPARATUS, EQUIPMENT, PIPING, AND DUCTWORK. CHANGES ON LOCATION SHALL BE MADE TO ACCOMMODATE EXISTING OR NEW BUILDING CONDITIONS AND COORDINATION WITH OTHER TRADES, INCLUDING HVAC, PLUMBING, ELECTRICAL, FIRE PROTECTION, STRUCTURAL, AND ARCHITECTURAL, SHALL BE MADE WITHOUT

ADDITIONAL COST TO THE OWNER.

5. PROVIDE ACCESS TO EQUIPMENT AND PORTIONS OF BUILDING SYSTEMS REQUIRING SERVICE.

6. DO NOT INSTALL DUCTWORK, PIPING, OR EQUIPMENT IN ELECTRICAL ROOMS, ELEVATOR ROOMS, OR ELEVATOR SHAFTS, UNLESS EXPLICITLY INDICATED ON THE DRAWINGS. PIPING, DUCTWORK, AND EQUIPMENT (SWITCHGEAR, SWITCHBOARDS, PANELS, MOTOR CONTROL CENTERS, VARIABLE FREQUENCY DRIVES, TRANSFORMERS, OR STARTERS) SHALL NOT BE INSTALLED DIRECTLY ABOVE

OR 42" IN FRONT OF ELECTRICAL EQUIPMENT FROM THE FLOOR TO THE STRUCTURE ABOVE.

7. FOR RENOVATION PROJECTS WHERE THE BUILDING IS OCCUPIED, SCHEDULE WORK SO EXISTING SYSTEMS WILL BE INTERRUPTED FOR A MINIMUM AMOUNT OF TIME. OBTAIN APPROVAL FROM THE OWNER AND ARCHITECT AT LEAST 14 DAYS PRIOR TO INTERRUPTION OR CONNECTION. NO ALLOWANCE WILL BE MADE FOR LACK OF KNOWLEDGE OF EXISTING CONDITIONS.

8. UNLESS INDICATED OTHERWISE, EQUIPMENT AND MATERIALS SHALL BE NEW AND OF THE CUSTOMARY STANDARD AND QUALITY

FURNISHED BY THE DESIGNATED MANUFACTURER FOR THAT CATALOG NUMBER.

9. FOR EXISTING SYSTEMS, REMOVE EXPOSED PIPING AND DUCTWORK RENDERED USELESS DUE TO CHANGES. PLUG OUTLETS IN

PIPING. CAP AND SEAL OPENINGS IN DUCTWORK AND SEAL AIRTIGHT.

10. AIR SYSTEMS SHALL OPERATE WITHOUT AERODYNAMIC NOISE GENERATED FROM FAULTY INSTALLATION OF DUCTWORK, DIFFUSERS, OR ANY PORTION OF THE AIR DISTRIBUTION SYSTEM.

11. SUPPORT PIPING INDEPENDENTLY OF EQUIPMENT. HANGER RODS SHALL BE SUSPENDED FROM THE STRUCTURE. DO NOT SUSPEND

FROM OTHER PIPING, CONDUIT, EQUIPMENT, OR DUCTWORK.

12. ALL WORK REFERENCED UNDER DIVISION 23 SHALL BE DONE BY THE MECHANICAL CONTRACTOR.

GENERAL MECHANICAL NOTES:

1. INSTALL PIPING TO ALLOW ACCESS FOR VALVES, AIR

VENTS, AND EQUIPMENT REQUIRING ACCESSIBILITY, AND

TO PROVIDE MAXIMUM HEADROOM.

2. PROVIDE OFFSETS TO MAINTAIN CEILING HEIGHT AND TO

COORDINATE WITH OTHER TRADES.

3. INSTALL VALVES IN HORIZONTAL PIPING WITH VALVE

STEMS AT OR ABOVE THE PIPE CENTERLINE.

4. ARRANGE PIPING FOR VENTING OF AIR AND DRAINAGE OF

ENTIRE SYSTEM.

5. REPLACE EXISTING MECHANICAL PIPE HANGERS AND

PIPE FLOOR SUPPORTS WITH NEW TO SERVE EXISTING

MECHANICAL PIPING TO REMAIN IN ORDER TO

ACCOMMODATE THE INSTALLATIONOF ALL NEW

EQUIPMENT, SYSTEMS, AND DEVICES. MECHANICAL

CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND

SIZES IN THE FIELD.

6. WHEREVER NEW PIPING IS JOINED TO EXISTING PIPING,

THE MECHANICAL CONTRACTOR SHALL PROPERLY SEAL

THESE CONNECTIONS WATERTIGHT AND INSULATE THESE

LOCATIONS WITH NEW INSULATION AS INDICATED IN THE

SPECIFICATION.

7. FOR COPPER AND STEEL PIPING GROOVED OR

MECHANICALLY FORMED T-TYPE FITTINGS ARE NOT

ACCEPTABLE.

8. LUBRICATE, EXERCISE, CLEAN AND TEST ALL EXISTING

VALVES AND STRAINERS FOR THE HEATING PLANT,

COOLING PLANT (CHILLED WATER AND CONDENSER

WATER), PIPE RISER TAKE-OFFS, 10TH FLOOR PUMP

ROOM, AND PIPE MAIN SHUTOFFS PER THE

MANUFACTURER'S INSTRUCTIONS.

1. CHANGES IN SHAPE OR DIMENSION SHALL BE MADE WITH

MAXIMUM TRANSITION OF 1 TO 7.

2. SEPARATE GALVANIZED SHEET METAL FROM ALUMINUM OR

COPPER PER THE SPECIFICATIONS.

3. PROVIDE SUPPLEMENTAL STIFFENING AND SUPPORTS TO

DUCTS AND APPARATUS CASINGS TO PREVENT DRUMMING,

SAGGING AND TO PROVIDE A STRUCTURALLY SOUND ASSEMBLY.

4. PROVIDE OFFSETS AND TRANSITIONS TO COORDINATE WITH

OTHER TRADES.

5. PROVIDE DUCTWORK AND TRANSITIONS TO CONNECT DUCTWORK TO

NEW OR EXISTING EQUIPMENT, DUCTWORK, AND COILS.

6. INSTALL FLEXIBLE PERMANENT DUCTWORK IN A FULLY EXTENDED

CONDITION WITHOUT SAGS AND KINKS.

7. MECHANICAL CONTRACTOR SHALL INSTALL DUCT MOUNTED SMOKE

DETECTORS IN ACCESSIBLE LOCATIONS. DETECTORS SHALL BE

FURNISHED AND WIRED BY THE ELECTRICAL CONTRACTOR. REFER

TO ELECTRICAL DRAWINGS FOR EXACT QUANTITY AND LOCATIONS.

8. INDICATED DIMENSIONS DENOTE FREE AND CLEAR INSIDE

DIMENSIONS.

9. REPLACE EXISTING DUCT HANGERS WITH NEW TO SERVE EXISTING

DUCTWORK TO REMAIN IN ORDER TO ACCOMMODATE THE

INSTALLATION OF ALL NEW EQUIPMENT, SYSTEMS, AND DEVICES.

MECHANICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS

AND SIZES IN THE FIELD.

10. WHEREVER NEW DUCTWORK IS JOINED TO EXISTING DUCTWORK,

THE MECHANICAL CONTRACTOR SHALL PROPERLY SEAL THESE

CONNECTIONS AIRTIGHT AND INSULATE THESE LOCATIONS WITH NEW

INSULATION AS INDICATED IN THE SPECIFICATION.

GENERAL PIPING NOTES: GENERAL DUCTWORK NOTES:

1. TRANSFORMERS OR FILTERS FOR OPERATION OF AUTOMATIC TEMPERATURE CONTROLS FROM BUILDING POWER

CIRCUITS SHALL BE PROVIDED UNDER DIVISION 23.

2. LOW VOLTAGE WIRING (LOWER THAN 110 VOLTS) FOR INTERLOCKED DEVICES, DDC CONTROLLERS, TERMINAL CONTROL UNITS, FLOW MEASURING DEVICES, AND OTHER POWER CONSUMING CONTROL DEVICES SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. ALL LOW VOLTAGE WIRING SHALL BE INSTALLED IN

A CONDUIT AND SHALL BE PLENUM RATED.

3. WIRING 110 VOLTS AND HIGHER FOR INTERLOCKED DEVICES, DDC CONTROLLERS, TERMINAL CONTROL UNITS, FLOW MEASURING DEVICES, AND OTHER POWER CONSUMING CONTROL DEVICES SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR WITH DIVISION 26 REQUIREMENTS. COORDINATE WITH THE ELECTRICAL

CONTRACTOR.

4. BRANCH CIRCUIT WIRING AND CONDUIT FURNISHED FOR CONTROL EQUIPMENT POWER SHALL BE SEPARATE FROM OTHER POWER WIRING. EACH CIRCUIT SHALL EXTEND TO A 120V BRANCH CIRCUIT PANEL, AND IDENTIFIED 120V, 20 AMPERE, SINGLE POLE BRANCH CIRCUIT BREAKER FURNISHED IN THE PANEL TO SERVE THE CIRCUIT. NO MORE THAN 2 DDC CONTROLLER INSTALLATIONS SHALL OPERATE FROM A SINGLE 120V BRANCH CIRCUIT, UNLESS

INDICATED OTHERWISE.

5. WHERE SYSTEMS ARE SERVED BY EMERGENCY POWER, CONTROLS FOR OPERATION OF THOSE SYSTEMS SHALL

ALSO BE SERVED BY EMERGENCY POWER.

6. WHERE DAMPERS PREVENT AIRFLOW THROUGH AN AIR HANDLING UNIT OR FAN, THOSE DAMPERS SHALL BE PROVEN OPEN PRIOR TO STARTING THE UNIT OR FAN. PROOF SHALL BE BY MECHANICAL SAFETY LIMIT SWITCH ACTIVATED BY THE DAMPER BLADE. FOR SERVICE WITH VARIABLE FREQUENCY DRIVES THE SWITCH SHALL BE WIRED IN THE AUTOMATIC AND HAND/TEST POSITIONS AND IN THE BYPASS POSITION FOR VARIABLE FREQUENCY DRIVES WITH

BYPASS.

7. ALL AIR PIPING OR TUBING SHALL BE PLENUM RATED. MECHANICAL CONTRACTOR SHALL FURNISH ALL AIR PIPING

AND TUBING REQUIRED FOR AUTOMATIC CONTROLS SYSTEMS.

8. PROVIDE SUPPLEMENTAL STIFFENING AND SUPPORTS TO DUCTS AND APPARATUS CASINGS TO PREVENT

DRUMMING, SAGGING AND TO PROVIDE A STRUCTURALLY SOUND ASSEMBLY.

GENERAL AUTOMATIC TEMPERATURE CONTROL

NOTES:

VAV BOX

FAN COIL UNIT

LINEAR DIFFUSER

BLOWER COIL

FAN POWERED BOX

FCU

X

VAV

X

BC

X

FPB

X

CHS-P

CHR-P

CHILLED WATER SUPPLY - PRIMARY LOOP

CHILLED WATER RETURN - PRIMARY LOOP

N

(SBU)

SENSITIVE BUT UNCLASSIFIED

PROPERTY OF THE UNITED

STATES GOVERNMENT, COPYING,

DISSEMINATION, OR

DISTRIBUTION OF THIS

DOCUMENT TO UNAUTHORIZED

RECIPIENTS IS PROHIBITED.

Do not Remove this Notice.

Properly Destroy or return documents when no longer needed.

WEST EAST

© 2015 Erdy McHenry Architecture, LLC

DRAWN BY:

Erdy McHenry Architecture, LLC 915 North Orianna Street Philadelphia, Pennsylvania 19123 ph: 215.925.7000 fax: 215.925.1990 web: http://www.em-arc.com

Architect: SCOTT A. ERDY, AIA

DAVID S. MCHENRY, AIA

emArchitecture

SCALE:

PROJECT NO:

DATE:

SHEET NUMBER:

P lo tte d:

KEY PLAN

As indicated

M001

MECHANICAL LEGEND

1158.00/SCR-2015216.00DLA

05-06-16

600 Arch Street

Philadelphia, PA 19107

GREEN FEDERAL BUILDING

CONSOLIDATION

Program + Strategy Consultant Studio Hillier 190 Witherspoon Street Princeton, NJ 08542

Greenman - Pedersen, Inc. (GPI) 50 Glenmaura National Blvd.

Suite 102 Scranton, PA 18505

Cerami & Associates 404 Fifth Avenue New York, NY 10018

TCT Cost Consultants, LLC 1090 Vermont Avenue NW Suite 230 Washington, DC 20005

Weidlinger Associates, INC 1825 K Street Avenue NW Suite 350 Washington, DC 20006

Antis Veterans Engineering adn Technical Services 2074 Cobblestone Lane Suite 850 Reston, VA 20191

Structural Engineer

MEP Engineer

Acoustical Consultant

Cost Specialist

Security + Blast

Praxis Building Solutions, LLC 2401 Walnut Street Suite 102 Philadelphia, PA 19103

Green Building Consultant

Beam, Ltd 428 West Waverly Road Glenside, PA 19038

Lighting Consultant

GSA Project Data William J. Green Federal Building GSA Project #: VPA00027 GSA Building #: PA0277 GSA Contract #: GS-03P-14-AZ-C-0020 GSA Solicitation #: GS-03P-15-AZ-C-1020

Core & Shell Package 05-06-16

Revision Number Drawing Issue Date

1 Issued for Addendum 02 06-10-16

Sheets
M001 - MECHANICAL LEGEND

File details come from the government source that posted it. Updated .