H
H
J
J
K
K
L
L
M
M
G
G
EXISTING AIR
HANDLING
UNIT
AHU-74
EXISTING TOILET ROOM
EXHAUST SYSTEM TO REMAIN.
PROVIDE NEW VAV BOXES,
EXHAUST AIR REGISTERS WITH
VOLUME DAMPERS, AND
BALANCE AIR SYSTEM.
EXISTING TOILET ROOM
EXHAUST SYSTEM TO REMAIN.
PROVIDE NEW VAV BOXES,
EXHAUST AIR REGISTERS WITH
VOLUME DAMPERS, AND
BALANCE AIR SYSTEM.
REWORK EXISTING AIR
HANDLING UNIT RETURN AND
OUTSIDE AIR DUCTWORK AS
ILLUSTRATED IN THE 7TH
FLOOR CORE AHU
MECHANICAL ROOMS ON THE
DEMOLITION AND NEW
ENLARGED PLANS. (TYP.)
NOT IN CONTRACT, UNLESS OTHERWISE NOTED
TENANT IMPROVEMENT - REFER TO LEVEL 7
AS TYPICAL, UNLESS OTHERWISE NOTED
CORE AND SHELL - REFER TO LEVEL 7 AS
TYPICAL, UNLESS OTHERWISE NOTED
N
PROPERTY OF THE UNITED
STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice.
Properly destroy or return documents when no longer needed.
(SBU)
SENSITIVE BUT UNCLASSIFIED
EAST
© 2015 Erdy McHenry Architecture, LLC
DRAWN BY:
Erdy McHenry Architecture, LLC 915 North Orianna Street Philadelphia, Pennsylvania 19123 ph: 215.925.7000 fax: 215.925.1990 web: http://www.em-arc.com
Architect: SCOTT A. ERDY, AIA
DAVID S. MCHENRY, AIA
emArchitecture
SCALE:
PROJECT NO:
DATE:
SHEET NUMBER:
P lo tte d:
KEY PLAN
As indicated
MD104
DEMOLITION LEVEL 2
HVAC FLOOR PLAN -
EAST
1158.00/SCR-2015216.00DLA
05-06-16
600 Arch Street
Philadelphia, PA 19107
GREEN FEDERAL BUILDING
CONSOLIDATION
Program + Strategy Consultant Studio Hillier 190 Witherspoon Street Princeton, NJ 08542
Greenman - Pedersen, Inc. (GPI) 50 Glenmaura National Blvd.
Suite 102 Scranton, PA 18505
Cerami & Associates 404 Fifth Avenue New York, NY 10018
TCT Cost Consultants, LLC 1090 Vermont Avenue NW Suite 230 Washington, DC 20005
Weidlinger Associates, INC 1825 K Street Avenue NW Suite 350 Washington, DC 20006
Antis Veterans Engineering adn Technical Services 2074 Cobblestone Lane Suite 850 Reston, VA 20191
Structural Engineer
MEP Engineer
Acoustical Consultant
Cost Specialist
Security + Blast
Praxis Building Solutions, LLC 2401 Walnut Street Suite 102 Philadelphia, PA 19103
Green Building Consultant
Beam, Ltd 428 West Waverly Road Glenside, PA 19038
Lighting Consultant
GSA Project Data William J. Green Federal Building GSA Project #: VPA00027 GSA Building #: PA0277 GSA Contract #: GS-03P-14-AZ-C-0020 GSA Solicitation #: GS-03P-15-AZ-C-1020
Core & Shell Package 05-06-16
Scale: 1/8" = 1'-0"1 LEVEL 2 - HVAC DUCTWORK DEMO - EAST
GENERAL NOTE:
REFER TO DEMOLITION LEVEL 7 FLOOR PLAN
FOR EXTENT OF AREA OF DEMOLITION AND
FURTHER INFORMATION.
NTS
DEMOLITION LEGEND
Drawing Issue Date
Core and Shell Addendum #1 05-27-16
| Sheets |
| MD103 - DEMOLITION LEVEL 2 HVAC FLOOR PLAN - WEST |
| MD104 - DEMOLITION LEVEL 2 HVAC FLOOR PLAN - EAST |
| MH103 - LEVEL 2 - HVAC FLOOR PLAN - WEST |
| MH104 - LEVEL 2 - HVAC FLOOR PLAN - EAST |
File details come from the government source that posted it. Updated .