MH104.pdf
PDF 296 KB Posted
- Attached to
- Restack of the William J. Green Federal Building
- Solicitation number
- GS-03-P-16-AZ-C-7004
About this file
Drawing MH104
View the file
Other files
Show 40 more
Latest 50 of 68 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FC
VAV
VAV
12"ø
R-1
0 CFM
VAV
6"ø VAV
NOT IN CONTRACT, UNLESS OTHERWISE NOTED
TENANT IMPROVEMENT - REFER TO LEVEL 7
AS TYPICAL, UNLESS OTHERWISE NOTED
CORE AND SHELL - REFER TO LEVEL 7 AS
TYPICAL, UNLESS OTHERWISE NOTED
N
PROPERTY OF THE UNITED
STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice.
Properly destroy or return documents when no longer needed.
(SBU)
SENSITIVE BUT UNCLASSIFIED
EAST
© 2015 Erdy McHenry Architecture, LLC
DRAWN BY:
Erdy McHenry Architecture, LLC 915 North Orianna Street Philadelphia, Pennsylvania 19123 ph: 215.925.7000 fax: 215.925.1990 web: http://www.em-arc.com
Architect: SCOTT A. ERDY, AIA
DAVID S. MCHENRY, AIA
emArchitecture
SCALE:
PROJECT NO:
DATE:
SHEET NUMBER:
P lo tte d:
KEY PLAN
As indicated
MH104
LEVEL 2 - HVAC
FLOOR PLAN - EAST
1158.00/SCR-2015216.00DLA
05-06-16
600 Arch Street
Philadelphia, PA 19107
GREEN FEDERAL BUILDING
CONSOLIDATION
Program + Strategy Consultant Studio Hillier 190 Witherspoon Street Princeton, NJ 08542
Greenman - Pedersen, Inc. (GPI) 50 Glenmaura National Blvd.
Suite 102 Scranton, PA 18505
Cerami & Associates 404 Fifth Avenue New York, NY 10018
TCT Cost Consultants, LLC 1090 Vermont Avenue NW Suite 230 Washington, DC 20005
Weidlinger Associates, INC 1825 K Street Avenue NW Suite 350 Washington, DC 20006
Antis Veterans Engineering adn Technical Services 2074 Cobblestone Lane Suite 850 Reston, VA 20191
Structural Engineer
MEP Engineer
Acoustical Consultant
Cost Specialist
Security + Blast
Praxis Building Solutions, LLC 2401 Walnut Street Suite 102 Philadelphia, PA 19103
Green Building Consultant
Beam, Ltd 428 West Waverly Road Glenside, PA 19038
Lighting Consultant
GSA Project Data William J. Green Federal Building GSA Project #: VPA00027 GSA Building #: PA0277 GSA Contract #: GS-03P-14-AZ-C-0020 GSA Solicitation #: GS-03P-15-AZ-C-1020
Core & Shell Package 05-06-16
Scale: 1/8" = 1'-0"1 LEVEL 2 - HVAC DUCTWORK - EAST
GENERAL NOTE:
REFER TO LEVEL 7 FLOOR PLAN FOR
EXTENT OF AREA OF NEW WORK AND
FURTHER INFORMATION.
NTS
NEW CONSTRUCTION LEGEND
Revision Number Drawing Issue Date
1 Core & Shell Addendum #1 06-03-16
| Sheets |
| MD103 - DEMOLITION LEVEL 2 HVAC FLOOR PLAN - WEST |
| MD104 - DEMOLITION LEVEL 2 HVAC FLOOR PLAN - EAST |
| MD501 - SCHEMATICS AND INSTALL PATH |
| MH103 - LEVEL 2 - HVAC FLOOR PLAN - WEST |
| MH104 - LEVEL 2 - HVAC FLOOR PLAN - EAST |