Fort Bliss Gravesite Expansion BD Part 8.pdf
PDF 14 MB Posted
- Solicitation number
- 36C78626B0028
About this file
This document comprises architectural bid documents for renovation and repair work at Fort Bliss National Cemetery in El Paso, Texas, specifically addressing three structures: the Honor Guard Shelter (Building 3302), Irrigation Pump House (Building 3W01), and Rostrum (Building 4101).
Honor Guard Shelter (Building 3302): The contract requires demolition of existing reinforced concrete slab (approximately 13 feet by 13 feet), removal and salvage of three metal benches with fastening hardware, and construction of a new reinforced concrete slab with color admixture matching adjacent existing concrete sidewalk. Work includes protection of four existing stone-veneered columns, installation of continuous control joints, and reinstatement of salvaged benches with refastened hardware. Materials specified include concrete with liquid densifier/sealer (Sika Sikafloor-959 SC). The structure includes existing Honor Guard and Committal Shelters with roof overhang approximately 10 feet above the slab.
Irrigation Pump House (Building 3W01) and Rostrum (Building 4101): The pump house scope involves floor and roof plan work with exterior elevations, including removal and replacement of damaged clay roof tiles (up to 10 tiles total), realignment of misaligned tiles at roof edges, and eave closure repairs. The Rostrum project encompasses demolition of a 270-square-foot reinforced concrete floor slab, removal and salvage of existing military seals and posts, reinstallation of refurbished bronze seals with new steel posts embedded in reinforced concrete footings, paint removal and refinishing of wrought iron stair railings and guardrails using chemical methods with epoxy primers and topcoats (Sherwin Williams Pro Industrial and Latitude products), repointing of mortar joints, and turf area repairs. All work requires coordination with the owner, preservation of adjacent structures and vegetation, and patching of disturbed areas to match existing conditions. The documents note the project is not sprinklered and include consultant contacts for irrigation, geotechnical, cost estimating, and fire/security disciplines.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
13'-0"
'-0
FL2
FL3
FL1
FL5
FL6
EXISTING
HONOR
GUARD
SHELTER
(NIC)
EXISTING
COMMITTAL
SHELTER
3 TYP
FL4
TURF
AREA
TURF
AREA
4 TYP
FL4
CONTROL JOINT,
TYP - SEE
STRUCTURAL
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING OTHER SYSTEMS. THIS INCIDENTAL WORK
MUST BE PART OF THIS CONTRACT. INSPECT THESE AREAS TO ASCERTAIN WORK
REQUIRED AND PERFORM THE WORK IN ACCORDANCE OF CONTRACT
REQUIREMENTS.
2. PROVIDE FIREPROOFING TO THE RATING REQUIRED AS INDICATED IN THE LIFE
SAFETY PLAN, CODE SUMMARY AND PER NFPA ON STRUCTURAL STEEL ELEMENTS.
3. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
4. PATCH AREAS DISTURBED OR MODIFIED BY THIS WORK WITH MATERIALS TO MATCH
EXISTING ADJACENT SURFACES OR SCHEDULED FINISHES AND TO A LIKE NEW
CONDITION.
5. ABBREVIATIONS AND SYMBOLS OF ARCHITECTURAL, STRUCTURAL, MECHANICAL,
AND ELECTRICAL MAY VARY BY DISCIPLINE. SEE RESPECTIVE DISCIPLINE SECTIONS
AND/OR DRAWINGS FOR DEFINITIONS.
6. DEFINITIONS OF COMMON TERMS.
• FURNISH: TO SUPPLY AND DELIVER TO THE SITE, READY FOR INSTALLATION
• INSTALL: TO PLACE INTO POSITION SERVICE OR USE
• PROVIDE: TO FURNISH AND INSTALL
7. SEE PHOTO DETAIL 5 THIS SHEET FOR EXISTING STRUCTURE CONDITION.
8. REFER TO STRUCTURAL FOR REQUIRED CONCRETE JOINTING TYPES, LOCATIONS
AND DETAILS.
9. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL STRUCTURES, EQUIPMENT,
AND VEGETATION (SUCH AS TREES, SHRUBS, AND GRASS) ON OR ADJACENT TO THE
WORK SITE, WHICH ARE NOT TO BE REMOVED AND WHICH DO NOT UNREASONABLY
INTERFERE WITH THE WORK REQUIRED UNDER THIS CONTRACT. REFER TO
GENERAL REQUIREMENTS SPECIFICATION SECTION 010002.
10. REFER TO PROJECT MATERIAL SCHEDULE ON THIS SHEET AND PROJECT
SPECIFICATIONS FOR SPECIFIC PRODUCT SELECTION REQUIREMENTS
11. MANUFACTURER'S TRADE NAMES AND NUMBERS USED IN MATERIAL SCHEDULES
ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES AND PATTERNS. PRODUCTS
OF OTHER MANUFACTURERS CONSISTENT WITH THE COLORS, FINISHES, TEXTURES,
PATTERNS AND, AT MINIMUM, MEETS THE TECHNICAL SPECIFICATIONS WILL BE
REVIEWED IN ACCORDANCE WITH SPECIFICATION SECTION 01 33 23 SHOP
DRAWINGS, PRODUCT DATA, AND SAMPLES
DEMOLITION PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
DEMOLISH EXISTING REINFORCED CONCRETE SLAB AND ANY ASSOCIATED
EXPANSION JOINT MATERIAL BETWEEN REMOVED SLAB AND ADJACENT
PAVEMENT OR STRUCTURE
DE2
REMOVE AND SALVAGE EXISTING METAL BENCHES AND FASTENING
HARDWARE
DE3 EXISTING CONCRETE SIDEWALK NOT IN CONTRACT
13'-0" (DEMO SLAB)
'-0
D E
M O
S
LA
B
DE1
DE2
3 TYP
EXISTING
HONOR
GUARD
SHELTER
DE3
(NIC)
EXISTING
COMMITTAL
SHELTER
TURF
AREA
TURF
AREA
DEMOLITION GENERAL NOTES
1. CONTRACTOR MUST COORDINATE ALL DEMOLITION WORK, PHASING AND
SEQUENCING WITH THE OWNER. ANY INFORMATION REGARDING SEQUENCING
PROVIDED IN THESE DOCUMENTS IS FOR ARCHITECT - OWNER PLANNING
PURPOSES ONLY, UNLESS NOTED OTHERWISE.
2. CONTRACTOR MUST BE RESPONSIBLE FOR COORDINATING WITH ALL TRADES FOR
THE DEMOLITION WORK REQUIRED FOR THIS PROJECT..
3. ALL DISTURBED AREAS, TURF, WALKWAYS, COLUMN FINISHES, ETC, DAMAGED BY
DEMOLITION WORK MUST BE PATCHED TO MATCH ADJACENT AREA.
4. OWNER RESERVES THE RIGHT OF FIRST REFUSAL OF ALL SALVAGED ITEMS SUCH
AS: DOORS, LIGHT FIXTURES, PLUMBING FIXTURES ETC.
5. SALVAGED ITEMS NOTED FOR REUSE MUST BE CLEANED, RESTORED AND/OR
REFINISHED TO LIKE NEW CONDITION, UNLESS NOTED OTHERWISE.
6. DO NOT REMOVE ANY EXISTING STRUCTURAL SUPPORT MEMBERS SUCH AS
COLUMNS, BEAMS, JOISTS, LOAD-BEARING PARTITIONS ETC, UNTIL ADEQUATE
PERMANENT OR TEMPORARY SUPPORT IS IN PLACE. ALL EXISTING STRUCTURAL
MEMBERS MUST BE ADEQUATELY PROTECTED, COORDINATE WITH STRUCTURAL
ENGINEER.
7. SEE STRUCTURAL, CIVIL AND LANDSCAPE ARCHITECTURE DRAWINGS FOR
RELATED DEMOLITION AND PREP WORK.
8. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL STRUCTURES,
EQUIPMENT, AND VEGETATION (SUCH AS TREES, SHRUBS, AND GRASS) ON OR
ADJACENT TO THE WORK SITE, WHICH ARE NOT TO BE REMOVED AND WHICH DO
NOT UNREASONABLY INTERFERE WITH THE WORK REQUIRED UNDER THIS
CONTRACT. REFER TO GENERAL REQUIREMENTS SPECIFICATION SECTION 010002.
FLOOR PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FL1
REINFORCED CONCRETE SLAB W/ COLOR ADMIXTURE TO MATCH
ADJACENT EXISTING CONCRETE SIDEWALK - SEE STRUCTURAL AND
DIVISION 3 SPECIFICATIONS
FL2
PROTECT (4) EXISTING STONE VENEERED COLUMNS. COLUMN BASE IS
UNEVEN, NOT A STRAIGHT LINE AS GRAPHICALLY SHOWN. SEE PHOTO
DETAIL 4 THIS SHEET
FL3
REINSTALL (3) BENCHES SALVAGED DURING DEMOLITION AND REFASTEN
TO CONCRETE SLAB. REPLACE OR ADD ANY MISSING OR BROKEN
FASTENING HARDWARE IN KIND WITH EXISTING AT NO ADDITIONAL
CHARGE, PAINT ALL BENCH FASTENERS COLOR TO MATCH BENCHES,
TYPICAL FASTENING SHOWN IN PHOTO DETAIL 3 THIS SHEET
FL4
CONTINUOUS CONTROL JOINT AT BOUNDARY BETWEEN EXISTING AND
NEW CONC SLAB AND AT ALL (4) COLUMN BASES- SEE STRUCTURAL
FL5
LINE OF ROOF OVERHANG ABOVE. LOW POINT OF ROOF STRUCTURE
APPROXIMATELY 10'-0" ABOVE SLAB
FL6 EXISTING ADJACENT CONC SIDEWALK NOT IN CONTRACT
DEMOLITION PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL OR
PARTITION TO BE
REMOVED
KEY NOTE
A
GRIDLINE
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
DE10
DASHED LINE
INDICATES ITEM TO
BE REMOVED (UNO)
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
8'-0"
DIMENSION LINE,
NOMINAL
8'-0" EXTENDED
DIMENSION LINE,
NOMINAL
XXXX-
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR SPOT
ELEVATION
WALL TAG
OFFICE
ROOM NAME AND
NUMBER DETAIL REFERENCE
TAG
EXTERIOR SECTION
REFERENCE TAG
KEY NOTE
A GRIDLINE
REVISION TAG
PR01 REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
B3
XXXX-
AE2O1
1A
XXXX-
AE2O1
1A
MATERIAL LEGEND
EXISTING
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
BRICK
BRICK
CONCRETE
GYPSUM BOARD
GRAVEL / FILL
PLYWOOD
EARTH
PLAN & SECTION SECTION
ELEVATION
NEW CONSTRUCTION
CMU
RIGID INSULATION
SPRAY FOAM
STONE
WOOD - HORIZONTAL
WOOD - VERTICAL
FIRE PROOFING
CMU
CONCRETE
METAL
MORTAR NET
SOLID SURFACE
STONE
BATT INSULATION
STUCCO
SITE KEY MAP NTS
HONOR
GUARD
SHELTER -
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
COST ESTIMATING:
OCMI
2100 NORTH GREENVILLE AVENUE
SUITE 1150
RICHARDSON, TX 75082
469.431.0571
RAYMOND BODO
FIRE / L0W VOLTAGE / SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER / PETE MCGHEE
CHRISTINA MCDANIEL
06/15/2026
52909
C U s e rs
\j tu c h te n h a g e n \D o c u m e n ts
\1
-H
G -A
-2 jt u c h te n h a g e n a e
-m n .c o m
.r v t
/1
/2
:0
:1
A
M
3302-AE111
HONOR GUARD SHELTER - DEMO PLAN AND
FLOOR PLAN
FT BLISS NATIONAL CEMETERY
EXPANSION
5200 FRED WILSON AVE, EL PASO,TX
886CM3026
JUNE 15, 2026 CM RG
18528
0 4' 8'2'1/4" = 1'-0"
FLOOR PLAN
1/4" = 1'-0"
DEMO FLOOR PLAN
0 4' 8'2'
NOT TO SCALE3
PHOTO DETAIL - BENCH FASTENING
NOT TO SCALE4
PHOTO DETAIL - COLUMN BASE
NOT TO SCALE5
PHOTO DETAIL - EXISTING STRUCTURE
03 30 53
CONC SLNT LIQUID DENSIFIER/SEALER SIKA USA SIKAFLOOR-959 SC CLEAR N/A
SPEC NO. CODE MATERIAL MANUFACTURER STYLE COLOR SIZE REMARKS
BLDG 3302 - MATERIAL SCHEDULE
Revisions: Date: 101 of 155
BASE BID
PUMP
ROOM
3W01-
AE111
3W01-
AE111
3W01-
AE111
2' -0
'-8
2' -0
2'-0" 22'-8" 2'-0"
ROOF OVERHANG ABOVE
3W01-
AE111
4SIM
+/- 26'-8"
6'
-8
RO1
RO2
RO3
RO4
FIRST LEVEL
100'-0"
E X
IS
T
IN
G
T O
P O
F E
A V
E H
E
IG
H T
'-5
E X
IS
T
IN
G
S
LO
P E
D R
O O
F H
E
IG
H T
1'
-4
RO2
TOP OF GRADE
FIRST LEVEL
100'-0"
E X
IS
T
IN
G
S
LO
P E
D R
O O
F H
E
IG
H T
1'
-4
E X
IS
T
IN
G
T O
P O
F E
A V
E H
E
IG
H T
'-5
RO1
TOP OF GRADE
RO4
EAST
ELEVATION
ONLY
RO3
EAST
ELEVATION
ONLY
WEST
ELEVATION
ONLY
FIRST LEVEL
100'-0"
E X
IS
T
IN
G
S
LO
P E
D R
O O
F H
E
IG
H T
1'
-4
E X
IS
T
IN
G
T O
P O
F E
A V
E H
E
IG
H T
'-5
RO3
RO1
TOP OF GRADE
ROOF PLAN AND ELEVATION KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
RO1
REMOVE REMNANTS OF FAILED EAVE CLOSURE AND ASSOCIATED CLAY
TILE IF DAMAGED OR MISALIGNED.PROVIDE EAVE CLOSURE AND REALIGN,
REFASTEN, OR INSTALL NEW CLAY TILE AS NEC TO PROVIDE ALIGNED,
SECURED, UNDAMAGED TILES IN THIS AREA (5 SF MAX AREA). SEE PHOTO
DETAIL 6 THIS SHEET.
RO2
REMOVE AND REPLACE CRACKED AND/OR CHIPPED CLAY TILES IN THIS
AREA. ADDITIONALLY, REMOVE UP TO A TOTAL OF 10 CLAY ROOF TILES,
INCLUDING THE ONES IN THIS HATCHED AREA, FOR THE ENTIRE ROOF FOR
ANY OTHER OBSERVED CRACKED OR CHIPPED CLAY ROOF TILES, AS
IDENTIFIED BY THE VA COR DURING CONSTRUCTION. SEE PHOTO DETAIL 7
THIS SHEET.
RO3
REALIGN AND RE-SECURE MISSALIGNED TILE AT ROOF EDGE. REPLACE
TILE IF NECESSARY. MODIFY ADJACENT TILES AS NECESSARY TO ENSURE
PROPER ALIGNMENT AT ROOF EDGE. SEE PHOTO DETAIL 8 THIS SHEET.
RO4
REMOVE AND REPLACE CRACKED AND/OR CHIPPED CLAY TILES IN THIS
AREA. REALIGN AND RESECURE MISSALIGNED TILES AT ROOF EDGE (5 SF
MAX AREA). SEE PHOTO DETAIL 9 THIS SHEET.
DEMOLITION GENERAL NOTES
1. CONTRACTOR MUST COORDINATE ALL DEMOLITION WORK, PHASING AND
SEQUENCING WITH THE OWNER. ANY INFORMATION REGARDING SEQUENCING
PROVIDED IN THESE DOCUMENTS IS FOR ARCHITECT - OWNER PLANNING
PURPOSES ONLY, UNLESS NOTED OTHERWISE.
2. CONTRACTOR MUST BE RESPONSIBLE FOR COORDINATING WITH ALL TRADES FOR
THE DEMOLITION WORK REQUIRED FOR THIS PROJECT.
3. ALL DISTURBED AREAS DAMAGED BY DEMOLITION WORK MUST BE PATCHED TO
MATCH ADJACENT AREA.
4. OWNER RESERVES THE RIGHT OF FIRST REFUSAL OF ALL SALVAGED ITEMS.
5. DO NOT REMOVE ANY EXISTING STRUCTURAL SUPPORT MEMBERS SUCH AS
COLUMNS, BEAMS, JOISTS, LOAD-BEARING PARTITIONS ETC, UNTIL ADEQUATE
PERMANENT OR TEMPORARY SUPPORT IS IN PLACE. ALL EXISTING STRUCTURAL
MEMBERS MUST BE ADEQUATELY PROTECTED, COORDINATE WITH STRUCTURAL
ENGINEER.
6. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL STRUCTURES,
EQUIPMENT, AND VEGETATION (SUCH AS TREES, SHRUBS, AND GRASS) ON OR
ADJACENT TO THE WORK SITE, WHICH ARE NOT TO BE REMOVED AND WHICH DO
NOT UNREASONABLY INTERFERE WITH THE WORK REQUIRED UNDER THIS
CONTRACT. REFER TO GENERAL REQUIREMENTS SPECIFICATION SECTION 010002.
SYMBOL LEGEND
EXISTING WALL TO
REMAIN
WALL OR
PARTITION TO BE
REMOVED
EXISTING DOOR
AND FRAME TO
REMAIN
KEY NOTE
A
GRIDLINE
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
EXISTING DOOR
AND FRAME TO BE
DEMOLISHED
DASHED LINE
INDICATES ITEM TO
BE REMOVED (UNO)
DE10
AREA OF DEMO /
PATCHWORK
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING ELECTRICAL, MECHANICAL, PLUMBING AND
OTHER SYSTEMS. THIS INCIDENTAL WORK MUST BE PART OF THIS CONTRACT.
INSPECT THESE AREAS TO ASCERTAIN WORK REQUIRED AND PERFORM THE WORK
IN ACCORDANCE OF CONTRACT REQUIREMENTS.
2. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
3. ABBREVIATIONS AND SYMBOLS OF ARCHITECTURAL, STRUCTURAL, MECHANICAL,
AND ELECTRICAL MAY VARY BY DISCIPLINE. SEE RESPECTIVE DISCIPLINE SECTIONS
AND/OR DRAWINGS FOR DEFINITIONS.
4. DEFINITIONS OF COMMON TERMS.
• FURNISH: TO SUPPLY AND DELIVER TO THE SITE, READY FOR INSTALLATION
• INSTALL: TO PLACE INTO POSITION SERVICE OR USE
• PROVIDE: TO FURNISH AND INSTALL
5. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL STRUCTURES, EQUIPMENT,
AND VEGETATION (SUCH AS TREES, SHRUBS, AND GRASS) ON OR ADJACENT TO THE
WORK SITE, WHICH ARE NOT TO BE REMOVED AND WHICH DO NOT UNREASONABLY
INTERFERE WITH THE WORK REQUIRED UNDER THIS CONTRACT. REFER TO
GENERAL REQUIREMENTS SPECIFICATION SECTION 010002.
SITE KEY MAP NTS
IRRIGATION
PUMP HOUSE-
3W01
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
COST ESTIMATING:
OCMI
2100 NORTH GREENVILLE AVENUE
SUITE 1150
RICHARDSON, TX 75082
469.431.0571
RAYMOND BODO
FIRE / L0W VOLTAGE / SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER / PETE MCGHEE
CHRISTINA MCDANIEL
06/15/2026
52909
C U s e rs \j tu c h te n h a g e n \D o c u m e n ts
\1
-I R
R P
U M
P E
N C
L -A
-R jt u c h te n h a g e n a e
-m n
.c o m .r v t
/1
/2
:1
:3
A
M
3W01- AE111
IRRIGATION PUMP HOUSE - FLOOR & ROOF
PLANS AND EXTERIOR ELEVATIONS
FT BLISS NATIONAL CEMETERY
EXPANSION
5200 FRED WILSON AVE, EL PASO,TX
886CM3026
3W01
JUNE 15, 2026 CM RG
18528
0 4' 8'2' 1/4" = 1'-0"
FLOOR PLAN
1/4" = 1'-0"
ROOF PLAN
0 4' 8'2'
1/4" = 1'-0"
EXTERIOR ELEVATION - NORTH
1/4" = 1'-0"
EXTERIOR ELEVATION - EAST ( WEST SIMILAR)
1/4" = 1'-0"
EXTERIOR ELEVATION - SOUTH
0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
NOT TO SCALE7
PHOTO DETAIL - ROOF DAMAGE AREA KEYNOTE RO2
NOT TO SCALE6
PHOTO DETAIL - ROOF DAMAGE AREA KEYNOTE RO1
NOT TO SCALE8
PHOTO DETAIL - ROOF DAMAGE AREA KEYNOTE RO3
NOT TO SCALE9
PHOTO DETAIL - ROOF DAMAGE AREA KEYNOTE RO4
Revisions: Date: 102 of 155
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING OTHER DISCIPLINES AND OTHER SYSTEMS.
THIS INCIDENTAL WORK MUST BE PART OF THIS CONTRACT. INSPECT THESE AREAS
TO ASCERTAIN WORK REQUIRED AND PERFORM THE WORK IN ACCORDANCE OF
CONTRACT REQUIREMENTS.
2. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
3. DIMENSIONS OF EQUIPMENT ARE THOSE OF THE BASIS-OF-DESIGN EQUIPMENT.
VERIFY DIMENSIONS OF ACTUAL EQUIPMENT BEING PROVIDED TO COORDINATE
SPACE REQUIREMENTS.
4. PATCH AREAS DISTURBED OR MODIFIED BY THIS WORK WITH MATERIALS TO MATCH
EXISTING ADJACENT SURFACES OR AND TO A LIKE NEW CONDITION.
5. ABBREVIATIONS AND SYMBOLS OF ARCHITECTURAL, STRUCTURAL, MECHANICAL,
AND ELECTRICAL MAY VARY BY DISCIPLINE. SEE RESPECTIVE DISCIPLINE SECTIONS
AND/OR DRAWINGS FOR DEFINITIONS.
6. DEFINITIONS OF COMMON TERMS.
• FURNISH: TO SUPPLY AND DELIVER TO THE SITE, READY FOR INSTALLATION
• INSTALL: TO PLACE INTO POSITION SERVICE OR USE
• PROVIDE: TO FURNISH AND INSTALL
7. ALL REFURBISHMENT ACTIVITIES TO REMAIN ONSITE, UNLESS OTHERWISE
APPROVED BY THE VA COR.
8. SEE PHOTOS 1 AND 2 ON SHEET 4101-AE501 FOR EXISTING MILITARY SEALS
FASTENING CONDITIONS TO MATCH.
9. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL STRUCTURES, EQUIPMENT,
AND VEGETATION (SUCH AS TREES, SHRUBS, AND GRASS) ON OR ADJACENT TO THE
WORK SITE, WHICH ARE NOT TO BE REMOVED AND WHICH DO NOT UNREASONABLY
INTERFERE WITH THE WORK REQUIRED UNDER THIS CONTRACT. REFER TO
GENERAL REQUIREMENTS SPECIFICATION SECTION 010002.
10. REFER TO PROJECT MATERIAL SCHEDULE ON THIS SHEET AND PROJECT
SPECIFICATIONS FOR SPECIFIC PRODUCT SELECTION REQUIREMENTS
11. MANUFACTURER'S TRADE NAMES AND NUMBERS USED IN MATERIAL SCHEDULES
ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES AND PATTERNS. PRODUCTS
OF OTHER MANUFACTURERS CONSISTENT WITH THE COLORS, FINISHES, TEXTURES,
PATTERNS AND, AT MINIMUM, MEETS THE TECHNICAL SPECIFICATIONS WILL BE
REVIEWED IN ACCORDANCE WITH SPECIFICATION SECTION 01 33 23 SHOP
DRAWINGS, PRODUCT DATA, AND SAMPLES
4101-
AE201
DE1
DE2 DE2
DE2
DE2 DE2
DE3
4101-
AE201
4101-
AE201
4101-
AE201
LECTERN
DE3
DE3
DE3DE3DE3DE3
DE3
DE3
4101-
AE201
FL6
4101-
AE201
4101-
AE201
4101-
AE201
FL1 FL1 FL1 FL1
FL5
FL5
FL7
FL2
FL8.2
FL8.1
FL9
FL1 FL3
4101-
AE201
4'-6" 4'-6"4'-6" 4'-6"
FL10
LECTERN
D O
W N
MATCH EXISTING
MATCH EXISTING
MATCH EXISTING
MATCH EXISTING
HIGH POINT
E Q
E Q
E Q
E Q
EQ EQ
TYP
FL8.2
FL8.2
FL8.2
FL8.2 FL8.2FL8.2 FL8.2
FL11
1' -3
FL4
DEMOLITION GENERAL NOTES
1. CONTRACTOR MUST COORDINATE ALL DEMOLITION WORK, PHASING AND
SEQUENCING WITH THE OWNER. ANY INFORMATION REGARDING SEQUENCING
PROVIDED IN THESE DOCUMENTS IS FOR ARCHITECT - OWNER PLANNING
PURPOSES ONLY, UNLESS NOTED OTHERWISE.
2. CONTRACTOR MUST BE RESPONSIBLE FOR COORDINATING WITH ALL TRADES FOR
THE DEMOLITION WORK REQUIRED FOR THIS PROJECT.
3. WHERE PARTITIONS ARE INDICATED TO BE REMOVED, REMOVE PARTITION ALONG
WITH ALL ITEMS CONTAINED WITHIN, INCLUDING DOORS, FRAMES, HARDWARE,
SIDELIGHTS, WINDOWS, MECHANICAL AND ELECTRICAL EQUIPMENT, ETC. TO
STRUCTURE ABOVE, UNLESS NOTED OTHERWISE.
4. WHERE FLOOR FINISH IS INDICATED TO BE DEMOLISHED, REMOVE FINISH TO
FLOOR SLAB AS REQUIRED AND PREPARE SLAB SURFACE FOR SCHEDULED
FINISHES WITHIN AREA TO BE REMODELED, UNLESS NOTED OTHERWISE. SEE
FINISH SCHEDULE FOR EXISTING FLOOR FINISHES TO REMAIN UNDISTURBED.
5. WHERE CEILING IS INDICATED TO BE DEMOLISHED, REMOVE CEILING SUSPENSION
SYSTEM ALONG WITH ALL ASSOCIATED MECHANICAL AND ELECTRICAL ITEMS,
UNLESS NOTED OTHERWISE. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
EXTENT OF CONDUIT, PIPING AND DUCTWORK DEMOLITION WITHIN AREA TO BE
REMODELED.
6. WHERE INDICATED, REMOVE ALL WALL/PARTITION EXISTING FINISHES AND
PREPARE THE SURFACES FOR SCHEDULED FINISHES, SEE FINISH SCHEDULE FOR
FINISHES.
7. ALL DISTURBED AREAS, WALLS, PARTITIONS, FLOORS, ETC, DAMAGED BY
DEMOLITION WORK MUST BE PATCHED TO MATCH ADJACENT AREA.
8. OWNER RESERVES THE RIGHT OF FIRST REFUSAL OF ALL SALVAGED ITEMS SUCH
AS: DOORS, LIGHT FIXTURES, PLUMBING FIXTURES ETC.
9. SALVAGED ITEMS SCHEDULED FOR REUSE MUST BE CLEANED, RESTORED AND/OR
REFINISHED TO LIKE NEW CONDITION, UNLESS NOTED OTHERWISE.
10. DO NOT REMOVE ANY EXISTING STRUCTURAL SUPPORT MEMBERS SUCH AS
COLUMNS, BEAMS, JOISTS, LOAD-BEARING PARTITIONS ETC, UNTIL ADEQUATE
PERMANENT OR TEMPORARY SUPPORT IS IN PLACE. ALL EXISTING STRUCTURAL
MEMBERS MUST BE ADEQUATELY PROTECTED, COORDINATE WITH STRUCTURAL
ENGINEER.
11. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR RELATED
DEMOLITION AND PREP WORK.
12. WALL AND CEILING MOUNTED ITEMS SHOWN DASHED, SUCH AS WALL CABINETS,
SHELVING, CUBICLE CURTAIN TRACKS, PROJECTION SCREENS ETC, MUST BE
REMOVED, UNLESS NOTED OTHERWISE.
13. WITHIN ALL EXISTING ROOMS/SPACES RECEIVING SCHEDULED FLOOR, OR WALL,
OR CEILING FINISHES, REMOVE ALL EXISTING FLOOR, OR WALL, OR CEILING
FINISHES DOWN TO THE SUBSTRATE. INCLUDE THE REMOVAL OF ALL ITEMS
LOCATED WITHIN THE EXISTING FINISH REMOVALS UNO PATCH AND PREP ALL
SUBSTRATES TO RECEIVE SCHEDULED FINISHES. FOR ADDITIONAL INFORMATION,
SEE KEYNOTED ITEMS, FINISH PLANS AND/OR SCHEDULES, STRUCTURAL,
MECHANICAL AND ELECTRICAL.
14. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL STRUCTURES,
EQUIPMENT, AND VEGETATION (SUCH AS TREES, SHRUBS, AND GRASS) ON OR
ADJACENT TO THE WORK SITE, WHICH ARE NOT TO BE REMOVED AND WHICH DO
NOT UNREASONABLY INTERFERE WITH THE WORK REQUIRED UNDER THIS
CONTRACT. REFER TO GENERAL REQUIREMENTS SPECIFICATION SECTION 010002.
DEMOLITION PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL OR
PARTITION TO BE
REMOVED
KEY NOTE
A
GRIDLINE
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
DASHED LINE
INDICATES ITEM TO
BE REMOVED (UNO)
DE10
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
8'-0"
DIMENSION LINE,
ACTUAL
8'-0" EXTENDED
DIMENSION LINE,
ACTUAL
AE2111A
INTERIOR
ELEVATION
INDICATOR TAG
2B
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR SPOT
ELEVATION
AE501
1A
DETAIL REFERENCE
TAG
AE2O1
EXTERIOR SECTION
REFERENCE TAG
1A
AE2O1
INTERIOR SECTION
REFERENCE TAG
1A
KEY NOTE
A
GRIDLINE
REVISION TAG
PR01
REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
FLOOR PLAN KEY NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FL1
REINSTALL 24" DIA MILITARY SEALS FASTENED TO NEW 1 3/4" DIA PAINTED
STEEL POST WITH NEW FASTENERS IN-KIND WITH EXISTING. POST HEIGHT
TO MATCH EXISTING. EMBED STEEL POST IN REINF CONC FOOTING PER
DETAIL 4/4001-S-101. REFURBISH EXISTING BRONZE SEALS BY STRIPPING
EXISTING LACQUER USING CHEMICAL METHODS. APPLY NEW COAT OF
LACQUER.
FL2 EXISTING GRANITE BORDER ALONG ENTIRE STRUCTURE PERIMETER
FL3
INSTALL 24" DIA BRONZE MILITARY SEAL FASTENED TO 1 3/4" DIA PAINTED
STEEL POST. POST HEIGHT SHALL MATCH EXISTING. EMBED STEEL POST
IN REINF CONC FOOTING PER DETAIL 4/4001-S-101.
FL4
PROVIDE NEW 270 SF REINF INTEGRALLY COLORED CONC SLAB W/
CENTRAL HIGHPOINT AND CONSISTENT SLOPE DOWNWARD TO PERIMETER
EDGES TO FACILITATE EVEN DRAINING. PROVIDE LIQUID DENSIFIER
SURFACE TREATMENT FOR ENTIRETY OF EXPOSED SLAB - SEE
STRUCTURAL
FL5 EXISTING GUTTER CUT IN GRANITE COPING
FL6
PROVIDE 3/8" WIDE BOND BREAK BETWEEN CONCRETE AND NATURAL
STONE WITH CONTINUOUS EXPANSION JOINT FILLER AND JOINT SEALANT,
COLOR TO MATCH NEW FINISHED SLAB.
FL7 CONCRETE CONTROL JOINT SEE STRUCTURAL
FL8.1
REMOVE PAINT FROM (2) WROUGHT IRON STAIR RAILINGS AND
ASSOCIATED POSTS AND BALUSTERS USING CHEMICAL METHODS. HEAT
WELD DISCONNECTED SEGMENTS OF WROUGHT IRON STAIR RAILING BACK
TOGETHER, MAX 8 LF WELDING PER RAILING, REMOVE RUST WITH A RUST
NEUTRALIZER BEFORE PRIMING. APPLY PRIMER, INTERMEDIATE AND TOP
PAINT COATS TO BOTH WROUGHT IRON RAILINGS, POSTS AND BALUSTERS
(P-10). SEE MATERIAL SCHEDULE ON THIS SHEET AND SPECIFICATIONS
FOR MORE INFORMATION
FL9 REPAIR TURF AREAS DAMAGED DURING CONSTRUCTION
FL10
REPOINT UP TO 4 LINEAL FEET OF MORTAR AT BASE OF COLUMN AND
WHERE INDICATED BY THE VA COR. COLOR TO MATCH ADJACENT EXISTING
MORTAR. SEE PHOTO, DETAIL 3/4101-AE501
FL11 EXISTING GRANITE STEPS TO REMAIN
FL8.2
REMOVE PAINT FROM (2) WROUGHT IRON GUARDRAILS AND ASSOCIATED
POSTS AND BALUSTERS USING CHEMICAL METHODS. REMOVE RUST WITH
A RUST NEUTRALIZER BEFORE PRIMING. APPLY PRIMER, INTERMEDIATE
AND TOP PAINT COATS TO GUARDRAILS, POSTS AND BALUSTERS (P-10).
SEE MATERIAL SCHEDULE ON THIS SHEET AND SPECIFICATIONS FOR
MORE INFORMATION
DEMOLITION KEY NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
CAREFULLY REMOVE REINFORCED CONC FLOOR SLAB IN IT'S ENTIRETY,
APPROX 270 SF, SO AS NOT TO DAMAGE EXISTING STRUCTURE, INCLUDING
BUT NOT LIMITED TO GRANITE PERIMETER WALL
DE2
REMOVE EXISTING MILITARY SEALS, POSTS, HARDWARE AND FOOTINGS.
SALVAGE SEALS FOR REINSTALLATION IN NEW LOCATION.
DE3
EXISTING STAIR RAIL AND ROSTRUM GUARDRAILS TO REMAIN IN PLACE;
SEE FLOOR PLAN FOR REFINISHING OF THESE ELEMENTS.
MATERIAL LEGEND
EXISTING
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
BRICK
CONCRETE
GYPSUM BOARD
GRAVEL / FILL
PLYWOOD
EARTH
PLAN & SECTION SECTION
NEW CONSTRUCTION
CMU
RIGID INSULATION
SPRAY FOAM
STONE
FIRE PROOFING
METAL
MORTAR NET
SOLID SURFACE
BATT INSULATION
SITE KEY MAP NTS
ROSTRUM
-4101
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
COST ESTIMATING:
OCMI
2100 NORTH GREENVILLE AVENUE
SUITE 1150
RICHARDSON, TX 75082
469.431.0571
RAYMOND BODO
FIRE / L0W VOLTAGE / SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER / PETE MCGHEE
CHRISTINA MCDANIEL
06/15/2026
52909
C U s e rs
\c z u p a n
\D o c u m e n ts \1
-R O
S T
R U
M -A
-R c z u p a n
J A
M E
X .r v t
/1
/2
:4
:5
P
M
4101- AE111
ROSTRUM - DEMOLITION AND FLOOR PLAN FT BLISS NATIONAL CEMETERY
EXPANSION
5200 FRED WILSON AVE, EL PASO,TX
886CM3026
JUNE 15, 2026 CM RG
18528
0 4' 8'2' 0 4' 8'2' 1/4" = 1'-0"
DEMOLITION PLAN
1/4" = 1'-0"
FLOOR PLAN
INTERMEDIATE AND TOPCOATS: LATITUDE EXTERIOR ACRYLIC - SATIN MATCH EXISTING N/A
P-11 PAINT SHERWIN WILLIAMS
PRIMER: EXTERIOR OIL-BASED WOOD PRIMER MATCH EXISTING N/A
INTERMEDIATE AND TOPCOATS: PRO INDUSTRIAL WATERBASED ALKYD URETHANE ENAMEL - GLOSS MATCH EXISTING N/A
09 91 00 P-10 PAINT SHERWIN WILLIAMS
PRIMER: PRO INDUSTRIAL KEM KROMIK UNIVERSAL METAL PRIMER MATCH EXISTING N/A
SPEC NO. CODE MATERIAL MANUFACTURER STYLE COLOR SIZE REMARKS
BLDG 4101 - MATERIAL SCHEDULE
Revisions: Date: 103 of 155
T.O FLOOR SLAB
100'-0"
EL2
EL5
EL9
4101-
AE201
EL10EL7EL7EL7EL9
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
C
IA
'-6
TOP OF GRADE
EL5 EL5
T.O FLOOR SLAB
100'-0"
'-6
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
DEL1
FASCIA BD REMOVAL
UP TO +/- 20' -0"
DEL5
DEL2
TOP OF GRADE
DEL5DEL5
T.O FLOOR SLAB
100'-0"
EL2
EL3
EL4
EL5
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
'-6
" EL9
TOP OF GRADE
EL1
T.O FLOOR SLAB
100'-0"
EL2
EL3
EL4
EL5
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
'-6
TOP OF GRADE
EL9
NOTES FOR EXTERIOR WOOD REPAIR WORK
1. PROVIDE WOOD FASCIA PAINT MOCK-UPS AS NECESSARY TO PRODUCE A PAINT TYPE,
GLOSS AND COLOR MATCH TO THE EXISTING PAINTED WOOD CORNICE WITH THE VA'S
APPROVAL.
2. REMOVE AND SALVAGE FOR REUSE EXISTING METAL ROOF TRIM PIECES TO ACCESS
EXISTING FASCIA BOARD FOR FASCIA BOARD REMOVAL, REPLACEMENT AND
REPAINTING AS NECESSARY.
3. REMOVE PAINT FROM ALL WOOD CORNICE COMPONENTS BY USING THE GENTLEST
METHOD POSSIBLE (HANDSCRAPING OR HANDSANDING) TO THE NEXT SOUND LAYER.
4. PREP NEW FASCIA WOOD FOR NEW EXTERIOR PAINT.
5. PRIME AND PROVIDE TOP FINISH COAT OF OPAQUE PAINT TO MATCH EXISTING.
6. REINSTALL/REATTACHED ROOF FLASHING PREVIOUSLY REMOVED TO ACCESS THE
FASCIA BOARD
7. OUTLOOKERS NOT DETAILED ON ELEVATIONS. SEE PHOTOS ON SHEET 4101-AE501
FOR TYPICAL 4" X 8" OUTLOOKERS SPACED AROUND ENTIRE STRUCTURE ROOFLINE
T.O FLOOR SLAB
100'-0"
'-6
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
EL1
EL5
EL4
4101-
AE201EL2
TOP OF GRADE
UP TO 20'-0" FASCIA REPLACEMENT
EL3
EL5
ELEVATION KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
EL1
REPLACE FASCIA BOARD IN-KIND WITH EXISTING, MATCH SIZE OF MEMBER
DEMOLISHED. SEE NOTES FOR EXTERIOR WOOD REPAIR WORK THIS
SHEET.
EL2
PREP ALL WOOD CORNICE AND OUTLOOKER SURFACES FOR NEW
EXTERIOR PAINT (P-11). PRIME AND PROVIDE TOP FINISH COAT OF
OPAQUE PAINT TO MATCH EXISTING. REINSTALL/ATTACH ALL ROOF
FLASHING PREVIOUSLY REMOVED TO ACCESS FASCIA BOARD
EL3
REMOVE PAINT FROM (2) WROUGHT IRON STAIR RAILINGS AND
ASSOCIATED POSTS AND BALLUSTERS USING CHEMICAL METHODS. HEAT
WELD DISCONNECTED SEGMENTS OF WROUGHT IRON RAILING BACK
TOGETHER, MAX 8 LF WELDING PER RAILING. APPLY EPOXY PRIMER,
INTERMEDIATE AND TOP COATS TO BOTH WROUGHT IRON STAIR RAILINGS,
POSTS AND BALUSTERS (P-10). SEE PHOTO DETAILS 5 AND 6 ON SHEET
4101/AE201 FOR OVERALL AND DETAILED EXISTING CONDITIONS OF STAIR
RAIL
EL4 EXISTING GRANITE STEPS TO REMAIN
EL5
REMOVE PAINT FROM WROUGHT IRON GUARDRAILS AND ASSOCIATED
POSTS AND BALLUSTERS USING CHEMICAL METHODS. APPLY EPOXY
PRIMER, INTERMEDIATE AND TOP COATS TO BOTH WROUGHT IRON STAIR
RAILINGS, POSTS AND BALUSTERS (P-10). SEE PHOTO DETAILS 4 THRU 6
ON SHEET 4101/AE201 EXISTING CONDITIONS OF GUARDRAIL.
EL6 NOT USED
EL7
REINSTALL MILITARY SEALS SALVAGED DURING DEMOLITION. FASTEN TO
METAL POST SET IN NEW REINFORCED CONCRETE FOOTING. SEE FLOOR
PLAN FOR MORE INFORMATION
EL8
PROVIDE NEW 270 SF REINFORCED CONC FLOOR W/ CENTRAL HIGHPOINT
AND CONSISTENT SLOPE DOWNWARD TO PERIMETER EDGES TO
FACILITATE EVEN DRAINING. EPOXY NEW REINFORCED SLAB INTO
EXISTING - SEE STRUCTURAL
EL9
REFURBISH EXISTING BRONZE MILITARY SEALS BY STRIPPING EXISTING
LACQUER. APPLY NEW COAT OF LACQUER. EXISTING POST AND FOOTING
TO REMAIN. REINSTALL SEALS IF REMOVED FOR REFURBISH WORK.
EL10
INSTALL MILITARY SEAL FASTENED TO METAL POST WHICH IS EMBEDDED
IN REINFORCED CONCRETE FOOTING. SEE FLOOR PLAN FOR MORE
INFORMATION
DEMOLITION ELEVATION KEY NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH ELEVATION
DEL1
REMOVE PAINT FROM WOOD CORNICE AND OUTLOOKERS AROUND ENTIRETY OF
STRUCTURE.
DEL2
REMOVE AND DISCARD UP TO 20 LF 2X4 FASCIA BOARD TO ALLOW COMPLETE
REMOVAL OF THE +/- 10 LF DAMAGED SEGMENT TO THE NEAREST BUTT JOINTS IN
THE FASCIA BOARD. SEE PHOTO DETAILS 4 AND 7 ON SHEET 4101/AE201
DEL3
REMOVE EXISTING MILITARY SEALS, POSTS, HARDWARE AND FOOTINGS. SALVAGE
SEALS FOR REINSTALLATION IN NEW LOCATION.
DEL4
REMOVE MECHANICALLY FASTENED MILITARY SEALS ONLY IF NECESSARY FOR
REFINISHING. SALVAGE ALL HARDWARE FOR REUSE
DEL5
EXISTING STAIR RAIL AND ROSTRUM GUARDRAILS TO REMAIN IN PLACE; SEE FLOOR
PLAN FOR REFINISHING OF THESE ELEMENTS.
T.O FLOOR SLAB
100'-0"
DEL1
DEL5
DEL3
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
3'
-6
DEL4
TOP OF GRADE
DEL5DEL5
T.O FLOOR SLAB
100'-0"
DEL1
DEL3DEL4 DEL3DEL3 DEL4
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
'-6
TOP OF GRADE
DEL5DEL5 DEL5
T.O FLOOR SLAB
100'-0"
DEL1
DEL5
DEL3
DEL4
DEL2
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
'-6
TOP OF GRADE
DEL5DEL5
T.O FLOOR SLAB
100'-0"
EL3
EL8
EL1
TOP OF GRADE
(E X
IS
T
IN
G
V
IF
4'
-6
/2
T O
T O
P O
F W
O O
D F
A S
3'
-6
EL5
DEMOLITION ELEV SYMBOLS
KEY NOTE
A
GRIDLINE
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
DASHED LINE
INDICATES ITEM TO
BE REMOVED (UNO)
DE10
AREA OF DEMO
NIC
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
COST ESTIMATING:
OCMI
2100 NORTH GREENVILLE AVENUE
SUITE 1150
RICHARDSON, TX 75082
469.431.0571
RAYMOND BODO
FIRE / L0W VOLTAGE / SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER / PETE MCGHEE
CHRISTINA MCDANIEL
06/15/2026
52909
C U s e rs
\c z u p a n
\D o c u m e n ts \1
-R O
S T
R U
M -A
-R c z u p a n
J A
M E
X .r v t
/1
/2
:4
:0
P
M
4101- AE201
ROSTRUM - EXTERIOR ELEVATIONS FT BLISS NATIONAL CEMETERY
EXPANSION
5200 FRED WILSON AVE, EL PASO,TX
886CM3026
JUNE 15, 2026 CM RG
18528
1/4" = 1'-0"
EXTERIOR ELEVATION - SOUTH
1/4" = 1'-0"1
EXTERIOR DEMOLITION ELEVATION - NORTH
0 4' 8'2' 0 4' 8'2'
0 4' 8'2'
0 4' 8'2' 1/4" = 1'-0"
EXTERIOR ELEVATION - WEST
1/4" = 1'-0"
EXTERIOR ELEVATION - EAST
0 4' 8'2'
1/4" = 1'-0"
EXTERIOR ELEVATION - NORTH
0 4' 8'2'
1/4" = 1'-0"2
EXTERIOR DEMOLITION ELEVATION - EAST
0 4' 8'2' 1/4" = 1'-0"3
EXTERIOR DEMOLITION ELEVATION - SOUTH
0 4' 8'2' 1/4" = 1'-0"4
EXTERIOR DEMOLITION ELEVATION - WEST
0 4' 8'2'
1/4" = 1'-0"9
BUILDING SECTION
Revisions: Date: 104 of 155
File details come from the government source that posted it. Updated .