3004-E-111_ADD1.pdf
PDF 339 KB Posted
- Solicitation number
- 36C78626B0028
About this file
This is an Electrical Lighting Plan for a restroom expansion project at Fort Bliss National Cemetery in El Paso, Texas. The drawing, numbered 3004-E-111, is dated June 15, 2026, and prepared by ANDERSON as the Designer of Record, with IMEG serving as the Low Voltage/Security and Fire Alarm consultant. The project involves installing electrical lighting and associated components in a new restroom facility that is not sprinklered.
The electrical scope includes installation of lighting fixtures, hand dryers (men's and women's), refrigeration units, exhaust fans, controllers, water heaters, heat pumps, fire control systems, water fountains, and receptacles with ground fault protection (GFI). All devices will connect to an existing NEMA 1 surface-mounted panelboard (PANEL A) rated at 250 amperes, 208 volts three-phase, with a 225-ampere main breaker and 10 kA short circuit current rating. General notes specify that surface raceway is prohibited in finished areas without design team approval, lighting fixtures must remain accessible without ceiling cutting, wall-mounted fixtures require design team approval of rough-in locations, and all work must coordinate with architectural elevations and reflected ceiling plans prior to rough-in. Existing light switches will be reinstalled after architectural work completion with coordination for new door openings.
View the file
Other files
Show 40 more
Latest 50 of 52 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EX
EX EX
EX
EX
EX
EX
EX
EX
EX
EX
EX EX EX
EX
EX
EX
EX
EX
EX
EX
E1
A
EXR
E2
PANEL A
EX EX
ELECTRICAL GENERAL NOTES
1. NOT USED.
2. SURFACE RACEWAY SHALL NOT BE USED IN ANY FINISHED AREAS WITHOUT
PRIOR APPROVAL OF THE DESIGN TEAM.
3. INSTALL DEVICES SUCH THAT NO TWO DEVICES ON OPPOSITES SIDES OF THE
SAME WALL ARE WITHIN 6" OF EACH OTHER.
4. COORDINATE ALL DEVICES WITH ARCHITECTURAL PLANS AND CASEWORK.
5. ALL LIGHTING FIXTURES SHALL BE INSTALLED IN SUCH A WAY THAT DRIVERS ARE
ACCESSIBLE WITHOUT CUTTING OF CEILING. THE DESIGN TEAM SHALL BE
NOTIFIED IMMEDIATELY OF AREAS WHERE THIS IS NOT POSSIBLE.
6. ALL WALL-MOUNTED FIXTURES SHALL HAVE THEIR EXACT ROUGH-IN LOCATION
DETERMINED BY THE DESIGN TEAM PRIOR TO ROUGH-IN.
7. UNLESS NOTED OTHERWISE BY DESIGNATED LIGHTING CONTROL ZONES,
SWITCHES SHOWN SHALL CONTROL ALL FIXTURES IN THE ROOM.
8. REFER TO ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS FOR
THE SPECIFIC DEVICE ROUGH-IN AND PLACEMENT. ANY DEVIATIONS FROM THE
ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS SHALL BE
REVIEWED AND APPROVED BY THE DESIGN TEAM PRIOR TO ROUGH-IN.
ELECTRICAL PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
E1 NO ELECTRICAL SCOPE IN THIS AREA.
E2
REINSTALL EXISTING LIGHT SWITCH AFTER ARCHITECTURAL WORK HAS
BEEN COMPLETED. CLEAN AND INSPECT ALL COMPONENTS. COORDINATE
WITH NEW DOOR OPENING.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
C
U s e rs
\a w e b e r\
D o c u m e n ts \1
-P
IC
R
E S
T R
O O
M -M
-2 a w e b e r9
S
.r v t
/1
/2
:5
:4
P
M
3004-E-111
PIC/RESTROOM - ELECTRICAL PLANS FT BLISS NATIONAL CEMETERY
EXPANSION
5200 FRED WILSON AVE, EL PASO, TX
886CM3026
JUNE 15, 2026 ATW DIL
18528
1/4" = 1'-0"
ELECTRICAL LIGHTING PLAN
Notes: G=GFI M=MOTORIZED E=EXISTING ST=SHUNT TRIP A=ARC FAULT H=HANDLE LOCK
Demand Current: 0 A
Demand Load: 0 kVA
Connected Current: 0 A
Connected Load: 0 kVA
Panel Totals
Load Classification Connected Factor Demand
Connected Current: 0 A 0 A 0 A
Connected Load: 0 kVA 0 kVA 0 kVA
A-41 A-42
A-39 FLAG POLE LIGHTS SOUTH 20 1 E 0 0 A-40
A-37 FLAG POLE LIGHTS NORTH 20 1 E 0 0
E 2 15 MEN DYSON DRYER
A-38
A-35 A-36
A-33 0 0 A-34
A-31
MENS HAND DRYER 20 2 E
0 0
E 2 60 REF. UNIT
A-32
A-29 A-30
A-27 0 0 A-28
A-25
WOMENS HAND DRYER 20 2 E
0 0
E 2 60 REF. UNIT
A-26
A-23 A-24
A-21 CONTROLLER #2 20 1 E 0 0 E 1 20 CONTROLLER #3 A-22
A-19 ER #2 20 1 E 0 0 E 1 20 EXHAUST FAN A-20
A-17 A-18
A-15 0 E 1 20 NEW HEAT PUMP A-16
A-13 WATER HEATER 20 1 E 0 0 E 1 20 GFI A-14
A-11 A-12
A-9 FIRE CONTROL 20 1 E 0 0 E 1 20 WATER FOUNTAIN A-10
A-7 OUTSIDE/INSIDE SITTING LIGHTS 20 1 E 0 0 E 1 20 RESTROOM GFI RECEPTS A-8
A-5 A-6
A-3 RESTROOMS LIGHTING 20 1 E 0 0 E 1 20 OUTSIDE GFI RECEPTS A-4
A-1 LIGHTING 20 1 E 0 0 E 1 20 COMPUTER GFI RECEPTS A-2
Ckt Description Trip (A) Poles FN/Note Phase A
Load (VA) Phase B
Load (VA) Phase C
Load (VA) FN/Note Poles Trip (A) Description Ckt
NOTES: EXISTING PANELBOARD TYPE PRL-1A
Enclosure: NEMA 1
Mounting: Surface Features & Modifications: -
Supply: Feed-Thru Lugs: No SCCR: 10 kA
Location: EXISTING HVAC 106 Neutral: 100% Mains FN/Note: -
Bus Rating: 250 A Mains Rating: 225 A
Panelboard: PANEL A Voltage: 208 V, 3Ø, 4W Mains Type: MCB
A MANUAL ON/OFF MANUAL LINE VOLTAGE TOGGLE SWITCH N/A
TAG ACTIVATION DECRIPTION SCHEDULE
LIGHTING CONTROL - SEQUENCE OF OPERATION
Revisions: Date:
Addendum 1 10/12/2026
| Sheets |
| 3004-E-111 - PIC/RESTROOM - ELECTRICAL PLANS |
| 3004-ED111 - PIC/RESTROOM - ELECTRICAL DEMOLITION PLANS |
File details come from the government source that posted it. Updated .