This document is an architectural floor plan for the basement level of an Administration Building at Fort Bliss National Cemetery in El Paso, Texas, part of a facility expansion project. The drawing (2101-AE101) is issued as Bid Documents dated June 15, 2026, with an addendum dated October 12, 2026, prepared by Anderson, the Designer of Record, under the U.S. Department of Veterans Affairs Office of Construction and Facilities Management.
The basement floor plan specifies construction work including installation of fire-rated plywood wall protection (4'-0"W x 8'-0"H x 3/4" AC grade), recessed fire extinguisher cabinets for CO2 units, a wire mesh hinged door (3'-0" x 6'-10") with access control, fire-rated horizontal shaft partitions, cast-in-place concrete equipment pads, telecom enclosures, security panels, credential readers, and key storage cabinets with credential reader capability. Additional work includes patching and finishing of disturbed areas to match existing surfaces, reinstallation of existing equipment and components, removal and refinishing of hand and stair rails with chemical paint removal and rust treatment, and restoration of stucco work. The document references coordination with mechanical, electrical, plumbing, and technology subcontractors regarding equipment dimensions, existing utilities, and support fabrication. General notes emphasize that incidental work outside principal construction areas must be included in the contract, that dimensions are basis-of-design specifications requiring verification, and that all work must restore rated construction integrity and finishes to like-new condition. Consultant design team includes IMEG for fire and low-voltage security systems, Aqua Engineering for irrigation, Terracon for geotechnical work, and OCMI for cost estimating.
View the file
Other files
Show 40 more
Latest 50 of 52 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING
RECORDS
STORAGE
EXISTING
STORAGE/ELEC/OIT
FL5
FL6
UNEXCAVATED
FL13 FL14
UP
FL18
FL19
SHELF
S H
E
LF
WH
FL8
FL15
FLOOR PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FL1
4'-0"W x 8'-0"H X 3/4" AC GRADE FIRE RATED PLYWOOD. CUT PANELS AS
NECESSARY TO FIT ROOM. 2 COATS OF FIRE RESISTANT PAINT ALL SIDES
AND TOP WITH COAT OF HIGH GLOSS WHITE. MOUNT BOTTOM OF
PLYWOOD 1'-0" AFF
FL2 WALL - MOUNT TELECOM ENCLOSURE, SEE TECHNOLOGY
FL3 SECURITY PANEL - SEE TECHNOLOGY
FL4
FULLY RECESSED 1HR FIRE RATED FIRE ESTINGUISHER CABINET FOR NEW
CO2 EXTINGUISHERS. SEE SIMILAR DETAIL 4/2101- AE601 FOR MORE
INFORMATION.
FL5 EXISTING MECHANICAL CHASE
FL6 EXISTING CAST-IN-PLACE CONCRETE FOUNDATION WALL
FL7 S-1 COUNTERTOP
FL8 CREDENTIAL READER - SEE TECHNOLOGY
FL9
1-HR FIRE RATED HORIZONTAL SHAFT PARTITION FULL EXTENT OF ROOM.
BOTTOM OF GYPSUM BOARD FINISH AT 8'-6" AFF.
FL10
EXISTING FLUE REINSTALL ONCE STUCCO AND PAINT WORK IS COMPLETE
IF REMOVED TO COMPLETE REFINISHING WORK
FL11 EXISTING CONCRETE RAMP, LANDINGS AND STAIR TO REMAIN
FL12
CIP CONCRETE EQUIPMENT PADS, COORDINATE EXACT LOCATION WITH
THE VA DURING SHOP DRAWING REVIEW – SEE CIVIL AND MECHANICAL
FL13 EXISTING FIRE EXTINGUISHER
FL14
WIRE MESH HINGED DOOR 3'-0" X 6'-10". (CUSTOM DOOR SIZE MAY BE
REQUIRED TO FIT EXISTING CONSTRUCTION AT NO ADDITIONAL COST TO
THE VA), HARDWARE SET HW-G1. EXISTING CLNG HT IS 7'-0"; HOWEVER,
SPACE NEEDS TO BE MADE ABOVE DOOR TO AVOID HITTING CEILING
MOUNTED CONDUIT. FIELD VERIFY SPACE AVAILABLE FOR FULLY
FUNCTIONAL ACCESS CONTROLLED DOOR OPENING PRIOR TO
SUBMITTING SHOP AND ERECTION DRAWINGS.
FL15
PATCH WALLS AND STAIR WITH FINISH TO MATCH EXISTING WHERE
EXISTING DOOR WAS DEMOLISHED.
FL16 RELOCATED EXISTING PAPER SHREDDER
FL17
PROVIDE NEW 3" METAL DOWNSPOUT, SCALLOPED PROFILE TO MATCH
EXISTING
FL18 EXISTING CRAWL SPACE ACCESS DOOR
FL19
EXISTING ELEC AND BUILDING SYSTEM PANELS - SEE ELECTRICAL,
TECHNOLOGY
FL20
SECURE KEY STORAGE CABINET WITH CREDENTIAL READER CAPABILITY -
SEE TECHNOLOGY, COORDINATE FINAL LOCATION WITH CEMETERY
DIRECTOR
FL21 REINSTALL AWNING POSTS REMOVED DURING DEMOLITION
FL22
PRIOR TO REINSTALLATION, USING CHEMICAL METHODS, REMOVE PAINT
FROM THE HAND AND STAIR RAILS AND ASSOCIATED HARDWARE ON SITE.
REMOVE RUST WITH A RUST NEUTRALIZER BEFORE PRIMING. APPLY
PRIMER, INTERMEDIATE AND TOP PAINT COATS TO HANDRAILS AND
ASSOCIATED HARDWARE (P-9).
FL23 DASHED LINE DENOTES EDGE OF ROOF OVERHANG ABOVE
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING ELECTRICAL, MECHANICAL, PLUMBING AND
OTHER SYSTEMS. THIS INCIDENTAL WORK MUST BE PART OF THIS CONTRACT.
INSPECT THESE AREAS TO ASCERTAIN WORK REQUIRED AND PERFORM THE WORK IN
ACCORDANCE OF CONTRACT REQUIREMENTS.
2. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.
3. PATCH OPENINGS CUT THOUGH RATED CONSTRUCTION WITH MATERIALS
COMPATIBLE WITH EXISTING ASSEMBLY TO RESTORE INTEGRITY OF THE RATING.
RESTORE FINISHES OF DISTURBED AREAS TO LIKE NEW CONDITION.
4. GENERAL CONTRACTOR TO CHECK MECHANICAL DRAWINGS FOR EXISTING PIPES AND
DUCTS FURRED IN WALLS. VERIFY SIZE AND LOCATION WITH MECHANICAL
CONTRACTOR PRIOR TO PROCEEDING WITH REMODELING.
5. DIMENSIONS OF EQUIPMENT ARE THOSE OF THE BASIS-OF-DESIGN EQUIPMENT.
VERIFY DIMENSIONS OF ACTUAL EQUIPMENT BEING PROVIDED TO COORDINATE SPACE
REQUIREMENTS.
6. VERIFY DIMENSIONS OF MECHANICAL OR ELECTRICAL EQUIPMENT PRIOR TO
FABRICATING SUPPORTS FOR THE EQUIPMENT.
7. PATCH AREAS DISTURBED OR MODIFIED BY THIS WORK WITH MATERIALS TO MATCH
EXISTING ADJACENT SURFACES OR SCHEDULED FINISHES AND TO A LIKE NEW
CONDITION.
8. PROVIDE ACCESS PANELS WHERE INDICATED ON DRAWINGS AND WHERE DESCRIBED
IN SPECIFICATIONS SECTION 08 31 13. COORDINATE LOCATIONS AND SIZES REQUIRED
(24" X 24" MINIMUM) WITH MECHANICAL, PLUMBING, ELECTRICAL AND TECHNOLOGY
SUBCONTRACTORS.
9. ABBREVIATIONS AND SYMBOLS OF ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND
ELECTRICAL MAY VARY BY DISCIPLINE. SEE RESPECTIVE DISCIPLINE SECTIONS AND/OR
DRAWINGS FOR DEFINITIONS.
10. AT MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, PROVIDE 3/4" FIRE
RETARDANT TREATED (FRT) PLYWOOD SURFACE OF SCHEDULED PARTITION FOR
SURFACE MOUNTED FIXTURES AND EQUIPMENT, UNLESS NOTED OTHERWISE. DO NOT
PAINT OVER FRT LABEL.
11. DEFINITIONS OF COMMON TERMS.
• FURNISH: TO SUPPLY AND DELIVER TO THE SITE, READY FOR INSTALLATION
• INSTALL: TO PLACE INTO POSITION SERVICE OR USE
• PROVIDE: TO FURNISH AND INSTALL
12. SEE TECHNOLOGY FOR MORE INFORMATION ABOUT CREDENTIAL READERS (CR)s.
13. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL STRUCTURES, EQUIPMENT,
AND VEGETATION (SUCH AS TREES, SHRUBS, AND GRASS) ON OR ADJACENT TO THE
WORK SITE, WHICH ARE NOT TO BE REMOVED AND WHICH DO NOT UNREASONABLY
INTERFERE WITH THE WORK REQUIRED UNDER THIS CONTRACT. REFER TO GENERAL
REQUIREMENTS SPECIFICATION SECTION 010002.
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
EXISTING DOOR
AND FRAME TO
REMAIN
DOOR
INTERIOR
BORROWED LITE
101B
101A
8'-0"
DIMENSION LINE
8'-0" EXTENDED
DIMENSION LINE
AE2111A
INTERIOR
ELEVATION
INDICATOR TAG
2B
XXXX-
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR SPOT
ELEVATIONWALL TAG
OFFICE
ROOM NAME AND
NUMBER
DETAIL REFERENCE
TAG
EXTERIOR SECTION
REFERENCE TAG
INTERIOR SECTION
REFERENCE TAG
KEY NOTE
A GRIDLINE
REVISION TAG
PR01
REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
B3
CURTAIN WALL TAG
OR WINDOW TAGCW1 W3OR
LIMITS OF
CONSTRUCTION
XXXX-
AE2O1
1A
XXXX-
AE2O1
1A
XXXX-
AE2O1
1A
INSTALL 7/8" THICK 3-
COAT DIRECT APPLIED
STUCCO ON WALL IN
IT'S ENTIRETY, IN
ADDITION TO ALL
STUCCO ON
ENTRANCE OVERHANG
AND COLUMNS
NIC
AREA IN
DESIGNATED FOR
TECHNOLOGY
ENCLOSURE
MATERIAL LEGEND
EXISTING
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
BRICK
BRICK
CONCRETE
GYPSUM BOARD
GRAVEL / FILL
PLYWOOD
EARTH
PLAN & SECTION SECTION
ELEVATION
NEW CONSTRUCTION
CMU
RIGID INSULATION
SPRAY FOAM
STONE WOOD - HORIZONTAL
WOOD - VERTICALFIRE PROOFING
CMU
CONCRETE
METAL
MORTAR NET
SOLID SURFACE
BATT INSULATION
EXISTING STUCCO
STUCCO
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
COST ESTIMATING:
OCMI
2100 NORTH GREENVILLE AVENUE
SUITE 1150
RICHARDSON, TX 75082
469.431.0571
RAYMOND BODO
FIRE / L0W VOLTAGE / SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER / PETE MCGHEE
CHRISTINA MCDANIEL
06/15/2026
52909
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
-A D
M
IN
-A -R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/1 /2
:3
:1
A M
2101- AE101
ADMIN BLDG - BASEMENT FLOOR PLAN FT BLISS NATIONAL CEMETERY
EXPANSION
5200 FRED WILSON AVENUE, EL PASO,TEXAS
886CM3026
JUNE 15, 2026 CM RG
18528
1/4" = 1'-0"
BASEMENT FLOOR PLAN
0 4' 8'2'
Revisions: Date:
. Addendum 1 10/12/2026