This document is a comprehensive set of technical bid documents and construction drawings for the Fort Bliss National Cemetery Expansion project located at 5200 Fred Wilson Avenue, El Paso, Texas. The project is sponsored by the U.S. Department of Veterans Affairs, Office of Construction and Facilities Management, and includes detailed specifications for low voltage/security, fire alarm, technology, and related infrastructure systems.
The technology scope encompasses communications infrastructure including telecommunications rooms (TE/1 and TE/2), fiber optic connectivity, network switches, modular patch panels, cable management systems, and bonding/grounding equipment. Specific equipment required includes SC-series components (grounding busbars, cable trays, terminal boards, UPS systems), network switches, fiber optic panels with LC connectors, and 25-pair copper and 6-strand fiber connections between buildings. The project also requires video surveillance systems with five megapixel cameras (VS-CM-1 model), a video management server, and KVM equipment for monitoring. Access control and intrusion detection systems are specified with integrated components including credential readers, door position switches, glass break sensors, motion detectors, and audible/visual alarm devices. Fire alarm systems must include addressable control panels, smoke/heat detectors, manual pull stations, and notification appliances with selectable tones and strobe ratings. All cabling specifications call for Category 6A plenum-rated horizontal cables, proper conduit routing in EMT or surface-mount raceway, and compliance with telecommunications bonding standards. The installation requires coordination across multiple building locations (Administration Building, Maintenance Building, PIC/Restroom Building) with seismic restraint provisions, firestop requirements, and adherence to 2024 IBC and IFC codes.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
C
R1
R1
T301
EXISTING TELECOM WALL FIELD.
LEVEL 01
100'-0"
LEVEL 01
100'-0"
FIRST LEVEL
100'-0"
WALL HEIGHT
106'-0"
2" CONDUIT
FIBER PATCH CORD
NETWORK
SWITCH
WAP FOR FIRE
ALARM PANEL
25-PAIR COPPER TO
ADMIN BLDG
COPPER
PROTECTION
MODULE
MODULAR PATCH
PANEL
NETWORK SWITCH
INTRUSION
DETECTION
SYSTEM WITH
WIRELESS
(2) 6-STRAND FIBERS
TO ADMIN BLDG
EXISTING TELECOM
WALL FIELD
FIBER OPTIC
PANEL
TE
SC-GND-2SC-CAB-2
(TYP.)
T301
AC-SCP-1
+84"
SC-TTB
CM-1
01-07
TE
(TYP OF 2)
PW-CPW-1
SC-CT-1
12"x4"
SC-CT-1
SC-LR-1
12"x1 1/2"
SC-LR-1
SC-LR-1
12"x1 1/2"
SC-LR-1
(TYP)
(TYP)
(TYP)
LEVEL 01
100'-0"
LEVEL 02
110'-0"
LEVEL 01
100'-0"
LEVEL 02
110'-0"
FIRST LEVEL
100'-0"
WALL HEIGHT
106'-0"
CEILING HEIGHT
110'-0"
AC-SCP-1
SC-CAB-2
SC-GND-2
SC-LR-1
12"x1 1/2"
SC-LR-1
SC-CT-1
12"x4"
SC-CT-1
SC-TTB
SC-FDC-1 SC-GND-3
SC-HWM-1
SC-MPP-1
GFGI NETWORK SWITCH
SC-HWM-1
SC-UPS
SC-PDU-1
SC-PDU-1
+84"
SC-NS-1
SC-UPS 3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
JUNE 15, 2026
A u to d e s k D o c s
/2
.0
V A
N C
A F t B lis s c a m p u s E x p a n s io n /E
T
.0
V
A N
C A
-1
-M
A
IN
T C
.r v t
/1
/2
:5
:2
A
M
T301
TECHNOLOGY ENLARGED PLANS FT BLISS NATIONAL
CEMETERY EXPANSION
5200 FRED WILSON AVE, EL PASO,TX
886CM3026
PETMCG RICWHI
18528
N O R
HT
1/2" = 1'-0"1
EXISTING EQUIPMENT ROOM LAYOUT
1" = 1'-0"2
EXISTING TELECOM WALL FIELD ELEVATION
N O R
HT
1/2" = 1'-0"3
COMMUNICATIONS ROOM EQUIPMENT LAYOUT - TE/2
N O R
HT
1/2" = 1'-0"4
COMMUNICATIONS ROOM PATHWAY LAYOUT - TE/2
1" = 1'-0"5
COMMUNICATIONS ROOM RACK LAYOUT - TE/2
KEYNOTES:
1. SC-GND-3 TO BE MOUNTED ON REAR OF RACK AT TOP RACK MOUNTING LOCATION.
2. RACK SPACE RESERVED FOR FUTURE EQUIPMENT.
3. UPS RESERVED FOR SECURITY NETWORK SWITCH. CONTRACTOR TO SIZE UPS PER SPECIFICATIONS AND PROVIDE
FINAL PRODUCT SELECTION.
4. RACK MOUNT PDU. PDU'S ARE SHOWN IN THE FRONT BUT ARE TO BE INSTALLED ON THE BACK OF THE RACK RAIL.
CONNECT ONE PDU TO WALL POWER OUTLET. CONNECT ONE PDU TO UPS.
KEYNOTES:
1. INSTALL LADDER RACK VERTICALLY ON WALL BETWEEN SC-CAB-2 TO TOP OF SC-CT-1 ABOVE. REFER TO 5/T301 FOR
MORE INFORMATION.
2. INSTALL LADDER RACK VERTICALLY ON WALL FROM BASE OF TTB TO TOP OF SC-CT-1 ABOVE.
3. TWO (2) 2" CONDUITS PENETRATING WALL FROM HANDHOLE OUTSIDE. REFER TO CIVIL DRAWINGS CU102 FOR
CONDUIT CONTINUATION.
KEYNOTES:
1. MOUNT CAMERA TO UNDERSIDE OF CABLE TRAY.
NOTES:
1. REMOVE ALL LOW VOLTAGE CABLING AND DEVICES BACK TO ITS SOURCE AND REMOVE ALL EQUIPMENT.
COORDINATE WITH VA OIT FOR THE REMOVAL OF ALL TELEPHONE AND NETWORK EQUIPMENT PRIOR TO
CABLE REMOVAL.
KEYNOTES:
1. SWITCH LOCATED ON FILE CABINET ON ADJACENT WALL.
2. IDS SYSTEM LOCATED ON ADJACENT WALL.
NOTES:
1. REMOVE ALL LOW VOLTAGE CABLING AND DEVICES BACK TO ITS SOURCE AND REMOVE ALL EQUIPMENT.
COORDINATE WITH VA OIT FOR THE REMOVAL OF ALL TELEPHONE AND NETWORK EQUIPMENT PRIOR TO
CABLE REMOVAL.
Revisions: Date: 144 of 155
BASE BID
CABLE EXTENDS TO THE NEAREST
TELECOMMUNICATIONS ROOM
J-HOOK2
COILED CATEGORY
SLACKLOOP
VELCRO CABLE STRAP4
NOTES:
1. THIS DIAGRAM MAY NOT REPRESENT THE QUANTITY OF CABLES TO EACH
INFORMATION OUTLET JUNCTION BOX. REFER TO THE DRAWINGS AND THE
DATA CONNECTION SCHEDULE FOR ADDITIONAL INFORMATION.
2. ALL DEVICES ARE INSTALLED ABOVE THE CEILING UNLESS OTHERWISE
NOTED.
KEYNOTES:
1. 2-PORT PLENUM RATED SURFACE MOUNTED BOX, SUPPORT FROM J-HOOK.
REFER TO THE DATA CONNECTION SCHEDULE AND TECHNOLOGY EQUIPMENT
SCHEDULE FOR ADDITIONAL INFORMATION.
2. MOUNT A DEDICATED J-HOOK TO THE NEAREST CEILING SUBSTRUCTURE,
COLUMN, JOIST, OR WALL ABOVE THE CEILING AS SHOWN ON THE DRAWINGS.
PROVIDE THE PROPER SUPPORT WHEN HANGING FROM THE CEILING
SUBSTRUCTURE OR COLUMN WALL OR JOIST. REFER TO SPECIFICATION
SECTION 27 05 28 FOR ADDITIONAL REQUIREMENTS.
3. PROVIDE A MINIMUM 15' SLACKLOOP. MAINTAIN THE MANUFACTURERS BEND
RADIUS FOR SLACKLOOP SIZE.
4. PROVIDE AND INSTALL A VELCRO CABLE STRAP ON THE SLACKLOOP
APPROXIMATELY EVERY 6" ALONG THE SLACKLOOP. FOR SLACKLOOPS
GREATER THAN 3' A MINIMUM OF (4) STRAPS WILL BE INSTALLED.
1.97"
W
IDTH
DEPTH
3.94"
118.2"
PART # DEPTH (IN) WIDTH (IN)
CAT 6 4-PAIR
PLENUM (0.35")
CF 105/450 4 18 373
CF 150/450 6 18 536
1.
2.
GENERAL NOTES:
MOUNT AT +96" AFF. UNLESS OTHERWISE SPECIFIED.
REFER TO THE ABOVE TABLE FOR PART NUMBER BASED ON EXPECTED
LOADING.
MOLDED POLYESTER -
FIBERGLASS INSULATOR
TBC AND/OR TBB AND/OR BE AS
APPLICABLE PER LOCATION. REFER
TO TECHNOLOGY BONDING RISER
DIAGRAM AND SPECIFICATION
SECTION 27 05 26.
TWO HOLE
COMPRESSION LUG
NOTES:
1. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE SC-GND-2 FOR
MINIMUM DIMENSION REQUIREMENTS.
2. REFER TO TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM.
COPPER BONDING CONDUCTOR TO
EQUIPMENT RACKS, CABLE TRAYS
& METALLIC SLEEVES. REFER TO
SPECIFICATIONS FOR DETAILS
BARE COPPER GROUND BAR,
INSULATORS, BRACKETS AND
BONDING PROVIDED BY E.C.
REFER TO TECHNOLOGY
EQUIPMENT SCHEDULE SC-GND-2
5/16" Ø
(TYP)
7/16" Ø
(TYP)
LID SHALL BE MARKED
"COMMUNICATIONS"
MOUSE HOLES - (4).
CONDUIT ENTRY PENETRATION NOT TO
EXCEED 25 PERCENT OF SIDE WALL AREA
STAINLESS STEEL HEX
HEAD BOLT W/WASHER
PULL SLOT
SKID RESISTANT SURFACE
EXTENSIONS AS
REQUIRED BY
CONDUIT DEPTH
KNOCKOUTS - (8)
SLOPE GRADE AWAY
FROM COVER 1" IN 3'
GRAVEL DRAINAGE BED MINIMUM 6"
DEPTH. MINIMUM SIZE GRAVEL 1"
NOTES:
1. ALL DIMENSIONS ARE NOMINAL INSIDE CLEARANCES.
2. PROVIDE ALL ACCESSORIES AS NEEDED TO SECURE CABLE TO SIDE WALL.
3. REFER TO CIVIL DRAWINGS CU102 AND CU103 FOR ADDITIONAL INFORMATION ON CONDUIT QUANTITY.
8" E
XTENSIO
N
LOGO
LENGTH
W
IDTH
DEPTH
RACK BONDING CONDUCTOR (6 AWG)
UNIT BONDING CONDUCTOR (6 AWG)
TOP MOUNTED RACK BONDING BUSBAR
SC-GND-3
RACK BONDING
CONDUCTOR
(6 AWG)
IRREVERSIBLE
COMPRESSION
CONNECTIONTELECOMMUNICATION
EQUIPMENT BONDING
CONDUCTOR (6 AWG)
CABLE TRAY BONDING CONDUCTOR
TYPICAL AT EACH SECTION CONNECTION POINT
TO SC-GND-2
IRREVERSIBLE CRIMP
CONNECTOR
TELECOMMUNICATIONS
EQUIPMENT BONDING
CONDUCTOR
INDIVIDUAL BONDING CONDUCTORS
FROM EACH PIECE OF EQUIPMENT
AND RACK TO THE SC-GND-2
BUSBAR (TYP.)
TWO HOLE COMPRESSION LUG
IRREVERSIBLE CRIMP
CONNECTOR
TO SC-GND-2
BASKET TRAY
1.
2.
3.
GENERAL NOTES:
REFER TO 3/T400 BONDING BUS BAR DETAIL FOR ADDITIONAL INFORMATION.
REFER TO 2/T500 TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM FOR ADDITIONAL INFORMATION.
REFER TO T600 FOR TECHNOLOGY EQUIPMENT SCHEDULE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
JUNE 15, 2026
A u to d e s k D o c s
/2
.0
V A
N C
A F t B lis s c a m p u s E x p a n s io n /E
T
.0
V
A N
C A
-1
-A
D M
IN
C
.r v t
/1
/2
:4
:2
A
M
T400
TECHNOLOGY DETAILS FT BLISS NATIONAL
CEMETERY EXPANSION
5200 FRED WILSON AVE, EL PASO, TX
886CM3026
PETMCG RICWHI
18528
NO SCALE1
ABOVE CEILING INFORMATION OUTLET MOUNTING DETAIL
NO SCALE2
WIRE BASKET CAPACITY
NO SCALE3
BONDING BUS BAR DETAIL
NO SCALE4
EXTERIOR HAND HOLE DETAIL
NO SCALE5
PATHWAY, RACK, BONDING CONDUCTOR JOIN REQUIREMENT
Revisions: Date: 145 of 155
NYLON BUSHING
J-HOOK
GENERAL NOTES:
1. 1" EMT CONDUIT SHALL STUB UP TO NEAREST ACCESSIBLE CEILING AND TERMINATE ORIENTED
HORIZONTALLY AT THE HEIGHT OF THE ASSOCIATED J-HOOK ROUTE. CONDUIT RUN SHALL NOT
CONTAIN MORE THAN 180 DEGREES OF BEND BETWEEN ACCESSIBLE JUNCTION BOXES OR
BETWEEN JUNCTION BOX AND END OF CONDUIT.
2. WHERE CONDUIT STUB IS LOCATED IN A ROOM WITH AN ACCESSIBLE CEILING AND IS NOT REQUIRED
TO RUN TO CABLE ROUTE LOCATED OUTSIDE THE ROOM, STUB MUST TERMINATE ABOVE THE
ACCESSIBLE CEILING WITH A 90-DEGREE BEND AT THE TOP ORIENTED IN TO THE ROOM AT THE
HEIGHT OF THE ASSOCIATED J-HOOK ROUTE IN THE ROOM.
3. ALL STUBS MUST BE FITTED WITH A NYLON BUSHING ON EACH END OF THE CONDUIT.
4. INSTALLING CONTRACTOR SHALL FURNISH AND INSTALL FIRESTOP MATERIALS FOR TECHNOLOGY
ROUGH-INS PER PROJECT REQUIREMENTS. REFER TO SPECIFICATIONS FOR FIRESTOP
REQUIREMENTS.
KEYNOTES:
1. MOUNT A DEDICATED J-HOOK TO THE NEAREST CEILING SUBSTRUCTURE, COLUMN, JOIST, OR WALL
ABOVE THE CEILING. PROVIDE THE PROPER SUPPORT WHEN HANGING FROM THE CEILING
SUBSTRUCTURE OR COLUMN WALL OR JOIST. REFER TO THE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
2. MAINTAIN A MINIMUM OF 3' COIL SLACKLOOP.
3. PROVIDE AND INSTALL A VELCRO CABLE STRAP ON THE SLACKLOOP APPROXIMATELY EVERY 6"
ALONG THE SLACKLOOP. FOR SLACKLOOPS GREATER THAN 3' A MINIMUM OF (4) STRAPS WILL BE
INSTALLED.
VELCRO CABLE STRAP
CABLE EXTENDS TO THE NEAREST
TELECOMMUNICATIONS ROOM
COILED CATEGORY
SLACKLOOP
REFER TO ARCHITECTURAL
PLANS FOR WALL CONSTRUCTION
STUD
SINGLE GANG PLASTER RING
TO COME WITHIN 1/8" OF
FINAL SURFACE
NOTES:
1. CONFIGURATIONS SHOWN IN THE DETAIL ABOVE ARE DIAGRAMMATIC, INTENDED TO DESCRIBE THE CONTROLLED SECURITY SCHEME ROUGH-IN REQUIREMENTS OF THE DOORS. DETAILS ABOVE MAY NOT ACCURATELY REPRESENT DOOR SIZE, DOOR SWING, DOOR HARDWARE, OR DOOR FUNCTIONALITY. REFER TO ARCHITECTURAL DOOR HARDWARE SCHEDULE, DOOR HARDWARE GROUPS AND DOOR HARDWARE SPECIFICATIONS
FOR COMPLETE INFORMATION. MIRROR THE DETAIL AS REQUIRED.
2. ROUGH IN SHOWN IN THE DETAIL ABOVE REPRESENTS THE MINIMUM REQUIREMENTS FOR ALL CONTROLLED SECURITY SYSTEM DEVICES AND CABLING UNLESS OTHERWISE NOTED. COORDINATE EXACT REQUIREMENTS WITH SELECTED DOOR MATERIALS, DOOR HARDWARE, AND
CONTROLLED SECURITY DEVICES AND CABLING PRIOR TO INSTALLATION.
3. ALL CABLING IN WALLS AND WHERE EXPOSED ON VERTICAL SURFACES SHALL BE INSTALLED IN EMT CONDUIT OR SURFACE MOUNT RACEWAY.
CABLING ROUTED HORIZONTALLY ABOVE THE ACCESSIBLE CEILING MAY BE INSTALLED FREE-AIR CABLING PROPERLY RATED FOR THE CEILING
ENVIRONMENT.
4. THE ELECTRICAL OR SECURITY CONTRACTOR SHALL NOT MODIFY ANY FIRE RATED DOOR AND/OR DOOR FRAME. REFER TO THE ARCHITECTURAL DOOR SCHEDULE, DOOR HARDWARE SCHEDULE, AND DOOR HARDWARE SPECIFICATION FOR ADDITIONAL INFORMATION. MODIFICATION TO ANY FIRE RATED DOOR AND/OR FRAME WILL REQUIRE A RE-CERTIFICATION OF THE DOOR AND FRAME WITH THE LOCAL AUTHORITY HAVING
JURISDICTION (AHJ).
5. INSTALLING CONTRACTOR SHALL FURNISH AND INSTALL FIRESTOP MATERIALS FOR ALL CONTROLLED SECURITY SCHEME ROUGH-INS PER PROJECT REQUIREMENTS. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
6. REFER TO THE CONTROLLED SECURITY SCHEME SCHEDULE ON T600 FOR ADDITIONAL INFORMATION.
7. INSTALLATION SHALL INCLUDE ALL POWER REQUIRED FOR SYSTEM OPERATION INCLUDING +120VAC. REFER TO THE SUGGESTED MATRIX OF SCOPE
RESPONSIBILITY FOR ADDITIONAL INFORMATION.
KEYNOTES:
1. PROVIDE JUNCTION BOXES IN THE DOOR FRAME WHERE SHOWN ON THIS DETAIL. ROUGH-IN SHALL BE PROVIDED WHETHER THE CURRENT SECURITY SCHEME UTILIZES THEM OR NOT. ALL CONDUITS SHALL BE EMT CONDUIT UNLESS OTHERWISE NOTED. FLEXIBLE CONDUIT OF ANY TYPE WILL NOT BE ACCEPTED. COORDINATE INSTALLATION WITH ON-SITE DOOR FRAME INSTALLATION CONTRACTOR.
2. ALL DOOR POSITION SWITCHES ARE REQUIRED TO BE RECESSED UNLESS OTHERWISE NOTED. ELECTRIC HINGE MONITORS ARE NOT AN
ACCEPTABLE REPLACEMENT FOR THE RECESSED DOOR POSITION SWITCH.
3. 4" SQUARE BACKBOX WITH SINGLE GANG PLASTER RING. PROVIDE 2 1/2" DEEP MASONRY BOX WHERE APPLICABLE. REFER TO FLOOR PLAN(S) FOR
ACTUAL CREDENTIAL READER TYPE AND ROUGH-IN LOCATIONS.
4. CONDUIT SHALL ROUTE FROM THE CREDENTIAL READER TO THE SECURED SIDE OF THE DOOR. CONDUIT SHALL ROUTE TO THE NEAREST SECURITY
PANEL.
5. MOUNT A MINIMUM 4" SQUARE 2-1/8" DEEP JUNCTION BOX WITH BLANK COVER PLATE ON THE SECURED SIDE OF THE DOOR ABOVE ACCESSIBLE CEILING. INSTALLING CONTRACTOR SHALL SIZE THE JUNCTION BOXES PER SYSTEM INSTALLATION REQUIREMENTS AND APPLICABLE CODES.
MAINTAIN ACCESS TO THE JUNCTION BOX.
6. PROVIDE A HORIZONTALLY MOUNTED SINGLE GANG BACKBOX FOR THE REQUEST TO EXIT SENSOR. REFER TO THE CONTROLLED SECURITY
SCHEME SCHEDULE ON T600 FOR DOORS THAT REQUIRE THIS ROUGH-IN.
7. CONDUIT SHALL ROUTE TO THE NEAREST ACCESSIBLE CEILING. PROVIDE A NYLON BUSHING ON CONDUIT END.
DOOR FRAME ROUGH-IN DIAGRAM
(ALL SINGLE DOORS)
FINISHED ACCESSIBLE
CEILING
1/2" EMT CONDUIT
MINIMUM (TYP.)
FINISHED FLOOR
1" EMT CONDUIT
MINIMUM FOR DOOR
HARDWARE
POWER
SUPPLIES
3/4" EMT CONDUIT
MINIMUM TO ABOVE THE
ACCESSIBLE CEILING
CREDENTIAL READER
ROUGH-IN 3
REQUEST TO
EXIT DEVICE
ROUGH-IN
DOOR CONTACT
ROUGH-IN
4"
NOTES:
1. COORDINATE EXACT LOCATION ON SITE WITH WORK BY OTHER TRADES TO ENSURE
DESIRED VIEWING AREA AND SERVICE ACCESS AFTER COMPLETION OF PROJECT AND
TO MINIMIZE ANY POSSIBLE DAMAGE TO INSTALLED CAMERA OR ASSOCIATED CABLING.
2. PROVIDE CAMERA MOUNTING ACCESSORIES REQUIRED FOR A COMPLETE
INSTALLATION FROM THE SAME MANUFACTURER OF THE CAMERA AND APPROVED BY
THE MANUFACTURER FOR USE WITH THE SPECIFIC MODEL NUMBER OF CAMERA
INSTALLED.
ACCESSIBLE CEILING
CAMERA AS SPECIFIED
PROVIDE CADDY 512 SERIES
T-GRID BRIDGING SUPPORT,
OR APPROVED EQUAL
CAT 6A CABLE
SAFETY TIE WIRE
NOTES:
1. CONFIGURATIONS SHOWN IN THE DETAIL ABOVE ARE DIAGRAMMATIC, INTENDED TO
DESCRIBE THE EXISTING GARAGE DOOR SECURITY SCHEME. DETAILS ABOVE MAY NOT
ACCURATELY REPRESENT DOOR SIZE, DOOR HARDWARE, OR DOOR FUNCTIONALITY.
REFER TO ARCHITECTURAL DOOR HARDWARE SCHEDULE, DOOR HARDWARE GROUPS
AND DOOR HARDWARE SPECIFICATIONS FOR COMPLETE INFORMATION.
KEYNOTES:
1. DEDICATED 1" EMT CONDUIT ROUTED TO NEAREST CABLE TRAY.
2. STANDARD JUNCTION BOX, PROVIDE WITH 90 DEGREE FITTING.
3. PROVIDE TWO (2) 3/4" FLEXIBLE NONMETALLIC CONDUITS FROM JUNCTION BOX TO
DOOR POSITION SWITCH. COORDINATE CONNECTION FITTING AT BASE OF GARAGE
DOOR WITH FINAL APPROVED FROM SYSTEMS MANUFACTURER.
DPO SENSOR
GARAGE DOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
JUNE 15, 2026
A u to d e s k D o c s
/2
.0
V A
N C
A F t B lis s c a m p u s E x p a n s io n /E
T
.0
V
A N
C A
-1
-A
D M
IN
C
.r v t
/1
/2
:4
:3
A
M
T401
TECHNOLOGY DETAILS FT BLISS NATIONAL
CEMETERY EXPANSION
5200 FRED WILSON AVE, EL PASO, TX
886CM3026
PETMCG RICWHI
18528
NO SCALE1
TECHNOLOGY ROUGH-IN TO J-HOOK DETAIL
NO SCALE2
CONTROLLED SECURITY SCHEME DOOR ROUGH-IN DETAIL
NO SCALE3
ACCESSIBLE CEILING CAMERA MOUNT AND ROUGH-IN DETAIL
NO SCALE4
DOOR SENSOR J-BOX ROUGH-IN DETAIL
Revisions: Date: 146 of 155
SC-GND-2
NEAREST
ELECTRICAL
PANEL
BUILDING
STEEL
ACCESS
CONTROL
EQUIPMENT
METALLIC
CONDUITS AND
SLEEVES
RACK BONDING
BUSBAR (RBB)
LADDER RACK
(CONTINUOUS
BOND)
CABLE TRAY
(CONTINUOUS
BOND)
EQUIPMENT
CABINET
GROUND BAR
SC-GND-2
GROUND BAR SC-GND-2
SC-MPP-1
OWNER
PROVIDED
EQUIPMENT
SC-FDC-1
SC-MPP-1
OWNER
PROVIDED
EQUIPMENT
SC-FDC-1
VS-KVM-1
AC-SMS-1
VS-VMS-1
SC-NS-1
SC-NS-1
TELECOMMUNICATIONS
BONDING JUMPER (TBJ)
TELECOMMUNICATIONS ROOM (TYP) 1
TELECOMMUNICATIONS
BONDING JUMPER (TBJ)
NOTES:
1. THIS FLOW DIAGRAM IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS. THIS FLOW DIAGRAM IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND CONDUCTOR TYPE. ALL CONNECTIONS AND SYSTEM DEVICES SHOWN ARE TYPICAL AND NOT REPRESENTATIVE OF ACTUAL PROJECT QUANTITIES. REFER TO FLOOR PLANS AND ENLARGED FLOOR PLANS FOR ACTUAL QUANTITIES AND LOCATIONS OF DEVICES AND SPECIFIC ROUTING INFORMATION. REFER TO
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. ALL CONDUCTORS IN THE TECHNOLOGY BONDING SYSTEM MUST BE PLENUM RATED COPPER (GREEN OR MARKED WITH A DISTINCTIVE GREEN COLOR). REFER TO BONDING CONDUCTOR SIZING SCHEDULE FOR SIZING CRITERIA FOR CONDUCTORS.
REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
3. ALL BONDING CONDUCTORS MUST BE CONNECTED BY COMPRESSION LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMPRESSION CONNECTORS. SOLDER IS NOT AN ACCEPTABLE MEANS OF CONNECTION. SHEET METAL SCREWS MUST NOT BE USED TO CONNECT COMMUNICATIONS BONDING CONDUCTORS TO EQUIPMENT. WHERE NECESSARY, REMOVE PAINT AND/OR USE
PAINT-PIERCING WASHERS TO PROVIDE PROPER ELECTRICAL BOND AT ALL CONNECTIONS.
4. REFER TO 3/T400 FOR BONDING BUS BAR DETAIL AND ADDITIONAL INFORMATION AND REQUIREMENTS FOR SC-GND-2.
KEYNOTES:
1. REFER TO TELECOM ROOM REFERENCES SCHEDULE ON THE COVERPAGE T000 FOR TELECOMMUNICATIONS ROOM NUMBER AND
LOCATION INFORMATION.
2. INCLUDES HORIZONTAL AND VERTICAL CONDUIT SLEEVES FOR TECHNOLOGY CABLING.
3. BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT), TO ELECTRICAL ENTRANCE INTERSYSTEM BONDING TERMINATION.
REFER TO 3/T500 FOR TELECOMMUNICATIONS BONDING RISER DIAGRAM FOR CONTINUATION AND ADDITIONAL INFORMATION AND
REQUIREMENTS.
4. TELECOMMUNICATIONS BONDING BACKBONE (TBB) TO EXISTING GROUND BAR. REFER TO 3/T500 FOR TELECOMMUNICATIONS BONDING RISER DIAGRAM FOR CONTINUATION AND ADDITIONAL INFORMATION AND REQUIREMENTS.
5. REFER TO THE ELECTRICAL DRAWINGS FOR LOCATION.
6. PROVIDE SC-GND-3 RACK MOUNT TELECOMMUNICATIONS BONDING BUSBAR AT EACH EQUIPMENT RACK AND CABINET.
TELECOMMUNICATIONS
BONDING JUMPER (TBJ)
PRIMARY/SECONDARY
BONDING BUSBAR
(PBB/SBB)
CONDUCTOR
LENGTH IN FEET
BONDING CONDUCTOR SIZING SCHEDULE
MINIMUM ACCEPTABLE
SIZE - AWG
LESS THAN 13' 6
14' - 20' 4
21' - 26' 3
27' - 33' 2
34' - 41' 1
42' - 52' 1/0
53' - 66' 2/0
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF
MATERIALS. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND
CONDUCTOR TYPE. ALL CONNECTIONS AND SYSTEM DEVICES SHOWN ARE TYPICAL AND
NOT REPRESENTATIVE OF ACTUAL PROJECT QUANTITIES. REFER TO FLOOR PLANS AND
ENLARGED FLOOR PLANS FOR ACTUAL QUANTITIES AND LOCATIONS OF DEVICES AND
MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
2. ALL CONDUCTORS IN THE TECHNOLOGY BONDING SYSTEM SHALL BE MINIMUM SIZE OF
3/0 AWG PLENUM RATED COPPER (GREEN OR MARKED WITH A DISTINCTIVE GREEN
COLOR) UNLESS CONDUCTOR LENGTH IS LESS THAN 66 FEET. REFER TO BONDING
CONDUCTOR SIZING SCHEDULE FOR SIZING CRITERIA FOR CONDUCTORS LESS THAN 66
FEET IN LENGTH. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
3. ALL BONDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED BY
COMPRESSION LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMPRESSION
CONNECTORS. SOLDER IS NOT AN ACCEPTABLE MEANS OF CONNECTION. SHEET METAL
SCREWS SHALL NOT BE USED TO CONNECT COMMUNICATIONS BONDING CONDUCTORS
TO EQUIPMENT. WHERE NECESSARY, REMOVE PAINT AND/OR USE PAINT-PIERCING
WASHERS TO PROVIDE PROPER ELECTRICAL BOND AT ALL CONNECTIONS.
4. REFER TO 2/T500 FOR TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM.
5. REFER TO TELECOM ROOM REFERENCES SCHEDULE ON THE COVERSHEET T000 FOR
TELECOMMUNICATIONS ROOM NUMBER AND LOCATION INFORMATION.
KEYNOTES:
1. BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT). BCT SHALL BE THE SAME SIZE
AS THE TBB OR LARGER. REFER TO BONDING CONDUCTOR SIZING SCHEDULE FOR
SIZING REQUIREMENTS.
BASEMENT
ELECTRICAL ENTRANCE
INTERSYSTEM BONDING
TERMINATION
GROUNDING ELECTRODE
CONDUCTOR BY OTHERS
ELECTRICAL GROUNDING
ELECTRODE SYSTEM
GREATER THAN 301' 750 kcmil
FIRST
FLOOR
EXISTING
STORAGE/ELEC/OIT
ADMINISTRATION BUILDING
FIRST
FLOOR
ELECTRICAL ENTRANCE
INTERSYSTEM BONDING
TERMINATION
GROUNDING ELECTRODE
CONDUCTOR BY OTHERS
ELECTRICAL GROUNDING
ELECTRODE SYSTEM
MAINTENANCE BUILDING
(PBB)
TE/1
(SBB)
EXISTING OFFICE/ELEC
TELECOMMUNICATIONS
BONDING BACKBONE
(TBB) (TYP)
TELECOMMUNICATIONS
BONDING BACKBONE
(TBB) (TYP)
(TBB) (SBB)
TE/2
EXISTING BONDING
BUS BAR
EXISTING BONDING
BUS BAR
MAINTENANCE BUILDINGADMINISTRATION BUILDING
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN.
THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC
ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO FLOOR PLANS FOR QUANTITY OF CABLES AND JACKS TO BE INSTALLED AT EACH INFORMATION
OUTLET.
KEYNOTES:
1. CATEGORY 6A PLENUM RATED HORIZONTAL CABLE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
2. REFER TO THE INFORMATION OUTLET SCHEDULE ON T600 AND THE FLOOR PLANS FOR THE QUANTITY OF
CABLES AND JACKS TO BE INSTALLED AT EACH LOCATION.
3. CONTRACTOR PROVIDED GOVERNMENT INSTALLED PATCH CABLE. REFER TO SPECIFICATIONS.
4. CONTRACTOR PROVIDED AND INSTALLED PATCH CABLE. REFER TO SPECIFICATIONS.
5. 24-STRAND SINGLE MODE OPTICAL FIBER WITH LC CONNECTORS. EXTEND FIBER TO NEW
TELECOMMUNICATIONS ROOM TE/2 IN THE MAINTENANCE BUILDING AND TERMINATE ON NEW OPTICAL FIBER PANEL SC-FDC-1. COORDINATE FINAL LOCATION WITH OWNER PRIOR TO CABLE INSTALLATION.
6. HDMI CABLE.
7. CONTRACTOR PROVIDED AND INSTALLED PATCH CORD TO SUPPORT VIDEO SURVEILLANCE CAMERAS.
8. RACK OR CABINET AS DEFINED ON THE TELECOM ROOM LAYOUT. REFER TO THE TELECOM ROOM REFERENCES
MATRIX ON THE COVERPAGE FOR LOCATION.
9. REFER TO COVERPAGE AND FLOOR PLANS FOR TELECOMMUNICATIONS ROOM LOCATIONS.
10. INCOMING FIBER OPTIC CABLE FROM SERVICE PROVIDER EQUIPMENT IN BASEMENT.
11. REFER TO PIC BUILDING FLOOR PLANS FOR MORE INFORMATION.
12. INSTALL NEW NETWORK SWITCH (SC-NS-1) TO SUPPORT A NEW DEDICATED SECURITY NETWORK. CONNECT
VIDEO SURVEILLANCE AND ACCESS CONTROL SERVERS TO SECURITY NETWORK. INCLUDE IN BID ALL PROGRAMMING NECESSARY TO INSTALL AND CONFIGURE SECURITY NETWORK. TEST ALL DEVICES IN BOTH
BULDINGS TO ENSURE DEVICES ARE CONNECTED.
C#
C#
C#
C#
9 9
C#
PIC BUILDING 11
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
JUNE 15, 2026
A u to d e s k D o c s
/2
.0
V A
N C
A F t B lis s c a m p u s E x p a n s io n /E
T
.0
V
A N
C A
-1
-A
D M
IN
C
.r v t
/1
/2
:4
:3
A
M
T500
TECHNOLOGY DIAGRAMS FT BLISS NATIONAL
CEMETERY EXPANSION
5200 FRED WILSON AVE, EL PASO, TX
886CM3026
PETMCG RICWHI
18528
NO SCALE2
TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM
NO SCALE3
TECHNOLOGY BONDING RISER DIAGRAM - ADMIN/MAINT
NO SCALE1
FIBER AND COPPER CONNECTIVITY DIAGRAM
Revisions: Date: 147 of 155
AC-SCP-1
SC-MPP-1
ID-ICP-1
K1
M
AC-SMS-1
G
GB
DOOR HARDWARE
ADMINISTRATION BUILDING - TE/1
WALL MOUNTED
EQUIPMENT
EQUIPMENT RACK
1.
2.
3.
4.
5.
6.
7.
NOTES:
THIS RISER IS A DIAGRAMMATIC ND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIAL SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS, AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO THE FLOOR PLANS FOR MORE SPECIFIC ROUTING
INFORMATION. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
THIS INTEGRATED SYSTEM INCLUDES DEVICES FOR AN INTRUSION DETECTION SYSTEM AND AN ACCESS CONTROL SYSTEM. REFER TO THE SPECIFICATIONS FOR ADDITIONAL
INFORMATION .
ALL CABLING LISTED HERE ARE MINIMUM REQUIREMENTS. FINAL GAUGE AND QUANTITY IS BASED ON THE DISTANCE FROM THE NEAREST CONTROL PANEL AND THE NUMBER OF DOORS AT EACH LOCATION. CREDENTIAL READERS WILL OPEN A SINGLE DOOR WITH THE SECOND DOOR BEING MONITORED BY THE SYSTEM.
ALL ACCESS CONTROL EQUIPMENT AND DOOR HARDWARE WILL REQUIRE TO BE ON A MINIMUM OF 8 HOURS OF BATTERY TIME IN THE EVENT OF A POWER FAILURE. THIS INCLUDES ALL OF THE INPUT/OUTPUT CARDS, DOOR CONTROLLERS, ENDPOINTS (SUCH AS CARD READERS, MOTION DETECTIONS, AND DOOR POSITIONS SWITCHES), DOOR POWER SUPPLIES AND ALL OTHER DEVICES REQUIRED TO SUPPORT THE SYSTEM FUNCTIONALITY. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ALL DOORS REQUIRE ROUGH-IN AT ALL LOCATIONS. REFER TO 2/T401 FOR ROUGH-IN REQUIREMENTS.
THIS SYSTEM INCLUDES A SINGLE SYSTEM THAT IS CAPABLE OF PROVIDING CARD ACCESS AND INTRUSION DETECTION. COORDINATE WITH THE GOVERNMENT FOR PROGRAMMING REQUIREMENTS TO DISABLE THE ALARM SYSTEM. THE ALARM SYSTEM WILL BE DISABLED VIA A DEDICATED KEYPAD AND THE KEYPAD ON NAY CREDENTIAL
READER.
PROVIDE AND INSTALL SOFTWARE ON A NEW CONTRACTOR PROVIDED AND INSTALLED PC FOR AN ENROLLMENT STATION. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. REFER TO THE DRAWINGS FOR QUANTITY OF DOORS AND PROVIDE ONE CONNECTION FOR EACH LEAF DOOR.
REQUEST TO
EXIT
ELECTRONIC
LOCKING
HARDWARE
DOOR
POSITION
SWITCH
AC-R1-W
A
SC-NS-1
AC-ENROLL-1
DESK
KEYNOTES:
1. 18 AWG 2-CONDUCTOR UNSHIELDED CABLE TIED INTO THE DOOR POSITION SWITCH FOR ALL DOORS.
2. TYPICAL OF ALL DOORS AS SHOWN ON THE DRAWINGS. REFER TO THE CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON T600 AND SPECIFICATIONS FOR QUANTITY OF
DEVICES AT EACH LOCATION.
3. A MINIMUM OF 18 AWG 4-CONDUCTOR, UNSHIELDED CABLE. 2 CONDUCTORS WILL CONNECT TO THE ACCESS CONTROL SYSTEM AND THE REMAINING 2 CONDUCTORS WILL
CONNECT TO THE INTRUSION DETECTION SYSTEM. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
4. A MINIMUM OF 18 AWG 4-CONDUCTOR, UNSHIELDED CABLE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION
5. A MINIMUM OF 18 AWG 6-CONDUCTOR, UNSHIELDED CABLE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
6. CATEGORY 6 PATCH CABLE FROM THE ACCESS CONTROL SYSTEM TO THE SECURITY NETWORK. PATCH PANEL INSTALLED IN THE NEAREST TELECOM ROOM. REFER TO
TELECOM ROOM LAYOUTS ON 5/T300 AND 5/T301 FOR ADDITIONAL INFORMATION. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
7. NETWORK SWITCH SHARED WITH THE VIDEO SURVEILLANCE SYSTEM.
8. CATEGORY 6 PATCH CORD, REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
9. THE SECURITY MANAGEMENT SERVER WILL BE INSTALLED IN TELECOM 1-G (TR-1). COORDINATE FOR CONNECTION AND INSTALLATION REQUIREMENTS.
10. PROVIDED AND INSTALLED BY THE DOOR HARDWARE CONTRACTOR.
11. DOOR POSITION SWITCH WILL CONNECT TO BOTH THE ACCESS CONTROL AND INTRUSION DETECTION SYSTEM. REFER TO FLOOR PLANS AND SITE PLANS FOR ADDITIONAL
INFORMATION.
12. ADD ALL ADDITIONAL EXPANSION MODULES REQUIRED TO EXPAND THE INTRUSION DETECTION SYSTEM TO EACH BUILDING. THE ADMINISTRATION BUILDING WILL BE THE MAIN
INTRUSION PANEL. EXPANSION CAN UTILIZE THE COPPER AND FIBER BACKBONE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
13. COORDINATE WITH THE COR ON THE CONNECTION TO THE MONITORING SERVICE. PROVIDE ALL REQUIRED DEVICES TO NOTIFY THE MONITORING SERVICE PER THE MONITORING
SERVICE REQUIREMENTS.
14. REFER TO THE FLOOR PLANS FOR CREDENTIAL READER TYPE AND LOCATIONS.
15. COORDINATE WITH THE CONTRACTOR FOR THE LOCATION OF THE ENROLLMENT STATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
JUNE 15, 2026
A u to d e s k D o c s
/2
.0
V A
N C
A F t B lis s c a m p u s E x p a n s io n /E
T
.0
V
A N
C A
-1
-A
D M
IN
C
.r v t
/1
/2
:4
:3
A
M
T501
TECHNOLOGY DIAGRAMS FT BLISS NATIONAL
CEMETERY EXPANSION
5200 FRED WILSON AVE, EL PASO, TX
886CM3026
PETMCG RICWHI
18528
NO SCALE1
ACCESS CONTROL & INTRUSION DETECTION CONNECTIVITY DIAGRAM
Revisions: Date: 148 of 155
2-Port Faceplate
IDENTIFICATION
IDENTIFICATION
IDENTIFICATION
IDENTIFICATION
1 2
4-Port Faceplate
PAIR 3
PAIR 1PAIR 2 PAIR 4
WO WGO BL WBL G WBR BR
1 32 4 5 6 7 8
ANSI/TIA/EIA T568B
PIN/PAIR ASSIGNMENT
REFER TO SPECIFICATIONS FOR
IDENTIFICATION REQUIREMENTS (TYP.)
NUMBER INDICATES
FACEPLATE POSITION (TYP.)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
JUNE 15, 2026
A u to d e s k D o c s
/2
.0
V A
N C
A F t B lis s c a m p u s E x p a n s io n /E
T
.0
V
A N
C A
-1
-A
D M
IN
C
.r v t
/1
/2
:4
:3
A
M
T600
TECHNOLOGY SCHEDULES FT BLISS NATIONAL
CEMETERY EXPANSION
5200 FRED WILSON AVE, EL PASO, TX
886CM3026
PETMCG RICWHI
18528
THE EQUIPMENT LIST ABBREVIATIONS AND THE TECHNOLOGY EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING
SYSTEM.
CATALOG NUMBERS ARE NOT TO BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS. MANUFACTURER PROVIDED SHALL BE CONSISTENT WITH APPROVED MANUFACTURERS LISTED. "STANDARD COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE. ALL EQUIPMENT MUST MEET BUY AMERICAN REQUIREMENTS.
TECHNOLOGY EQUIPMENT SCHEDULE
EQUIPMENT LIST
ABBREVIATION EQUIPMENT LIST DESCRIPTION
MANUFACTURER AND
MODEL
AC-ENROLL-1 USB DESKTOP SMART CARD READER FOR ENROLLMENT AND CREDENTIAL MANAGEMENT APPLICATIONS. READER SHALL SUPPORT ISO 7816, USB CCID, PS/SC, AND HBCI STANDARDS, AND SHALL BE COMPATIBLE WITH CONTACT SMART CARD OPERATIONS INCLUDING SINGLE SIGN-ON, ONLINE BANKING, AND DIGITAL SIGNATURE APPLICATIONS. PROVIDE NATIVE CCID DRIVER SUPPORT FOR EASY INSTALLATION WITHOUT ADDITIONAL DRIVERS. READER SHALL INCLUDE DUAL-COLOR LED STATUS INDICATOR, USB 2.0 FULL SPEED INTERFACE, USB TYPE A CONNECTOR, AND 59.1" CABLE. HOUSING SHALL BE
ROBUST ABS PLASTIC. DIMENSIONS: 3.15"W X 2.64"D X 1.1"H.
REFER TO SPECIFICATION SECTION 28 13 00 FOR ADDITIONAL INFORMATION.
HID
R31210320-01
AC-R1-W KEYPAD CARD READER. PROVIDED AS INTEGRAL PART OF SECURITY MANAGEMENT SYSTEM. REFER TO CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON T600 FOR ADDITIONAL INFORMATION. CARD READERS SHOWN ON PLANS TO IDENTIFY INTENDED MOUNTING LOCATION. REFER TO THE SPECIFICATIONS FOR COMPLETE INFORMATION.
HID
SIGNO40K SERIES
AC-SCP-1 SECURITY MANAGEMENT SYSTEM CONTROLLER, FOR USE WITH INTEGRATED SECURITY MANAGEMENT SYSTEM, REFER TO
SPECIFICATION SECTION 28 13 00 FOR COMPLETE INFORMATION.
HOFFMAN
AC-SMS-1 ELECTRONIC ACCESS CONTROL SERVER.
REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
HONEYWELL
PRO-WATCH
ID-AL1-W WALL MOUNTED AUDIBLE SIREN TO NOTIFY OF A BREACH.
INSTALL DEVICE IN A 4" SQUARE BACKBOX WITH SINGLE GANG PLASTER RING. INSTALL 1" EMT CONDUIT TO THE NEAREST
SUPPORTING SECURITY PANEL.
WBOX
OE-1GANGSIRN
ID-GB1-C GLASS BREAK SENSOR, SURFACE MOUNT, CEILING, TAMPER RESISTANT.
WEIGHT: 4.5 OZ. DIMENSIONS: 4.25"D X 0.875" H. POWER: 6-18 VDC, 12mA TYPICAL AT 12VDC. ALARM RELAY: FORM C, 125mA MAX, 25VDC MAX. RANGE: 25' RADIUS. PROVIDE 18/4 AWG TO THE SECURITY PANEL. FIELD VERIFY LOCATION. PROVIDE ONE
(1) 711S ADDRESSABLE MODULE FOR EACH LOCATION.
HONEYWELL
FG-1625RT
ID-K1-W INTRUSION ALARM KEYPAD. ILLUMINATED 4-LINE DISPLAY LCD SHOWS ZONE INFORMATION. ECP BUS COMPATIBLE.
INSTALL KEYPAD IN A 4" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING WITH (1) 1" CONDUIT TO ABOVE
ACCESSIBLE CEILING.
REFER TO CONTROLLED SECURITY SCHEME DOOR ROUGH-IN DETAIL FOR MORE INFORMATION.
HONEYWELL
VISTA 6160
ID-MD1-W INTRUSTION DETECTION MOTION DETECTION SENSOR, WALL OR CEILING MOUNTABLE. DIMENSIONS: 3.5" X 5.25" (HEIGHT X DIAMETER). REQUIRES INPUT POWER: 6-15VDC, 8mA STANDBY, 60mA IN ALARM WITH LEDs ENABLED. DEVICE COMPLIES
WITH PART 15 OF THE FCC RULES.
FOR CEILING MOUNTED APPLICATIONS, PROVIDE WITH UNIVERSAL CEILING-MOUNT BRACKET.
BOSCH
SENSOR:
ISC-CDL1-WA15G
MOUNT:
B338
PA-J-4 JUNCTION BOX 12" X 12" HOFFMAN
ASE12X12X4NK
PW-CPW-1 4" X 4" FIREPROOF CABLE PATHWAY FOR WALLS UP TO 10" THICK STI
44 SERIES
PW-HH-1 HANDHOLE COMPOSITE POLYMER CONCRETE BODY AND COVER. STAINLESS STEEL HARDWARE BOLTED NON-SKID COVER RATED FOR 15,000LB. DESIGN LOAD OCCASIONAL NON-DELIBERATE VEHICULAR TRAFFIC. UNITS IN LANDSCAPED AREAS
SHALL BE GREEN IN COLOR. “COMMUNICATIONS” LOGO ON HANHOLE COVER.
PROVIDE UNITS/EXTENSIONS AS REQUIRED BY CONDUIT DEPTH. CONTRACTOR SHALL FIELD VERIFY QUANTITY AND
LOCATIONS. REFER TO DETAIL 4/T400 FOR ADDITIONAL INFORMATION.
HUBBELL/QUAZITE
PG2424BB24
PG2424HA00
CARSON INDUSTRIES
ARMORCAST
HIGHLINE PRODUCTS
SYNERTECH
SC-CAB-1 WALL MOUNTED ENCLOSED CABINET. DIMENSIONS: 48"H X 24"W X 30"D, (26RU) PROVIDES 26 1.75" MOUNTING SPACES.
THREE-PART SWING-OUT DESIGN. LOCKABLE. SOLID METAL DOOR. REAR PANEL INCLUDES 1" AND 3" KNOCKOUTS. UL
LISTED. 19" PANEL MOUNTING. 300LB LOAD CAPACITY.
CHATSWORTH
CUBE-IT
11996-X48
SC-CAB-2 WALL MOUNTED ENCLOSED CABINET. DIMENSIONS: 36"H X 24"W X 30"D, PROVIDES 19 1.75" MOUNTING SPACES.
THREE-PART SWING-OUT DESIGN. LOCKABLE. SOLID METAL DOOR. REAR PANEL INCLUDES 1" AND 3" KNOCKOUTS. UL
LISTED. 19" PANEL MOUNTING. 300LB LOAD CAPACITY.
CHATSWORTH
CUBE-IT
11996-X36
SC-CT-1 CABLE TRAY, WIRE MESH TYPE, 12" LOADING DEPTH, 4" WIDTH, COMPLETE WITH ALL FITTINGS AND MOUNTING HARDWARE.
PROVIDE TRAPEZE SUPPORT WITH PLASTIC RETAINER. CUTTING OF THE MESH CABLE TRAY SHALL BE DONE WITH OFFSET BOLT CUTTERS ONLY. 10' MAXIMUM SUPPORT SPAN. EITHER SPLICE WASHERS OR TERMINAL GROUND SUPPORT AND JUMPER WIRE SHALL BE USED TO ATTAIN GROUNDING CONTINUITY THROUGHOUT. Z-BRACKETS SHALL BE USED FOR WALL MOUNTED APPLICATIONS. REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND SPECIFICATION SECTION 27 05 36 FOR ADDITIONAL INFORMATION. REVER TO 5/T400 FOR PATHWAY, RACK, AND BONDING CONDUCTOR JOIN
REQUIREMENTS. REFER TO 2/T400 FOR EXPECTED CABLE TRAY LOADING CAPACITY.
WBT
WBT12X4
CABOLFIL
B-LINE
CHATSWORTH
SC-FDC-1 1-RU ANGLED FIBER DISTRIBUTION ENCLOSURE. 144 MAXIMUM FIBERS WITH SLIDING TRAY. PROVIDE COMPLETE WITH FIBER ADAPTER PANELS WITH LC CONNECTORS FOR ALL TERMINATED FIBERS. PROVIDE BLANK PANELS FOR ALL UNUSED
OPENINGS. PROVIDE CABLE CLAMP KITS AS REQUIRED, 5RCMP-KIT.
LEVITON
HDX1A-144
FIBER ADAPTER PANELS
SPLCH-12A (OM4)
SPLCH-12L (SM)
CABLE MANAGER:
E2XHD-CMB
BLANKS:
5F100-PLT
SC-GND-2 GROUNDING BUSBAR, WALL MOUNT. 4" H X 12" L X 1/4" D COPPER, ELECTRICALLY ISOLATED BY INSULATORS INTEGRAL TO MOUNTING BRACKETS. COPPER GROUND BAR IS 1/4" THICK AND STAND OFF 2.75" FROM WALL. THE 12" BUSBAR PROVIDES CONNECTION FOR EIGHTEEN (18) 2-HOLE COMPRESSION LUGS RESPECTIVELY WITH 5/8" OR 1" CENTERS. ANSI/TIA-607 AND
BICSI COMPLIANT. UL LISTED.
REFER TO GROUND BAR DETAIL ON 4/T400 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
CHATSWORTH
40158-012
PANDUIT
ERICO
HARGER
SC-GND-3 19" RACK-MOUNT HORIZONTAL GROUND BAR. 1/4"H X 19"L X 3/4"D. SOLID COPPER, ELECTRICALLY ISOLATED BY INSULATORS
INTEGRAL TO STAINLESS STEEL MOUNTING BRACKETS.
PROVIDE UNIT CONFIGURED WITH 15 SETS OF 5/16" HOLES SPACED 5/8" ON CENTER TO ACCOMMODATE "A" SPACED TWO-HOLE COMPRESSION LUGS AND 3 SETS OF 7/16" HOLES SPACED 1" ON CENTER TO ACCOMMODATE "C" SPACED
TWO-HOLE COMPRESSION LUGS. ANSI/EIA/TIA-607 AND BICSI COMPLIANT. UL LISTED.
REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
HUBBELL
HBBBHR19
BERK-TEK ORTRONICS
SYSTIMAX
SC-HWM-1 1RU HORIZONTAL CABLE MANAGER FOR 19' RACK MOUNTING, SINGLE SIDED, BLACK. FRONT COVER WITH HINGE CLIPS.
8.31" DEEP.
ORTRONICS
SHMC1RU
SC-HWM-2 2RU HORIZONTAL CABLE MANAGER FOR 19' RACK MOUNTING, SINGLE SIDED, BLACK. FRONT COVER WITH HINGE CLIPS.
8.86" DEEP.
ORTRONICS
SHMC2RU
SC-IO-C INFORMATION OUTLET, CEILING MOUNT. 2-PORT COVERPLATE AS INDICATED ON DRAWINGS AND INFORMATION
OUTLET SCHEDULE. REFER TO INFORMATION OUTLETSCHEDULE FOR PIN CONFIGURATION.
" # " INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE PLANS.
PROVIDE REMOVABLE BLANK INSERTS ON ALL UNSUSED PORTS. CABLING IS INSTALLED IN A SURFACE-MOUNT RACEWAY BOX WITH DUST COVER JACKS. COIL THE SLACK LOOP ON A J-HOOK LOCATED ON THE NEAREST STRUCTURAL ELEMENT IN
THE AREAS SHOWN ON THE DRAWINGS.
PANDUIT
BOX:
MINI-COM SERIES
JACK:
6AUJK-**6
SC-IO-W INFORMATION OUTLET, WALL MOUNT. 2, 4-PORT COVERPLATE AS INDICATED ON DRAWINGS AND INFORMATION OUTLET
SCHEDULE. REFER TO INFORMATION OUTLET SCHEDULE FOR PIN CONFIGURATION.
" # "INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE DRAWINGS.
INSTALL INFORMATION OUTLET IN A 4" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING. INSTALL A 1" EMT CONDUIT TO NEAREST ACCESSIBLE CEILING OR UNLESS OTHERWISE NOTED. PROVIDE REMOVABLE BLANK INSERTS FOR UNUSED PORTS AND FIRE RATED PUTTY PAD IN FIRE RATED WALLS. REFER TO THE TECHNOLOGY ROUGH-IN TO J-HOOK DETAIL AND
THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
LEVITON
WALLPLATE:
41081-4WP
JACK (CAT-6A):
6AUJK-**
BLANK INSERT:
41804-**
SC-LR-1 LADDER RACK, (12"W X 1.5"H X 9.71'L) TUBULAR STEEL CONSTRUCTION. RUST RESISTANT ENAMEL FINISH. REMOVE SHARP BURRS FROM LADDER RACK AND REPAINT ALL AREAS THAT HAVE BEEN FIELD MODIFIED, CUT, OR EXPOSED. UL LISTED.
PROVIDE WITH ALL NECESSARY MOUNTING BRACKETS, RACK ELEVATION KITS, AND (2) CABLE RADIUS DROPS PER RACK.
LADDER RACK ONLY FOR VERTICAL CABLE MANAGEMENT.
CHATSWORTH
LADDER RACK:
11275-712
RACK ELEVATION KIT:
10506-706
CABLE RADIUS DROP:
12100-712
SC-MPP-1 MODULAR PATCH PANEL, 48 MODULAR RJ-45 TERMINATIONS, MOUNTS DIRECTLY TO EIA/TIA STANDARD 19" RELAY RACK, PORT IDENTIFICATION NUMBERS, PROVIDED WITH COLOR CODING AND LABEL HOLDER KITS, U.L. LISTED. REQUIRES (1)
1.75" MOUNTING SPACES.
LEVITON
PANEL:
49255-Q48
JACK (CAT-6A):
6AUJK-**6
SC-NS-1 8-PORT LAYER 2/3/4 10/100/1000 GIGABIT SWITCH - POE. 48 RJ-45 CONNECTORS FOR 10BASE - T/100BASE-TX/1000 BASE-T WITH 4 GIGABIT COMBO PORTS SHARED BETWEEN MINI-GBIC PORTS: CONSOLE PORT: AUTO MEDIUM DEPENDENT
INTERFACE (MDI) AND MDI CROSSOVER (MDI-X). AUTO.
CISCO
5500 SERIES
SC-PDU-1 MODULAR POWER DISTRIBUTION SYSTEM, RACK MOUNT, 1RU. INPUT VOLTAGE 100V, OUTPUT VOLTAGE 120V. INPUT PLUG TYPE: NEMA L5-30P. OUTLET TYPE AND QUANTITY 10 NEMA 5-20R. MAX LINE CURRENT 24A, INPUT CURRENT LIMITS 30A, LOAD CAPACITY 2880VA.
APC
AP9560
SC-TTB TELECOMMUNICATIONS TERMINAL BOARD, 4’X8’X3/4” A-C GRADE FIRE-RATED PLYWOOD. EXPOSED SIDE SHALL BE SMOOTH. MOUNT VERTICALLY WITH TOP OF PLYWOOD AT 8’-6” AFF. IN THE EVENT THE MANUFACTURER’S RATING STAMP IS NOT VISIBLE ON THE SMOOTH SIDE, THE CONTRACTOR SHALL PROVIDE A LAMINATED LETTER FROM THE MANUFACTURER OR SUPPLIER CERTIFYING THAT THE PLYWOOD IS FIRE-RATED AND ATTACH THE LETTER WITH A PICTURE OF THE RATING STAMP, TO THE PLYWOOD. FIRE RATED PLYWOOD SHALL NOT BE PAINTED OR TREATED WITH ANY TYPE OF
SEALANT THAT WOULD LESSEN THE INTEGRITY OF THE FIRE RATING.
SC-UPS RACK MOUNT 3KVA SMART UPS. 2 RACK UNITS. NEMA L5-30P INPUT. (3) NEMA 5-15R, (3) NEMA 5-20R, AND (1) NEMA L5-30R
OUTPUTS, RACK MOUNTABLE.
APC
SMX3000RMLV2U
SUPPORT FOR POSSIBLE RELOCATION AFTER WIRELESS SURVEY.
1. LOCATION OF FUTURE OR OWNER PROVIDED WIRELESS ACCESS POINT. PROVIDE A 20' SLACK COIL AT THE NEAREST CABLE
SCHEDULE NOTES:
2. REFER TO SPECIFICATIONS SECTION 27 05 53 FOR ADDITIONAL INFORMATION ON LABELING REQUIREMENTS. BLANK BLANK FILLER MODULE
1. PROVIDE REMOVABLE BLANK INSERT(S) FOR ALL UNUSED PORTS. DATA CAT 6A RJ-45
NOTES: LEGEND
SINGLE GANG WALLPLATES
INFORMATION OUTLET SCHEDULE
CONFIGURATION F
A
C E
P L
A T
E P
O R
T S
FACEPLATE PORT IDENTIFICATION
NOTESP
O
S
IT
IO
N
J
A C
K T
Y P
E
P O
S
IT
IO
N
J
A C
K T
Y P
E
P O
S
IT
IO
N
J
A C
K T
Y P
E
P O
S
IT
IO
N
J
A C
K T
Y P
E
P O
S
IT
IO
N
J
A C
K T
Y P
E
P O
S
IT
IO
N
J
A C
K T
Y P
E
C1 2 DATA BLANK
C2 2 DATA DATA
C2-WAP 2 DATA DATA 1.
C3 4 DATA DATA DATA BLANK
C4 4 DATA DATA DATA DATA
1. ELECTRONIC DOOR HARDWARE SUCH AS ELECTRIC STRIKES, ELECTRIC LATCH RETRACTION, ETC. SHALL BE PROVIDED AND INSTALLED BY OTHERS.
2. REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE FOR CREDENTIAL READER TYPE INFORMATION.
ACCESS CONTROL DOOR TYPE SCHEDULE
S E
C U
R
IT
Y D
O O
R T
Y P
E
D E
T A
IL
R
E F
E R
E N
C E
DOOR #
CREDENTIAL
READER
REQUEST
TO EXIT DOOR HARDWARE / MONITORING INTEGRATION
OTHER
(REFER TO
NOTES)
NOTESC
R
E D
E N
T
IA
L R
E A
D E
R T
Y P
E
M U
L T
IP
L
E C
R E
D E
N T
IA
L
R E
A D
E R
S O
P E
R A
T E
S S
IN
G
L E
D O
O R
O P
E R
A T
E S
M U
L T
IP
L
E D
O O
R S
IN
T
E R
N A
L E
L E
C T
R
IF
IE
D
H A
R D
W A
R E
C O
N N
E C
T
IO
N
B Y
O T
H E
R S
M O
T
IO
N D
E T
E C
T O
R
L O
C A
L P
U S
H B
U T
T O
N D
O O
R H
A R
D W
A R
E O
V E
R R
ID
E
E L
E C
T R
O N
IC
L
O C
K
IN
G H
A R
D W
A R
E
B Y
O T
H E
R S
M A
G L
O C
K
L O
C A
L A
L A
R M
H O
R N
L A
T C
H S
T A
T U
S D
E T
E C
T
IO
N
B Y
O T
H E
R S
M O
N
IT
O R
L A
T C
H B
O L
T
B Y
O T
H E
R S
M O
N
IT
O R
D O
O R
P O
S
IT
IO
N
S W
IT
C
H S
P D
T
M O
N
IT
O R
D O
O R
P O
S
IT
IO
N
S W
IT
C
H D
P D
T
M O
N
IT
O R
D O
O R
P O
S
IT
IO
N
S W
IT
C
H
O V
E R
H E
A D
D O
O R
M O
N
IT
O R
D O
O R
P O
S
IT
IO
N
S W
IT
C
H
R O
O F
H A
T C
H
A U
T O
M A
T
IC
D O
O R
O P
E R
A T
O R
E L
E V
A T
O R
L O
C K
E D
B Y
E M
E R
G E
N C
Y D
U R
E S
S S
E Q
U E
N C
E
IN
F
A N
T P
R O
T E
C T
IO
N
R E
M O
T E
U N
L O
C K
V
IA
I N
T E
R C
O M
M A
S T
E R
R E
M O
T E
U N
L O
C K
V
IA
P U
S H
B U
T T
O N
IN
T
R U
S
IO
N D
E T
E C
T
IO
N
R E
M O
T E
U N
L O
C K
V
IA
F
IR
E C
O M
M A
N D
C E
N T
E R
V
ID
E O
S U
R V
E
IL
L A
N C
E
W A
N D
E R
P R
E V
E N
T
IO
N S
Y S
T E
M
D E
L A
Y E
D E
G R
E S
S
B Y
O T
H E
R S
L O
C A
L
V
A C
P O
W E
R S
U P
P L
Y
S C
H E
D U
L E
B A
S E
D L
O C
K
IN
G
V
IS
U A
L S
T R
O B
E /A
U D
IB
L
E A
L A
R M
101 DPS R1 ●
115 DPS R1 ●
121 DPO ●
C1945BBBB DPS R1 ● ●
C1945FFF DPS ●
C1945HHH DPS R1 ●
C1945HHH DPS ●
C1945JJJ DPS ●
C1945LLL DPS R1 ● ●
C1945NNNN DPO ●
C1945PPPP DPO ●
C1945RRRR DPO ●
C1945TTTT RIE ● ●
C1945TTTT DPO ●
C1945VVV DPS R1 ●
C1945WW DPO ●
C1945XXX DPS R1 ●
GATE 117 DPS R1 ●
THE EQUIPMENT LIST ABBREVIATIONS AND THE TECHNOLOGY EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING
SYSTEM.
CATALOG NUMBERS ARE NOT TO BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS. MANUFACTURER PROVIDED SHALL BE CONSISTENT WITH APPROVED MANUFACTURERS LISTED. "STANDARD COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE. ALL EQUIPMENT MUST MEET BUY AMERICAN REQUIREMENTS.
TECHNOLOGY EQUIPMENT SCHEDULE
EQUIPMENT LIST
ABBREVIATION EQUIPMENT LIST DESCRIPTION
MANUFACTURER AND
MODEL
VS-CM-1 EXTERIOR/INTERIOR 5MP (SINGLE SENSOR) CAMERA. FIXED DOME CAMERA FOR OUTDOOR, HDTV 1080P VIDEO QUALITY, VANDAL-RESISTANT WITH WDR.
PROVIDE A PROPER MOUNT BASED ON THE INSTALLED APPLICATIONS ON THE WALL OR CEILING. FOR WALL APPLICATIONS, PROVIDE A 4" SQUARE BACKBOX WITH CONDUIT TO ABOVE THE NEAREST ACCESSIBLE CEILING.
ALL CABLING SHALL BE EITHER ABOVE THE ACCESSIBLE CEILING OR INSTALLED IN CONDUIT. NO CABLING SHALL BE EXPOSED. FOR OPEN CEILINGS, INSTALL IN CONDUIT. REFER TO THE DRAWINGS FOR ADDITIONAL INFORMATION.
THE TECHNOLOGY EQUIPMENT SCHEDULE ONLY DESCRIBES CAMERA SERIES AND PERFORMANCE INFORMATION. REFER TO INDIVIDUAL CAMERA SCHEDULE ON SHEET T600 FOR ADDITIONAL INFORMATION ON INDIVIDUAL CAMERA
REQUIREMENTS, ROUGH-IN, AND MOUNTING.
AXIS COMMUNICATIONS
P3367-VE
VS-KVM-1 17" LCD RACK MOUNT SLIDE OUT MONITOR WITH KEYBOARD AND TWO BUTTON TOUCH PAD MOUSE AND BUILT-IN 8-PORT DVI/USB KVM. COORDINATE WITH OWNER ON MONITOR HEIGHT IN RACK. REQUIRES (1) 1.75 MOUNTING SPACE. PROVIDE
WITH ALL NECESSARY CABLES TO CONNECT TO ALL CCTV EQUIPMENT.
NTI
RACKMUX-D17-N-8DVIHD
VS-VMS-1 VIDEO MANAGEMENT SERVER. REQUIRES (2) RACK UNITS.
REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
GENETEC
INDIVIDUAL CAMERA REQUIREMENTS SCHEDULE
CAMERA #
CAMERA
TYPE
CAMERA
ENVIRONMENT
TELECOM
ROOM # LOCATION FIELD OF VIEW DESCRIPTION
MOUNTING
TYPE
DETAIL
REFERENCE F
R A
M E
R A
T E
P E
R C
E N
T M
O T
IO
N
ADDITIONAL
INFORMATION NOTES
01-01 CM-1 INTERIOR TE/1 100/RECEPTION STANDARD VIEW CEILING 3/T401 15 50
01-02 CM-1 INTERIOR TE/1 110/EXISTING
ADMIN STAFF
STANDARD VIEW CEILING 3/T401 15 50
01-03 CM-1 INTERIOR TE/1 113/ALCOVE STANDARD VIEW CEILING 3/T401 15 50
01-04 CM-1 INTERIOR TE/1 TE/1 STANDARD VIEW CEILING 3/T401 15 50
01-05 CM-1 INTERIOR TE/2 EXISTING
LUNCH
STANDARD VIEW CEILING 3/T401 15 50
01-06 CM-1 INTERIOR TE/2 MAINTENANCE
BAYS
STANDARD VIEW CEILING N/A 15 50
01-07 CM-1 INTERIOR TE/2 TE/2 STANDARD VIEW CEILING N/A 15 50
Revisions: Date: 149 of 155
GENERAL FIRE ALARM EQUIPMENT SCHEDULE
THE SYMBOLS AND THE EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING
SYSTEM.
CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS. MANUFACTURER PROVDED SHALL BE CONSISTENT WITH APPROVED MANUFACTURERS LISTED.
"STANDARD COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE. ALL EQUIPMENT MUST MEET BUY AMERICAN REQUIREMENTS. REFER
TO SPECIFICATIONS FOR MORE INFORMATION.
ITEM
NO
SYMBOL DESCRIPTION
FIRE ALARM ANNUNCIATOR PANEL, POWERED FROM FIRE ALARM CONTROL PANEL, SURFACE
MOUNT.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
FAA-#
SMOKE DETECTOR, ADDRESSABLE, ANALOG PHOTOELECTRIC SENSOR, 24 VDC, 2-PIECE DESIGN, LOW-PROFILE MOUNTING BASE WITH MULTI-FUNCTION LED INDICATOR, COMPLETE WITH
MOUNTING HARDWARE AND BACKBOX.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
HEAT DETECTOR, ADDRESSABLE, ANALOG SENSOR, COMBINATION RATE OF RISE AND 135
DEGREE FAHRENHEIT FIXED TEMPERATURE, 2-WIRE OPERATION, 24 VDC, 2-PIECE DESIGN, LOW-
PROFILE MOUNTING BASE WITH MULTI-FUNCTION LED INDICATOR, COMPLETE WITH MOUNTING
HARDWARE AND BACKBOX. PROVIDE A REMOTE LED INDICATOR DEVICE IF DETECTOR IS NOT
VISIBLE FROM A FLOOR-STANDING POSITION.
FIRE ALARM MANUAL PULL STATION, ADDRESSABLE, SINGLE ACTION WITH PLASTIC BREAKROD, RESET KEY LOCK, SEMI-FLUSH MOUNT, RED HIGH-ABUSE PLASTIC OR CAST METAL
CONSTRUCTION WITH WHITE LETTERING. USE SURFACE MOUNT ONLY ON PRECAST CONCRETE
OR STRUCTURE.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
F
FIRE ALARM CEILING AUDIO/VISUAL NOTIFICATION APPLIANCE, ELECTRONIC HORN WITH
SELECTABLE CONTINUOUS OR TEMPORAL TONE, SELECTABLE SOUND OUTPUT, AND HIGH
INTENSITY STROBE, WHITE HOUSING WITH RED LETTERING OR PICTOGRAM, SEMI-FLUSH CEILING
MOUNT, 24 VDC.
CANDELA RATINGS: 15cd, 75cd. CANDELA
RATING SHALL BE VISIBLE FROM THE OUTSIDE OF THE DEVICE.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
FIRE ALARM WALL AUDIO/VISUAL NOTIFICATION APPLIANCE, ELECTRONIC HORN WITH SELECTABLE CONTINUOUS OR TEMPORAL TONE, SELECTABLE SOUND OUTPUT, AND HIGH-INTENSITY STROBE, RED
HOUSING WITH WHITE LETTERING OR PICTOGRAM, SEMI-FLUSH WALL MOUNT, 24 VDC.
CANDELA RATINGS: 15cd, 75cd. CANDELA
RATING SHALL BE VISIBLE FROM THE OUTSIDE OF THE DEVICE.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
F
F
S
H
FIRE ALARM CONTROL PANEL, ADDRESSABLE SYSTEM, FEATURING INTERFACE WITH ANALOG
SENSING INITIATING DEVICES, EXPANDABLE MODULAR DESIGN, MICROPROCESSOR BASED
ELECTRONICS, 120 VAC OPERATION, SURFACE MOUNT.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
FACP-#
GAS DETECTOR, ADDRESSABLE, ANALOG CARBON MONOXIDE TYPE SENSOR, CARBON MONOXIDE
ELECTROLYTIC SENSING MODULE SHALL PROVIDE TOXIC GAS SENSING TO UL2034 AND UL2075
STANDARDS, 24 VDC, LOW-PROFILE MOUNTING BASE WITH MULTI-FUNCTION LED INDICATOR,
COMPLETE WITH MOUNTING HARDWARE AND BACKBOX. CO SENSOR CARTRIDGE ELEMENT SHALL
BE FIELD REPLACEABLE.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
APPROVED MANUFACTURERS
FIRE ALARM CEILING VISUAL NOTIFICATION APPLIANCE, HIGH-INTENSITY STROBE, WHITE HOUSING
WITH RED LETTERING OR PICTOGRAM, SEMI-FLUSH CEILING MOUNT; 24 VDC.
CANDELA RATINGS: 15cd, 75cd. CANDELA
RATING SHALL BE VISIBLE FROM THE OUTSIDE OF THE DEVICE.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
FIRE ALARM ADDRESSABLE RELAY CONSISTING OF AN ADDRESSABLE CONTROL MODULE AND
SLAVE RELAY WITH CONTACTS SUITABLE FOR CONTROLLING THE DESIGNATED AUXILIARY LOAD, PROVIDE AN ADDITIONAL CHILD RELAY(S) AS REQUIRED, 24 VDC, 4-WIRE OPERATION, MOUNT IN
ENCLOUSER IN AN ACCESSIBLE SERVICE LOCATION.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
CM
FIRE ALARM WALL VISUAL NOTIFICATION APPLIANCE, HIGH-INTENSITY STROBE, RED HOUSING
WITH WHITE LETTERING OR PICTOGRAM, SEMI-FLUSH WALL MOUNT; 24 VDC.
CANDELA RATINGS: 15cd, 75cd. CANDELA
RATING SHALL BE VISIBLE FROM THE OUTSIDE OF THE DEVICE.
NOTIFIER BY HONEYWELL
SIEMENS FIRE SAFETY
EDWARDS - EST
HOCHIKI AMERICA
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
SIMSIM
INDICATES SIMILAR DETAIL REFERENCED
IN MULTIPLE LOCATIONS
LEVEL NAME
10'-0" HEIGHT ABOVE
PROJECT 0'-0"
1 KEYNOTE: INDICATES NOTE USED TO
DESCRIBE ADDITIONAL INFORMATION
ABOUT WORK REQUIRED, SPECIFIC
TO THE SHEET AND/OR DETAIL
N
O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
LINE TYPE AND TAG KEY:
NEW WORK BY THIS CONTRACTOR (WIDE LINE)
EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)
HALF TONING DOES NOT MODIFY SCOPE.
'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING
TAG-1 UNDERLINED TAG…